SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:2072 666X "

Sökning: L773:2072 666X

  • Resultat 1-50 av 79
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bleiker, Simon J., et al. (författare)
  • Cost-Efficient Wafer-Level Capping for MEMS and Imaging Sensors by Adhesive Wafer Bonding
  • 2016
  • Ingår i: Micromachines. - Basel, Switzerland : Multidisciplinary Digital Publishing Institute (MDPI). - 2072-666X. ; 7:10, s. 192-
  • Tidskriftsartikel (refereegranskat)abstract
    • Device encapsulation and packaging often constitutes a substantial part of the fabrication cost of micro electro-mechanical systems (MEMS) transducers and imaging sensor devices. In this paper, we propose a simple and cost-effective wafer-level capping method that utilizes a limited number of highly standardized process steps as well as low-cost materials. The proposed capping process is based on low-temperature adhesive wafer bonding, which ensures full complementary metal-oxide-semiconductor (CMOS) compatibility. All necessary fabrication steps for the wafer bonding, such as cavity formation and deposition of the adhesive, are performed on the capping substrate. The polymer adhesive is deposited by spray-coating on the capping wafer containing the cavities. Thus, no lithographic patterning of the polymer adhesive is needed, and material waste is minimized. Furthermore, this process does not require any additional fabrication steps on the device wafer, which lowers the process complexity and fabrication costs. We demonstrate the proposed capping method by packaging two different MEMS devices. The two MEMS devices include a vibration sensor and an acceleration switch, which employ two different electrical interconnection schemes. The experimental results show wafer-level capping with excellent bond quality due to the re-flow behavior of the polymer adhesive. No impediment to the functionality of the MEMS devices was observed, which indicates that the encapsulation does not introduce significant tensile nor compressive stresses. Thus, we present a highly versatile, robust, and cost-efficient capping method for components such as MEMS and imaging sensors.
  •  
2.
  • Abbaszadehbanaeiyan, Amin, 1983, et al. (författare)
  • Hydrodynamic Cell Trapping for High Throughput Single-Cell Applications
  • 2013
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 4:4, s. 414-430
  • Tidskriftsartikel (refereegranskat)abstract
    • The possibility to conduct complete cell assays under a precisely controlled environment while consuming minor amounts of chemicals and precious drugs have made microfluidics an interesting candidate for quantitative single-cell studies. Here, we present an application-specific microfluidic device, cellcomb, capable of conducting high-throughput single-cell experiments. The system employs pure hydrodynamic forces for easy cell trapping and is readily fabricated in polydimethylsiloxane (PDMS) using soft lithography techniques. The cell-trapping array consists of V-shaped pockets designed to accommodate up to six Saccharomyces cerevisiae (yeast cells) with the average diameter of 4 μm. We used this platform to monitor the impact of flow rate modulation on the arsenite (As(III)) uptake in yeast. Redistribution of a green fluorescent protein (GFP)-tagged version of the heat shock protein Hsp104 was followed over time as read out. Results showed a clear reverse correlation between the arsenite uptake and three different adjusted low = 25 nL min−1, moderate = 50 nL min−1, and high = 100 nL min−1 flow rates. We consider the presented device as the first building block of a future integrated application-specific cell-trapping array that can be used to conduct complete single cell experiments on different cell types.
  •  
3.
  • Afrasiabi, Roodabeh, et al. (författare)
  • Integration of a droplet-based microfluidic system and silicon nanoribbon FET sensor
  • 2016
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 7:8
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a novel microfluidic system that integrates droplet microfluidics with a silicon nanoribbon field-effect transistor (SiNR FET), and utilize this integrated system to sense differences in pH. The device allows for selective droplet transfer to a continuous water phase, actuated by dielectrophoresis, and subsequent detection of the pH level in the retrieved droplets by SiNR FETs on an electrical sensor chip. The integrated microfluidic system demonstrates a label-free detection method for droplet microfluidics, presenting an alternative to optical fluorescence detection. In this work, we were able to differentiate between droplet trains of one pH-unit difference. The pH-based detection method in our integrated system has the potential to be utilized in the detection of biochemical reactions that induce a pH-shift in the droplets.
  •  
4.
  • Ainla, Alar, 1982, et al. (författare)
  • Hydrodynamic Flow Confinement Technology in Microfluidic Perfusion Devices
  • 2012
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 3:2, s. 442-461
  • Forskningsöversikt (refereegranskat)abstract
    • Hydrodynamically confined flow device technology is a young research area with high practical application potential in surface processing, assay development, and in various areas of single cell research. Several variants have been developed, and most recently, theoretical and conceptual studies, as well as fully developed automated systems, were presented. In this article we review concepts, fabrication strategies, and application areas of hydrodynamically confined flow (HCF) devices.
  •  
5.
  • Akan, Rabia, et al. (författare)
  • Metal-Assisted Chemical Etching and Electroless Deposition for Fabrication of Hard X-ray Pd/Si Zone Plates
  • 2020
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 11:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Zone plates are diffractive optics commonly used in X-ray microscopes. Here, we present a wet-chemical approach for fabricating high aspect ratio Pd/Si zone plate optics aimed at the hard X-ray regime. A Si zone plate mold is fabricated via metal-assisted chemical etching (MACE) and further metalized with Pd via electroless deposition (ELD). MACE results in vertical Si zones with high aspect ratios. The observed MACE rate with our zone plate design is 700 nm/min. The ELD metallization yields a Pd density of 10.7 g/cm3, a value slightly lower than the theoretical density of 12 g/cm3. Fabricated zone plates have a grid design, 1:1 line-to-space-ratio, 30 nm outermost zone width, and an aspect ratio of 30:1. At 9 keV X-ray energy, the zone plate device shows a first order diffraction efficiency of 1.9%, measured at the MAX IV NanoMAX beamline. With this work, the possibility is opened to fabricate X-ray zone plates with low-cost etching and metallization methods.
  •  
6.
  •  
7.
  • Bernardin, Evans K., et al. (författare)
  • Demonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface
  • 2018
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 9:8
  • Tidskriftsartikel (refereegranskat)abstract
    • Intracortical neural interfaces (INI) have made impressive progress in recent years but still display questionable long-term reliability. Here, we report on the development and characterization of highly resilient monolithic silicon carbide (SiC) neural devices. SiC is a physically robust, biocompatible, and chemically inert semiconductor. The device support was micromachined from p-type SiC with conductors created from n-type SiC, simultaneously providing electrical isolation through the resulting p-n junction. Electrodes possessed geometric surface area (GSA) varying from 496 to 500 K m(2). Electrical characterization showed high-performance p-n diode behavior, with typical turn-on voltages of 2.3 V and reverse bias leakage below 1 nArms. Current leakage between adjacent electrodes was 7.5 nArms over a voltage range of -50 V to 50 V. The devices interacted electrochemically with a purely capacitive relationship at frequencies less than 10 kHz. Electrode impedance ranged from 675 +/- 130 k (GSA = 496 mu m(2)) to 46.5 +/- 4.80 k (GSA = 500 K mu m(2)). Since the all-SiC devices rely on the integration of only robust and highly compatible SiC material, they offer a promising solution to probe delamination and biological rejection associated with the use of multiple materials used in many current INI devices.
  •  
8.
  • Birkholz, Mario, et al. (författare)
  • Continuously operating biosensor and its integration into a hermetically sealed medical implant
  • 2016
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 7:10
  • Tidskriftsartikel (refereegranskat)abstract
    • An integration concept for an implantable biosensor for the continuous monitoring of blood sugar levels is presented. The system architecture is based on technical modules used in cardiovascular implants in order to minimize legal certification efforts for its perspective usage in medical applications. The sensor chip operates via the principle of affinity viscometry, which is realized by a fully embedded biomedical microelectromechanical systems (BioMEMS) prepared in 0.25-μm complementary metal-oxide-semiconductor (CMOS)/BiCMOS technology. Communication with a base station is established in the 402-405 MHz band used for medical implant communication services (MICS). The implant shall operate within the interstitial tissue, and the hermetical sealing of the electronic system against interaction with the body fluid is established using titanium housing. Only the sensor chip and the antenna are encapsulated in an epoxy header closely connected to the metallic housing. The study demonstrates that biosensor implants for the sensing of low-molecular-weight metabolites in the interstitial may successfully rely on components already established in cardiovascular implantology.
  •  
9.
  • Bodé, William Naundrup, et al. (författare)
  • Microparticle acoustophoresis in aluminum-based acoustofluidic devices with PDMS covers
  • 2020
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 11:3
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a numerical model for the recently introduced simple and inexpensive micromachined aluminum devices with a polydimethylsiloxane (PDMS) cover for microparticle acoustophoresis. We validate the model experimentally for a basic design, where a microchannel is milled into the surface of an aluminum substrate, sealed with a PDMS cover, and driven at MHz frequencies by a piezoelectric lead-zirconate-titanate (PZT) transducer. Both experimentally and numerically we find that the soft PDMS cover suppresses the Rayleigh streaming rolls in the bulk. However, due to the low transverse speed of sound in PDMS, such devices are prone to exhibit acoustic streaming vortices in the corners with a relatively large velocity. We predict numerically that in devices, where the microchannel is milled all the way through the aluminum substrate and sealed with a PDMS cover on both the top and bottom, the Rayleigh streaming is suppressed in the bulk thus enabling focusing of sub-micrometer-sized particles.
  •  
10.
  • Chang, Bo, et al. (författare)
  • Capillary Self-Alignment of Microchips on Soft Substrates
  • 2016
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 7:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Soft micro devices and stretchable electronics have attracted great interest for their potential applications in sensory skins and wearable bio-integrated devices. One of the most important steps in building printed circuits is the alignment of assembled micro objects. Previously, the capillary self-alignment of microchips driven by surface tension effects has been shown to be able to achieve high-throughput and high-precision in the integration of micro parts on rigid hydrophilic/superhydrophobic patterned surfaces. In this paper, the self-alignment of microchips on a patterned soft and stretchable substrate, which consists of hydrophilic pads surrounded by a superhydrophobic polydimethylsiloxane (PDMS) background, is demonstrated for the first time. A simple process has been developed for making superhydrophobic soft surface by replicating nanostructures of black silicon onto a PDMS surface. Different kinds of PDMS have been investigated, and the parameters for fabricating superhydrophobic PDMS have been optimized. A self-alignment strategy has been proposed that can result in reliable self-alignment on a soft PDMS substrate. Our results show that capillary self-alignment has great potential for building soft printed circuits.
  •  
11.
  • Comina, German, et al. (författare)
  • 3D Printed Unibody Lab-on-a-Chip: Features Survey and Check-Valves Integration dagger
  • 2015
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 6:4, s. 437-451
  • Tidskriftsartikel (refereegranskat)abstract
    • The unibody lab-on-a-chip (ULOC) concept entails a fast and affordable micro-prototyping system built around a single monolithic 3D printed element (unibody). A consumer-grade stereo lithography (SL) 3D printer can configure ULOCs with different forms of sample delivery, transport, handling and readout, while minimizing material costs and fabrication time. ULOC centralizes all complex fabrication procedures and replaces the need for clean room resources, delivering prototypes for less than 1 US$, which can be printed in 10 min and ready for testing in less than 30 min. Recent examples of ULOC integration of transport, chemical sensing for optical readout and flow mixing capabilities are discussed, as well as the integration of the first check-valves for ULOC devices. ULOC valves are strictly unidirectional up to 100 psi, show an exponential forward flow behavior up to 70 psi and can be entirely fabricated with the ULOC approach.
  •  
12.
  • Dagar, Janardan, et al. (författare)
  • Stability assessment of p-i-n perovskite photovoltaic mini-modules utilizing different top metal electrodes
  • 2021
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 12:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Long-term stability is one of the major challenges for p-i-n type perovskite solar modules (PSMs). Here, we demonstrate the fabrication of fully laser-patterned series interconnected p-i-n perovskite mini-modules, in which either single Cu or Ag layers are compared with Cu/Au metalbilayer top electrodes. According to the scanning electron microscopy measurements, we found that Cu or Ag top electrodes often exhibit flaking of the metal upon P3 (top contact removal) laser patterning. For Cu/Au bilayer top electrodes, metal flaking may cause intermittent short-circuits between interconnected sub-cells during operation, resulting in fluctuations in the maximum power point (MPP). Here, we demonstrate Cu/Au metal-bilayer-based PSMs with an efficiency of 18.9% on an active area of 2.2 cm2 under continuous 1-sun illumination. This work highlights the importance of optimizing the top-contact composition to tackle the operational stability of mini-modules, and could help to improve the feasibility of large-area module deployment for the commercialization of perovskite photovoltaics.
  •  
13.
  • Elhami Nik, Farzad, et al. (författare)
  • Low-Cost PVD Shadow Masks with Submillimeter Resolution from Laser-Cut Paper
  • 2020
  • Ingår i: Micromachines. - Basel : MDPI. - 2072-666X. ; 11:7
  • Tidskriftsartikel (refereegranskat)abstract
    • We characterize an affordable method of producing stencils for submillimeter physical vapor deposition (PVD) by using paper and a benchtop laser cutter. Patterning electrodes or similar features on top of organic or biological substrates is generally not possible using standard photolithography. Shadow masks, traditionally made of silicon-based membranes, circumvent the need for aggressive solvents but suffer from high costs. Here, we evaluate shadow masks fabricated by CO2 laser processing from quantitative filter papers. Such papers are stiff and dimensionally stable, resilient in handling, and cut without melting or redeposition. Using two exemplary interdigitated electrode designs, we quantify the line resolution achievable with both high-quality and standard lenses, as well as the positional accuracy across multiple length scales. Additionally, we assess the gap between such laser-cut paper masks and a substrate, and quantify feature reproduction onto polycarbonate membranes. We find that ~100 µm line widths are achievable independent of lens type and that average positional accuracy is better than ±100 µm at 4”-wafer scale. Although this falls well short of the micron-size features achievable with typical shadow masks, resolution in the tenths to tens of millimeters is entirely sufficient for applications from contact pads to electrochemical cells, allowing new functionalities on fragile materials.
  •  
14.
  • Enrichi, Francesco, et al. (författare)
  • Ag-Sensitized Yb3+ Emission in Glass-Ceramics
  • 2018
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 9:8
  • Tidskriftsartikel (refereegranskat)abstract
    • Rare earth doped materials play a very important role in the development of many photonic devices, such as optical amplifiers and lasers, frequency converters, solar concentrators, up to quantum information storage devices. Among the rare earth ions, ytterbium is certainly one of the most frequently investigated and employed. The absorption and emission properties of Yb3+ ions are related to transitions between the two energy levels 2F7/2 (ground state) and 2F5/2 (excited state), involving photon energies around 1.26 eV (980 nm). Therefore, Yb3+ cannot directly absorb UV or visible light, and it is often used in combination with other rare earth ions like Pr3+, Tm3+, and Tb3+, which act as energy transfer centres. Nevertheless, even in those co-doped materials, the absorption bandwidth can be limited, and the cross section is small. In this paper, we report a broadband and efficient energy transfer process between Ag dimers/multimers and Yb3+ ions, which results in a strong PL emission around 980 nm under UV light excitation. Silica-zirconia (70% SiO2-30% ZrO2) glass-ceramic films doped by 4 mol.% Yb3+ ions and an additional 5 mol.% of Na2O were prepared by sol-gel synthesis followed by a thermal annealing at 1000 °C. Ag introduction was then obtained by ion-exchange in a molten salt bath and the samples were subsequently annealed in air at 430 °C to induce the migration and aggregation of the metal. The structural, compositional, and optical properties were investigated, providing evidence for efficient broadband sensitization of the rare earth ions by energy transfer from Ag dimers/multimers, which could have important applications in different fields, such as PV solar cells and light-emitting near-infrared (NIR) devices.
  •  
15.
  • Farjana, Sadia, 1983, et al. (författare)
  • Dry film photoresist-based microfabrication : A new method to fabricate millimeter-wave waveguide components
  • 2021
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 12:3
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a novel fabrication method based on dry film photoresists to realize waveguides and waveguide-based passive components operating at the millimeter-wave frequency (30–300 GHz). We demonstrate that the proposed fabrication method has a high potential as an alternative to other microfabrication technologies, such as silicon-based and SU8-based micromachining for realizing millimeter-wave waveguide components. Along with the nearly identical transfer of geometrical structures, the dry film photoresist offers other advantages such as fewer processing steps, lower production cost, and shorter prototyping time over the conventional micromachining technologies. To demonstrate the feasibility of the fabrication process, we use SUEX dry film to fabricate a ridge gap waveguide resonator. The resonator is designed to exhibit two resonances at 234.6 and 284 GHz. The measured attenuation at 234 GHz is 0.032 dB/mm and at 283 GHz is 0.033 dB/mm for the fabricated prototype. A comparative study among different existing technologies indicates that the reported method can give a better unloaded Q-value than other conventional processes. The measured unloaded Q-values are in good agreement with the simulated unloaded Q-values. The signal attenuation indicates that SUEX dry film photoresists can be used to fabricate passive devices operating at millimeter-wave frequencies. Moreover, this new fabrication method can offer fast and low-cost prototyping. © 2021 by the authors.
  •  
16.
  • Fornell, Anna, et al. (författare)
  • Fabrication of Silicon Microfluidic Chips for Acoustic Particle Focusing Using Direct Laser Writing
  • 2020
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 11:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed a fast and simple method for fabricating microfluidic channels in silicon using direct laser writing. The laser microfabrication process was optimised to generate microfluidic channels with vertical walls suitable for acoustic particle focusing by bulk acoustic waves. The width of the acoustic resonance channel was designed to be 380 µm, branching into a trifurcation with 127 µm wide side outlet channels. The optimised settings used to make the microfluidic channels were 50% laser radiation power, 10 kHz pulse frequency and 35 passes. With these settings, six chips could be ablated in 5 h. The microfluidic channels were sealed with a glass wafer using adhesive bonding, diced into individual chips, and a piezoelectric transducer was glued to each chip. With acoustic actuation at 2.03 MHz a half wavelength resonance mode was generated in the microfluidic channel, and polystyrene microparticles (10 µm diameter) were focused along the centre-line of the channel. The presented fabrication process is especially interesting for research purposes as it opens up for rapid prototyping of silicon-glass microfluidic chips for acoustofluidic applications.
  •  
17.
  • Gatty, Hithesh K., et al. (författare)
  • A Miniaturized Amperometric Hydrogen Sulfide Sensor Applicable for Bad Breath Monitoring
  • 2018
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 9:12
  • Tidskriftsartikel (refereegranskat)abstract
    • Bad breath or halitosis affects a majority of the population from time to time, causing personal discomfort and social embarrassment. Here, we report on a miniaturized, microelectromechanical systems (MEMS)-based, amperometric hydrogen sulfide (H2S) sensor that potentially allows bad breath quantification through a small handheld device. The sensor is designed to detect H2S gas in the order of parts-per-billion (ppb) and has a measured sensitivity of 0.65 nA/ppb with a response time of 21 s. The sensor was found to be selective to NO and NH3 gases, which are normally present in the oral breath of adults. The ppb-level detection capability of the integrated sensor, combined with its relatively fast response and high sensitivity to H2S, makes the sensor potentially applicable for oral breath monitoring.
  •  
18.
  • Gevari, Moein Talebian, et al. (författare)
  • Engineered Lateral Roughness Element Implementation and Working Fluid Alteration to Intensify Hydrodynamic Cavitating Flows on a Chip for Energy Harvesting
  • 2020
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Hydrodynamic cavitation is considered an effective tool to be used in different applications, such as surface cleaning, ones in the food industry, energy harvesting, water treatment, biomedical applications, and heat transfer enhancement. Thus, both characterization and intensification of cavitation phenomenon are of great importance. This study involves design and optimization of cavitation on chip devices by utilizing wall roughness elements and working fluid alteration. Seven different microfluidic devices were fabricated and tested. In order to harvest more energy from cavitating flows, different roughness elements were used to decrease the inlet pressure (input to the system), at which cavitation inception occurs. The implemented wall roughness elements were engineered structures in the shape of equilateral triangles embedded in the design of the microfluidic devices. The cavitation phenomena were also studied using ethanol as the working fluid, so that the fluid behavior differences in the tested cavitation on chip devices were explained and compared. The employment of the wall roughness elements was an effective approach to optimize the performances of the devices. The experimental results exhibited entirely different flow patterns for ethanol compared to water, which suggests the dominant effect of the surface tension on hydrodynamic cavitation in microfluidic channels.
  •  
19.
  • Guo, Xiaorui, et al. (författare)
  • Silicon Carbide Converters and MEMS Devices for High-temperature Power Electronics: A Critical Review
  • 2019
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 10:6
  • Forskningsöversikt (refereegranskat)abstract
    • The significant advance of power electronics in today's market is calling for high-performance power conversion systems and MEMS devices that can operate reliably in harsh environments, such as high working temperature. Silicon-carbide (SiC) power electronic devices are featured by the high junction temperature, low power losses, and excellent thermal stability, and thus are attractive to converters and MEMS devices applied in a high-temperature environment. This paper conducts an overview of high-temperature power electronics, with a focus on high-temperature converters and MEMS devices. The critical components, namely SiC power devices and modules, gate drives, and passive components, are introduced and comparatively analyzed regarding composition material, physical structure, and packaging technology. Then, the research and development directions of SiC-based high-temperature converters in the fields of motor drives, rectifier units, DC-DC converters are discussed, as well as MEMS devices. Finally, the existing technical challenges facing high-temperature power electronics are identified, including gate drives, current measurement, parameters matching between each component, and packaging technology.
  •  
20.
  • Guo, Yuchen, et al. (författare)
  • Design Applicable 3D Microfluidic Functional Units Using 2D Topology Optimization with Length Scale Constraints
  • 2020
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 11:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Due to the limits of computational time and computer memory, topology optimization problems involving fluidic flow frequently use simplified 2D models. Extruded versions of the 2D optimized results typically comprise the 3D designs to be fabricated. In practice, the depth of the fabricated flow channels is finite; the limited flow depth together with the no-slip condition potentially make the fluidic performance of the 3D model very different from that of the simplified 2D model. This discrepancy significantly limits the usefulness of performing topology optimization involving fluidic flow in 2D—at least if special care is not taken. Inspired by the electric circuit analogy method, we limit the widths of the microchannels in the 2D optimization process. To reduce the difference of fluidic performance between the 2D model and its 3D counterpart, we propose an applicable 2D optimization model, and ensure the manufacturability of the obtained layout, combinations of several morphology-mimicking filters impose maximum or minimum length scales on the solid phase or the fluidic phase. Two typical Lab-on-chip functional units, Tesla valve and fluidic channel splitter, are used to illustrate the validity of the proposed application of length scale control.
  •  
21.
  • Hamngren Blomqvist, Charlotte, 1984, et al. (författare)
  • A Single-Cell Study of a Highly Effective Hog1 Inhibitor for in Situ Yeast Cell Manipulation
  • 2014
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 5:1, s. 81-96
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a single cell study of a highly effective Hog1 inhibitor. For this application, we used sequential treatment of a Saccharomyces cerevisiae cell array, with the Hog1 inhibitor and osmotic stress. For this purpose, a four-inlet microfluidic chamber with controlled introduction of two different cell strains within the same experimental setting and a subsequent rapid switching between treatments was designed. Multiple cell strains within the same experiment is a unique feature which is necessary for determining the expected absent cellular response. The nuclear translocation of the cytosolic MAPK, Hog1, was monitored by fluorescence imaging of Hog1-GFP on a single-cell level. An optical tweezers setup was used for controlled cell capture and array formation. Nuclear Hog1-GFP localization was impaired for treated cells, providing evidence of a congenial microfluidic setup, where the control cells within the experiments validated its appropriateness. The chamber enables multiple treatments with incubation times in the order of seconds and the possibility to remove either of the treatments during measurement. This flexibility and the possibility to use internal control cells ensures it a valuable scientific tool for unraveling the HOG pathway, similar signal transduction pathways and other biological mechanisms where temporal resolution and real time imaging is a prerequisite.
  •  
22.
  • Ho, Bao D., et al. (författare)
  • Cell sorting using electrokinetic deterministic lateral displacement
  • 2020
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We show that by combining deterministic lateral displacement (DLD) with electrokinetics, it is possible to sort cells based on differences in their membrane and/or internal structures. Using heat to deactivate cells, which change their viability and structure, we then demonstrate sorting of a mixture of viable and non-viable cells for two different cell types. For Escherichia coli, the size change due to deactivation is insufficient to allow size-based DLD separation. Our method instead leverages the considerable change in zeta potential to achieve separation at low frequency. Conversely, for Saccharomyces cerevisiae (Baker’s yeast) the heat treatment does not result in any significant change of zeta potential. Instead, we perform the sorting at higher frequency and utilize what we believe is a change in dielectrophoretic mobility for the separation. We expect our work to form a basis for the development of simple, low-cost, continuous label-free methods that can separate cells and bioparticles based on their intrinsic properties.
  •  
23.
  • Ho, Bao D., et al. (författare)
  • Charge-based separation of micro-and nanoparticles
  • 2020
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 11:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Deterministic Lateral Displacement (DLD) is a label-free particle sorting method that separates by size continuously and with high resolution. By combining DLD with electric fields (eDLD), we show separation of a variety of nano and micro-sized particles primarily by their zeta potential. Zeta potential is an indicator of electrokinetic charge—the charge corresponding to the electric field at the shear plane—an important property of micro-and nanoparticles in colloidal or separation science. We also demonstrate proof of principle of separation of nanoscale liposomes of different lipid compositions, with strong relevance for biomedicine. We perform careful characterization of relevant experimental conditions necessary to obtain adequate sorting of different particle types. By choosing a combination of frequency and amplitude, sorting can be made sensitive to the particle subgroup of interest. The enhanced displacement effect due to electrokinetics is found to be significant at low frequency and for particles with high zeta potential. The effect appears to scale with the square of the voltage, suggesting that it is associated with either non-linear electrokinetics or dielectrophoresis (DEP). However, since we observe large changes in separation behavior over the frequency range at which DEP forces are expected to remain constant, DEP can be ruled out.
  •  
24.
  • Inglis, David W., et al. (författare)
  • Microfluidic obstacle arrays induce large reversible shape change in red blood cells
  • 2021
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 12:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Red blood cell (RBC) shape change under static and dynamic shear stress has been a source of interest for at least 50 years. High-speed time-lapse microscopy was used to observe the rate of deformation and relaxation when RBCs are subjected to periodic shear stress and deformation forces as they pass through an obstacle. We show that red blood cells are reversibly de-formed and take on characteristic shapes not previously seen in physiological buffers when the maximum shear stress was between 2.2 and 25 Pa (strain rate 2200 to 25,000 s−1). We quantify the rates of RBC deformation and recovery using Kaplan–Meier survival analysis. The time to deformation decreased from 320 to 23 milliseconds with increasing flow rates, but the distance traveled before deformation changed little. Shape recovery, a measure of degree of deformation, takes tens of milliseconds at the lowest flow rates and reached saturation at 2.4 s at a shear stress of 11.2 Pa indicating a maximum degree of deformation was reached. The rates and types of deformation have relevance in red blood cell disorders and in blood cell behavior in microfluidic devices.
  •  
25.
  • Jayakumar, Ganesh, et al. (författare)
  • Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
  • 2018
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 9:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Silicon ribbons (SiRi) have been well-established as highly sensitive transducers for biosensing applications thanks to their high surface to volume ratio. However, selective and multiplexed detection of biomarkers remains a challenge. Further, very few attempts have been made to integrate SiRi with complementary-metal-oxide-semiconductor (CMOS) circuits to form a complete lab-on-chip (LOC). Integration of SiRi with CMOS will facilitate real time detection of the output signal and provide a compact small sized LOC. Here, we propose a novel pixel based SiRi device monolithically integrated with CMOS field-effect-transistors (FET) for real-time selective multiplexed detection. The SiRi pixels are fabricated on a silicon-on-insulator wafer using a top-down method. Each pixel houses a control FET, fluid-gate (FG) and SiRi sensor. The pixel is controlled by simultaneously applying frontgate (V-G) and backgate voltage (V-BG). The liquid potential can be monitored using the FG. We report the transfer characteristics (I-D-V-G) of N- and P-type SiRi pixels. Further, the I-D-V-G characteristics of the SiRis are studied at different V-BG. The application of V-BG to turn ON the SiRi modulates the subthreshold slope (SS) and threshold voltage (V-TH) of the control FET. Particularly, N-type pixels cannot be turned OFF due to the control NFET operating in the strong inversion regime. This is due to large V-BG (25 V) application to turn ON the SiRi sensor. Conversely, the P-type SiRi sensors do not require large V-BG to switch ON. Thus, P-type pixels exhibit excellent I-ON/I-OFF 10(6), SS of 70-80 mV/dec and V-TH of 0.5 V. These promising results will empower the large-scale cost-efficient production of SiRi based LOC sensors.
  •  
26.
  • Jin, Zhi Jiang, et al. (författare)
  • Cavitating flow through a micro-orifice
  • 2019
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 10:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Microfluidic systems have witnessed rapid development in recent years. As one of the most common structures, the micro-orifice is always included inside microfluidic systems. Hydrodynamic cavitation in the micro-orifice has been experimentally discovered and is harmful to microfluidic systems. This paper investigates cavitating flow through a micro-orifice. A rectangular micro-orifice with a l/d ratio varying from 0.25 to 4 was selected and the pressure difference between the inlet and outlet varied from 50 to 300 kPa. Results show that cavitation intensity increased with an increase in pressure difference. Decreasing exit pressure led to a decrease in cavitation number and cavitation could be prevented by increasing the exit pressure. In addition, the vapor cavity also increased with an increase in pressure difference and l/d ratio. Results also show the pressure ratio at cavitation inception was 1.8 when l/d was above 0.5 and the cavitation number almost remained constant when l/d was larger than 2. Moreover, there was an apparent difference in cavitation number depending on whether l/d was larger than 1.
  •  
27.
  • Johannsen, B, et al. (författare)
  • Automated Pre-Analytic Processing of Whole Saliva Using Magnet-Beating for Point-of-Care Protein Biomarker Analysis
  • 2019
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 10:12
  • Tidskriftsartikel (refereegranskat)abstract
    • Saliva offers many advantages for point-of-care (PoC) diagnostic applications due to non-invasive, easy, and cost-effective methods of collection. However, the complex matrix with its non-Newtonian behavior and high viscosity poses handling challenges. Several tedious and long pre-analytic steps, incompatible with PoC use, are required to liquefy and homogenize saliva samples before protein analysis can be performed. We apply magnet-beating to reduce hands-on time and to simplify sample preparation. A magnet in a chamber containing the whole saliva is actuated inside a centrifugal microfluidic cartridge by the interplay of centrifugal and magnetic forces. Rigorous mixing, which homogenizes the saliva sample, is then initiated. Consequently, fewer manual steps are required to introduce the whole saliva into the cartridge. After 4 min of magnet-beating, the processed sample can be used for protein analysis. The viscosity of whole saliva has been reduced from 10.4 to 2.3 mPa s. Immunoassay results after magnet-beating for three salivary periodontal markers (MMP-8, MMP-9, TIMP-1) showed a linear correlation with a slope of 0.99 when compared to results of reference method treated samples. Conclusively, magnet-beating has been shown to be a suitable method for the pre-analytic processing of whole saliva for fully automated PoC protein analysis.
  •  
28.
  • Kim, Anna A, et al. (författare)
  • Wafer-Scale Patterning of Protein Templates for Hydrogel Fabrication
  • 2021
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 12:11, s. 1386-1386
  • Tidskriftsartikel (refereegranskat)abstract
    • Human-induced pluripotent stem cell-derived cardiomyocytes are a potentially unlimited cell source and promising patient-specific in vitro model of cardiac diseases. Yet, these cells are limited by immaturity and population heterogeneity. Current in vitro studies aiming at better understanding of the mechanical and chemical cues in the microenvironment that drive cellular maturation involve deformable materials and precise manipulation of the microenvironment with, for example, micropatterns. Such microenvironment manipulation most often involves microfabrication protocols which are time-consuming, require cleanroom facilities and photolithography expertise. Here, we present a method to increase the scale of the fabrication pipeline, thereby enabling large-batch generation of shelf-stable microenvironment protein templates on glass chips. This decreases fabrication time and allows for more flexibility in the subsequent steps, for example, in tuning the material properties and the selection of extracellular matrix or cell proteins. Further, the fabrication of deformable hydrogels has been optimized for compatibility with these templates, in addition to the templates being able to be used to acquire protein patterns directly on the glass chips. With our approach, we have successfully controlled the shapes of cardiomyocytes seeded on Matrigel-patterned hydrogels.
  •  
29.
  • Koo, Kyo In, et al. (författare)
  • Acoustic cell patterning in hydrogel for three-dimensional cell network formation
  • 2021
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • In the field of engineered organ and drug development, three-dimensional network-structured tissue has been a long-sought goal. This paper presents a direct hydrogel extrusion process exposed to an ultrasound standing wave that aligns fibroblast cells to form a network structure. The frequency-shifted (2 MHz to 4 MHz) ultrasound actuation of a 400-micrometer square-shaped glass capillary that was continuously perfused by fibroblast cells suspended in sodium alginate generated a hydrogel string, with the fibroblasts aligned in single or quadruple streams. In the transition from the one-cell stream to the four-cell streams, the aligned fibroblast cells were continuously interconnected in the form of a branch and a junction. The ultrasound-exposed fibroblast cells displayed over 95% viability up to day 10 in culture medium without any significant difference from the unexposed fibroblast cells. This acoustofluidic method will be further applied to create a vascularized network by replacing fibroblast cells with human umbilical vein endothelial cells.
  •  
30.
  • Leosson, K., et al. (författare)
  • Integrated Biophotonics with CYTOP
  • 2012
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 3:1, s. 114-125
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe how the amorphous fluoropolymer CYTOP can be advantageously used as a waveguide cladding material in integrated optical circuits suitable for applications in integrated biophotonics. The unique refractive index of CYTOP (n = 1.34) enables the cladding material to be well index-matched to an optically probed sample solution. Furthermore, ultra-high index contrast waveguides can be fabricated, using conventional optical polymers as waveguide core materials, offering a route to large-scale integration of optical functions on a single chip. We discuss applications of this platform to evanescent-wave excitation fluorescence microscopy, passive and/or thermo-electrically-controlled on-chip light manipulation, on-chip light generation, and direct integration with microfluidic circuits through low-temperature bonding.
  •  
31.
  • Liu, Zhenhua, et al. (författare)
  • A Rapid Prototyping Technique for Microfluidics with High Robustness and Flexibility
  • 2016
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 7:11
  • Tidskriftsartikel (refereegranskat)abstract
    • In microfluidic device prototyping, master fabrication by traditional photolithography is expensive and time-consuming, especially when the design requires being repeatedly modified to achieve a satisfactory performance. By introducing a high-performance/cost-ratio laser to the traditional soft lithography, this paper describes a flexible and rapid prototyping technique for microfluidics. An ultraviolet (UV) laser directly writes on the photoresist without a photomask, which is suitable for master fabrication. By eliminating the constraints of fixed patterns in the traditional photomask when the masters are made, this prototyping technique gives designers/researchers the convenience to revise or modify their designs iteratively. A device fabricated by this method is tested for particle separation and demonstrates good properties. This technique provides a flexible and rapid solution to fabricating microfluidic devices for non-professionals at relatively low cost.
  •  
32.
  • Loskutova, Ksenia, et al. (författare)
  • Measuring the Compressibility of Cellulose Nanofiber-Stabilized Microdroplets Using Acoustophoresis
  • 2021
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 12:12, s. 1465-
  • Tidskriftsartikel (refereegranskat)abstract
    • Droplets with a liquid perfluoropentane core and a cellulose nanofiber shell have the potential to be used as drug carriers in ultrasound-mediated drug delivery. However, it is necessary to understand their mechanical properties to develop ultrasound imaging sequences that enable in vivo imaging of the vaporization process to ensure optimized drug delivery. In this work, the compressibility of droplets stabilized with cellulose nanofibers was estimated using acoustophoresis at three different acoustic pressures. Polyamide particles of known size and material properties were used for calibration. The droplet compressibility was then used to estimate the cellulose nanofiber bulk modulus and compare it to experimentally determined values. The results showed that the acoustic contrast factor for these droplets was negative, as the droplets relocated to pressure antinodes during ultrasonic actuation. The droplet compressibility was 6.6-6.8 x10(-10) Pa-1, which is higher than for water (4.4x10(-10) Pa-1) but lower than for pure perfluoropentane (2.7x10(-9) Pa-1). The compressibility was constant across different droplet diameters, which was consistent with the idea that the shell thickness depends on the droplet size, rather than being constant.
  •  
33.
  • Norris, Karl, et al. (författare)
  • Marine Polysaccharide-Collagen Coatings on Ti6Al4V Alloy Formed by Self-Assembly
  • 2019
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Polysaccharides of marine origin are gaining interest as biomaterial components. Bacteria derived from deep-sea hydrothermal vents can produce sulfated exopolysaccharides (EPS), which can influence cell behavior. The use of such polysaccharides as components of organic, collagen fibril-based coatings on biomaterial surfaces remains unexplored. In this study, collagen fibril coatings enriched with HE800 and GY785 EPS derivatives were deposited on titanium alloy (Ti6Al4V) scaffolds produced by rapid prototyping and subjected to physicochemical and cell biological characterization. Coatings were formed by a self-assembly process whereby polysaccharides were added to acidic collagen molecule solution, followed by neutralization to induced self-assembly of collagen fibrils. Fibril formation resulted in collagen hydrogel formation. Hydrogels formed directly on Ti6Al4V surfaces, and fibrils adsorbed onto the surface. Scanning electron microscopy (SEM) analysis of collagen fibril coatings revealed association of polysaccharides with fibrils. Cell biological characterization revealed good cell adhesion and growth on bare Ti6Al4V surfaces, as well as coatings of collagen fibrils only and collagen fibrils enhanced with HE800 and GY785 EPS derivatives. Hence, the use of both EPS derivatives as coating components is feasible. Further work should focus on cell differentiation.
  •  
34.
  • Olofsson, Karl, et al. (författare)
  • Ultrasonic Based Tissue Modelling and Engineering
  • 2018
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 9:11
  • Forskningsöversikt (refereegranskat)abstract
    • Systems and devices for in vitro tissue modelling and engineering are valuable tools, which combine the strength between the controlled laboratory environment and the complex tissue organization and environment in vivo. Device-based tissue engineering is also a possible avenue for future explant culture in regenerative medicine. The most fundamental requirements on platforms intended for tissue modelling and engineering are their ability to shape and maintain cell aggregates over long-term culture. An emerging technology for tissue shaping and culture is ultrasonic standing wave (USW) particle manipulation, which offers label-free and gentle positioning and aggregation of cells. The pressure nodes defined by the USW, where cells are trapped in most cases, are stable over time and can be both static and dynamic depending on actuation schemes. In this review article, we highlight the potential of USW cell manipulation as a tool for tissue modelling and engineering.
  •  
35.
  • Olofsson, Karl, et al. (författare)
  • Ultrasound-Based Scaffold-Free Core-Shell Multicellular Tumor Spheroid Formation
  • 2021
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 12:3
  • Tidskriftsartikel (refereegranskat)abstract
    • In cancer research and drug screening, multicellular tumor spheroids (MCTSs) are a popular model to bridge the gap between in vitro and in vivo. However, the current techniques to culture mixed co-culture MCTSs do not mimic the structural architecture and cellular spatial distribution in solid tumors. In this study we present an acoustic trapping-based core-shell MCTSs culture method using sequential seeding of the core and shell cells into microwells coated with a protein repellent coating. Scaffold-free core-shell ovarian cancer OVCAR-8 cell line MCTSs were cultured, stained, cleared and confocally imaged on-chip. Image analysis techniques were used to quantify the shell thickness (23.2 +/- 1.8 mu m) and shell coverage percentage (91.2 +/- 2.8%). We also show that the shell thickness was evenly distributed over the MCTS cores with the exception of being slightly thinner close to the microwell bottom. This scaffold-free core-shell MCTSs formation technique and the analysis tools presented herein could be used as an internal migration assay within the MCTS or to form core-shell MCTS co-cultures to study therapy response or the interaction between tumor and stromal cells.
  •  
36.
  • Pereira, Fabio M., et al. (författare)
  • Hybrid Microfluidic Platform for Multifactorial Analysis Based on Electrical Impedance, Refractometry, Optical Absorption and Fluorescence
  • 2016
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 7:10
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes the development of a novel microfluidic platform for multifactorial analysis integrating four label-free detection methods: electrical impedance, refractometry, optical absorption and fluorescence. We present the rationale for the design and the details of the microfabrication of this multifactorial hybrid microfluidic chip. The structure of the platform consists of a three-dimensionally patterned polydimethylsiloxane top part attached to a bottom SU-8 epoxy-based negative photoresist part, where microelectrodes and optical fibers are incorporated to enable impedance and optical analysis. As a proof of concept, the chip functions have been tested and explored, enabling a diversity of applications: (i) impedance-based identification of the size of micro beads, as well as counting and distinguishing of erythrocytes by their volume or membrane properties; (ii) simultaneous determination of the refractive index and optical absorption properties of solutions; and (iii) fluorescence-based bead counting.
  •  
37.
  • Pishbin, E., et al. (författare)
  • The effect of moment of inertia on the liquids in centrifugal microfluidics
  • 2016
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 7:12
  • Tidskriftsartikel (refereegranskat)abstract
    • The flow of liquids in centrifugal microfluidics is unidirectional and dominated by centrifugal and Coriolis forces (i.e., effective only at T-junctions). Developing mechanisms and discovering efficient techniques to propel liquids in any direction other than the direction of the centrifugal force has been the subject of a large number of studies. The capillary force attained by specific surface treatments, pneumatic energy, active and passive flow reciprocation and Euler force have been previously introduced in order to manipulate the liquid flow and push it against the centrifugal force. Here, as a new method, the moment of inertia of the liquid inside a chamber in a centrifugal microfluidic platform is employed to manipulate the flow and propel the liquid passively towards the disc center. Furthermore, the effect of the moment of inertia on the liquid in a rectangular chamber is evaluated, both in theory and experiments, and the optimum geometry is defined. As an application of the introduced method, the moment of inertia of the liquid is used in order to mix two different dyed deionized (DI) waters; the mixing efficiency is evaluated and compared to similar mixing techniques. The results show the potential of the presented method for pumping liquids radially inward with relatively high flow rates (up to 23 mm3/s) and also efficient mixing in centrifugal microfluidic platforms.
  •  
38.
  • Pranzo, Daniela, et al. (författare)
  • Extrusion-Based 3D Printing of Microfluidic Devices for Chemical and Biomedical Applications: A Topical Review
  • 2018
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 9:8
  • Forskningsöversikt (refereegranskat)abstract
    • One of the most widespread additive manufacturing (AM) technologies is fused deposition modelling (FDM), also known as fused filament fabrication (FFF) or extrusion-based AM. The main reasons for its success are low costs, very simple machine structure, and a wide variety of available materials. However, one of the main limitations of the process is its accuracy and finishing. In spite of this, FDM is finding more and more applications, including in the world of micro-components. In this world, one of the most interesting topics is represented by microfluidic reactors for chemical and biomedical applications. The present review focusses on this research topic from a process point of view, describing at first the platforms and materials and then deepening the most relevant applications.
  •  
39.
  • Prochazka, Lukas, et al. (författare)
  • Novel Fabrication Technology for Clamped Micron-Thick Titanium Diaphragms Used for the Packaging of an Implantable MEMS Acoustic Transducer
  • 2022
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Micro-Electro-Mechanical Systems (MEMS) acoustic transducers are highly sophisticated devices with high sensing performance, small size, and low power consumption. To be applied in an implantable medical device, they require a customized packaging solution with a protecting shell, usually made from titanium (Ti), to fulfill biocompatibility and hermeticity requirements. To allow acoustic sound to be transferred between the surroundings and the hermetically sealed MEMS transducer, a compliant diaphragm element needs to be integrated into the protecting enclosure. In this paper, we present a novel fabrication technology for clamped micron-thick Ti diaphragms that can be applied on arbitrary 3D substrate geometry and hence directly integrated into the packaging structure. Stiffness measurements on various diaphragm samples illustrate that the technology enables a significant reduction of residual stress in the diaphragm developed during its deposition on a polymer sacrificial material.
  •  
40.
  • Puglisi, Donatella, 1980-, et al. (författare)
  • Silicon Carbide Microstrip Radiation Detectors
  • 2019
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 10:12
  • Tidskriftsartikel (refereegranskat)abstract
    • Compared with the most commonly used silicon and germanium, which need to work at cryogenic or low temperatures to decrease their noise levels, wide-bandgap compound semiconductors such as silicon carbide allow the operation of radiation detectors at room temperature, with high performance, and without the use of any bulky and expensive cooling equipment. In this work, we investigated the electrical and spectroscopic performance of an innovative position-sensitive semiconductor radiation detector in epitaxial 4H-SiC. The full depletion of the epitaxial layer (124 µm, 5.2 × 1013 cm−3) was reached by biasing the detector up to 600 V. For comparison, two different microstrip detectors were fully characterized from −20 °C to +107 °C. The obtained results show that our prototype detector is suitable for high resolution X-ray spectroscopy with imaging capability in a wide range of operating temperatures.
  •  
41.
  • Qiu, Wenjun, et al. (författare)
  • A Contact Angle Study of the Interaction between Embedded Amphiphilic Molecules and the PDMS Matrix in an Aqueous Environment
  • 2014
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 5:3, s. 515-527
  • Tidskriftsartikel (refereegranskat)abstract
    • Poly(dimethylsiloxane) (PDMS) surface modification via gradient-induced transport of embedded amphiphilic molecules is a novel, easy, flexible, and environmentally friendly approach for reducing protein adsorption on PDMS in microfluidic applications. To better understand the processing and the potential use in the viability-sensitive applications such as manipulation and culturing of primary neural cells, we systematically investigate how embedded molecules interact with a PDMS matrix and its surface in aqueous environments by studying the wetting angle over time under various processing conditions, including water exposure time, water exposure temperature, curing master materials, in addition to comparing different embedded amphiphilic molecules. The results indicate that the water exposure time clearly plays an important role in the surface properties. Our interpretation is that molecular rearrangement of the surface-embedded molecules improves surface coverage in the short term; while over a longer period, the transport of molecules embedded in the bulk enhance its coverage. However, this improvement finally terminates when molecules transported from the bulk to the surface are not sufficient to replace the molecules leaching into the water.
  •  
42.
  • Radamson, Henry H., et al. (författare)
  • Miniaturization of CMOS
  • 2019
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 10:5
  • Tidskriftsartikel (refereegranskat)abstract
    • When the international technology roadmap of semiconductors (ITRS) started almost five decades ago, the metal oxide effect transistor (MOSFET) as units in integrated circuits (IC) continuously miniaturized. The transistor structure has radically changed from its original planar 2D architecture to today's 3D Fin field-effect transistors (FinFETs) along with new designs for gate and source/drain regions and applying strain engineering. This article presents how the MOSFET structure and process have been changed (or modified) to follow the More Moore strategy. A focus has been on methodologies, challenges, and difficulties when ITRS approaches the end. The discussions extend to new channel materials beyond the Moore era.
  •  
43.
  • Saeidi, Davood, et al. (författare)
  • A Quantitative Study of the Secondary Acoustic Radiation Force on Biological Cells during Acoustophoresis
  • 2020
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 11:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We investigate cell-particle secondary acoustic radiation forces in a plain ultrasonic standing wave field inside a microfluidic channel. The effect of secondary acoustic radiation forces on biological cells is measured in a location between a pressure node and a pressure anti-node and the result is compared with theory by considering both compressibility and density dependent effects. The secondary acoustic force between motile red blood cells (RBCs) and MCF-7 cells and fixed 20 mu m silica beads is investigated in a half-wavelength wide microchannel actuated at 2 MHz ultrasonic frequency. Our study shows that the secondary acoustic force between cells in acoustofluidic devices could play an important role for cell separation, sorting, and trapping purposes. Our results also demonstrate the possibility to isolate individual cells at trapping positions provided by silica beads immobilized and adhered to the microchannel bottom. We conclude that during certain experimental conditions, the secondary acoustic force acting on biological cells can dominate over the primary acoustic radiation force, which could open up for new microscale acoustofluidic methods.
  •  
44.
  • Thorne, Nicolas, et al. (författare)
  • Systematic Review: Microfluidics and Plasmodium
  • 2021
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 12:10
  • Forskningsöversikt (refereegranskat)abstract
    • Malaria affects 228 million people worldwide each year, causing severe disease and worsening the conditions of already vulnerable populations. In this review, we explore how malaria has been detected in the past and how it can be detected in the future. Our primary focus is on finding new directions for low-cost diagnostic methods that unspecialized personnel can apply in situ. Through this review, we show that microfluidic devices can help pre-concentrate samples of blood infected with malaria to facilitate the diagnosis. Importantly, these devices can be made cheaply and be readily deployed in remote locations.
  •  
45.
  • Tripon-Canseliet, Charlotte, et al. (författare)
  • Experimental microwave complex conductivity extraction of vertically aligned MWCNT bundles for microwave subwavelength antenna design
  • 2019
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 10:9
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper reports the extraction of electrical impedance at microwave frequencies of vertically aligned multi-wall carbon nanotubes (VA MWCNT) bundles/forests grown on a silicon substrate. Dedicated resonating devices were designed for antenna application, operating around 10 GHz and benefiting from natural inductive/capacitive behavior or complex conductivity in the microwave domain. As obtained from S-parameters measurements, the capacitive and inductive behaviors of VA MWCNT bundles were deduced from device frequency resonance shift.
  •  
46.
  • Urbansky, Anke, et al. (författare)
  • Affinity-bead-mediated enrichment of CD8+ lymphocytes from peripheral blood progenitor cell products using acoustophoresis
  • 2016
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 7:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Acoustophoresis is a technique that applies ultrasonic standing wave forces in a microchannel to sort cells depending on their physical properties in relation to the surrounding media. Cell handling and separation for research and clinical applications aims to efficiently separate specific cell populations. Here, we investigated the sorting of CD8 lymphocytes from peripheral blood progenitor cell (PBPC) products by affinity-bead-mediated acoustophoresis. PBPC samples were obtained from healthy donors (n = 4) and patients (n = 18). Mononuclear cells were labeled with anti-CD8-coated magnetic beads and sorted on an acoustophoretic microfluidic device and by standard magnetic cell sorting as a reference method. CD8 lymphocytes were acoustically sorted with a mean purity of 91% ± 8% and a median separation efficiency of 63% (range 15.1%-90.5%) as compared to magnetic sorting (purity 91% ± 14%, recovery 29% (range 5.1%-47.3%)). The viability as well as the proliferation capacity of sorted lymphocytes in the target fraction were unimpaired and, furthermore, hematopoietic progenitor cell assay revealed a preserved clonogenic capacity post-sorting. Bead-mediated acoustophoresis can, therefore, be utilized to efficiently sort less frequent CD8+ lymphocytes from PBPC products in a continuous flow mode while maintaining cell viability and functional capacity of both target and non-target fractions.
  •  
47.
  • Vyas, Agin, 1992, et al. (författare)
  • A micromachined coupled-cantilever for piezoelectric energy harvesters
  • 2018
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 9:5
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a demonstration of the feasibility of fabricating micro-cantilever harvesters with extended stress distribution and enhanced bandwidth by exploiting an M-shaped two-degrees-of-freedom design. The measured mechanical response of the fabricated device displays the predicted dual resonance peak behavior with the fundamental peak at the intended frequency. This design has the features of high energy conversion efficiency in a miniaturized environment where the available vibrational energy varies in frequency. It makes such a design suitable for future large volume production of integrated self powered sensors nodes for the Internet-of-Things
  •  
48.
  • Wang, Zhiqi, et al. (författare)
  • Topology Optimization of Passive Cell Traps
  • 2021
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 12:7
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper discusses a flexible design method of cell traps based on the topology optimization of fluidic flows. Being different from the traditional method, this method obtains the periodic layout of the cell traps according to the cell trapping requirements by proposing a topology optimization model. Additionally, it satisfies the cell trapping function by restricting the flow distribution while taking into account the overall energy dissipation of the flow field. The dependence on the experience of the designer is reduced when this method is used to design a cell trap with acceptable trapping performance. By comparing the influence of the changes of various parameters on the optimization results, the flexibility of the topology optimization method for cell trap structure optimization is verified. The capability of this design method is validated by several performed comparisons between the obtained layouts and optimized designs in the published literature.
  •  
49.
  • Wiklund, Martin, et al. (författare)
  • Ultrasound-Induced Cell-Cell Interaction Studies in a Multi-Well Microplate
  • 2014
  • Ingår i: Micromachines. - : MDPI AG. - 2072-666X. ; 5:1, s. 27-49
  • Forskningsöversikt (refereegranskat)abstract
    • This review describes the use of ultrasound for inducing and retaining cell-cell contact in multi-well microplates combined with live-cell fluorescence microscopy. This platform has been used for studying the interaction between natural killer (NK) cells and cancer cells at the level of individual cells. The review includes basic principles of ultrasonic particle manipulation, design criteria when building a multi-well microplate device for this purpose, biocompatibility aspects, and finally, two examples of biological applications: Dynamic imaging of the inhibitory immune synapse, and studies of the heterogeneity in killing dynamics of NK cells interacting with cancer cells.
  •  
50.
  • Yuan, Wei, et al. (författare)
  • An Experimental Study of Micro-Dimpled Texture in Friction Control under Dry and Lubricated Conditions
  • 2022
  • Ingår i: Micromachines. - : MDPI. - 2072-666X. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Friction control is a vital technology for reaching sustainable development goals, and surface texturing is one of the most effective and efficient techniques for friction reduction. This study investigated the performance of a micro-dimpled texture under varying texture densities and experimental conditions. Reciprocating sliding tests were performed to evaluate the effects of the micro-dimpled texture on friction reduction under different normal loads and lubrication conditions. The results suggested that a micro-dimpled texture could reduce the coefficient of friction (CoF) under dry and lubricated conditions, and high dimple density results in a lower CoF. The dominant mechanism of the micro-dimpled texture's effect on friction reduction was discussed, and surface observation and simulation suggested that a micro-dimpled texture could reduce the contact area at the friction interface, thereby reducing CoF.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-50 av 79
Typ av publikation
tidskriftsartikel (68)
forskningsöversikt (11)
Typ av innehåll
refereegranskat (75)
övrigt vetenskapligt/konstnärligt (4)
Författare/redaktör
Wiklund, Martin (5)
van Noort, Danny (3)
Laurell, Thomas (3)
Jönsson, Håkan, PhD, ... (3)
Adiels, Caroline B., ... (2)
Goksör, Mattias, 197 ... (2)
visa fler...
Radamson, Henry H. (2)
Enoksson, Peter, 195 ... (2)
Unger, Eva (1)
Abafogi, Abdurhaman ... (1)
Kim, Jaewon (1)
Lee, Jinyeop (1)
Park, Sungsu (1)
Russom, Aman, Prof. ... (1)
Ghorbani, Morteza (1)
Kosar, Ali (1)
Grishenkov, Dmitry, ... (1)
Ahmadpour, Doryaneh, ... (1)
Abbaszadehbanaeiyan, ... (1)
Abdullah, Saad (1)
Liu, Yang (1)
Östling, Mikael (1)
Jayakumar, Ganesh (1)
Hellström, Per-Erik, ... (1)
Tenje, Maria (1)
Roxhed, Niclas (1)
Khan, S (1)
Vomiero, Alberto (1)
Lundgren, Per, 1968 (1)
Li, Yan (1)
Teramura, Yuji (1)
Nilsson Ekdahl, Kris ... (1)
Nilsson, Bo (1)
Johansson, Ulf (1)
Sandegren, Linus (1)
Mattiasson, Bo (1)
Bostanci, N (1)
Mitsakakis, K (1)
Afrasiabi, Roodabeh (1)
Björk, Per (1)
Söderberg, Lovisa M. (1)
Svahn Andersson, Hel ... (1)
Linnros, Jan, 1953- (1)
Raja, S. (1)
Agnarsson, Björn, 19 ... (1)
Leosson, K. (1)
Liu, Zhenhua, 1992- (1)
Fornell, Anna (1)
Karlsson, Magnus, 19 ... (1)
Ainla, Alar, 1982 (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (25)
Chalmers tekniska högskola (15)
Lunds universitet (13)
Linköpings universitet (12)
Uppsala universitet (7)
RISE (6)
visa fler...
Karolinska Institutet (6)
Mittuniversitetet (4)
Karlstads universitet (3)
Göteborgs universitet (2)
Umeå universitet (1)
Luleå tekniska universitet (1)
Mälardalens universitet (1)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (79)
Forskningsämne (UKÄ/SCB)
Teknik (45)
Naturvetenskap (32)
Medicin och hälsovetenskap (12)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy