SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:2364 3722 "

Sökning: L773:2364 3722

  • Resultat 1-15 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Gustafsson, Arvid, et al. (författare)
  • Antibiotic prophylaxis and post-procedure infectious complications in endoscopic retrograde cholangiopancreatography with peroral cholangioscopy.
  • 2023
  • Ingår i: Endoscopy international open. - : Georg Thieme Verlag KG. - 2364-3722. ; 11:12, s. E1177-E1183
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and study aims: Single-operator peroral cholangioscopy (SOC) has gained increasing attention in modern biliary and pancreatic therapy and diagnosis. This procedure has shown higher rates of infectious complications than conventional endoscopic retrograde cholangiopancreatography (ERCP); therefore, many guidelines recommend antibiotic prophylaxis (AP). However, whether AP administration decreases infectious or overall adverse events (AEs) has been little studied. We aimed to study whether AP affects post-procedure infectious or overall AEs in ERCP with SOC.Patients and methods: We collected data from the Swedish Registry for Gallstone Surgery and ERCP (GallRiks). Of the 124,921 extracted ERCP procedures performed between 2008 and 2021, 1,605 included SOC and represented the study population. Exclusion criteria were incomplete 30-day follow-up, ongoing antibiotic use, and procedures with unspecified indication. Type and dose of antibiotics were not reported. Post-procedure infectious complications and AEs at 30-day follow-up were the main outcomes.Results: AP was administered to 1,307 patients (81.4%). In this group, 3.4% of the patients had infectious complications compared with 3.7% in the non-AP group. The overall AE rates in the AP and non-AP groups were 14.6% and 15.2%, respectively. The incidence of cholangitis was 3.1% in the AP group and 3.4% in the non-AP group. Using multivariable analysis, both infectious complications (odds ratio [OR] 0.92, 95% confidence interval [CI] 0.54-1.57) and AEs (OR 0.87, 95% CI 0.65-1.16) remained unaffected by AP administration.Conclusions: No reduction in infectious complication rates and AEs was seen with AP administration for SOC. The continued need for AP in SOC remains uncertain.
  •  
6.
  • Hansdotter, Ida, et al. (författare)
  • Hill classification is superior to the axial length of a hiatal hernia for assessment of the mechanical anti-reflux barrier at the gastroesophageal junction
  • 2016
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 4:3, s. E311-E317
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and study aims: The pathogenesis of gastroesophageal reflux disease (GERD) is multifactorial, including the mechanical anti-reflux barrier of the gastroesophageal junction. This barrier can be evaluated endoscopically in two ways: by measuring the axial length of any hiatal hernia present or by assessing the gastroesophageal flap valve. The endoscopic measurement of axial length is troublesome because of the physiological dynamics in the area. Grading the gastroesophageal flap valve is easier and has proven reproducible. The aim of the present study was to compare the two endoscopic grading methods with regard to associations with GERD. Patients and methods: Population-based subjects underwent endoscopic examination assessing the axial length of hiatus hernia, the gastroesophageal flap valve using the Hill classification, esophagitis using the Los Angeles (LA) classification, and columnar metaplasia using the Z-line appearance (ZAP) classification. Biopsies were taken from the squamocolumnar junction to assess the presence of intestinal metaplasia. Symptoms were recorded with the validated Abdominal Symptom Questionnaire. GERD was defined according to the Montreal definition. Results: In total, 334 subjects were included in the study and underwent endoscopy; 86 subjects suffered from GERD and 211 presented no symptoms or signs of GERD. Based on logistic regression, the estimated area under the curve statistic (AUC) for Hill (0.65 [95 % CI 0.59-0.72]) was higher than the corresponding estimate for the axial length of a hiatal hernia (0.61 [95 % CI 0.54-0.68]), although the difference was not statistically significant (P=0.225). Conclusion: From our data, and in terms of association with GERD, the Hill classification was slightly stronger compared to the axial length of a hiatal hernia, but we could not verify that the Hill classification was superior as a predictor. The Hill classification may replace the axial length of a hiatal hernia in the endoscopic assessment of the mechanical anti-reflux barrier of the gastroesophageal junction.
  •  
7.
  • Koulaouzidis, Anastasios, et al. (författare)
  • KID Project : an internet-based digital video atlas of capsule endoscopy for research purposes
  • 2017
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 5:6, s. 477-483
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND AIMS: Capsule endoscopy (CE) has revolutionized small-bowel (SB) investigation. Computational methods can enhance diagnostic yield (DY); however, incorporating machine learning algorithms (MLAs) into CE reading is difficult as large amounts of image annotations are required for training. Current databases lack graphic annotations of pathologies and cannot be used. A novel database, KID, aims to provide a reference for research and development of medical decision support systems (MDSS) for CE.METHODS: Open-source software was used for the KID database. Clinicians contribute anonymized, annotated CE images and videos. Graphic annotations are supported by an open-access annotation tool (Ratsnake). We detail an experiment based on the KID database, examining differences in SB lesion measurement between human readers and a MLA. The Jaccard Index (JI) was used to evaluate similarity between annotations by the MLA and human readers.RESULTS: The MLA performed best in measuring lymphangiectasias with a JI of 81 ± 6 %. The other lesion types were: angioectasias (JI 64 ± 11 %), aphthae (JI 64 ± 8 %), chylous cysts (JI 70 ± 14 %), polypoid lesions (JI 75 ± 21 %), and ulcers (JI 56 ± 9 %).CONCLUSION: MLA can perform as well as human readers in the measurement of SB angioectasias in white light (WL). Automated lesion measurement is therefore feasible. KID is currently the only open-source CE database developed specifically to aid development of MDSS. Our experiment demonstrates this potential.
  •  
8.
  • Koulaouzidis, Anastasios, et al. (författare)
  • Novel experimental and software methods for image reconstruction and localization in capsule endoscopy
  • 2018
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 6:2, s. 205-210
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and study aims : Capsule endoscopy (CE) is invaluable for minimally invasive endoscopy of the gastrointestinal tract; however, several technological limitations remain including lack of reliable lesion localization. We present an approach to 3D reconstruction and localization using visual information from 2D CE images.Patients and methods : Colored thumbtacks were secured in rows to the internal wall of a LifeLike bowel model. A PillCam SB3 was calibrated and navigated linearly through the lumen by a high-precision robotic arm. The motion estimation algorithm used data (light falling on the object, fraction of reflected light and surface geometry) from 2D CE images in the video sequence to achieve 3D reconstruction of the bowel model at various frames. The ORB-SLAM technique was used for 3D reconstruction and CE localization within the reconstructed model. This algorithm compared pairs of points between images for reconstruction and localization.Results: As the capsule moved through the model bowel 42 to 66 video frames were obtained per pass. Mean absolute error in the estimated distance travelled by the CE was 4.1 ± 3.9 cm. Our algorithm was able to reconstruct the cylindrical shape of the model bowel with details of the attached thumbtacks. ORB-SLAM successfully reconstructed the bowel wall from simultaneous frames of the CE video. The "track" in the reconstruction corresponded well with the linear forwards-backwards movement of the capsule through the model lumen.Conclusion: The reconstruction methods, detailed above, were able to achieve good quality reconstruction of the bowel model and localization of the capsule trajectory using information from the CE video and images alone.
  •  
9.
  • Olsson, Greger, et al. (författare)
  • Preoperative biliary drainage by plastic or self-expandable metal stents in patients with periampullary tumors : results of a randomized clinical study.
  • 2017
  • Ingår i: Endoscopy international open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 5:9, s. E798-E808
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND STUDY AIMS : Preoperative biliary drainage in patients with periampullary tumors and jaundice has been popularized to improve the quality of life and minimize the risks associated with subsequent radical surgery. The aim of this study was to investigate the possible superiority of self-expandable metal stents (SEMS) over plastic stents, by comparing the amount of bacteria in intraoperatively collected bile and using this variable as a proxy for the efficacy of the respective biliary drainage modalities.PATIENTS AND METHODS : In this randomized clinical trial, 92 patients with obstructive jaundice were enrolled; 45 were allocated to the plastic stent group and 47 to the SEMS group. The primary outcome was the extent and magnitude of biliary bacterial growth at the time of surgical exploration. Secondary outcomes were: macroscopic grading of inflammation of the stented bile ducts, occurrence of adverse events after stenting, stent dysfunction, recognized surgical complexities, and incidence of postoperative complications.RESULTS:  = 0.03). Postoperative complications in patients who underwent curative surgery were more common in patients with plastic stents (72 % vs. 52 %), among which clinically significant leakage from the pancreatic anastomoses seemed to predominate (12 % vs. 3.7 %); however, none of these differences in postoperative adverse events reached statistical significance.CONCLUSION:  This randomized clinical study was unable to demonstrate any superiority of SEMS in the efficacy of preoperative bile drainage, as assessed by the amount of bacteria in the intraoperatively collected bile. However, some data in favor of SEMS were observed among the clinical secondary outcomes variables (preoperative stent exchange rates) without increases in local inflammatory reactions.
  •  
10.
  •  
11.
  • Rönnow, Carl-Fredrik, et al. (författare)
  • Endoscopic submucosal dissection of 301 large colorectal neoplasias : outcome and learning curve from a specialized center in Europe
  • 2018
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 6:11, s. 1340-1348
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and study aims Endoscopic submucosal dissection (ESD) allows en bloc resection of large colorectal lesions but ESD experience is limited outside Asia. This study evaluated implementation of ESD in the treatment of colorectal neoplasia in a Western center. Patients and methods Three hundred and one cases of colorectal ESD (173 rectal and 128 colonic lesions) were retrospectively evaluated in terms of outcome, learning curve and complications. Results Median size was 4 cm (range 1 - 12.5). En bloc resection was achieved in 241 cases amounting to an en bloc resection rate of 80 %. R0 resection was accomplished in 207 cases (69 %), RX and R1 were attained in 83 (27 %) and 11 (4 %) cases, respectively. Median time was 98 min (range 10 - 588) and median proficiency was 7.2 cm 2 /h. Complications occurred in 24 patients (8 %) divided into 12 immediate perforations, five delayed perforations, one immediate bleeding and six delayed bleedings. Six patients (2 %), all with proximal lesions, had emergency surgery. Two hundred and four patients were followed up endoscopically and median follow-up time was 13 months (range 3 - 53) revealing seven recurrences (3 %). En bloc rate improved gradually from 60 % during the first period to 98 % during the last period. ESD proficiency significantly improved between the first study period (3.6 cm 2 /h) and the last study period (10.8 cm 2 /h). Conclusions This study represents the largest material on colorectal ESD in the west and shows that colorectal ESD can be implemented in clinical routine in western countries after appropriate training and achieve a high rate of en bloc and R0 resection with a concomitant low incidence of complications. ESD of proximal colonic lesions should be attempted with caution during the learning curve because of higher risk of complications.
  •  
12.
  • Rönnow, Carl-Fredrik, et al. (författare)
  • Endoscopic submucosal dissection of malignant non-pedunculated colorectal lesions
  • 2018
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 6:8, s. 961-968
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and study aimsEndoscopic submucosal dissection (ESD) is an established method for en bloc resection of large non-pedunculated colorectal lesions in Asia but dissemination of ESD in Western countries is limited. The aim of this study was to evaluate the role of ESD in the management of malignant non-pedunculated colorectal lesions in a European center.Patients and methods Among 255 patients undergoing colorectal ESD between 2014 and 2016, 29 cases were identified as submucosal invasive cancers and included in this study. The main outcomes were en bloc, R0 and curative resection as well as procedural time, complications and recurrence.Results Median tumor size was 40 mm (range 20 – 70 mm). Thirteen cancers were located in the colon and 16 were located in the rectum. Procedural time was 89 minutes (range 18 – 594 minutes). Complete resection was achieved in 28 cases, en bloc and R0 resection rates were 83 % and 69 %, respectively. Curative resection rate was 38 %. One case had a perforation in the sigmoid colon requiring emergency surgery. No significant bleeding occurred. Six patients underwent additional surgery after ESD, one of whom had residual tumor. One recurrence was detected in 20 patients that were followed-up endoscopically, median follow-up time was 13 months (range 2 – 30 months).Conclusion ESD seems to be a safe and effective method for treating non-pedunculated malignant colorectal lesions after careful patient selection and proper endoscopic training.
  •  
13.
  • Schult, A. L., et al. (författare)
  • Colonoscopy quality improvement after initial training: A cross-sectional study of intensive short-term training
  • 2023
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2364-3722 .- 2196-9736. ; 11:01
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and study aims High-quality is crucial for the effectiveness of colonoscopy and can be achieved by high-quality training and verified with assessment of key performance indicators (KPIs) for colonoscopy such as cecum intubation rate (CIR), adenoma detection rate (ADR) and adequate polyp resection. Typically, trainees achieve adequate CIR after 275 procedures, but little is known about learning curves for KPIs after initial training.Methods This cross-sectional study includes work-up colonoscopies after a positive screening test with fecal occult blood testing (FIT) or sigmoidoscopy, performed by either trainees after 300 training colonoscopies or by consultants. Outcome measures were KPIs. We assessed inter-endoscopist variation in trainees and learning curves for trainees as a group. We also compared KPIs for trainees and consultants as a group.Results Data from 6,655 colonoscopies performed by 21 trainees and 921 colonoscopies performed by 17 consultants were included. Most trainees achieved target standards for main KPIs. With time, trainees shortened cecum intubation time and withdrawal time without decreasing their ADR, reduced the proportion of painful colonoscopies, and increased the adequate polyp resection rate (all P < 0.01). Compared to consultants, trainees had higher CIR (97.7 % vs. 96.3 %, P = 0.02), ADR after positive FIT (57.6 % vs. 50.3 %, P < 0.01), and proximal ADR after sigmoidoscopy screening (41.1 % vs. 29.8 %; P < 0.01), higher adequate polyp resection rate (94.9 % vs. 93.1 %, P = 0.01) and fewer serious adverse events (0.65 % vs. 1.41 %, P = 0.02).Conclusions Trainees performed high-quality colonoscopies and achieved international target standards. Several KPIs continuously improved after initial training. Trainees outperformed consultants on several KPIs.
  •  
14.
  •  
15.
  • Tribonias, George, et al. (författare)
  • How familiar are we with decision-making concerning the treatment of perforation after endoscopic mucosal resection (EMR) in the colon? A case report
  • 2018
  • Ingår i: Endoscopy International Open. - : Georg Thieme Verlag KG. - 2196-9736 .- 2364-3722. ; 6:3, s. E308-E312
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and study aims We describe a case of perforation after colonic endoscopic mucosal resection (EMR) that was treated conservatively. We would like to highlight the importance of decision-making mainly based on the endoscopists point of view in combination with the surgical consultation. Although the radiological imaging is always needed, it cannot solely lead to a decision for operation. Intraperitoneal gas in computed tomography is not always associated with a hole in the endoscopic field and could be possibly explained from a "balloon" phenomenon. The amount of extraluminal air after an EMR does not correlate reciprocally with patients pain after the procedure. Even though perforation is a radiological diagnosis and endoscopists should be aware of the common post-EMR radiological findings, the surgical examination is mandatory and should be coupled with the endoscopic opinion in order to guide appropriately the treatment in patients with acute pain.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-15 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy