SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:9781467356848 "

Sökning: L773:9781467356848

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Svanström, Erika, et al. (författare)
  • Combined physical and statistical modeling of laser induced ultrasound signals from thin light absorbing films
  • 2013
  • Ingår i: 2013 IEEE International Ultrasonics Symposium. - Piscataway, NJ : IEEE Communications Society. - 9781467356848 ; , s. 2167-2170
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a method for predicting the ultrasound pulses generated by thin semi-transparent polymer films, excited by a short laser pulse. The acoustic pressure is first modeled based on the physical properties of the polymer. Partial Least-Squares Regression is then used to link the model pressure to the ultrasound pulses measured by an ultrasound transducer. The uncertainty of the regression is also simulated, showing that the method is robust to noise in the measurements
  •  
2.
  • Widman, Erik, 1981-, et al. (författare)
  • Speckle tracking strain estimation of a carotid artery plaque phantom - Validation via sonomicrometry
  • 2013
  • Ingår i: 2013 IEEE International Ultrasonics Symposium (IUS). - : IEEE conference proceedings. - 9781467356848 ; , s. 1757-1760
  • Konferensbidrag (refereegranskat)abstract
    • Current clinical ultrasound-based methods for plaque characterization are limited to visual assessment of plaque echogenicity creating demand for quantitative diagnostic tools. Our objective was to validate radial and longitudinal speckle tracking (ST) strain in phantom plaques via sonomicrometry (sono), and to compare the peak plaque and arterial wall strain. Four carotid artery gel-phantoms with a soft wall inclusion, mimicking a vulnerable plaque, were constructed. The phantoms were connected to a programmable pump simulating a carotid flow. Cineloops were acquired using a GE Vivid E9 where radial and longitudinal strain were calculated using a normalized cross-correlation ST algorithm. The region of interest was adjusted according to the plaque size. Sonomicrometry was used as a reference measurement. The correlation between estimated mean peak strain and the reference peak strain was r = 0.96 (p < 0.001) radially and r = 0.75 (p ≤ 0.005) longitudinally. The soft plaque exhibited 35.1% (SD 16.9%) greater radial (p < 0.001) and 88.6% (SD 72.0%) greater longitudinal (p < 0.001) peak strain than the arterial wall when measured with speckle tracking. It was possible to estimate plaque strain by ST and to distinguish a soft plaque from the vessel wall via strain measurements.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
konferensbidrag (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Caidahl, Kenneth (1)
Linder, Tomas (1)
Dhooge, Jan (1)
Larsson, Matilda (1)
Carlson, Johan E. (1)
Heyde, Brecht (1)
visa fler...
Svanström, Erika (1)
Widman, Erik, 1981- (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (1)
Luleå tekniska universitet (1)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Teknik (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy