1.
  • Jensen, Eva, et al. (författare)
  • Changes in hemostasis during pediatric heart surgery: impact of a biocompatible heparin-coated perfusion system.
  • 2004
  • Ingår i: The Annals of thoracic surgery. - : Elsevier BV. - 0003-4975. ; 77:3, s. 962-7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: This study describes the response in hemostasis during open-heart surgery with cardiopulmonary bypass (CPB) in children (<== 10 kg) and tests the hypothesis that the use of a biocompatible perfusion system, in comparison with a conventional system, causes less hemostatic activation. METHODS: Prospective, randomized, controlled clinical study. Forty consecutive children <== 10 kg were included and divided into two groups: group bioc. (n = 19) treated with a fully heparin-coated system, centrifugal pump, and a closed circuit, and group conv. (n = 21) treated with an uncoated system, roller pump, and a hard shell venous reservoir. Concentrations of plasma thrombin-antithrombin (TAT), D-dimer, tissue plasminogen activator antigen (t-PA ag), and the complex consisting of tissue plasminogen activator and its inhibitor plasminogen activator inhibitor-1 (t-PA-PAI-1) were measured. RESULTS: The biochemical variables measured increased significantly in both groups during the study period. There was less activation of fibrinolysis during cardiopulmonary bypass (t-PA ag: p = 0.009) in patients treated with the biocompatible perfusion system than in patients treated with the conventional system. A trend in favor of the biocompatible system based on the D-dimer and TAT data (p = 0.07 for both measurements) was observed but no significant intergroup differences regarding these variables or t-PA-PAI-1 were found. CONCLUSIONS: Open-heart surgery with cardiopulmonary bypass in children (<== 10 kg) causes transient activation of the coagulation and fibrinolytic systems. This study demonstrates that the use of a biocompatible perfusion system results in a lower extent of activation of fibrinolysis during CPB than the use of a conventional system.
  •  
2.
  • Jensen, Eva, et al. (författare)
  • Influence of two different perfusion systems on inflammatory response in pediatric heart surgery.
  • 2003
  • Ingår i: The Annals of thoracic surgery. - 0003-4975. ; 75:3, s. 919-25
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: This study tests the hypothesis that a cardiopulmonary bypass system that combines complete heparin-coating, a centrifugal pump, and a closed circuit in comparison with a conventional system (uncoated system, roller pump, and hard shell venous reservoir) attenuates the inflammatory response in pediatric heart surgery. METHODS: In a prospective randomized controlled clinical study 40 consecutive children weighing 10 kg or less were included and divided into two groups. Concentrations of complement proteins (C3a, sC5b-9, C4d, and Bb), granulocyte degranulation products (polymorphonuclear [PMN] elastase), and proinflammatory cytokines (tumor necrosis factor [TNF]-alpha, interleukin [IL]-6, and IL-8) were measured. RESULTS: C3a and sC5b-9 concentrations were lower (C3a, p < 0.001; sC5b-9, p = 0.01) in the combined (heparin-coated/centrifugal pump/closed reservoir) group, the peak values being 58% and 37% of conventional group values. The Bb- and C4d-fragment values indicated activation of the complement system through the alternative pathway in both groups. PMN elastase concentrations were lower (p = 0.02) in the combined group, the peak values being 43% of conventional group values. There were no significant intergroup differences regarding TNF-alpha, IL-6, or IL-8 concentrations. CONCLUSIONS: The use of a fully heparin-coated system, a centrifugal pump, and a closed circuit during CPB in children (10 kg or less) leads to a lower degree of complement activation and PMN elastase release compared with a conventional system.
  •  
3.
  •  
4.
  • Löfgren, N., et al. (författare)
  • Remote sessions and frequency analysis for improved insight into cerebral function during pediatric and neonatal intensive care.
  • 2003
  • Ingår i: IEEE transactions on information technology in biomedicine. - 1089-7771 .- 1558-0032. ; 7:4, s. 283-90
  • Tidskriftsartikel (refereegranskat)abstract
    • A project involving recording and analysing EEG together with cardiovascular signals and temperature has been initiated. The aim of this project is to establish difficulties and possibilities involved with implementing a system for remote sessions and analysing EEG in correlation with other physiological signals. One objective is to find indicators of cerebral function during postasphyxia neonatal intensive care and pediatric cardiopulmonary bypass surgery with hypothermia. Remote sessions for joint interpretation have been carried out between pediatricians and clinical neurophysiologists, and EEG has been analyzed using frequency analyzing tools. One result is the discovery of reversible spectral changes coinciding with blood pressure falls, which may indicate loss of autoregulation function. This finding is one outcome from initial use of a system, developed during the project to facilitate communication about, and analysis of the recorded signals. Thus, already from a limited number of remote sessions and the use of basic signal processing techniques, important results have been achieved and better insight has been gained of how cerebral function is affected by cardiopulmonary bypass surgery. In this paper, we present our experiences from introducing a system for remote consultations, and evaluate the use for such a system in the current applications.
  •  