SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Andrianov S.) "

Sökning: WFRF:(Andrianov S.)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lestinsky, M., et al. (författare)
  • Physics book: CRYRING@ESR
  • 2016
  • Ingår i: European Physical Journal: Special Topics. - : Springer Science and Business Media LLC. - 1951-6401 .- 1951-6355. ; 225:5, s. 797-882
  • Forskningsöversikt (refereegranskat)abstract
    • The exploration of the unique properties of stored and cooled beams of highly-charged ions as provided by heavy-ion storage rings has opened novel and fascinating research opportunities in the realm of atomic and nuclear physics research. Since the late 1980s, pioneering work has been performed at the CRYRING at Stockholm (Abrahamsson et al. 1993) and at the Test Storage Ring (TSR) at Heidelberg (Baumann et al. 1988). For the heaviest ions in the highest charge-states, a real quantum jump was achieved in the early 1990s by the commissioning of the Experimental Storage Ring (ESR) at GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt (Franzke 1987) where challenging experiments on the electron dynamics in the strong field regime as well as nuclear physics studies on exotic nuclei and at the borderline to atomic physics were performed. Meanwhile also at Lanzhou a heavy-ion storage ring has been taken in operation, exploiting the unique research opportunities in particular for medium-heavy ions and exotic nuclei (Xia et al. 2002).
  •  
2.
  • Eversmann, D., et al. (författare)
  • New Method for a Continuous Determination of the Spin Tune in Storage Rings and Implications for Precision Experiments
  • 2015
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 115:9
  • Tidskriftsartikel (refereegranskat)abstract
    • A new method to determine the spin tune is described and tested. In an ideal planar magnetic ring, the spin tune-defined as the number of spin precessions per turn-is given by nu(s) = gamma G (gamma is the Lorentz factor, G the gyromagnetic anomaly). At 970 MeV/c, the deuteron spins coherently process at a frequency of approximate to 120 kHz in the Cooler Synchrotron COSY. The spin tune is deduced from the up-down asymmetry of deuteron-carbon scattering. In a time interval of 2.6 s, the spin tune was determined with a precision of the order 10(-8), and to 1 x 10(-10) for a continuous 100 s accelerator cycle. This renders the presented method a new precision tool for accelerator physics; controlling the spin motion of particles to high precision is mandatory, in particular, for the measurement of electric dipole moments of charged particles in a storage ring.
  •  
3.
  • Guidoboni, G., et al. (författare)
  • How to Reach a Thousand-Second in-Plane Polarization Lifetime with 0.97-GeV/c Deuterons in a Storage Ring
  • 2016
  • Ingår i: Physical Review Letters. - : American Physical Society. - 0031-9007 .- 1079-7114. ; 117:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We observe a deuteron beam polarization lifetime near 1000 s in the horizontal plane of a magnetic storage ring (COSY). This long spin coherence time is maintained through a combination of beam bunching, electron cooling, sextupole field corrections, and the suppression of collective effects through beam current limits. This record lifetime is required for a storage ring search for an intrinsic electric dipole moment on the deuteron at a statistical sensitivity level approaching 10(-29) e cm.
  •  
4.
  •  
5.
  •  
6.
  • Lu, W, et al. (författare)
  • Reliability assessment and degradation analysis of 1.3 µm GaInNAs lasers
  • 2009
  • Ingår i: Journal of Applied Physics. - : AIP Publishing. - 0021-8979 .- 1089-7550. ; 106:9, s. 093110-
  • Tidskriftsartikel (refereegranskat)abstract
    • The degradation of 1.3 mu m GaInNAs lasers was investigated using accelerated aging tests. This was followed by comprehensive characterization, including standard light-current-voltage (L-I-V) characterization, capacitance measurements, photoluminescence microscopy (PLM), on-axis amplified spontaneous emission (ASE) spectra measurements, and photocurrent (PC) and electroluminescence (EL) spectroscopies. The slope efficiency of the device dropped by 50% with a 300% increase in the threshold current after the accelerated aging test. The ideality factors of the aged devices are higher than those of the unaged devices. PLM images showed no evidence of catastrophic optical mirror damage. The measured capacitances of the aged devices are all similar to those of the unaged devices, indicating that there was no significant dopant diffusion in the junction region. Fourier transforms of the ASE spectra showed that no intracavity defects were present in the aged lasers, suggesting that intracavity defects are not responsible for the rapid degradation of the aged devices. Although the PC measurements showed defects at 0.88-0.95 eV and at similar to 0.76 eV, these defect signatures did not increase with aging. On the other hand, EL measurements revealed that radiative deep level defects were generated during the aging tests. which may be related to the degradation of the devices. Based on the above measurement results, we identify, the generation Of radiative deep level defects as the main causes of degradation of these devices.
  •  
7.
  • Boffano, P., et al. (författare)
  • The epidemiology and management of ameloblastomas: A European multicenter study
  • 2021
  • Ingår i: Journal of Cranio-Maxillofacial Surgery. - : Elsevier BV. - 1010-5182. ; 49:12, s. 1107-1112
  • Tidskriftsartikel (refereegranskat)abstract
    • The present study aimed at assessing the epidemiology including demographic variables, diagnostic features, and management of ameloblastomas at several European departments of maxillofacial and oral surgery. The following data were recorded for each patient: gender, age, voluptuary habits, comorbidities, site, size, radiographic features, type, histopathological features, kind of treatment, length of hospital stay, complications, recurrence, management and complications of the recurrence. A total of 244 patients, 134 males and 110 females with ameloblastomas were included in the study. Mean age was 47.4 years. In all, 81% of lesions were found in the mandible, whereas 19% were found in the maxilla. Mean size of included ameloblastomas was 38.9 mm. The most frequently performed treatment option was enucleation plus curettage/peripheral ostectomy in 94 ameloblastomas, followed by segmental resection (60 patients), simple enucleation (46 patients), and marginal resection (40 pa-tients). A recurrence (with a mean follow up of 5 years) was observed in 47 cases out of 244 ameloblastomas (19.3%). Segmental resection was associated with a low risk of recurrence (p = 0003), whereas enucleation plus curettage/peripheral ostectomy was associated with a high risk of recurrence (p = 0002). A multilocular radiographic appearance was associated with a high risk of recurrence (p < .05), as well as the benign solid/multicystic histologic type (p < .05). Within the limitations of the study it seems that the management of ameloblastomas will probably remain controversial even in the future. Balancing low surgical morbidity with a low recurrence rate is a difficult aim to reach. (c) 2021 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
  •  
8.
  • Lu, W, et al. (författare)
  • Independent determination of In and N concentrations in GaInNAs alloys
  • 2009
  • Ingår i: Semiconductor Science and Technology. - : IOP Publishing. - 1361-6641 .- 0268-1242. ; 24:10, s. 105016-
  • Tidskriftsartikel (refereegranskat)abstract
    • High-resolution x-ray diffraction (HRXRD) and photoreflectance ( PR) spectroscopy were used to independently determine the In and N concentrations in GaInNAs alloys grown by solid-source molecular beam epitaxy (SSMBE). The lattice constant and bandgap energy can be expressed as two independent equations in terms of the In and N concentrations, respectively. The HRXRD measurement provided the lattice constant and the PR measurement extracted the bandgap energy. By simultaneously solving these two equations, we have determined the In and N concentrations with the error as small as 0.001.
  •  
9.
  •  
10.
  • Shubina, T. V., et al. (författare)
  • III-nitride tunable cup-cavities supporting quasi whispering gallery modes from ultraviolet to infrared
  • 2015
  • Ingår i: Scientific Reports. - : NATURE PUBLISHING GROUP. - 2045-2322. ; 5:17970
  • Tidskriftsartikel (refereegranskat)abstract
    • Rapidly developing nanophotonics needs microresonators for different spectral ranges, formed by chip-compatible technologies. In addition, the tunable ones are much in demand. Here, we present site-controlled III-nitride monocrystal cup-cavities grown by molecular beam epitaxy. The cup-cavities can operate from ultraviolet to near-infrared, supporting quasi whispering gallery modes up to room temperature. Besides, their energies are identical in large ripened crystals. In these cavities, the refractive index variation near an absorption edge causes the remarkable effect of mode switching, which is accompanied by the spatial redistribution of electric field intensity with concentration of light into a subwavelength volume. Our results shed light on the mode behavior in semiconductor cavities and open the way for single-growth-run manufacturing the devices comprising an active region and a cavity with tunable mode frequencies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy