SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Armijo G. K.) "

Sökning: WFRF:(Armijo G. K.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adcox, K, et al. (författare)
  • PHENIX detector overview
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Cooper, M. D., et al. (författare)
  • Construction and performance of MEGA's low-mass, high-rate cylindrical MWPCs
  • 1998
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 417:1, s. 24-49
  • Tidskriftsartikel (refereegranskat)abstract
    • A design for extremely low mass, high-resolution multiwire proportional chambers (MWPC) was achieved by the MEGA collaboration in its experiment to search for the lepton family number violating decay μ → eγ. To extend the present branching ratio limit by over an order of magnitude, these MWPCs were operated in high particle fluxes. They showed minimal effects of aging, and evidenced spatial and energy resolutions for the orbiting positrons from muon decay which were consistent with our design parameters. The unique features of these chambers, their assembly into the MEGA positron spectrometer, and their performance during the experiment are described in this paper.
  •  
3.
  • Armijo, V., et al. (författare)
  • A fast MWPC with cathode strips and utilizing CF4-isobutane
  • 1991
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 303:2, s. 298-308
  • Tidskriftsartikel (refereegranskat)abstract
    • A planar wire chamber has been developed at LAMPF as a prototype for wire chambers of cylindrical configuration for electron detection in the MEGA experiment. Results form tests with the planar chamber have been used to set the geometrical parameters and predict the performance characteristics of the cylindrical chambers. The behavior of the planar chamber with CF4-isobutane gas demonstrates that 15 μm wire of 1 mm pitch is practical, that lifetimes greater than 0.045 C/cm are achievable and that gate widths of 25 ns are possible. © 1991.
  •  
4.
  • Mischke, R. E., et al. (författare)
  • Low mass, high rate cylindrical MWPCs for the MEGA experiment
  • 1990
  • Konferensbidrag (refereegranskat)abstract
    • The construction of MWPCs for the MEGA experiment at LAMPF are described. The chambers are cylindrical, low mass (3 {times} 10{sup {minus}4} radiation lengths), and are designed to operate at high rates (3 {times} 10{sup 4} /mm{sup 2}/s). Several novel construction techniques have been developed and custom electronics have been designed to help achieve the required performance, which corresponds to that needed at high luminosity colliders. 
  •  
5.
  • Stanislaus, S., et al. (författare)
  • Results from beam tests of MEGA's low-mass, high-rate cylindrical MWPCs
  • 1992
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 323:1-2, s. 198-202
  • Tidskriftsartikel (refereegranskat)abstract
    • One of the leading experimental projects at LAMPF has been the MEGA experiment. This is an experiment to search for the rare decay μ → eγ with a sensitivity of 10-13. A prime component of this project has been the design and construction of high-rate, low-mass MWPCs for the tracking of positrons from muon decay. With rate capabilities of 2 × 104 e+/mm2/s and a thickness of 3 × 10-4 radiation lengths, these chambers are state-of-the-art cylindrical MWPCs. Cylindrical chambers of this size (0.9 m2) and thinness have never been previously constructed. The MEGA project at LAMPF has recently succeeded in building chambers with these necessary performance characteristics as demonstrated by data taken from muon decays, cosmic rays, and sources. © 1992.
  •  
6.
  • Miltiadous, O., et al. (författare)
  • Early intestinal microbial features are associated with CD4 T-cell recovery after allogeneic hematopoietic transplant
  • 2022
  • Ingår i: Blood. - : American Society of Hematology. - 0006-4971 .- 1528-0020. ; 139:18, s. 2758-2769
  • Tidskriftsartikel (refereegranskat)abstract
    • Low intestinal microbial diversity is associated with poor outcomes after allogeneic hematopoietic cell transplantation (HCT). Using 16S rRNA sequencing of 2067 stool samples and flow cytometry data from 2370 peripheral blood samples drawn from 894 patients who underwent allogeneic HCT, we have linked features of the early post-HCT microbiome with subsequent immune cell recovery. We examined lymphocyte recovery and microbiota features in recipients of both unmodified and CD34-selected allografts. We observed that fecal microbial diversity was an independent predictor of CD4 T-cell count 3 months after HCT in recipients of a CD34-selected allograft, who are dependent on de novo lymphopoiesis for their immune recovery. In multivariate models using clinical factors and microbiota features, we consistently observed that increased fecal relative abundance of genus Staphylococcus during the early posttransplant period was associated with worse CD4 T-cell recovery. Our observations suggest that the intestinal bacteria, or the factors they produce, can affect early lymphopoiesis and the homeostasis of allograft-derived T cells after transplantation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy