SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Asklund H) "

Sökning: WFRF:(Asklund H)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Asklund, H, et al. (författare)
  • Photoemission study of GaAs (100) grown at low temperature
  • 2002
  • Ingår i: Physical Review B (Condensed Matter and Materials Physics). - 1098-0121. ; 65:11
  • Tidskriftsartikel (refereegranskat)abstract
    • GaAs(100) layers grown by low-temperature (LT) molecular beam epitaxy were studied by means of valence-band and core-level photoelectron spectroscopy. Small differences were found between valence-band spectra from the LT layers and corresponding layers grown at high temperature. In the Ga 3d spectra a new component was found in the LT-GaAs. The relative intensity of this component was found to be practically constant with varying probing depth. It is proposed that this component represents sites coordinated to the five-atom As clusters formed at As-Ga antisites. This interpretation implies a higher density of antisite defects in the near-surface region than typically found in the bulk.
  •  
2.
  • Jonsson, Joakim H., et al. (författare)
  • Accuracy of inverse treatment planning on substitute CT images derived from MR data for brain lesions
  • 2015
  • Ingår i: Radiation Oncology. - : Springer Science and Business Media LLC. - 1748-717X. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In this pilot study we evaluated the performance of a substitute CT (s-CT) image derived from MR data of the brain, as a basis for optimization of intensity modulated rotational therapy, final dose calculation and derivation of reference images for patient positioning. Methods: S-CT images were created using a Gaussian mixture regression model on five patients previously treated with radiotherapy. Optimizations were compared using D-max, D-min, D-median and D-mean measures for the target volume and relevant risk structures. Final dose calculations were compared using gamma index with 1%/1 mm and 3%/3 mm acceptance criteria. 3D geometric evaluation was conducted using the DICE similarity coefficient for bony structures. 2D geometric comparison of digitally reconstructed radiographs (DRRs) was performed by manual delineation of relevant structures on the s-CT DRR that were transferred to the CT DRR and compared by visual inspection. Results: Differences for the target volumes in optimization comparisons were small in general, e.g. a mean difference in both D-min and D-max within similar to 0.3%. For the final dose calculation gamma evaluations, 100% of the voxels passed the 1%/1 mm criterion within the PTV. Within the entire external volume between 99.4% and 100% of the voxels passed the 3%/3 mm criterion. In the 3D geometric comparison, the DICE index varied between approximately 0.8-0.9, depending on the position in the skull. In the 2D DRR comparisons, no appreciable visual differences were found. Conclusions: Even though the present work involves a limited number of patients, the results provide a strong indication that optimization and dose calculation based on s-CT data is accurate regarding both geometry and dosimetry.
  •  
3.
  •  
4.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy