  • Hintikka, E. -L., et al. (författare)
  • Mycotoxins in the ventilation systems of four schools in Finland
  • 2009
  • Ingår i: World Mycotoxin Journal. - 1875-0796. ; 2:4, s. 369-379
  • Tidskriftsartikel (refereegranskat)abstract
    • Some fungal species have been listed as a problem causing fungi in indoor air and most of this group are known to produce mycotoxins. So far, mycotoxins have been found in building materials and in samples representing settled indoor air dust, as well in air samples from industrial or agricultural environments. The present paper presents the results of a mycological study and mycotoxin analyses of dust collected from mechanical ventilation systems in four school buildings in southern Finland. The aim of this work was to answer the question 'Are there mycotoxins in ventilation systems and if so, from where do they originate?' A total of 40 mycotoxins representing indoor and outdoor sources alike were screened in this study, while cultivable fungi were screened using four different cultivation media. Mycotoxins were present in all ventilation systems studied, both in the supply and the exhaust systems examined. The mycotoxins found included satratoxins, verrucarol, trichodermol, enniatins, beauvericin, penicillic acid, sterigmatocystin, chaetoglobosin A, and aflatoxins B-1. The mycotoxins were present in minute quantities (pg-ng/g or pg-ng/cm(2)). The fungal genera associated with respective mycotoxins were found in most of the same sources. Since much the same mycotoxins could be established in both exhaust and supply air systems, it would appear that the mycotoxins found in the schools studied do not for the most part originate from sources within the building but are either normal artefacts of incoming supply air or concentrate or are perhaps produced within the ventilation systems due to infrequent changing of filters and maintenance/cleaning of ventilation ducts and associated parts of the systems.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy