SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Aurell Ylva 1955) "

Sökning: WFRF:(Aurell Ylva 1955)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andreasson, Ingrid, et al. (författare)
  • Functional outcome after corrective osteotomy for malunion of the distal radius: a randomised, controlled, double-blind trial
  • 2020
  • Ingår i: International Orthopaedics. - : Springer Science and Business Media LLC. - 0341-2695 .- 1432-5195. ; 44:7, s. 1353-1365
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose The purpose of this randomised, controlled, double-blind trial was to evaluate functional outcome during the first year after corrective osteotomy for malunited distal radius fractures, with or without filling the osteotomy void. Method Patients were randomised to receive a HydroSet bone substitute or no graft. Cortical contact was maintained and stabilisation of the osteotomy was carried out with a DiPhos R- or RM Plate. To evaluate subjective functional outcome, the Patient-Rated Wrist Evaluation (PRWE), the Quick Disabilities of the Arm, Shoulder and Hand Questionnaire (Q-DASH), the Canadian Occupational Performance Measure (COPM) and the RAND-36 were used. Moreover, range of motion and grip strength were measured by blinded evaluators. Evaluations were made pre-operatively and three, six and 12 months post-operatively. Results There were no significant differences between the groups at any time point post-operatively with respect to any of the PROMs that were used or range of motion or grip strength (p> 0.05). In both groups, there was a significant improvement at the 12-month follow-up compared with pre-operatively for the PRWE, the Q-DASH and the COPM satisfaction scores. The RAND-36 revealed no significant differences except for two domains, in which there was an improvement in the treatment group (p< 0.05). For grip strength and for range of motion in all movement directions, except dorsal extension, there was a significant improvement in both groups (p< 0.05). Conclusion There is no significant difference in functional outcome during the first year after corrective open-wedge distal radius osteotomy, where cortical contact is maintained, regardless of whether or not bone substitute to fill the void is used.
  •  
2.
  • Flinck, Marianne, et al. (författare)
  • Leg length discrepancy after skeletal maturity in patients treated with elastic intramedullary nails after femoral shaft fractures in childhood
  • 2022
  • Ingår i: Journal of Childrens Orthopaedics. - : SAGE Publications. - 1863-2521 .- 1863-2548. ; 16:4, s. 276-284
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose was to study radiographic and perceived leg length discrepancy after skeletal maturity in patients treated for femoral shaft fractures with elastic stable intramedullary nails in childhood. Methods: Thirty-five adults underwent standing radiographs and answered a questionnaire regarding perception of leg length discrepancy. Demographic data, fracture characteristics, angulation, stability of fixation, and callus formation, at time of fracture, were assessed. Results: Mean age at fracture was 10.2 (4.9-16.7) years, and mean follow-up time was 11.1 (3.8-16.8) years. In 8 of 35 participants, the fractured limb was 11-15 mm longer than the non-fractured, and in 16, 1-10 mm longer. In eight participants, the fractured limb was 1-10 mm shorter than the non-fractured, and in three participants, 12-23 mm shorter. The younger the child, the greater the lengthening (R-s = -0.49, p = 0.003). The greater the femoral angulation at time of fracture, the greater the shortening (R-s = 0.42, p = 0.013). There was no significant correlation between stability of fixation or callus formation 1 month postoperatively and radiographic leg length discrepancy after skeletal maturity. Fourteen (40%) had perception of leg length discrepancy at follow-up, of whom eight had a radiographic leg length discrepancy of 10-24 mm. Conclusion: Treatment with elastic stable intramedullary nail of femoral shaft fracture in childhood may result in radiographic leg length discrepancy. Younger children were more prone to lengthening and should possibly be assessed before skeletal maturity. The degree of fracture stability or callus formation at the time of fracture did not significantly affect leg length discrepancy. Perception of leg length discrepancy was not necessarily associated with a radiographic leg length discrepancy (>= 10 mm).
  •  
3.
  • Johansson, Arne G., et al. (författare)
  • A four-year clinical and sonographic longitudinal follow-up of clubfeet treated according to Ponseti with normal references
  • 2023
  • Ingår i: Journal of Childrens Orthopaedics. - 1863-2521. ; 17:3, s. 212-223
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose:To follow children with a clubfoot by ultrasonography during the entire treatment period up to 4 years and compare with controls. Method:Thirty clubfeet in 20 children treated using the Ponseti method and 29 controls were followed by repeated ultrasonography investigations from neonates to the age of 4 years. The previously established coronal medial and lateral, sagittal dorsal and posterior projections were used. Changes over time, correlations to the Dimeglio score, and the course of treatment were studied. Results:The medial malleolus-navicular distance was shorter, while the talar tangent-navicular distance and the talo-navicular angle were larger in clubfeet than in controls even after the initial correction. The healthy feet in unilateral cases did not differ significantly from the controls. The range of motion in the talo-navicular joint was approximately 20 degrees less in clubfeet than in controls during the first four years of life. The medial malleolus-navicular distance (r = -0.58) and the talo-navicular angle (r = 0.66) at the first ultrasonography showed the highest correlation to the number of casts needed to correct the deformities. Conclusion:Ultrasonography can be used to evaluate the initial degree of deformities in clubfeet and to follow the progress of the treatment and growth. Ultrasonography showed a clear difference between clubfeet and controls during the first four years of life. Although it was not possible to define specific limit values as benchmarks in the treatment, dynamic ultrasonography can provide valuable support in the decision-making process when complementary treatment may be needed.
  •  
4.
  • Lorentsson, Robert, 1969, et al. (författare)
  • Investigation of the Impact of Defective Ultrasound Transducers on Clinical Image Quality in Grayscale 2-D Still Images.
  • 2023
  • Ingår i: Ultrasound in medicine & biology. - 0301-5629 .- 1879-291X. ; 49:9, s. 2126-2133
  • Tidskriftsartikel (refereegranskat)abstract
    • There are several studies that show high defect rates of transducers in clinical use. The purpose of the present study was to investigate whether image quality and the risk for misdiagnosis is affected by using defective transducers.Four defective transducers with varying degrees of defect severity, still in clinical use, were selected. Forty artifact-affected clinical images from each transducer were compared with images acquired from fully functional transducers, of the same model, in an observer study where four experienced radiologists rated each of the 320 images. The rating tasks included if the artifacts were detectable, if the possible artifacts might affect the diagnosis, how well structural details were reproduced and, finally, an assessment of overall image quality.The artifacts in the images were detectable for three of the four transducers (p < 0.05), and in 121 of 640 assessments of the images from the defective transducers the observers were confident that the artifacts could affect the diagnosis. All four faulty transducers were assessed to have decreased ability to resolve structural details (p < 0.05), and three of the four transducers were assessed to have worse overall image quality (p < 0.05).The present study shows that image quality and the risk of misdiagnosis can be affected by using defective transducers. This highlights the importance of frequent quality control of the transducers to avoid decreased image quality and even misdiagnosis.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy