SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Båth M.) "

Sökning: WFRF:(Båth M.)

  • Resultat 1-25 av 25
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Nango, E., et al. (författare)
  • A three-dimensional movie of structural changes in bacteriorhodopsin
  • 2016
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 354:6319, s. 1552-1557
  • Tidskriftsartikel (refereegranskat)abstract
    • Bacteriorhodopsin (bR) is a light-driven proton pump and a model membrane transport protein. We used time-resolved serial femtosecond crystallography at an x-ray free electron laser to visualize conformational changes in bR from nanoseconds to milliseconds following photoactivation. An initially twisted retinal chromophore displaces a conserved tryptophan residue of transmembrane helix F on the cytoplasmic side of the protein while dislodging a key water molecule on the extracellular side. The resulting cascade of structural changes throughout the protein shows how motions are choreographed as bR transports protons uphill against a transmembrane concentration gradient.
  •  
2.
  • Edlund, Petra, et al. (författare)
  • The room temperature crystal structure of a bacterial phytochrome determined by serial femtosecond crystallography
  • 2016
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • Phytochromes are a family of photoreceptors that control light responses of plants, fungi and bacteria. A sequence of structural changes, which is not yet fully understood, leads to activation of an output domain. Time-resolved serial femtosecond crystallography (SFX) can potentially shine light on these conformational changes. Here we report the room temperature crystal structure of the chromophore-binding domains of the Deinococcus radiodurans phytochrome at 2.1 angstrom resolution. The structure was obtained by serial femtosecond X-ray crystallography from microcrystals at an X-ray free electron laser. We find overall good agreement compared to a crystal structure at 1.35 angstrom resolution derived from conventional crystallography at cryogenic temperatures, which we also report here. The thioether linkage between chromophore and protein is subject to positional ambiguity at the synchrotron, but is fully resolved with SFX. The study paves the way for time-resolved structural investigations of the phytochrome photocycle with time-resolved SFX.
  •  
3.
  • Gruhl, T., et al. (författare)
  • Ultrafast structural changes direct the first molecular events of vision
  • 2023
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 615, s. 939-944
  • Tidskriftsartikel (refereegranskat)abstract
    • Vision is initiated by the rhodopsin family of light-sensitive G protein-coupled receptors (GPCRs)(1). A photon is absorbed by the 11-cis retinal chromophore of rhodopsin, which isomerizes within 200 femtoseconds to the all-trans conformation(2), thereby initiating the cellular signal transduction processes that ultimately lead to vision. However, the intramolecular mechanism by which the photoactivated retinal induces the activation events inside rhodopsin remains experimentally unclear. Here we use ultrafast time-resolved crystallography at room temperature(3) to determine how an isomerized twisted all-trans retinal stores the photon energy that is required to initiate the protein conformational changes associated with the formation of the G protein-binding signalling state. The distorted retinal at a 1-ps time delay after photoactivation has pulled away from half of its numerous interactions with its binding pocket, and the excess of the photon energy is released through an anisotropic protein breathing motion in the direction of the extracellular space. Notably, the very early structural motions in the protein side chains of rhodopsin appear in regions that are involved in later stages of the conserved class A GPCR activation mechanism. Our study sheds light on the earliest stages of vision in vertebrates and points to fundamental aspects of the molecular mechanisms of agonist-mediated GPCR activation.
  •  
4.
  • Nocum, D. J., et al. (författare)
  • Comparison of image quality assessments between interventional radiographers and interventional radiologists using digital subtraction angiography
  • 2023
  • Ingår i: Journal of Medical Imaging. - 2329-4302 .- 2329-4310. ; 10:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The aim of our study was to compare the image quality assessments of vascular anatomy between interventional radiographers and interventional radiologists using digital subtraction angiography (DSA) runs acquired during an interventional radiology procedure. Approach: Visual grading characteristics (VGC) analysis was used to assess image quality by comparing two groups of images, where one group consisted of procedures in which radiation dose was optimized (group A, n = 10) and one group where dose optimization was not performed (group B, n = 10). The radiation dose parameters were optimized based on theoretical and empirical evidence to achieve radiation dose reductions during uterine artery embolization procedures. The two observer groups comprised of interventional radiologists (n = 4) and interventional radiographers (n = 4). Each observer rated the image quality of 20 DSA runs using a five-point rating scale. Results: The VGC analysis produced an area under the VGC curve (AUC(VGC)) of 0.55 for interventional radiographers (P = 0.61) and AUCVGC of 0.52 for interventional radiologists (P = 0.83). The optimization of radiation dose parameters demonstrated a reduction in kermaarea product by 35% (P = 0.026, d = 0.5) and reference air kerma (Ka, r) by 43% (P = 0.042, d = 0.5) between group A and group B. Conclusions: VGC analysis indicated that the image quality assessments of interventional radiographers were comparable with interventional radiologists, where a reduction in radiation dose revealed no effect on both observer groups regarding their image quality assessment of vascular anatomy. (C) 2023 Society of Photo-Optical Instrumentation Engineers (SPIE)
  •  
5.
  • Nogly, P., et al. (författare)
  • Lipidic cubic phase injector is a viable crystal delivery system for time-resolved serial crystallography
  • 2016
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 7
  • Tidskriftsartikel (refereegranskat)abstract
    • Serial femtosecond crystallography (SFX) using X-ray free-electron laser sources is an emerging method with considerable potential for time-resolved pump-probe experiments. Here we present a lipidic cubic phase SFX structure of the light-driven proton pump bacteriorhodopsin (bR) to 2.3 angstrom resolution and a method to investigate protein dynamics with modest sample requirement. Time-resolved SFX (TR-SFX) with a pump-probe delay of 1ms yields difference Fourier maps compatible with the dark to M state transition of bR. Importantly, the method is very sample efficient and reduces sample consumption to about 1mg per collected time point. Accumulation of M intermediate within the crystal lattice is confirmed by time-resolved visible absorption spectroscopy. This study provides an important step towards characterizing the complete photocycle dynamics of retinal proteins and demonstrates the feasibility of a sample efficient viscous medium jet for TR-SFX.
  •  
6.
  • Lanhede, B, et al. (författare)
  • The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria.
  • 2002
  • Ingår i: The British journal of radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 75:889, s. 38-49
  • Tidskriftsartikel (refereegranskat)abstract
    • The Commission of the European Communities (CEC) research project "Predictivity and optimisation in medical radiation protection" addressed fundamental operational limitations in existing radiation protection mechanisms. The first part of the project aimed at investigating (1) whether the CEC image quality criteria could be used for optimization of a radiographic process and (2) whether significant differences in image quality based on these criteria could be detected in a controlled project with well known physical and technical parameters. In the present study, chest radiographs on film were produced using healthy volunteers. Four physical/technical parameters were varied in a carefully controlled manner: tube voltage (102 kVp and 141 kVp), nominal speed class (160 and 320), maximum film density (1.3 and 1.8) and method of scatter reduction (grid (R=12) and air gap). The air kerma at the entrance surface was measured for all patients and the risk-related dose H(Golem), based on calculated organ-equivalent dose conversion coefficients and the measured entrance air kerma values, was calculated. Image quality was evaluated by a group of European expert radiologists using a modified version of the CEC quality criteria. For the two density levels, density level 1.8 was significantly better than 1.3 but at the cost of a higher patient radiation exposure. The correlation between the number of fulfilled quality criteria and H(Golem) was generally poor. An air gap technique resulted in lower doses than scatter reduction with a grid but provided comparable image quality. The criteria can be used to highlight optimum radiographic technique in terms of image quality and patient dose, although not unambiguously. A recommendation for good radiographic technique based on a compromise between image quality and risk-related radiation dose to the patient is to use 141 kVp, an air gap, a screen-film system with speed 320 and an optical density of 1.8.
  •  
7.
  • Nocum, D. J., et al. (författare)
  • Predictors of radiation dose for uterine artery embolisation are angiography system-dependent
  • 2022
  • Ingår i: Journal of Radiological Protection. - : IOP Publishing. - 0952-4746 .- 1361-6498. ; 42:1
  • Tidskriftsartikel (refereegranskat)abstract
    • This study sought to achieve radiation dose reductions for patients receiving uterine artery embolisation (UAE) by evaluating radiation dose measurements for the preceding generation (Allura) and upgraded (Azurion) angiography system. Previous UAE regression models in the literature could not be applied to this centre's practice due to being based on different angiography systems and radiation dose predictor variables. The aims of this study were to establish whether radiation dose is reduced with the upgraded angiography system and to develop a regression model to determine predictors of radiation dose specific to the upgraded angiography system. A comparison between Group I (Allura, n = 95) and Group II (Azurion, n = 95) demonstrated a significant reduction in kerma-area product (KAP) and Ka, r (reference air kerma) by 63% (143.2 Gy cm(2) vs 52.9 Gy cm(2); P < 0.001, d = 0.8) and 67% (0.6 Gy vs 0.2 Gy; P < 0.001, d = 0.8), respectively. The multivariable linear regression (MLR) model identified the UAE radiation dose predictors for KAP on the upgraded angiography system as total fluoroscopy dose, Ka, r, and total uterus volume. The predictive accuracy of the MLR model was assessed using a Bland-Altman plot. The mean difference was 0.39 Gy cm(2) and the limits of agreement were +28.49 and -27.71 Gy cm(2), and thus illustrated no proportional bias. The resultant MLR model was considered system-dependent and validated the upgraded angiography system and its advance capabilities to significantly reduce radiation dose. Interventional radiologist and interventional radiographer familiarisation of the system's features and the implementation of the newly established MLR model would further facilitate dose optimisation for all centres performing UAE procedures using the upgraded angiography system.
  •  
8.
  • Nocum, D. J., et al. (författare)
  • UTERINE ARTERY EMBOLISATION: CONTINUOUS QUALITY IMPROVEMENT REDUCES RADIATION DOSE WHILE MAINTAINING IMAGE QUALITY
  • 2021
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 196:3-4, s. 159-166
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to introduce a continuous quality improvement (CQI) program for radiation dose optimisation during uterine artery embolisation (UAE) and assess its impact on dose reduction and image quality. The CQI program investigated the effects of optimising radiation dose parameters on the kerma-area product (KAP) and image quality when comparing a 'CQI intervention' group (n = 50) and 'Control' group (n = 50). Visual grading characteristics (VGC) analysis was used to assess image quality, using the 'Control' group as a reference. A significant reduction in KAP by 17% ( P = 0.041, d = 0.2) and reference air kerma (Ka, r) by 20% (P = 0.027, d = 0.2) was shown between the two groups. The VGC analysis resulted in an area under the VGC curve (AUCVGC) of 0.54, indicating no significant difference in image quality between the two groups (P = 0.670). The implementation of the CQI program and optimisation of radiation dose parameters improved the UAE radiation dose practices at our centre. The dose reduction demonstrated no detrimental effects on image quality.
  •  
9.
  • Nogly, P., et al. (författare)
  • Retinal isomerization in bacteriorhodopsin captured by a femtosecond x-ray laser
  • 2018
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 361:6398
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION Retinal is a light-sensitive protein ligand that is used by all domains of life to process the information and energy content of light. Retinal-binding proteins are integral membrane proteins that drive vital biological processes, including light sensing for spatial orientation and circadian clock adjustment, as well as maintaining electrochemical gradients through ion transport. They also form the basis for optogenetic manipulation of neural cells. How the protein environment guides retinal isomerization on a subpicosecond time scale toward a single high-yield product is a fundamental outstanding question in photobiology. RATIONALE Light-induced isomerization of retinal is among the fastest reactions known in biology. It has been widely studied by spectroscopic techniques to probe the evolution of spectral intermediates over time. Using x-ray free-electron lasers (XFELs), it is now possible to observe ultrafast photochemical reactions and their induced molecular motions within proteins on scales of femtoseconds to milliseconds with near-atomic structural resolution. In this work, we used XFEL radiation to study the structural dynamics of retinal isomerization in the light-driven proton-pump bacteriorhodopsin (bR). The principal mechanism of isomerization in this prototypical retinal-binding protein has direct relevance for all other members of this important family of membrane proteins, and it provides insight into how protein environments catalyze photochemical reactions in general. RESULTS We collected high-resolution x-ray diffraction data from bR microcrystals injected across the femtosecond x-ray pulses of the Linac Coherent Light Source after excitation of the retinal chromophore by an optical laser pulse. X-ray diffraction images were sorted into temporal subgroups with a precision of about 200 fs. A series of 18 overlapping difference Fourier electron density maps reveal structural changes over the first picosecond of retinal photoexcitation. Complementary data for time delays of 10 ps and 8.33 ms allow us to resolve the later stages of the reaction. In combination with refined crystallographic structures at pump-probe delays corresponding to where the spectroscopically characterized I, J, K, and M intermediates form in solution, our time-resolved structural data reveal the trajectory of retinal isomerization and provide atomic details at key points along the reaction. The aspartic acid residues of the retinal counterion and functional water molecules in close proximity to the retinal Schiff base respond collectively to the formation and decay of the excited state. This collective motion sets the stage for retinal isomerization, which proceeds via a twisted retinal configuration. Quantum mechanics/molecular mechanics simulations provide theoretical support for this structural evolution. CONCLUSION Our observations reveal how, concomitant with the formation of the earliest excited state, the retinal-binding pocket opens up in close proximity to the isomerizing bond. We propose that ultrafast charge transfer along retinal is a driving force for collective motions that contribute to the stereoselectivity and efficiency of retinal isomerization within a protein scaffold. Vibrational quake-like motions extending from retinal to the protein may also be a mechanism through which excess energy is released in a nonradiative fashion.
  •  
10.
  • Ullman, Gustav, et al. (författare)
  • On the extent of quantum noise limitation in digital chest radiography
  • 2004
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • The aim for this work was to study to what extent the detection of nodules is quantum noise limited, based on the combined results from a nodule-detection clinical trial and a Monte Carlo computational model of a digital chest imaging system. The Monte Carlo computer program computes measures of physical image quality such as image contrast, C and signalto-noise ratio, SNR for nodules of any size. A computed radiography (CR) imaging system used simulated. The patient anterior-posterior thickness was 25 cm and nodules with diameters between 1-40 mm were included. The image contrast and SNR was calculated for 1600 (40x40) positions in the chest image and averaged over five anatomical regions of interest (lateral pulmonary, retrocardial, hilar, lower- and upper mediastinal regions). Threshold contrasts for each region, Cth, corresponding to Az=0.80 for detecting a 10 mm nodule, were deduced from the clinical trial. A threshold is also used for the quantum noise signal-to-noise ratio, SNRth. The model computes the diameter of a disk-shaped object that is required to comply with the two criteria: SNR≥SNRth and C≥Cth. A system is said to be quantum noise limited when the nodule size required to fulfil both criteria is not limited by the contrast but by the SNR. The required nodule diameter is largest in the hilar region (25 mm) and smallest in the lateral pulmonary region (11 mm). When the threshold SNRth=25 is used, the lower mediastinal region is quantum noise limited already at low speed classes (S>100). The hilar region is never quantum noise limited at realistic speed classes (S<1000). The accuracy of this model will be tested in the future by more sophisticated modelling of anatomical background and noise in the SNR-expression.
  •  
11.
  • Amani, Pegah, 1983, et al. (författare)
  • Food product clustering for customized food logistics
  • 2013
  • Ingår i: 7th International European Forum (Igls-Forum) - (136th EAAE Seminar) on System Dynamics and Innovation in Food Networks , Innsbruck-Igls, Austria.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
  •  
12.
  • Båth, Petra, 1988, et al. (författare)
  • Lipidic cubic phase serial femtosecond crystallography structure of a photosynthetic reaction centre
  • 2022
  • Ingår i: Acta Crystallographica Section D-Structural Biology. - : International Union of Crystallography (IUCr). - 2059-7983. ; 78, s. 698-708
  • Tidskriftsartikel (refereegranskat)abstract
    • Serial crystallography is a rapidly growing method that can yield structural insights from microcrystals that were previously considered to be too small to be useful in conventional X-ray crystallography. Here, conditions for growing microcrystals of the photosynthetic reaction centre of Blastochloris viridis within a lipidic cubic phase (LCP) crystallization matrix that employ a seeding protocol utilizing detergent-grown crystals with a different crystal packing are described. LCP microcrystals diffracted to 2.25 angstrom resolution when exposed to XFEL radiation, which is an improvement of 0.15 angstrom over previous microcrystal forms. Ubiquinone was incorporated into the LCP crystallization media and the resulting electron density within the mobile Q(B) pocket is comparable to that of other cofactors within the structure. As such, LCP microcrystallization conditions will facilitate time-resolved diffraction studies of electron-transfer reactions to the mobile quinone, potentially allowing the observation of structural changes associated with the two electron-transfer reactions leading to complete reduction of the ubiquinone ligand.
  •  
13.
  • Dobbins, James T, et al. (författare)
  • Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.
  • 2017
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 1527-1315 .- 0033-8419. ; 282:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P < .001; 95% confidence interval [CI]: 2.96, 4.15). Case-level sensitivity was higher with tomosynthesis than with conventional chest radiography for all nodules (1.49-fold, P < .001; 95% CI: 1.25, 1.73). Case management decisions showed better overall accuracy with tomosynthesis than with conventional chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P < .001; 95% CI: 1.15, 1.32). There were no differences in any specificity measures. DE imaging did not significantly affect nodule detection when paired with either conventional chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest radiography or tomosynthesis alone. These findings indicate performance likely achievable with a range of reader expertise. (©) RSNA, 2016 Online supplemental material is available for this article.
  •  
14.
  • Hansson, Jonny, et al. (författare)
  • An optimisation strategy in a digital environment applied to neonatal chest imaging.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 278-85
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to find the optimum tube voltage for neonatal chest imaging in computed radiography. The study was designed to take full advantage of the benefits of digital imaging, for example, by comparing the tube voltages at constant effective dose. A phantom study using a living rabbit was first conducted. Images were collected at tube voltages ranging from 40 to 90 kV(p). The reproduction of four structures (central vessels, peripheral vessels, carina and thoracic vertebrae) was rated by 10 radiologists. The reproduction of both central and peripheral vessels was relatively independent of tube voltage. The carina was better reproduced at higher tube voltages whereas the opposite was true for the thoracic vertebrae. Based on the higher importance of the reproduction of the carina it was decided that 90 kV(p) was the optimal tube voltage. To validate the result from the phantom study, a follow-up study was conducted in which images of neonates collected at the tube voltage regularly used at Sahlgrenska University Hospital (70 kV(p)) were compared with images collected at the tube voltage proposed by the phantom study. The follow-up study confirmed the results from the phantom study that the reproduction of the carina was better at 90 than at 70 kV(p). In conclusion, for neonatal chest imaging-given the same effective dose-90 kVp gives better reproduction of important structures than the regularly used 70 kV(p).
  •  
15.
  • Hemdal, Bengt, et al. (författare)
  • Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 383-8
  • Tidskriftsartikel (refereegranskat)abstract
    • There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.
  •  
16.
  • Jadidi, M., et al. (författare)
  • Dependency of image quality on acquisition protocol and image processing in chest tomosynthesis-a visual grading study based on clinical data
  • 2018
  • Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 91:1087
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To compare the quality of images obtained with two different protocols with different acquisition time and the influence from image post processing in a chest digital tomosynthesis (DTS) system. Methods: 20 patients with suspected lung cancer were imaged with a chest X-ray equipment with tomosynthesis option. Two examination protocols with different acquisition times (6.3 and 12 s) were performed on each patient. Both protocols were presented with two different image post-processing (standard DTS processing and more advanced processing optimised for chest radiography). Thus, 4 series from each patient, altogether 80 series, were presented anonymously and in a random order. Five observers rated the quality of the reconstructed section images according to predefined quality criteria in three different classes. Visual grading characteristics (VGC) was used to analyse the data and the area under the VGC curve (AUC(VGC)) was used as figure-of-merit. The 12 s protocol and the standard DTS processing were used as references in the analyses. Results: The protocol with 6.3s acquisition time had a statistically significant advantage over the vendor-recommended protocol with 12s acquisition time for the classes of criteria, Demarcation (AUC(VGC)= 0.56, p = 0.009) and Disturbance (AUC(VGC) = 0.58, p < 0.001). A similar value of AUC(VGC) was found also for the class Structure (definition of bone structures in the spine) (0.56) but it could not be statistically separated from 0.5 (p = 0.21). For the image processing, the VGC analysis showed a small but statistically significant advantage for the standard DTS processing over the more advanced processing for the classes of criteria Demarcation (AUC vGc = 0.45, p = 0.017) and Disturbance (AUC(VGC) = 0.43, p = 0.005). A similar value of AUC(VGC)was found also for the class Structure (0.46), but it could not be statistically separated from 0.5 (p = 0.31). Conclusion: The study indicates that the protocol with 6.3 s acquisition time yields slightly better image quality than the vender-recommended protocol with acquisition time 12 s for several anatomical structures. Furthermore, the standard gradation processing (the vendor- recommended post-processing for DTS), yields to some extent advantage over the gradation processing/multiobjective frequency processing/flexible noise control processing in terms of image quality for all classes of criteria. Advances In knowledge: The study proves that the image quality may be strongly affected by the selection of DTS protocol and that the vendor-recommended protocol may not always be the optimal choice.
  •  
17.
  • Jadidi, M, et al. (författare)
  • Evaluation of a new system for chest tomosynthesis : aspects of image quality of different protocols determined using an anthropomorphic phantom.
  • 2015
  • Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 88:1053, s. 20150057-
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To compare the image quality obtained with the different protocols in a new chest digital tomosynthesis (DTS) system.METHODS: A chest phantom was imaged with chest X-ray equipment with DTS. 10 protocols were used, and for each protocol, nine acquisitions were performed. Four observers visually rated the quality of the reconstructed section images according to pre-defined quality criteria in four different classes. The data were analysed with visual grading characteristics (VGC) analysis, using the vendor-recommended protocol [12-s acquisition time, source-to-image distance (SID) 180 cm] as reference, and the area under the VGC curve (AUCVGC) was determined for each protocol and class of criteria.RESULTS: Protocols with a smaller swing angle resulted in a lower image quality for the classes of criteria "disturbance" and "homogeneity in nodule" but a higher image quality for the class "structure". The class "demarcation" showed little dependency on the swing angle. All protocols but one (6.3 s, SID 130 cm) obtained an AUCVGC significantly <0.5 (indicating lower quality than reference) for at least one class of criteria.CONCLUSION: The study indicates that the DTS protocol with 6.3 s yields image quality similar to that obtained with the vendor-recommended protocol (12 s) but with the clinically important advantage for patients with respiratory impairment of a shorter acquisition time.ADVANCES IN KNOWLEDGE: The study demonstrates that the image quality may be strongly affected by the choice of protocol and that the vendor-recommended protocol may not be optimal.
  •  
18.
  • Mangat, J., et al. (författare)
  • A study of the image quality of computed tomography adaptive statistical iterative Reconstructed brain images using subjective and objective methods
  • 2016
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 169:1, s. 92-99
  • Tidskriftsartikel (refereegranskat)abstract
    • The recent reintroduction of iterative reconstruction in computed tomography has facilitated the realisation of major dose saving. The aim of this article was to investigate the possibility of achieving further savings at a site with well-established Adaptive Statistical iterative Reconstruction (ASiR™) (GE Healthcare) brain protocols. An adult patient study was conducted with observers making visual grading assessments using image quality criteria, which were compared with the frequency domain metrics, noise power spectrum and modulation transfer function. Subjective image quality equivalency was found in the 40-70% ASiR™ range, leading to the proposal of ranges for the objective metrics defining acceptable image quality. Based on the findings of both the patient-based and objective studies of the ASiR™/tube-current combinations tested, 60%/305 mA was found to fall within all, but one, of these ranges. Therefore, it is recommended that an ASiR™ level of 60%, with a noise index of 12.20, is a viable alternative to the currently used protocol featuring a 40% ASiR™ level and a noise index of 11.20, potentially representing a 16% dose saving. © The Author 2016. Published by Oxford University Press. All rights reserved.
  •  
19.
  • Mangat, Jasvinder, et al. (författare)
  • A study of the image quality of CT brain adaptive statistical iterative reconstructed (ASIR) images using subjective and objective methods
  • 2015
  • Ingår i: Optimisation in X-ray and Molecular Imaging 2015 - the Fourth Malmö Conference on Medical Imaging, Gothenburg, Sweden, 28-30 May 2015.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Purpose: The aim of this study was to investigate the image quality of ASIR reconstructed brain images using subjective, observer-based assessment and objective metrics to elucidate trends and possible alternatives to the current standard protocol featuring 40%ASIR and a noise index of 11.20, possibly facilitating a dose decrease. Method: An audit of image quality of patient brain scans (n=55) was performed using Visual Grading Assessment (VGA) by two radiologist-observers, using CEC image criteria of retrospectively reconstructed images at 0% -70% & 100% ASIR-levels originally scanned using the standard protocol. Analysis was conducted using Visual Grading Characteristics (VGC). Empirical phantom-based assessments of high-contrast spatial resolution (HCSR) and Noise Power Spectrum (NPS) with 0-100%ASIR increments and decrementing tube currents (565-235mA), were also conducted. Results: VGC analysis showed that the mid-range increments (50%-70%ASIR) were not significantly different to 40%ASIR (p>0.05). Low-contrast spatial resolution (LCSR) showed slight, non-significant improvement with 70% and 60%ASIR increments compared with 40%ASIR (p>0.05). Subjective image noise remained constant across this range, but was slightly worse than 40%ASIR (p>0.05). However, 70%ASIR reconstructions were found to be overly susceptible to artefact appearance. Hence pairwise-analysis was performed using 60% & 50%ASIR, which showed 60%ASIR was the preferred increment. Phantom-based HCSR investigations showed MTF50 and MTF10 increases of up-to 4.1% and 3.0%, respectively (p<0.05) for ASIR reconstructed images as compared to those produced using FBP. MTF50 and MTF10 showed a linearly improving relationship with increasing %ASIR. With tube current, MTF behaviour was more complex with a rapid increase up to 305mA, a plateau between 305 and 420mA and then a rapid fall off. The NPS study revealed peak-frequency decreased linearly with increasing %ASIR and remained constant with tube current. Peak-variance decreased non-linearly with %ASIR and tube current. Empirical ranges for MTF50, MTF10, peak frequency NPS & peak variance NPS of (0.370- 0.375mm-1), (0.617- 0.622mm-1), (0.199- 0.176mm-1) & (99.28- 84.92mm-1) respectively, were obtained for the standard protocol for the mid-range ASIR increments. Conclusion: This study demonstrated the trends for objective and subjective image quality metrics with ASIR increment and tube-current. 60%ASIR with a tube current of 305mA (NI=12.20) was proposed as an alternative to the current standard, as it was the best fit with these empirical ranges, producing a possible dose saving of 16.1%.
  •  
20.
  • Meltzer, Carin, et al. (författare)
  • Quantification of Pulmonary Pathology in Cystic Fibrosis-Comparison Between Digital Chest Tomosynthesis and Computed Tomography.
  • 2021
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 195:3-4, s. 434-442
  • Tidskriftsartikel (refereegranskat)abstract
    • Digital tomosynthesis (DTS) is currently undergoing validation for potential clinical implications. The aim of this study was to investigate the potential for DTS as a low-dose alternative to computed tomography (CT) in imaging of pulmonary pathology in patients with cystic fibrosis (CF).DTS and CT were performed as part of the routine triannual follow-up in 31 CF patients. Extent of disease was quantified according to modality-specific scoring systems. Statistical analysis included Spearman's rank correlation coefficient (r) and Krippendorff's alpha (α).The median effective dose was 0.14 for DTS and 2.68 for CT. Intermodality correlation was very strong for total score and the subscores regarding bronchiectasis and bronchial wall-thickening (r=0.82-0.91, P<0.01). Interobserver reliability was high for total score, bronchiectasis and mucus plugging (α=0.83-0.93) in DTS.Chest tomosynthesis could be a low-dose alternative to CT in quantitative estimation of structural lung disease in CF.
  •  
21.
  • Svalkvist, Angelica, et al. (författare)
  • Evaluation of an improved method of simulating lung nodules in chest tomosynthesis
  • 2012
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 53:8, s. 874-884
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Simulated pathology is a valuable complement to clinical images in studies aiming at evaluating an imaging technique. In order for a study using simulated pathology to be valid, it is important that the simulated pathology in a realistic way reflect the characteristics of real pathology. Purpose: To perform a thorough evaluation of a nodule simulation method for chest tomosynthesis, comparing the detection rate and appearance of the artificial nodules with those of real nodules in an observer performance experiment. Material and Methods: A cohort consisting of 64 patients, 38 patients with a total of 129 identified pulmonary nodules and 26 patients without identified pulmonary nodules, was used in the study. Simulated nodules, matching the real clinically found pulmonary nodules by size, attenuation, and location, were created and randomly inserted into the tomosynthesis section images of the patients. Three thoracic radiologists and one radiology resident reviewed the images in an observer performance study divided into two parts. The first part included nodule detection and the second part included rating of the visual appearance of the nodules. The results were evaluated using a modified receiver-operating characteristic (ROC) analysis. Results: The sensitivities for real and simulated nodules were comparable, as the area under the modified ROC curve (AUC) was close to 0.5 for all observers (range, 0.43-0.55). Even though the ratings of visual appearance for real and simulated nodules overlapped considerably, the statistical analysis revealed that the observers to were able to separate simulated nodules from real nodules (AUC values range 0.70-0.74). Conclusion: The simulation method can be used to create artificial lung nodules that have similar detectability as real nodules in chest tomosynthesis, although experienced thoracic radiologists may be able to distinguish them from real nodules.
  •  
22.
  •  
23.
  • Timberg, Pontus, et al. (författare)
  • Visibility of microcalcification clusters and masses in breast tomosynthesis image volumes and digital mammography: A 4AFC human observer study
  • 2012
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 39:5, s. 2431-2437
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the visibility of simulated lesions in digital breast tomosynthesis (BT) image volumes compared with 2D digital mammography (DM). Methods: Simulated lesions (masses and microcalcifications) were added to images of the same women acquired on a DM system (Mammomat Novation, Siemens) and a BT prototype. The same beam quality was used for the DM and BT acquisitions. The total absorbed dose resulting from a 25-projection BT acquisition and reconstruction (BT25) was approximately twice that of a single DM view. By excluding every other projection image from the reconstruction (BT13), approximately the same dose as in DM was effected. Simulated microcalcifications were digitally added with varying contrast to the DM and BT images. Simulated masses with 8 mm diameter were also added to BT images. A series of 4-alternative forced choice (4AFC) human observer experiments were conducted. Four medical physicists participated in all experiments, each consisting of 60 trials per experimental condition. The observers interpreted the BT image volumes in cine-mode at a fixed image sequence speed. The required threshold contrast (S-t) to achieve a detectability index (d') of 2.5 (i.e., 92.5% correct decisions) was determined. Results: The St for mass detection in DM was approximately a factor of 2 higher than required in BT indicating that the detection of masses was improved under BT conditions compared to DM. St for microcalcification detection was higher for BT than for DM at both BT dose levels (BT25 and BT13), with a statistically significant difference in St between DM and BT13. These results indicate a dose-dependent decrease in detection performance in BT for detection of microcalcifications. Conclusions: In agreement with previous investigations, masses of size 8 mm can be detected with less contrast in BT than in DM indicating improved detection performance for BT. However, for the investigated microcalcifications, the results of this study indicate potentially worse performance for BT than for DM at the same dose level. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3694105]
  •  
24.
  • Tingberg, Anders, et al. (författare)
  • Comparison of two methods for evaluation of image quality of lumbar spine radiographs
  • 2004
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 5372, s. 251-262
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Purpose To evaluate the image quality of clinical radiographs with two different methods, and to find correlations between the two methods. Methods Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. Results The VGA study showed that images with low noise are preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study the visibility of the lesions was independent of the spatial resolution and the noise level. Discussion In this study we found no correlation between the two methods, probably because the detectability of the artificial lesions was not influenced by the manipulations of noise level and resolution. Hence, the detection of lesions in lumbar spine radiography may not be a quantum-noise limited task. The results show the strength of the VGA technique in terms of detecting small changes in the two image quality parameters. The method is more robust and has a higher statistical power than the ROC related method and could therefore, in some cases, be more suitable for use in optimization studies.
  •  
25.
  •  
Skapa referenser, mejla, bekava och länka