1.
  • Kügele, Malin, et al. (författare)
  • Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy
  • 2019
  • Ingår i: Journal of Applied Clinical Medical Physics. - : Wiley. - 1526-9914. ; , s. 61-68
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of the study was to investigate if surface guided radiotherapy (SGRT) can decrease setup deviations for tangential and locoregional breast cancer patients compared to conventional laser-based setup (LBS). Materials and Methods: Both tangential (63 patients) and locoregional (76 patients) breast cancer patients were enrolled in this study. For LBS, the patients were positioned by aligning skin markers to the room lasers. For the surface based setup (SBS), an optical surface scanning system was used for daily setup using both single and three camera systems. To compare the two setup methods, the patient position was evaluated using verification imaging (field images or orthogonal images). Results: For both tangential and locoregional treatments, SBS decreased the setup deviation significantly compared to LBS (P < 0.01). For patients receiving tangential treatment, 95% of the treatment sessions were within the clinical tolerance of ≤ 4 mm in any direction (lateral, longitudinal or vertical) using SBS, compared to 84% for LBS. Corresponding values for patients receiving locoregional treatment were 70% and 54% for SBS and LBS, respectively. No significant difference was observed comparing the setup result using a single camera system or a three camera system. Conclusions: Conventional laser-based setup can with advantage be replaced by surface based setup. Daily SGRT improves patient setup without additional imaging dose to breast cancer patients regardless if a single or three camera system was used.
  •  
2.
  • Nyholm, Tufve, et al. (författare)
  • Variability in prostate and seminal vesicle delineations defined on magnetic resonance images, a multi-observer, -center and -sequence study
  • 2013
  • Ingår i: Radiation Oncology. - : BioMed Central. - 1748-717X. ; 8, s. 126-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The use of magnetic resonance (MR) imaging as a part of preparation for radiotherapy is increasing. For delineation of the prostate several publications have shown decreased delineation variability using MR compared to computed tomography (CT). The purpose of the present work was to investigate the intra- and inter-physician delineation variability for prostate and seminal vesicles, and to investigate the influence of different MR sequence settings used clinically at the five centers participating in the study.Methods: MR series from five centers, each providing five patients, were used. Two physicians from each center delineated the prostate and the seminal vesicles on each of the 25 image sets. The variability between the delineations was analyzed with respect to overall, intra-and inter-physician variability, and dependence between variability and origin of the MR images, i.e. the MR sequence used to acquire the data.Results: The intra-physician variability in different directions was between 1.3 - 1.9 mm and 3 - 4 mm for the prostate and seminal vesicles respectively (1 std). The inter-physician variability for different directions were between 0.7 - 1.7 mm and approximately equal for the prostate and seminal vesicles. Large differences in variability were observed for individual patients, and also for individual imaging sequences used at the different centers. There was however no indication of decreased variability with higher field strength.Conclusion: The overall delineation variability is larger for the seminal vesicles compared to the prostate, due to a larger intra-physician variability. The imaging sequence appears to have a large influence on the variability, even for different variants of the T2-weighted spin-echo based sequences, which were used by all centers in the study.
  •  
3.
  • Ottosson, Rickard, et al. (författare)
  • The feasibility of using Pareto fronts for comparison of treatment planning systems and delivery techniques
  • 2009
  • Ingår i: Acta Oncologica. - : Informa UK Limited. - 0284-186X .- 1651-226X. ; 48:2, s. 233-237
  • Tidskriftsartikel (refereegranskat)abstract
    • Pareto optimality is a concept that formalises the trade-off between a given set of mutually contradicting objectives. A solution is said to be Pareto optimal when it is not possible to improve one objective without deteriorating at least one of the other. A set of Pareto optimal solutions constitute the Pareto front. The Pareto concept applies well to the inverse planning process, which involves inherently contradictory objectives, high and uniform target dose on one hand, and sparing of surrounding tissue and nearby organs at risk (OAR) on the other. Due to the specific characteristics of a treatment planning system (TPS), treatment strategy or delivery technique, Pareto fronts for a given case are likely to differ. The aim of this study was to investigate the feasibility of using Pareto fronts as a comparative tool for TPSs, treatment strategies and delivery techniques. In order to sample Pareto fronts, multiple treatment plans with varying target conformity and dose sparing of OAR were created for a number of prostate and head neck IMRT cases. The DVHs of each plan were evaluated with respect to target coverage and dose to relevant OAR. Pareto fronts were successfully created for all studied cases. The results did indeed follow the definition of the Pareto concept, i.e. dose sparing of the OAR could not be improved without target coverage being impaired or vice versa. Furthermore, various treatment techniques resulted in distinguished and well separated Pareto fronts. Pareto fronts may be used to evaluate a number of parameters within radiotherapy. Examples are TPS optimization algorithms, the variation between accelerators or delivery techniques and the degradation of a plan during the treatment planning process. The issue of designing a model for unbiased comparison of parameters with such large inherent discrepancies, e.g. different TPSs, is problematic and should be carefully considered. fc.
  •  
4.
  • Stervik, Louise, 1993, et al. (författare)
  • Analysis of early respiratory-related mortality after radiation therapy of non-small-cell lung cancer : feasibility of automatic data extraction for dose–response studies
  • 2020
  • Ingår i: Acta Oncologica. - 0284-186X. ; 59:6, s. 628-635
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To examine the feasibility of automatic data extraction from clinical radiation therapy (RT) databases at four hospitals to investigate the impact of mean lung dose (MLD) and age on the risk of early respiratory-related death and early overall death for patients treated with RT for non-small-cell lung cancer (NSCLC). Material and methods: We included adult patients with NSCLC receiving curatively intended RT between 2002 and 2017 at four hospitals. A script was developed to automatically extract RT-related data. The cause of death for patients deceased within 180 days of the start of RT was retrospectively assessed. Using logistic regression, the risks of respiratory-related death and of overall death within 90 and 180 days were investigated using MLD and age as variables. Results: Altogether, 1785 patients were included in the analysis of early overall mortality and 1655 of early respiratory-related mortality. The respiratory-related mortalities within 90 and 180 days were 0.9% (15/1655) and 3.6% (60/1655). The overall mortalities within 90 and 180 days were 2.5% (45/1785) and 10.6% (190/1785). Higher MLD and older age were associated with an increased risk of respiratory-related death within 180 days and overall death within 90 and 180 days (all p<.05). For example, the risk of respiratory-related death within 180 days and their 95% confidence interval for patients aged 65 and 75 years with MLDs of 20 Gy was according to our logistic model 3.8% (2.6–5.0%) and 7.7% (5.5–10%), respectively. Conclusions: Automatic data extraction was successfully used to pool data from four hospitals. MLD and age were associated with the risk of respiratory-related death within 180 days of the start of RT and with overall death within 90 and 180 days. A model quantifying the risk of respiratory-related death within 180 days was formulated.
  •  
5.
  •  
6.
  • Thor, Maria, et al. (författare)
  • Introducing multiple treatment plan-based comparison to investigate the performance of gantry angle optimisation (GAO) in IMRT for head and neck cancer
  • 2012
  • Ingår i: Acta Oncologica. - 1651-226X. ; 51:6, s. 743-751
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose. The purpose of this study was to evaluate the performance of gantry angle optimisation (GAO) compared to equidistant beam geometry for two inverse treatment planning systems (TPSs) by utilising the information obtained from a range of treatment plans. Material and methods. The comparison was based on treatment plans generated for four different head and neck (H&N) cancer cases using two inverse treatment planning systems (TPSs); Varian Eclipse (TM) representing dynamic MLC intensity modulated radiotherapy (IMRT) and Oncentra (R) Masterplan representing segmented MLC-based IMRT. The patient cases were selected on the criterion of representing different degrees of overlap between the planning target volume (PTV) and the investigated organ at risk, the ipsilateral parotid gland. For each case, a number of 'Pareto optimal' plans were generated in order to investigate the trade-off between the under-dosage to the PTV (V-PTV,V-D (< 95%)) or the decrease in dose homogeneity (D-5-D-95) to the PTV as a function of the mean absorbed dose to the ipsilateral parotid gland (< D >(parotid gland)). Results. For the Eclipse system, GAO had a clear advantage for the cases with smallest overlap (Cases 1 and 2). The set of data points, representing the underlying trade-offs, generated with and without using GAO were, however, not as clearly separated for the cases with larger overlap (Cases 3 and 4). With the OMP system, the difference was less pronounced for all cases. The Eclipse GAO displays the most favourable trade-off for all H&N cases. Conclusions. We have found differences in the effectiveness of GAO as compared to equidistant beam geometry, in terms of handling conflicting trade-offs for two commercial inverse TPSs. A comparison, based on a range of treatment plans, as developed in this study, is likely to improve the understanding of conflicting trade-offs and might apply to other thorough comparison techniques.
  •  
Skapa referenser, mejla, bekava och länka