SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Björkhage Mikael) "

Sökning: WFRF:(Björkhage Mikael)

  • Resultat 1-25 av 25
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Amann, Peter, et al. (författare)
  • A dedicated photoelectron spectroscopy instrument for studies of catalytic reactions at pressures exceeding 1 bar
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • Here, we present a new high-pressure x-ray photoelectron spectroscopy system dedicated to probing catalytic reactions under realistic conditions at pressures exceeding 1 bar. The instrument builds around the concept of a “virtual cell” in which a gasflow is directed onto the sample surface creating a local high pressure on top of the sample. This allows the instrument to maintain a low pressure of a few mbars in the main chamber, while simultaneously keeping a local pressure of around 1 bar. Synchrotron radiation based grazing incidence photoemission within ± 5° is used to enhance the surface sensitivity in the experiment. The aperture, separating the high-pressure region from the differential pumping of the electron spectrometer, consists of multiple, evenly spaced, mm sized holes matching the footprint of the x-ray beam on the sample surface. As the photo-emitted electrons are subject to strong scattering in the gas phase and the resulting signal is therefore highly dependent on the sample to aperture distance, the latter is controlled with high precision using a fully integrated manipulator that allows for sample movement with step sizes of 10 nm between 0 and –5 mm with very low vibrational amplitude. The instrumental features allows acquisition of metallic bulk spectra at He pressures up to 2.5 bar and also allows for following C1s spectra under realistic gas mixtures of CO + H2with various temperatures up to 500°C. This capability opens for studies of catalytic reactions in operandi.
  •  
2.
  • Amann, Peter, et al. (författare)
  • A high-pressure x-ray photoelectron spectroscopy instrument for studies of industrially relevant catalytic reactions at pressures of several bars
  • 2019
  • Ingår i: Review of Scientific Instruments. - : American Institute of Physics (AIP). - 0034-6748 .- 1089-7623. ; 90:10
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a new high-pressure x-ray photoelectron spectroscopy system dedicated to probing catalytic reactions under realistic conditions at pressures of multiple bars. The instrument builds around the novel concept of a "virtual cell" in which a gas flow onto the sample surface creates a localized high-pressure pillow. This allows the instrument to be operated with a low pressure of a few millibar in the main chamber, while simultaneously a local pressure exceeding 1 bar can be supplied at the sample surface. Synchrotron based hard x-ray excitation is used to increase the electron mean free path in the gas region between sample and analyzer while grazing incidence <5 degrees close to total external refection conditions enhances surface sensitivity. The aperture separating the high-pressure region from the differential pumping of the electron spectrometer consists of multiple, evenly spaced, micrometer sized holes matching the footprint of the x-ray beam on the sample. The resulting signal is highly dependent on the sample-to-aperture distance because photoemitted electrons are subject to strong scattering in the gas phase. Therefore, high precision control of the sample-to-aperture distance is crucial. A fully integrated manipulator allows for sample movement with step sizes of 10 nm between 0 and -5 mm with very low vibrational amplitude and also for sample heating up to 500 degrees C under reaction conditions. We demonstrate the performance of this novel instrument with bulk 2p spectra of a copper single crystal at He pressures of up to 2.5 bars and C1s spectra measured in gas mixtures of CO + H-2 at pressures of up to 790 mbar. The capability to detect emitted photoelectrons at several bars opens the prospect for studies of catalytic reactions under industrially relevant operando conditions.
  •  
3.
  • Bäckström, Erik, 1983-, et al. (författare)
  • Storing keV negative ions for an hour : The lifetime of the metastable 2P1/2 level in 32S−
  • 2015
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 114:14
  • Tidskriftsartikel (refereegranskat)abstract
    • We use a novel electrostatic ion storage ring to measure the radiative lifetime of the upper level in the 3p 5  P 2  o 1/2 →3p 5  P 2  o 3/2   spontaneous radiative decay in S −  32   to be 503±54  sec . This is by orders of magnitude the longest lifetime ever measured in a negatively charged ion. Cryogenic cooling of the storage ring gives a residual-gas pressure of a few times 10 −14   mbar at 13 K and storage of 10 keV sulfur anions for more than an hour. Our experimental results differ by 1.3σ  from the only available theoretical prediction.
  •  
4.
  • Chartkunchand, Kiattichart C., et al. (författare)
  • Dianion diagnostics in DESIREE : High-sensitivity detection of C-n(2-) from a sputter ion source
  • 2018
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 89:3
  • Tidskriftsartikel (refereegranskat)abstract
    • A sputter ion source with a solid graphite target has been used to produce dianions with a focus on carbon cluster dianions, C-n(2-), with n = 7-24. Singly and doubly charged anions from the source were accelerated together to kinetic energies of 10 keV per atomic unit of charge and injected into one of the cryogenic (13 K) ion-beam storage rings of the Double ElectroStatic Ion Ring Experiment facility at Stockholm University. Spontaneous decay of internally hot C-n(2-) dianions injected into the ring yielded C-n(2-) anions with kinetic energies of 20 keV, which were counted with a microchannel plate detector. Mass spectra produced by scanning the magnetic field of a 90 degrees analyzing magnet on the ion injection line reflect the production of internally hot C-7(2-) - C-24(2-) dianions with lifetimes in the range of tens of microseconds to milliseconds. In spite of the high sensitivity of this method, no conclusive evidence of C-6(2-) was found while there was a clear C-7(2-) signal with the expected isotopic distribution. This is consistent with earlier experimental studies and with theoretical predictions. An upper limit is deduced for a C-6(2-) signal that is two orders-of-magnitude smaller than that for C-7(2-). In addition, CnO2- and CnCu2- dianions were detected.
  •  
5.
  • Chartkunchand, Kiattichart C., et al. (författare)
  • Radiative lifetimes of the bound excited states of Pt-
  • 2016
  • Ingår i: Physical Review A - Atomic, Molecular, and Optical Physics. - 1050-2947 .- 1094-1622. ; 94:3
  • Tidskriftsartikel (refereegranskat)abstract
    • © 2016 American Physical Society.The intrinsic radiative lifetimes of the 5d106sS1/22 and 5d96s2 D3/22 bound excited states in the platinum anion Pt- have been studied at cryogenic temperatures at the Double ElectroStatic Ion Ring Experiment (DESIREE) facility at Stockholm University. The intrinsic lifetime of the higher-lying 5d106s S1/22 state was measured to be 2.54±0.10s, while only a lifetime in the range of 50-200 ms could be estimated for the 5d96s2 D3/22 fine-structure level. The storage lifetime of the Pt- ion beam was measured to be a little over 15 min at a ring temperature of 13K. The present study reports the lifetime of an atomic negative ion in an excited bound state with an electron configuration different from that of the ground state.
  •  
6.
  • Eklund, Gustav, et al. (författare)
  • Cryogenic merged-ion-beam experiments in DESIREE : Final-state-resolved mutual neutralization of Li+ and D-
  • 2020
  • Ingår i: Physical Review A: covering atomic, molecular, and optical physics and quantum information. - : American Physical Society (APS). - 2469-9926 .- 2469-9934. ; 102:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed an experimental technique to study charge-and energy-flow processes in sub-eV collisions between oppositely charged, internally cold, ions of atoms, molecules, and clusters. Two ion beams are stored in separate rings of the cryogenic ion-beam storage facility DESIREE, and merged in a common straight section where a set of biased drift tubes is used to control the center-of-mass collision energy locally in fine steps. Here, we present measurements on mutual neutralization between Li+ and D- where a time-sensitive imaging-detector system is used to measure the three-dimensional distance between the neutral Li and D atoms as they reach the detector. This scheme allows for direct measurements of kinetic-energy releases, and here it reveals separate populations of the 3s state and the (3p + 3d) states in neutral Li while the D atom is left in its ground state 1s. The branching fraction of the 3s final state is measured to be 57.8 +/- 0.7% at a center-of-mass collision energy of 78 +/- 13 meV. The technique paves the way for studies of charge-, energy-, and mass-transfer reactions in single collisions involving molecular and cluster ions in well-defined quantum states.
  •  
7.
  • Gatchell, Michael, et al. (författare)
  • Commissioning of the DESIREE storage rings - a new facility for cold ion-ion collisions
  • 2014
  • Ingår i: XXVIII International Conference on Photonic, Electronic and Atomic Collisions (ICPEAC 2013). - : Institute of Physics (IOP). ; 488:1
  • Konferensbidrag (refereegranskat)abstract
    • We report on the ongoing commissioning of the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. Beams of atomic carbon anions (C-) and smaller carbon anion molecules (C-2(-), C-3(-), C-4(-) etc.) have been produced in a sputter ion source, accelerated to 10 keV or 20 keV, and stored successfully in the two electrostatic rings. The rings are enclosed in a common vacuum chamber cooled to below 13 Kelvin. The DESIREE facility allows for studies of internally relaxed single isolated atomic, molecular and cluster ions and for collision experiments between cat-and anions down to very low center-of-mass collision energies (meV scale). The total thermal load of the vacuum chamber at this temperature is measured to be 32 W. The decay rates of stored ion beams have two components: a non-exponential component caused by the space charge of the beam itself which dominates at early times and an exponential term from the neutralization of the beam in collisions with residual gas at later times. The residual gas limited storage lifetime of carbon anions in the symmetric ring is over seven minutes while the 1/e lifetime in the asymmetric ring is measured to be about 30 seconds. Although we aim to improve the storage in the second ring, the number of stored ions are now sufficient for many merged beams experiments with positive and negative ions requiring milliseconds to seconds ion storage.
  •  
8.
  • Gatchell, Michael, et al. (författare)
  • First results from the Double ElectroStatic Ion-Ring ExpEriment, DESIREE
  • 2014
  • Ingår i: XXVIII International Conference on Photonic, Electronic and Atomic Collisions (ICPEAC 2013). - : Institute of Physics (IOP). ; 488
  • Konferensbidrag (refereegranskat)abstract
    • We have stored the first beams in one of the rings of the double electrostatic ion-storage ring, DESIREE at cryogenic and at room temperature conditions. At cryogenic operations the following parameters are found. Temperature; T= 13K, pressure; p <10(-13) mbar, initial number of stored ions; N > 10(7) and storage lifetime of a C-2(-) beam; tau = 450 S.
  •  
9.
  • Hartman, Henrik, et al. (författare)
  • First storage of ion beams in the Double Electrostatic Ion-Ring Experiment : DESIREE
  • 2013
  • Ingår i: Review of Scientific Instruments. - : American Institute of Physics (AIP). - 0034-6748 .- 1089-7623. ; 84:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (Cn-, n = 1, 2, 3, 4) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For 10 keV C2- molecular anions we measure the residual-gas limited beam storage lifetime to be 448 s +/- 18 s with two independent detector systems. Using the measured storage lifetimes we estimate that the residual gas pressure is in the 10-14 mbar range. When high current ion beams are injected, the number of stored particles does not follow a single exponential decay law as would be expected for stored particles lost solely due to electron detachment in collision with the residual-gas. Instead, we observe a faster initial decay rate, which we ascribe to the effect of the space charge of the ion beam on the storage capacity.
  •  
10.
  • Kamińska, Magdalena, et al. (författare)
  • Lifetime of the bound excited level in Ni
  • 2016
  • Ingår i: Physical Review A. - 1050-2947 .- 1094-1622. ; 93:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The intrinsic lifetime of the upper level in the bound-bound 3d(9) 4s(2) D-2(3/2) -> 3d(9) 4s(2) D-2(5/2) radiative transition in Ni- was measured to be 15.1 +/- 0.4 s. The experiment was performed at cryogenic temperatures in one of the ion-beam storage rings of the Double ElectroStatic Ion Ring ExpEriment facility at Stockholm University. The storage lifetime of the Ni- ion beam was measured to be close to 5 min at a ring temperature of 13 K.
  •  
11.
  •  
12.
  • Kristiansson, Moa K., 1989-, et al. (författare)
  • High-precision electron affinity of oxygen
  • 2022
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 13:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Negative ions are important in many areas of science and technology, e.g., in interstellar chemistry, for accelerator-based radionuclide dating, and in anti-matter research. They are unique quantum systems where electron-correlation effects govern their properties. Atomic anions are loosely bound systems, which with very few exceptions lack optically allowed transitions. This limits prospects for high-resolution spectroscopy, and related negative-ion detection methods. Here, we present a method to measure negative ion binding energies with an order of magnitude higher precision than what has been possible before. By laser-manipulation of quantum-state populations, we are able to strongly reduce the background from photodetachment of excited states using a cryogenic electrostatic ion-beam storage ring where keV ion beams can circulate for up to hours. The method is applicable to negative ions in general and here we report an electron affinity of 1.461 112 972(87) eV for O-16. High-precision measurements are useful to find isotopic shifts and electron correlation. Here the authors measure electron affinity and hyperfine splitting of atomic oxygen with higher precision than previous studies.
  •  
13.
  •  
14.
  • Schmidt, Henning, et al. (författare)
  • DESIREE as a new tool for interstellar ion chemistry
  • 2008
  • Ingår i: International Journal of Astrobiology. - 1473-5504 .- 1475-3006. ; 7:3-4, s. 205-208
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel cryogenic electrostatic storage device consisting of two ion-beam storage rings with a common straight section for studies of interactions between oppositely charged ions at low and well-defined relative velocities is under construction at Stockholm University. Here we consider the prospect of using this new tool to measure cross-sections and rate coefficients for mutual neutralization reactions of importance in interstellar ion chemistry in general and specifically in cosmic pre-biotic ion chemistry.
  •  
15.
  •  
16.
  • Schmidt-May, Alice F., 1988-, et al. (författare)
  • State-resolved mutual neutralization of 16O+ with 1H− and 2H− at collision energies below 100 meV
  • 2024
  • Ingår i: Physical Review A: covering atomic, molecular, and optical physics and quantum information. - 2469-9926 .- 2469-9934. ; 109:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We measured the product-state distribution and its dependence on the hydrogen isotope for the mutual neutralization between 16O+ and 1,2H− at the double electrostatic ion-beam storage ring DESIREE for center-of-mass collision energies below 100 meV. We find at least six product channels into ground-state hydrogen and oxygen in different excited states. The majority of oxygen products populate terms corresponding to 2⁢?22⁢?3⁢(4?∘)⁢4⁢? with 5S∘ as the main reaction product. We also observe product channels into terms corresponding to 2⁢?22⁢?3⁢(4?)⁢3⁢?. Collisions with the heavier hydrogen isotope yield a branching into these lower excited states smaller than collisions with 1H−. The observed reaction products agree with the theoretical predictions. The detailed branching fractions, however, differ between the theoretical results, and none of them fully agree with the experiment.
  •  
17.
  • Thomas, Richard D., et al. (författare)
  • DESIREE : Physics with cold stored ion beams
  • 2015
  • Ingår i: DR2013. - : EDP Sciences. ; 84, s. 01004-01004
  • Konferensbidrag (refereegranskat)abstract
    • Here we will briefly describe the commissioning of the Double ElectroStatic Ion Ring ExpEriment (DESIREE) facility at Stockholm University, Sweden. This device uses purely electrostatic focussing and deflection elements and allows ion beams of opposite charge to be confined under extreme high vacuum and cryogenic conditions in separate rings and then merged over a common straight section. This apparatus allows for studies of interactions between cations and anions at very low and well-defined centre-of-mass energies (down to a few meV) and at very low internal temperatures (down to a few K).
  •  
18.
  • Thomas, Richard D., et al. (författare)
  • The double electrostatic ion ring experiment : A unique cryogenic electrostatic storage ring for merged ion-beams studies
  • 2011
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 82:6, s. 065112-
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe the design of a novel type of storage device currently under construction at Stockholm University, Sweden, using purely electrostatic focussing and deflection elements, in which ion beams of opposite charges are confined under extreme high vacuum cryogenic conditions in separate rings and merged over a common straight section. The construction of this double electrostatic ion ring experiment uniquely allows for studies of interactions between cations and anions at low and well-defined internal temperatures and centre-of-mass collision energies down to about 10 K and 10 meV, respectively. Position sensitive multi-hit detector systems have been extensively tested and proven to work in cryogenic environments and these will be used to measure correlations between reaction products in, for example, electron-transfer processes. The technical advantages of using purely electrostatic ion storage devices over magnetic ones are many, but the most relevant are: electrostatic elements which are more compact and easier to construct; remanent fields, hysteresis, and eddy-currents, which are of concern in magnetic devices, are no longer relevant; and electrical fields required to control the orbit of the ions are not only much easier to create and control than the corresponding magnetic fields, they also set no upper mass limit on the ions that can be stored. These technical differences are a boon to new areas of fundamental experimental research, not only in atomic and molecular physics but also in the boundaries of these fields with chemistry and biology. For examples, studies of interactions with internally cold molecular ions will be particular useful for applications in astrophysics, while studies of solvated ionic clusters will be of relevance to aeronomy and biology.
  •  
19.
  • Bergström, I, et al. (författare)
  • High-precision Mass Measurements of Hydrogen-Like 24Mg11+ and 26Mg11+ ions in a Pening Trap
  • 2002
  • Ingår i: European Physical Journal D. - : Springer Science and Business Media LLC. - 1434-6060 .- 1434-6079. ; 22:1, s. 41-45
  • Tidskriftsartikel (refereegranskat)abstract
    • For the determination of the bound-electron g factor in hydrogen-like heavy ions the mass of the ion is needed at a relative uncertainty of at least 1 ppb. With the SMILETRAP Penning trap mass spectrometer at the Manne Siegbahn Laboratory in Stockholm several mass measurements of ions with even-even nuclei at this level of precision have been performed so far, exploiting the fact that the mass precision increases linearly with the ion charge. Measurements of masses of the hydrogen-like ions of the two Mg-isotopes 24Mg and 26Mg are reported. The masses of the hydrogen-like ions are 23.979011054(14) u and 25.976562354(34) u, corresponding to the atomic masses 23.985041690(14) u and 25.982592986(34) u, respectively. The possibility to use these two isotopes for the first observation of an isotope effect in the bound-electron g factor in hydrogen-like heavy ions is discussed.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  • Reinhed, Peter, et al. (författare)
  • Cryogenic keV ion-beam storage in ConeTrap - a tool for ion-temperature control
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier B.V.. - 0168-9002 .- 1872-9576. ; 621:1-3, s. 83-90
  • Tidskriftsartikel (refereegranskat)abstract
    • We have tested the ion-storage capabilities of the compact triple-electrode electrostatic ion-beam trap, ConeTrap, down to cryogenic temperatures. The low-temperature operation of this electrostatic storage device is an important test for the double electrostatic ion-ring experiment, DESIREE, which is presently under construction at Stockholm University. In the present work we measured the pressure dependent storage lifetimes of 2.5 keV He+ and 2.8 keV Ar+ ion beams in ConeTrap at temperatures down to 28 K and pressures down to 1.3·10-10 mbar. The so far longest measured ion storage lifetime using this system is 21.5±3.8 s for Ar+ ions. The present combination of ConeTrap and the cryogenic experimental chamber was recently applied in the first black-body correction-free measurement of the lifetime of the metastable He- ion at 10 K [Phys. Rev. Lett. 103, 213002(2009)].
  •  
24.
  • Reinhed, Peter, et al. (författare)
  • Precision lifetime measurements of He- in a cryogenic electrostatic ion-beam trap
  • 2009
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 103:21, s. 213002-
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed a small purely electrostatic ion-beam trap which may be operated in thermal equilibrium at precisely controlled temperatures down to 10 K. Thus, we avoid magnetic field induced mixing of quantum states and may effectively eliminate any influence from absorption of photons from black-body radiation. We report the first correction free measurements of the lifetimes of the 1s2s2p 4PoJ state of 4He- and the high precision result 359.0±0.7 μs for the J=5/2 level. The lifetimes for the J=3/2 and J=1/2 levels are determined to be 12.3±0.5 and 7.8±1.0 μs, respectively.
  •  
25.
  • Stockett, Mark H., et al. (författare)
  • Storage time dependent photodissociation action spectroscopy of polycyclic aromatic hydrocarbon cations in the cryogenic electrostatic storage ring DESIREE
  • 2019
  • Ingår i: Faraday discussions. - : Royal Society of Chemistry (RSC). - 1359-6640 .- 1364-5498. ; 217, s. 126-137
  • Tidskriftsartikel (refereegranskat)abstract
    • The multi-photon photodissociation action spectrum of the coronene cation (C24H12+) has been measured in the cryogenic electrostatic storage ring DESIREE (Double ElectroStatic Ion Ring ExpEriment) as a function of storage time. These measurements reveal not only the intrinsic absorption profile of isolated coronene cations, but also the rate at which hot-band absorptions are quenched by radiative cooling. Just after injection, the action spectrum is severely reddened by hot-band absorptions. These hot bands fade with a time constant of 200 ms, which is consistent with radiative cooling via infrared emission from vibrational transitions. A comparison of the present results to those obtained in cryogenic ion trap experiments is discussed at length.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-25 av 25
Typ av publikation
tidskriftsartikel (17)
annan publikation (4)
konferensbidrag (4)
Typ av innehåll
refereegranskat (20)
övrigt vetenskapligt/konstnärligt (4)
populärvet., debatt m.m. (1)
Författare/redaktör
Björkhage, Mikael (24)
Blom, Mikael (17)
Cederquist, Henrik (17)
Schmidt, Henning T. (15)
Rosén, Stefan (15)
Löfgren, Patrik (14)
visa fler...
Zettergren, Henning (12)
Thomas, Richard D. (10)
Hanstorp, Dag, 1960 (8)
Alexander, John D. (8)
Larsson, Mats (7)
Kamińska, Magdalena (7)
Stockett, Mark H. (6)
Hellberg, Fredrik (5)
Grumer, Jon (5)
Danared, Håkan (5)
Schuch, Reinhold (4)
Eklund, Gustav (4)
Gatchell, Michael (4)
Chen, Tao (4)
Hansen, Klavs, 1958 (3)
Barklem, Paul S. (3)
Anderson, Emma K. (3)
Chartkunchand, Kiatt ... (3)
Geppert, Wolf D. (3)
Fritioff, Tomas (3)
Nagy, Szilard (3)
Johansson, Henrik (2)
Nilsson, Anders (2)
Davis, V. T. (2)
Shipilin, Mikhail (2)
Geppert, Wolf (2)
Amann, Peter (2)
Lee, Ming-Tao (2)
Wang, Hsin-Yi (2)
Cavalca, Filippo (2)
Weston, Matthew (2)
Gladh, Jörgen (2)
Schlueter, Christoph (2)
Ederer, Katrin (2)
Noei, Heshmat (2)
Zehetner, Johann (2)
Wentzel, Henrik (2)
Rosén, Stefan, 1967- (2)
Cederquist, Henrik, ... (2)
Zettergren, Henning, ... (2)
Schmidt, Henning T., ... (2)
Bergström, Ingmar (2)
Bagge, Lars (2)
Schmidt, Henning (2)
visa färre...
Lärosäte
Stockholms universitet (25)
Göteborgs universitet (9)
Malmö universitet (3)
Uppsala universitet (2)
Lunds universitet (2)
Kungliga Tekniska Högskolan (1)
Språk
Engelska (22)
Odefinierat språk (2)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (21)
Medicin och hälsovetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy