SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bjørnerud Atle) "

Sökning: WFRF:(Bjørnerud Atle)

  • Resultat 1-24 av 24
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Bjørnerud, Atle, et al. (författare)
  • Assessment of T1 and T2* effects in vivo and ex vivo using iron oxide nanoparticles in steady state : dependence on blood volume and water exchange
  • 2002
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 47:3, s. 461-471
  • Tidskriftsartikel (refereegranskat)abstract
    • Accurate knowledge of the relationship between contrast agent concentration and tissue relaxation is a critical requirement for quantitative assessment of tissue perfusion using contrast-enhanced MRI. In the present study, using a pig model, the relationship between steady-state blood concentration levels of an iron oxide nanoparticle with a hydrated diameter of 12 nm (NC100150 Injection) and changes in the transverse and longitudinal relaxation rates (1/T2* and 1/T1, respectively) in blood, muscle, and renal cortex was investigated at 1.5 T. Ex vivo measurements of 1/T2* and 1/T1 were additionally performed in whole pig blood spiked with different concentrations of the iron oxide nanoparticle. In renal cortex and muscle, 1/T2* increased linearly with contrast agent concentration with slopes of 101 +/-22 s(-1)mM(-1) and 6.5 +/-0.9 s(-1)mM(-1) (mean +/- SD), respectively. In blood, 1/T2* increased as a quadratic function of contrast agent concentration, with different quadratic terms in the ex vivo vs. the in vivo experiments. In vivo, 1/T1 in blood increased linearly with contrast agent concentration, with a slope (T1-relaxivity) of 13.9 +/- 0.9 s(-1)mM(-1). The achievable increase in 1/T1 in renal cortex and muscle was limited by the rate of water exchange between the intra- and extravascular compartments and the 1/T1-curves were well described by a two-compartment water exchange limited relaxation model.
  •  
4.
  • Bjørnerud, Atle, 1962- (författare)
  • Proton Relaxation Properties of a Particulate Iron Oxide MR Contrast Agent in Different Tissue Systems : Implications for Imaging
  • 2002
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Knowledge of the relationship between in vivo contrast agent concentration and magnetic resonance (MR) signal response is an important requirement in contrast enhanced MR imaging in general and in MR based perfusion imaging in particular. This relationship is a complex function of the properties of the contrast agent as well as the structure of the target tissue. The aim of the present work was to quantify the effects of the iron oxide nanoparticle based intravascular contrast agent, NC100150 Injection, on proton relaxation rates in different tissue systems in vivo in a pig model and ex vivo in phantoms containing whole blood. Methods that enabled accurate relaxation rate measurements in these organs were developed, and validated. From these measurements, trans-compartmental water exchange rates and blood volume could be estimated and the MR signal response could be predicted as a function of contrast agent concentration under relevant imaging conditions. Using a 1.5 Tesla clinical MR system, the longitudinal (R1=1/T1) proton relaxation rates in blood, renal cortex, paraspinal muscle and myocardium were measured in vivo as a function of plasma concentration (Cp) of NC100150 Injection. The transverse (R2* = 1/T2*) relaxation rates were measured in vivo in blood, renal cortex and muscle as a function of Cp and ex vivo in blood as a function of Cp and blood oxygenation tension. The proton nuclear MR (NMR) linewidth and lineshape were analysed as a function of Cp and blood oxygen tension ex vivo at 7.05 T. In muscle and renal cortex, there was a linear correlation between R2* and Cp whereas R2* increased as a quadratic function of Cp in blood. The NMR linewidth increased linearly with Cp in fully oxygenated blood whereas in deoxygenated blood the linewidth initially decreased with increasing Cp, reaching a minimum and then increasing again with further increase in Cp. R1 increased linearly with Cp in blood and from the slope of R1 vs. Cp the T1-relaxivity (r1) of NC100150 Injection in blood at 1.5 T was estimated to be (mean ± SD) 13.9 ± 0.9 s-1mM-1. In tissue, the maximum increase in R1 was limited by the rate of water exchange between the intravascular and interstitial tissue compartments. Using a two-compartment exchange-limited relaxation model, the permeability surface area (PS) product was estimated to be 61.9 ± 2.9 mL/min/g in renal cortex and 10.1 ± 1.5 mL/min/g in muscle and the total myocardial water exchange rate, kt, was 13.5 ± 6.4 s-1. The estimated blood volumes obtained from the same model were 19.1 ± 1.4 mL/100 g, 2.4 ± 1.4 mL/100 g and 11.2 ± 2.1 mL/100 g, respectively in renal cortex, muscle and myocardium.Current T2* based first-pass MR perfusion methods assume a linear correlation between R2* and Cp both in blood and tissue and our results therefore suggest that quantitative perfusion values can not easily be obtained with existing tracer kinetic models. The correlation between MR signal response and Cp is further complicated in the kidney by a significant first-pass increase in R1 which may lead to an underestimation of Cp. In T1-based perfusion methods, low concentrations of NC100150 Injection must be used in order to maintain a linear dose-response relationship between R1 and Cp. The effect of blood oxygenation on the NMR linewidth in the presence of NC100150 Injection enabled accurate estimation of magnetic susceptibility of deoxyhemoglobin and the effect can potentially be used to determine blood oxygenation status.In conclusion, NC100150 Injection is well suited as a T2* perfusion agent due to the large magnetisation and intravascular biodistribution of this agent. T1-based perfusion imaging with this agent is limited by water exchange effects and large T2* effects at higher contrast agent concentrations. Quantitative perfusion assessment is unlikely to be feasible with any of these approaches due to the non-linear dose response.
  •  
5.
  • Bjørnerud, Atle, et al. (författare)
  • Renal T(*)(2) perfusion using an iron oxide nanoparticle contrast agent : influence of T(1) relaxation on the first-pass response
  • 2002
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 47:2, s. 298-304
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantitative perfusion measurements require accurate knowledge of the correlation between first-pass signal changes and the corresponding tracer concentration in tissue. In the present study, a detailed analysis of first-pass renal cortical changes in T(1) and T(*)(2) following bolus injection of the iron oxide nanoparticle NC100150 Injection was investigated in a pig model using a double-echo gradient-echo sequence. The estimated change in 1/T(*)(2) during first pass calculated from single-echo sequences was compared to the true double-echo-derived 1/T(*)(2) curves. Using a single-echo (TE = 6 ms) spoiled gradient-echo sequence, the first-pass 1/T(*)(2) response following a bolus injection of 1 mg Fe/kg of NC100150 Injection was significantly underestimated due to counteracting T(1) effects. Signal response simulations showed that the relative error in the first-pass response decreased with increasing TE and contrast agent dose. However, both the maximum TE and the maximum dose are limited by excessive cortical signal loss, and the maximum TE is further limited by high temporal resolution requirements. The problem of T(1) contamination can effectively be overcome by using a double-echo gradient-echo sequence. This yields a first-pass response that truly reflects the tissue tracer concentration, which is a critical requirement for quantitative renal perfusion assessment.
  •  
6.
  •  
7.
  •  
8.
  • Briley Saebo, Karen, 1964- (författare)
  • Degradation, Metabolism and Relaxation Properties of Iron Oxide Particles for Magnetic Resonance Imaging
  • 2004
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Whereas the effect of size and coating material on the pharmacokinetics and biodistribution of iron oxide based contrast agents are well documented, the effect of these parameters on liver metabolism has never been investigated. The primary purpose of this work was to evaluate the effect of iron oxide particle size and coating on the rate of liver clearance and particle degradation using a rat model. The magnetic and relaxation properties of five different iron oxide contrast agents were determined prior to the onset of the animal studies. The R2* values and the T1-enhancing efficacy of the agents were also evaluated in blood using phantom models. The results of these studies indicated that the efficacy of these agents was matrix and frequency dependent. Correlations between the R2* values and the magnetic properties of the agents were established and a new parameter, Msat/r1, was created to enable better estimations of contrast agent T1-enhancing efficacy in blood. The bio-distribution of one of the agents was also evaluated to assess the importance of sub-cellular particle distribution, using an isolated rat liver cell model. Phantom models were also used to verify that materials with magnetic properties similar to the particle breakdown products (ferritin/hemosiderin) may induce signal reduction when compartmentalized in a liver cell suspension. The results revealed that the cellular distribution of the agent did not influence the rate of particle degradation. This finding conflicted with current theory. Additionally, the study indicated that the compartmentalization of magnetic materials similar to ferritin may induce significant signal loss.Methods enabling the accurate determination of contrast agent concentration in the liver were developed and validated using one of the agents. From these measurements the liver half-life of the agent was estimated and compared to the rate of liver clearance, as determined from the evolution of the effective transverse relaxation rate (R2*) in rat liver. The results indicate that the liver R2* enhancement persisted at time points when the concentration of contrast agent present in the liver was below method detection limits. The prolonged R2* enhancement was believed to be a result of the compartmentalisation of the particle breakdown products within the liver cells. Finally, the liver clearance and degradation rates of the five different iron oxide particles in rat liver were evaluated. The results revealed that for materials with similar iron oxide cores and particle sizes, the rate of liver clearance was affected by the coating material present. Materials with similar coating, but different sizes, exhibited similar rates of liver clearance.In conclusion, the results of this work strongly suggest that coating material of the iron oxide particles may contribute significantly to the rate of iron oxide particle clearance and degradation in rat liver cells.
  •  
9.
  • Briley Saebo, Karen, et al. (författare)
  • Hepatic cellular distribution and degradation of iron oxide nanoparticles following single intravenous injection in rats : implications for magnetic resonance imaging
  • 2004
  • Ingår i: Cell and Tissue Research. - : Springer Science and Business Media LLC. - 0302-766X .- 1432-0878. ; 316:3, s. 315-323
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to determine the cellular distribution and degradation in rat liver following intravenous injection of superparamagnetic iron oxide nanoparticles used for magnetic resonance imaging (NC100150 Injection). Relaxometric and spectrophotometric methods were used to determine the concentration of the iron oxide nanoparticles and their degradation products in isolated rat liver parenchymal, endothelial and Kupffer cell fractions. An isolated cell phantom was also constructed to quantify the effect of the degradation products on the loss of MR signal in terms of decreased transverse relaxation times, T2*. The results of this study show that iron oxide nanoparticles found in the NC100150 Injection were taken up and distributed equally in both liver endothelial and Kupffer cells following a single 5 mg Fe/kg body wt. bolus injection in rats. Whereas endothelial and Kupffer cells exhibited similar rates of uptake and degradation, liver parenchymal cells did not take up the NC100150 Injection iron oxide particles. Light-microscopy methods did, however, indicate an increased iron load, presumably as ferritin/hemosiderin, within the hepatocytes 24 h post injection. The study also confirmed that compartmentalisation of ferritin/hemosiderin may cause a significant decrease in the MRI signal intensity of the liver. In conclusion, the combined results of this study imply that the prolonged presence of breakdown product in the liver may cause a prolonged imaging effect (in terms of signal loss) for a time period that significantly exceeds the half-life of NC100150 Injection iron oxide nanoparticles in liver.
  •  
10.
  • Briley Saebo, Karen, et al. (författare)
  • Long-term imaging effects in rat liver after a single injection of an iron oxide nanoparticle based MR contrast agent
  • 2004
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 20:4, s. 622-631
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To investigate the duration of liver R2* enhancement and pharmacokinetics following administration of an iron oxide nanoparticle in a rat model.MATERIALS AND METHODS: Rats were injected with 0, 1, 2, or 5 mg Fe/kg of NC100150 Injection, and quantitative in vivo 1/T2* liver measurements were obtained between 1 and 133 days after injection. The concentration of NC100150 Injection was determined by relaxometry methods in ex vivo rat liver homogenate.RESULTS: At all dose levels, 1/T2* remained greater than control values up to 63 days after injection. In the highest dose group, 1/T2* was above control levels during the entire 133 day time-course investigated. There were no quantifiable amounts of NC100150 Injection present 63 days after injection in any of the dose groups. The half-life of NC100150 Injection in rat liver was dose dependent. For the lowest dose group, the degradation of the particles could be defined by a mono-exponential function with a half-life of eight days. For the 2 and 5 mg Fe/kg dose groups, the degradation was bi-exponential with a fast initial decay of seven to eight days followed by a slow terminal decay of 43-46 days.CONCLUSION: NC100150 Injection exhibits prolonged 1/T2* enhancement in rat liver. The liver enhancement persisted at time points when the concentration of iron oxide particles present in the liver was below method detection limits. The prolonged 1/T2* enhancement is likely a result of the particle breakdown products and the induction of ferritin and hemosiderin with increasing iron cores/loading factors.
  •  
11.
  •  
12.
  • Gonzalez-Ortiz, Fernando, 1990, et al. (författare)
  • Plasma brain-derived tau is an amyloid-associated neurodegeneration biomarker in Alzheimer's disease.
  • 2024
  • Ingår i: Nature communications. - 2041-1723. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Staging amyloid-beta (Aβ) pathophysiology according to the intensity of neurodegeneration could identify individuals at risk for cognitive decline in Alzheimer's disease (AD). In blood, phosphorylated tau (p-tau) associates with Aβ pathophysiology but an AD-type neurodegeneration biomarker has been lacking. In this multicenter study (n=1076), we show that brain-derived tau (BD-tau) in blood increases according to concomitant Aβ ("A") and neurodegeneration ("N") abnormalities (determined using cerebrospinal fluid biomarkers); We used blood-based A/N biomarkers to profile the participants in this study; individuals with blood-based p-tau+/BD-tau+ profiles had the fastest cognitive decline and atrophy rates, irrespective of the baseline cognitive status. Furthermore, BD-tau showed no or much weaker correlations with age, renal function, other comorbidities/risk factors and self-identified race/ethnicity, compared with other blood biomarkers. Here we show that blood-based BD-tau is a biomarker for identifying Aβ-positive individuals at risk of short-term cognitive decline and atrophy, with implications for clinical trials and implementation of anti-Aβ therapies.
  •  
13.
  •  
14.
  • Johansson, Lars, et al. (författare)
  • Acute cardiac transplant rejection : detection and grading with MR imaging with a blood pool contrast agent - experimental study in the rat
  • 2002
  • Ingår i: Radiology. - : Radiological Society of North America (RSNA). - 0033-8419 .- 1527-1315. ; 225:1, s. 97-103
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To investigate the possibility of detecting cardiac transplant rejection and determining its degree of severity with magnetic resonance (MR) imaging with a blood pool contrast agent. MATERIALS AND METHODS: Rat allogeneic (PVG to Wistar/Kyoto, n = 9) and syngeneic (Wistar/Kyoto to Wistar/Kyoto, n = 6) heterotopic heart transplantations were performed. On the 2nd and 6th postoperative days, an ultrasmall superparamagnetic iron oxide, or USPIO, contrast agent was injected intravenously at a dose of 2 mg of iron per kilogram of body weight. The injection was followed by three-dimensional T1-weighted MR imaging of the heart grafts with an imaging time of approximately 2 minutes for each image for 44 minutes. The signal intensity (SI) was measured in the myocardium over time, and the relative enhancement was calculated. After the 6th day, the rats were sacrificed, and the morphology of the transplanted hearts was assessed histologically. The CIs for the difference of the means on day 2 and day 6 were calculated by using a bootstrap technique, and the correlation between the relative SI change and the histologically determined degree of rejection were calculated with the Spearman rank order correlation coefficient. RESULTS: On day 6, a statistically significant difference between the groups was found at 4 minutes after injection of the contrast agent and increased with increasing time after injection. The mean percentage change in SI at the last time point for the allogeneic group on day 2 was -8.7% (SD, 8.5) and for the syngeneic group was -6.6% (SD, 6.0). On day 6, the allogeneic group had a relative SI change of 17.7% (SD, 8.7), whereas the syngeneic group had a change of -7.4% (SD, 2.6). There was a significant difference between only the two groups on day 6 (P <.001). Furthermore, in the allogeneic group the histologically determined degree of rejection correlated positively with the relative SI enhancement (r = 0.89, P <.005). CONCLUSION: Acutely rejecting heart transplants can be distinguished from nonrejecting ones in an animal model with MR imaging and a blood pool contrast agent. In addition, the relative SI enhancement reflects the histologically determined degree of rejection.
  •  
15.
  •  
16.
  • Jonsson, Ove, 1966-, et al. (författare)
  • Minimal Safe Arterial Blood Flow During Selective Antegrade Cerebral Perfusion at 20° Centigrade
  • 2011
  • Ingår i: Annals of Thoracic Surgery. - : Elsevier BV. - 0003-4975 .- 1552-6259. ; 91:4, s. 1198-1205
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundSelective antegrade cerebral perfusion (SACP) enables surgery on the aortic arch, where cerebral ischemia may cause neurologic sequels. This study aims to identify the minimum arterial flow level to maintain adequate cerebral perfusion during SACP in deep hypothermia in the pig.MethodsTwo groups of pigs were subjected to SACP at 20°C α-stat. In group 1 (n = 6), flow was stepwise adjusted from 8-6-4-2-8 mL · kg−1 · min−1 and in group 2 (n = 5), flow was kept constant at 6 mL · kg−1 · min−1. Magnetic resonance imaging and spectroscopy were performed at each flow level together with hemodynamic monitoring and blood gas analysis. The biochemical marker of cerebral damage protein S100β was measured in peripheral blood.ResultsDecreased mixed venous oxygen saturation and increased lactate in magnetic resonance spectroscopy was seen as a sign of anaerobic metabolism below 6 mL · kg−1 · min−1. No ischemic damage was seen on diffusion-weighted imaging, but the concentrations of S100β were significantly elevated in group 1 compared with group 2 at the end of the experiment (p < 0.05). Perfusion-weighted imaging showed coherence between flow setting and cerebral perfusion, increase of blood volume across time, and regional differences in perfusion during SACP.ConclusionsThe findings suggest an ischemic threshold close to 6 mL · kg−1 · min−1 in the present model. Regional differences in perfusion during SACP may be of pathogenic importance to focal cerebral ischemia.
  •  
17.
  • Kaiser, Antonia, et al. (författare)
  • A Randomized Controlled Trial on the Effects of a 12-Week High- vs. Low-Intensity Exercise Intervention on Hippocampal Structure and Function in Healthy, Young Adults
  • 2022
  • Ingår i: Frontiers in Psychiatry. - : Frontiers Media SA. - 1664-0640. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • Physical exercise affects hippocampal structure and function, but the underlying neural mechanisms and the effects of exercise intensity remain incompletely understood. Therefore, we undertook a comprehensive, multi-modal 3T and 7T MRI randomized controlled trial (Netherlands Trial Register - NL5847) in which we randomized 52 young, non-athletic volunteers to a 12-week low- or high-intensity exercise program. Using state-of-the-art methods, we investigated changes in hippocampal volume, as well as changes in vasculature, neuro-metabolites, and peripheral growth factors as potential underpinnings. Cardiorespiratory fitness improved over time (p < 0.001), but no interaction with exercise intensity was found (p = 0.48). Accordingly, we did not observe significant interactions between exercise condition and time on MRI measures (all p > 0.06). However, we found a significant decrease in right hippocampal volume (p < 0.01), an increase in left hippocampal glutathione (p < 0.01), and a decrease of left hippocampal cerebral blood volume (p = 0.01) over time, regardless of exercise condition. Additional exploratory analyses showed that changes in brain-derived neurotrophic factor (p = 0.01), insulin-like growth-factor (p = 0.03), and dorsal anterior cingulate cortex N-acetyl-aspartate levels (p = 0.01) were positively associated with cardiorespiratory fitness changes. Furthermore, a trend toward a positive association of fitness and gray-matter cerebral blood flow (p = 0.06) was found. Our results do not provide evidence for differential effects between high-intensity (aerobic) and low-intensity (toning) exercise on hippocampal structure and function in young adults. However, we show small but significant effects of exercise on hippocampal volume, neurometabolism and vasculature across exercise conditions. Moreover, our exploratory results suggest that exercise might not specifically only benefit hippocampal structure and function, but rather has a more widespread effect. These findings suggest that, in agreement with previous MRI studies demonstrating moderate to strong effects in elderly and diseased populations, but none to only mild effects in young healthy cohorts, the benefits of exercise on the studied brain measures may be age-dependent and restorative rather than stimulatory. Our study highlights the importance of a multi-modal, whole-brain approach to assess macroscopic and microscopic changes underlying exercise-induced brain changes, to better understand the role of exercise as a potential non-pharmacological intervention.
  •  
18.
  • MacIntosh, Bradley J., et al. (författare)
  • Radiological features of brain hemorrhage through automated segmentation from computed tomography in stroke and traumatic brain injury
  • 2023
  • Ingår i: Frontiers in Neurology. - 1664-2295. ; 14
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Radiological assessment is necessary to diagnose spontaneous intracerebral hemorrhage (ICH) and traumatic brain injury intracranial hemorrhage (TBI-bleed). Artificial intelligence (AI) deep learning tools provide a means for decision support. This study evaluates the hemorrhage segmentations produced from three-dimensional deep learning AI model that was developed using non-contrast computed tomography (CT) imaging data external to the current study. Methods: Non-contrast CT imaging data from 1263 patients were accessed across seven data sources (referred to as sites) in Norway and Sweden. Patients were included based on ICH, TBI-bleed, or mild TBI diagnosis. Initial non-contrast CT images were available for all participants. Hemorrhage location frequency maps were generated. The number of estimated haematoma clusters was correlated with the total haematoma volume. Ground truth expert annotations were available for one ICH site; hence, a comparison was made with the estimated haematoma volumes. Segmentation volume estimates were used in a receiver operator characteristics (ROC) analysis for all samples (i.e., bleed detected) and then specifically for one site with few TBI-bleed cases. Results: The hemorrhage frequency maps showed spatial patterns of estimated lesions consistent with ICH or TBI-bleed presentations. There was a positive correlation between the estimated number of clusters and total haematoma volume for each site (correlation range: 0.45–0.74; each p-value < 0.01) and evidence of ICH between-site differences. Relative to hand-drawn annotations for one ICH site, the VIOLA-AI segmentation mask achieved a median Dice Similarity Coefficient of 0.82 (interquartile range: 0.78 and 0.83), resulting in a small overestimate in the haematoma volume by a median of 0.47 mL (interquartile range: 0.04 and 1.75 mL). The bleed detection ROC analysis for the whole sample gave a high area-under-the-curve (AUC) of 0.92 (with sensitivity and specificity of 83.28% and 95.41%); however, when considering only the mild head injury site, the TBI-bleed detection gave an AUC of 0.70. Discussion: An open-source segmentation tool was used to visualize hemorrhage locations across multiple data sources and revealed quantitative hemorrhage site differences. The automated total hemorrhage volume estimate correlated with a per-participant hemorrhage cluster count. ROC results were moderate-to-high. The VIOLA-AI tool had promising results and might be useful for various types of intracranial hemorrhage.
  •  
19.
  • Morell, Arvid, et al. (författare)
  • Influence of blood/tissue differences in contrast agent relaxivity on tracer based MR perfusion measurements
  • 2015
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - : Springer Science and Business Media LLC. - 0968-5243 .- 1352-8661. ; 28:2, s. 135-147
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE:Perfusion assessment by monitoring the transport of a tracer bolus depends critically on conversion of signal intensity into tracer concentration. Two main assumptions are generally applied for this conversion; (1) contrast agent relaxivity is identical in blood and tissue, (2) change in signal intensity depends only on the primary relaxation effect. The purpose of the study was to assess the validity and influence of these assumptions.MATERIALS AND METHODS:Blood and cerebral tissue relaxivities r1, r2, and r2* for gadodiamide were measured in four pigs at 1.5 T. Gadolinium concentration was determined by inductively coupled plasma atomic emission spectroscopy. Influence of the relaxivities, secondary relaxation effects and choice of singular value decomposition (SVD) regularization threshold was studied by simulations.RESULTS:In vivo relaxivities relative to blood concentration [in s-1 mM-1 for blood, gray matter (GM), white matter (WM)] were for r1 (2.614 ± 1.061, 0.010 ± 0.001, 0.004 ± 0.002), r2 (5.088 ± 0.952, 0.091 ± 0.008, 0.059 ± 0.014), and r2* (13.292 ± 3.928, 1.696 ± 0.157, 0.910 ± 0.139). Although substantial, by a nonparametric test for paired samples, the differences were not statistically significant. The GM to WM blood volume ratio was estimated to 2.6 ± 0.9 by r1, 1.6 ± 0.3 by r2, and 1.9 ± 0.2 by r2*. Secondary relaxation was found to reduce the tissue blood flow, as did the SVD regularization threshold.CONCLUSION:Contrast agent relaxivity is not identical in blood and tissue leading to substantial errors. Further errors are introduced by secondary relaxation effects and the SVD regularization.
  •  
20.
  •  
21.
  • Morell, Arvid, 1973-, et al. (författare)
  • Quantitative renal cortical perfusion in human subjects with magnetic resonance imaging using iron-oxide nanoparticles: influence of T1 shortening
  • 2008
  • Ingår i: Acta radiologica (Stockholm, Sweden : 1987). - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 49:8, s. 955-62
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Using conventional contrast agents, the technique of quantitative perfusion by observing the transport of a bolus with magnetic resonance imaging (MRI) is limited to the brain due to extravascular leakage. PURPOSE: To perform quantitative perfusion measurements in humans with an intravascular contrast agent, and to estimate the influence of the T1 relaxivity of the contrast agent on the first-pass response. MATERIAL AND METHODS: Renal cortical perfusion was measured quantitatively in six patients with unilateral renal artery stenosis using a rapid gradient double-echo sequence in combination with an intravenous bolus injection of NC100150 Injection, an intravascular contrast agent based on iron-oxide nanoparticles. The influence of T1 relaxivity was measured by comparing perfusion results based on single- and double-echo data. RESULTS: The mean values of cortical blood flow, cortical blood volume, and mean transit time in the normal kidneys were measured to 339+/-60 ml/min/100 g, 41+/-8 ml/100 g, and 7.3+/-1.0 s, respectively, based on double-echo data. The corresponding results based on single-echo data, which are not compensated for the T1 relaxivity, were 254+/-47 ml/min/100 g, 27+/-3 ml/100 g, and 6+/-1.2 s, respectively. CONCLUSION: The use of a double-echo sequence enabled elimination of confounding T1 effects and consequent systematic underestimation of the perfusion.
  •  
22.
  • Morell, Arvid (författare)
  • Quantitative Tracer Based MRI Perfusion : Potentials and Limitations
  • 2012
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Tracer based MRI perfusion measurements is a clinically useful tool to assess regional distributions of tissue blood flow and volume. The method may be based on any of the three relaxation mechanisms T1, T1 and T2*, the latter denoted DSC-MRI being the most common. The primary aim of this work was to study the feasibility of obtaining quantitative estimates using these methods.1) Feasibility of DSC-MRI for kidneys using an iron oxide based contrast agent and the influence of secondary relaxation effects on the results, part of a clinical phase II trial: The method proved feasible and the underestimation induced by secondary relaxation can be corrected for by using a double echo sequence.2) Influence of blood flow rate on risk factors for developing cerebral ischemia during cardio pulmonary bypass, measurements in pig with gadolinium based DSC-MRI: The results indicated an ischemic threshold level at a blood flow rate of approximately 6 ml/kg/min.3) The ability of gadolinium based DSC-MRI to detect changes in global blood flow, experimental measurements in pig and numerical simulations: The results support that DSC-MRI can discriminate between global flow levels in the same subject given that all other parameters are kept constant. The results also indicate that calculated perfusion values are highly sensitive to the arterial deconvolution procedure.4) Influence of differences in blood/tissue relaxivity and secondary relaxation for a gadolinium based contrast agent, measurements in pig and numerical simulations: The blood/tissue relaxivity ratio is not unity and the situation is complicated by secondary relaxation effects. Deconvolution regularization appears to partly counteract the overestimation induced by difference in blood/tissue relaxivity for DSC-MRI.In summary, the fundamental assumption of equal blood and tissue relaxivity is experimentally shown to be invalid and the influence of this discrepancy is substantial. Several factors contribute to measurement errors, a combination of these factors can incidentally lead to additive errors or error cancellation based on a variety of experimental and analysis conditions. Given that the differences in blood/tissue relaxivity cannot readily be accounted for in a clinical setting, absolute perfusion quantification by tracer based MRI remains challenging if not impossible.
  •  
23.
  •  
24.
  • Selnes, Per, et al. (författare)
  • Impaired synaptic function is linked to cognition in Parkinson's disease.
  • 2017
  • Ingår i: Annals of clinical and translational neurology. - : Wiley. - 2328-9503. ; 4:10, s. 700-713
  • Tidskriftsartikel (refereegranskat)abstract
    • Cognitive impairment is frequent in Parkinson's disease, but the underlying mechanisms are insufficiently understood. Because cortical metabolism is reduced in Parkinson's disease and closely associated with cognitive impairment, and CSF amyloid-β species are reduced and correlate with neuropsychological performance in Parkinson's disease, and amyloid-β release to interstitial fluid may be related to synaptic activity; we hypothesize that synapse dysfunction links cortical hypometabolism, reduced CSF amyloid-β, and presynaptic deposits of α-synuclein. We expect a correlation between hypometabolism, CSF amyloid-β, and the synapse related-markers CSF neurogranin and α-synuclein.Thirty patients with mild-to-moderate Parkinson's disease and 26 healthy controls underwent a clinical assessment, lumbar puncture, MRI, 18F-fludeoxyglucose-PET, and a neuropsychological test battery (repeated for the patients after 2 years).All subjects had CSF amyloid-β 1-42 within normal range. In Parkinson's disease, we found strong significant correlations between cortical glucose metabolism, CSF Aβ, α-synuclein, and neurogranin. All PET CSF biomarker-based cortical clusters correlated strongly with cognitive parameters. CSF neurogranin levels were significantly lower in mild-to-moderate Parkinson's disease compared to controls, correlated with amyloid-β and α-synuclein, and with motor stage. There was little change in cognition after 2 years, but the cognitive tests that were significantly different, were also significantly associated with cortical metabolism. No such correlations were found in the control group.CSF Aβ, α-synuclein, and neurogranin concentrations are related to cortical metabolism and cognitive decline. Synaptic dysfunction due to Aβ and α-synuclein dysmetabolism may be central in the evolution of cognitive impairment in Parkinson's disease.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-24 av 24
Typ av publikation
tidskriftsartikel (19)
doktorsavhandling (3)
annan publikation (1)
licentiatavhandling (1)
Typ av innehåll
refereegranskat (19)
övrigt vetenskapligt/konstnärligt (5)
Författare/redaktör
Bjørnerud, Atle (22)
Ahlström, Håkan (15)
Johansson, Lars (6)
Morell, Arvid (4)
Briley Saebo, Karen (4)
Johansson, Lars O. (3)
visa fler...
Thelin, Stefan (3)
Selnes, Per (3)
Lennmyr, Fredrik (3)
Blennow, Kaj, 1958 (2)
Penno, Eva (2)
Zetterberg, Henrik, ... (2)
Aarsland, Dag (2)
Fladby, Tormod (2)
Bjerner, Tomas (2)
Johnsson, Cecilia (2)
Ahlström, Håkan K. (2)
Jonsson, Ove (2)
Hustvedt, Svein Olaf (2)
Pettersson, Jean (1)
Bergquist, Jonas (1)
Harrison, Peter (1)
Wikström, Gerhard (1)
Knutsson, Linda (1)
Lundström, Elin (1)
Suárez-Calvet, Marc (1)
Karikari, Thomas (1)
Wasselius, Johan (1)
Beyer, Mona K (1)
Ahlström, Håkan, Pro ... (1)
Ullberg, Teresa (1)
González-Ortiz, Fern ... (1)
Kirsebom, Bjørn Eivi ... (1)
Nilsson, Johanna, 19 ... (1)
Reneman, Liesbeth (1)
Schrantee, Anouk (1)
Hayden, Kathleen M. (1)
Ericsson, Anders (1)
Briley-Soebo, Karen (1)
Briley-Sæbø, Karen (1)
Bjørnerud, Atle, 196 ... (1)
Wright, Graham A., P ... (1)
Wendland, M F (1)
Higgins, C B (1)
Oksendal, A (1)
Goussin, Yves (1)
Roch, Alan (1)
Muller, Robert N. (1)
Briley Saebo, Karen, ... (1)
Knopp, Michael, Prof ... (1)
visa färre...
Lärosäte
Uppsala universitet (20)
Göteborgs universitet (2)
Lunds universitet (2)
Karolinska Institutet (2)
Språk
Engelska (21)
Odefinierat språk (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (15)
Naturvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy