SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Black Maureen) "

Sökning: WFRF:(Black Maureen)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Boggs, Dorothy, et al. (författare)
  • Rating early child development outcome measurement tools for routine health programme use
  • 2019
  • Ingår i: Archives of Disease in Childhood. - : BMJ Publishing Group Ltd. - 0003-9888 .- 1468-2044. ; 104, s. S22-S33
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Identification of children at risk of developmental delay and/or impairment requires valid measurement of early child development (ECD). We systematically assess ECD measurement tools for accuracy and feasibility for use in routine services in low-income and middle-income countries (LMIC). Methods Building on World Bank and peer-reviewed literature reviews, we identified available ECD measurement tools for children aged 0-3 years used in >= 1 LMIC and matrixed these according to when (child age) and what (ECD domains) they measure at population or individual level. Tools measuring <2 years and covering >= 3 developmental domains, including cognition, were rated for accuracy and feasibility criteria using a rating approach derived from Grading of Recommendations, Assessment, Development and Evaluations. Results 61 tools were initially identified, 8% (n=5) population-level and 92% (n=6) individual-level screening or ability tests. Of these, 27 tools covering >= 3 domains beginning <2 years of age were selected for rating accuracy and feasibility. Recently developed population-level tools (n=2) rated highly overall, particularly in reliability, cultural adaptability, administration time and geographical uptake. Individual-level tool (n=25) ratings were variable, generally highest for reliability and lowest for accessibility, training, clinical relevance and geographical uptake. Conclusions and implications Although multiple measurement tools exist, few are designed for multidomain ECD measurement in young children, especially in LMIC. No available tools rated strongly across all accuracy and feasibility criteria with accessibility, training requirements, clinical relevance and geographical uptake being poor for most tools. Further research is recommended to explore this gap in fit-for-purpose tools to monitor ECD in routine LMIC health services.
  •  
3.
  • Boggs, Dorothy, et al. (författare)
  • Rating early child development outcome measurement tools for routine health programme use.
  • 2019
  • Ingår i: Archives of disease in childhood. - : BMJ. - 1468-2044 .- 0003-9888. ; 104:Suppl 1, s. S22-S33
  • Forskningsöversikt (refereegranskat)abstract
    • Identification of children at risk of developmental delay and/or impairment requires valid measurement of early child development (ECD). We systematically assess ECD measurement tools for accuracy and feasibility for use in routine services in low-income and middle-income countries (LMIC).Building on World Bank and peer-reviewed literature reviews, we identified available ECD measurement tools for children aged 0-3 years used in ≥1 LMIC and matrixed these according to when (child age) and what (ECD domains) they measure at population or individual level. Tools measuring <2 years and covering ≥3 developmental domains, including cognition, were rated for accuracy and feasibility criteria using a rating approach derived from Grading of Recommendations, Assessment, Development and Evaluations.61 tools were initially identified, 8% (n=5) population-level and 92% (n=56) individual-level screening or ability tests. Of these, 27 tools covering ≥3 domains beginning <2 years of age were selected for rating accuracy and feasibility. Recently developed population-level tools (n=2) rated highly overall, particularly in reliability, cultural adaptability, administration time and geographical uptake. Individual-level tool (n=25) ratings were variable, generally highest for reliability and lowest for accessibility, training, clinical relevance and geographical uptake.Although multiple measurement tools exist, few are designed for multidomain ECD measurement in young children, especially in LMIC. No available tools rated strongly across all accuracy and feasibility criteria with accessibility, training requirements, clinical relevance and geographical uptake being poor for most tools. Further research is recommended to explore this gap in fit-for-purpose tools to monitor ECD in routine LMIC health services.
  •  
4.
  • Denton, Christopher P., et al. (författare)
  • Recombinant human anti-transforming growth factor beta 1 antibody therapy in systemic sclerosis - A multicenter, randomized, placebo-controlled phase I/II trial of CAT-192
  • 2007
  • Ingår i: Arthritis and Rheumatism. - : Wiley. - 1529-0131 .- 0004-3591. ; 56:1, s. 323-333
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To evaluate CAT-192, a recombinant human antibody that neutralizes transforming growth factor beta 1 (TGF beta 1), in the treatment of early-stage diffuse cutaneous systemic sclerosis (dcSSc). Methods. Patients with SSc duration of < 18 months were randomly assigned to the placebo group or to 1 of 3 CAT-192 treatment groups: 10 mg/kg, 5 mglkg, 0.5 mg/kg. Infusions were given on day 0 and weeks 6, 12, and 18. The primary objective of this study was to evaluate the safety, tolerability, and pharmacokinetics of CAT-192. Secondary outcomes included the modified Rodnan skin thickness score (MRSS), the Scleroderma Health Assessment Questionnaire, assessment of organ-based disease, serum levels of soluble interleukin-2 receptor, collagen propeptides (N propeptide of type I [PINP] and type III collagen), and tissue levels of messenger RNA for procollagens I and III and for TGF beta 1 and TGF beta 2. Results. Forty-five patients were enrolled. There was significant morbidity and mortality, including I death in the group receiving 0.5 mg/kg of CAT-192 and 3 deaths in the group receiving 5 mg/kg of CAT-192. There were more adverse events and more serious adverse events in patients receiving CAT-192 than in those receiving placebo, although these events were not more frequent in the high-dose treatment group. The MRSS improved in all groups during the study, but there was no evidence of a treatment effect for CAT-192. Improvement in the MRSS correlated with the disease duration (r = -0.54, P = 0.0008). Changes in the PINP level from baseline correlated with changes in the MRSS (r = 0.37, P = 0.027). Conclusion. We report the first evaluation of a systemically administered and repeatedly dosed anti-TGF beta 1 drug. In this pilot study, CAT-192, in doses up to 10 mg/kg, showed no evidence of efficacy. The utility of clinical and biochemical outcome measures and the feasibility of multicenter trials of early dcSSc were confirmed.
  •  
5.
  • Johnston, Jennifer J., et al. (författare)
  • Molecular Analysis Expands the Spectrum of Phenotypes Associated with GLI3 Mutations
  • 2010
  • Ingår i: Human Mutation. - : Hindawi Limited. - 1059-7794. ; 31:10, s. 1142-1154
  • Tidskriftsartikel (refereegranskat)abstract
    • A range of phenotypes including Greig cephalopolysyndactyly and Pallister-Hall syndromes (GCPS, PHS) are caused by pathogenic mutation of the GLI3 gene. To characterize the clinical variability of GLI3 mutations, we present a subset of a cohort of 174 probands referred for GLI3 analysis. Eighty-one probands with typical GCPS or PHS were previously reported, and we report the remaining 93 probands here. This includes 19 probands (12 mutations) who fulfilled clinical criteria for GCPS or PHS, 48 probands (16 mutations) with features of GCPS or PHS but who did not meet the clinical criteria (sub-GCPS and sub-PHS), 21 probands (6 mutations) with features of PHS or GCPS and oral-facial- digital syndrome, and 5 probands (1 mutation) with nonsyndromic polydactyly. These data support previously identified genotype-phenotype correlations and demonstrate a more variable degree of severity than previously recognized. The finding of GLI3 mutations in patients with features of oral-facial-digital syndrome supports the observation that GLI3 interacts with cilia. We conclude that the phenotypic spectrum of GLI3 mutations is broader than that encompassed by the clinical diagnostic criteria, but the genotype-phenotype correlation persists. Individuals with features of either GCPS or PHS should be screened for mutations in GLI3 even if they do not fulfill clinical criteria. Hum Mutat 31:1142-1154, 2010. (C) 2010 Wiley-Liss, Inc.
  •  
6.
  • Merkel, Peter A, et al. (författare)
  • Validity, reliability, and feasibility of durometer measurements of scleroderma skin disease in a multicenter treatment trial
  • 2008
  • Ingår i: Arthritis and Rheumatism. - : Wiley. - 1529-0131 .- 0004-3591. ; 59:5, s. 699-705
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To determine the validity, reliability, and feasibility of durometer measurements of skin hardness as an outcome measure in clinical trials of scleroderma. Methods. Skin hardness was measured during a multicenter treatment trial for scleroderma using handheld digital durometers with a continuous scale. Skin thickness was measured by modified Rodnan skin score (MRSS). Other outcome data collected included the Scleroderma Health Assessment Questionnaire. In a reliability exercise in advance of the trial, 9 investigators examined the same 5 scleroderma patients by MRSS and durometry. Results. Forty-three patients with early diffuse cutaneous systemic sclerosis were studied at 11 international centers (mean age 49 years [range 24-76], median disease duration 6.4 months [range 0.3-23], and median baseline MRSS 22 [range 11-38]). The reliability of durometer measurements was excellent, with high interobserver intraclass correlation coefficients (ICCs) (0.82-0.92), and each result was greater than the corresponding skin site ICCs for MRSS (0.54-0.85). Baseline durometer scores correlated well with MRSS (r = 0.69, P < 0.0001), patient self-assessments of skin disease (r = 0.69, P < 0.0001), and Health Assessment Questionnaire (HAQ) disability scores (r = 0.34, P = 0.03). Change in durometer scores correlated with change in MRSS (r = 0.70, P < 0.0001.), change in patient self-assessments of skin disease (r = 0.52, P = 0.003), and change in HAQ disability scores (r = 0.42, P = 0.017). The effect size was greater for durometry than for MRSS or patient self-assessment. Conclusion. Durometer measurements of skin hardness in patients with scleroderma are reliable, simple, accurate, demonstrate good sensitivity to change compared with traditional skin scoring, and reflect patients' self-assessments of their disease. Durometer measurements are valid, objective, and scalable, and should be considered for use as a complementary outcome measure to skin scoring in clinical trials of scleroderma.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy