SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Boylan Geraldine B.) "

Sökning: WFRF:(Boylan Geraldine B.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Pressler, Ronit M., et al. (författare)
  • Bumetanide for the treatment of seizures in newborn babies with hypoxic ischaemic encephalopathy (NEMO) : an open-label, dose finding, and feasibility phase 1/2 trial
  • 2015
  • Ingår i: Lancet Neurology. - 1474-4422 .- 1474-4465. ; 14:5, s. 469-477
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Predinical data suggest that the loop-diuretic bumetanide might be an effective treatment for neonatal seizures. We aimed to assess dose and feasibility of intravenous bumetanide as an add-on to phenobarbital for treatment of neonatal seizures. Methods In this open-label, dose finding, and feasibility phase 1/2 trial, we recruited full-term infants younger than 48 h who had hypoxic ischaemic encephalopathy and electrographic seizures not responding to a loading-dose of phenobarbital from eight neonatal intensive care units across Europe. Newborn babies were allocated to receive an additional dose of phenobarbital and one of four bumetanide dose levels by use of a bivariate Bayesian sequential dose-escalation design to assess safety and efficacy. We assessed adverse events, pharmacokinetics, and seizure burden during 48 h continuous electroencephalogram (EEG) monitoring. The primary efficacy endpoint was a reduction in electrographic seizure burden of more than 80% without the need for rescue antiepileptic drugs in more than 50% of infants. The trial is registered with ClinicalTrials.gov, number NCT01434225. Findings Between Sept 1, 2011, and Sept 28, 2013, we screened 30 infants who had electrographic seizures due to hypoxic ischaemic encephalopathy. 14 of these infants (10 boys) were included in the study (dose allocation: 0.05 mg/kg, n=4; 0.1 mg/kg, n=3; 0. 2 mg/kg, n=6; 0.3 mg/kg, n=1). All babies received at least one dose of bumetanide with the second dose of phenobarbital; three were withdrawn for reasons unrelated to bumetanide, and one because of dehydration. All but one infant also received aminoglycosides. Five infants met EEG criteria for seizure reduction (one on 0.05 mg/kg, one on 0.1 mg/kg and three on 0.2 mg/kg), and only two did not need rescue antiepileptic drugs (ie, met rescue criteria; one on 0.05 mg/kg and one on 0.3 mg/kg). We recorded no short-term dose-limiting toxic effects, but three of 11 surviving infants had hearing impairment confirmed on auditory testing between 17 and 108 days of age. The most common non-serious adverse reactions were moderate dehydration in one, mild hypotension in seven, and mild to moderate electrolyte disturbances in 12 infants. The trial was stopped early because of serious adverse reactions and limited evidence for seizure reduction. Interpretation Our findings suggest that bumetanide as an add-on to phenobarbital does not improve seizure control in newborn infants who have hypoxic ischaemic encephalopathy and might increase the risk of hearing loss, highlighting the risks associated with the off-label use of drugs in newborn infants before safety assessment in controlled trials.
  •  
2.
  • Stevenson, Nathan J., et al. (författare)
  • Interobserver agreement for neonatal seizure detection using multichannel EEG
  • 2015
  • Ingår i: Annals of Clinical and Translational Neurology. - : Wiley. - 2328-9503. ; 2:11, s. 1002-1011
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To determine the interobserver agreement (IOA) of neonatal seizure detection using the gold standard of conventional, multichannel EEG. Methods: A cohort of full-term neonates at risk of acute encephalopathy was included in this prospective study. The EEG recordings of these neonates were independently reviewed for seizures by three international experts. The IOA was estimated using statistical measures including Fleiss' kappa and percentage agreement assessed over seizure events (event basis) and seizure duration (temporal basis). Results: A total of 4066 h of EEG recordings from 70 neonates were reviewed with an average of 2555 seizures detected. The IOA was high with temporal assessment resulting in a kappa of 0.827 (95% CI: 0.769-0.865; n = 70). The median agreement was 83.0% (interquartile range [IQR]: 76.6-89.5%; n = 33) for seizure and 99.7% (IQR: 98.9-99.8%; n = 70) for non-seizure EEG. Analysis of events showed a median agreement of 83.0% (IQR: 72.9-86.6%; n = 33) for seizures with 0.018 disagreements per hour (IQR: 0.000-0.090 per hour; n = 70). Observers were more likely to disagree when a seizure was less than 30 sec. Overall, 33 neonates were diagnosed with seizures and 28 neonates were not, by all three observers. Of the remaining nine neonates with contradictory EEG detections, seven presented with low total seizure burden. Interpretation: The IOA is high among experts for the detection of neonatal seizures using conventional, multichannel EEG. Agreement is reduced when seizures are rare or have short duration. These findings support EEG-based decision making in the neonatal intensive care unit, inform EEG interpretation guidelines, and provide benchmarks for seizure detection algorithms.
  •  
3.
  • Stevenson, Nathan J., et al. (författare)
  • Treatment Trials for Neonatal Seizures : The Effect of Design on Sample Size
  • 2016
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 11:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (T-d) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7-40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 ( IQR: 1.9-11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7-2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4-3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size.
  •  
4.
  • Toorell, Hanna, et al. (författare)
  • Neuro-Specific and Immuno-Inflammatory Biomarkers in Umbilical Cord Blood in Neonatal Hypoxic-Ischemic Encephalopathy.
  • 2024
  • Ingår i: Neonatology. - 1661-7819. ; 121:1, s. 25-33
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the study was to evaluate neuronal injury and immuno-inflammatory biomarkers in umbilical cord blood (UCB) at birth, in cases with perinatal asphyxia with or without hypoxic-ischemic encephalopathy (HIE), compared with healthy controls and to assess their ability to predict HIE.In this case-control study, term infants with perinatal asphyxia were recruited at birth. UCB was stored at delivery for batch analysis. HIE was diagnosed by clinical Sarnat staging at 24 h. Glial fibrillary acidic protein (GFAP), the neuronal biomarkers tau and neurofilament light protein (NFL), and a panel of cytokines were analyzed in a total of 150 term neonates: 50 with HIE, 50 with asphyxia without HIE (PA), and 50 controls. GFAP, tau, and NFL concentrations were measured using ultrasensitive single-molecule array (Simoa) assays, and a cytokine screening panel was applied to analyze the immuno-inflammatory and infectious markers.GFAP, tau, NFL, and several cytokines were significantly higher in newborns with moderate and severe HIE compared to a control group and provided moderate prediction of HIE II/III (AUC: 0.681-0.827). Furthermore, the levels of GFAP, tau, interleukin-6 (IL-6), and interleukin-8 (IL-8) were higher in HIE II/III cases compared with cases with PA/HIE I. IL-6 was also higher in HIE II/III compared with HIE I cases.Biomarkers of brain injury and inflammation were increased in umbilical blood in cases with asphyxia. Several biomarkers were higher in HIE II/III versus those with no HIE or HIE I, suggesting that they could assist in the prediction of HIE II/III.
  •  
5.
  • Vanhatalo, Sampsa, et al. (författare)
  • Why monitor the neonatal brain-that is the important question
  • 2023
  • Ingår i: Pediatric Research. - : Springer Nature. - 0031-3998 .- 1530-0447. ; 93:1, s. 19-21
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • A key goal of neonatal neurocritical care is improved outcomes, and brain monitoring plays an essential role. The recent NEST trial(1) reported no outcome benefits using aEEG monitoring compared to clinical seizure identification among neonates treated for seizures. However, the study failed to prove the effects of monitoring on seizure treatment in the first place.
  •  
6.
  • Weeke, Lauren C., et al. (författare)
  • Lidocaine response rate in aEEG-confirmed neonatal seizures : Retrospective study of 413 full-term and preterm infants
  • 2016
  • Ingår i: Epilepsia. - : Wiley. - 0013-9580 .- 1528-1167. ; 57:2, s. 233-242
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveTo investigate the seizure response rate to lidocaine in a large cohort of infants who received lidocaine as second- or third-line antiepileptic drug (AED) for neonatal seizures. MethodsFull-term (n = 319) and preterm (n = 94) infants, who received lidocaine for neonatal seizures confirmed on amplitude-integrated EEG (aEEG), were studied retrospectively (January 1992-December 2012). Based on aEEG findings, the response was defined as good (>4 h no seizures, no need for rescue medication); intermediate (0-2 h no seizures, but rescue medication needed after 2-4 h); or no clear response (rescue medication needed <2 h). ResultsLidocaine had a good or intermediate effect in 71.4%. The response rate was significantly lower in preterm (55.3%) than in full-term infants (76.1%, p < 0.001). In full-term infants the response to lidocaine was significantly better than midazolam as second-line AED (21.4% vs. 12.7%, p = 0.049), and there was a trend for a higher response rate as third-line AED (67.6% vs. 57%, p = 0.086). Both lidocaine and midazolam had a higher response rate as third-line AED than as second-line AED (p < 0.001). Factors associated with a good response to lidocaine were the following: higher gestational age, longer time between start of first seizure and administration of lidocaine, lidocaine as third-line AED, use of new lidocaine regimens, diagnosis of stroke, use of digital aEEG, and hypothermia. Multivariable analysis of seizure response to lidocaine included lidocaine as second- or third-line AED and seizure etiology. SignificanceSeizure response to lidocaine was seen in similar to 70%. The response rate was influenced by gestational age, underlying etiology, and timing of administration. Lidocaine had a significantly higher response rate than midazolam as second-line AED, and there was a trend for a higher response rate as third-line AED. Both lidocaine and midazolam had a higher response rate as third-line compared to second-line AED, which could be due to a pharmacologic synergistic mechanism between the two drugs.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6
Typ av publikation
tidskriftsartikel (6)
Typ av innehåll
refereegranskat (5)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Boylan, Geraldine B. (6)
Vanhatalo, Sampsa (4)
Hellström-Westas, Le ... (3)
Pressler, Ronit M. (3)
de Vries, Linda S (3)
Stevenson, Nathan J. (3)
visa fler...
Hallberg, Boubou (2)
Toet, Mona C. (2)
Murray, Deirdre (2)
Blennow, Kaj, 1958 (1)
Zetterberg, Henrik, ... (1)
Rosén, Ingmar (1)
Hagberg, Henrik, 195 ... (1)
Jullien, Vincent (1)
Carlsson, Ylva, 1975 (1)
Hellström-Westas, Le ... (1)
Blennow, Mats (1)
Hartmann, Hans (1)
Cross, J. Helen (1)
Groenendaal, Floris (1)
Murphy, Brendan (1)
Brigo, Francesco (1)
Cilio, M. Roberta (1)
Abend, Nicholas S. (1)
Moshe, Solomon L. (1)
Zohar, Sarah (1)
Marlow, Neil (1)
Wilmshurst, Jo M. (1)
Chiron, Catherine (1)
Livingstone, Vicki (1)
Mangum, Barry (1)
Pons, Gerard (1)
Rennie, Janet (1)
Swarte, Renate (1)
Auvin, Stephane (1)
Inder, Terrie E. (1)
Clancy, Robert R. (1)
Rennie, Janet M. (1)
Toorell, Hanna (1)
O'Riordian, Mairead ... (1)
Walsh, Brian Henry (1)
O'Sullivan, Marc Pau ... (1)
van Rooij, Linda G. ... (1)
Hahn, Cecil D. (1)
Nunes, Magda L. (1)
Shellhaas, Renee A. (1)
Vinayan, Kollencheri ... (1)
Yozawitz, Elissa (1)
Weeke, Lauren C. (1)
van den Broek, Marce ... (1)
visa färre...
Lärosäte
Uppsala universitet (4)
Karolinska Institutet (2)
Göteborgs universitet (1)
Lunds universitet (1)
Språk
Engelska (6)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy