SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bramlage Peter) "

Sökning: WFRF:(Bramlage Peter)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Droppa, Michal, et al. (författare)
  • Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis
  • 2020
  • Ingår i: Heart and Vessels. - : Springer. - 0910-8327 .- 1615-2573. ; 35, s. 1735-1745
  • Tidskriftsartikel (refereegranskat)abstract
    • Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%;p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes. Clinical Trial: NCT03497611.
  •  
2.
  • Nielsen, Niels Erik, et al. (författare)
  • Minimizing the risk for left ventricular rupture during transcatheter aortic valve implantation by reducing the presence of stiff guidewires in the ventricle
  • 2019
  • Ingår i: Interactive Cardiovascular and Thoracic Surgery. - : OXFORD UNIV PRESS. - 1569-9293 .- 1569-9285. ; 29:3, s. 365-370
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: The presence of a stiff guidewire in the apex of the left ventricle (LV) is a known risk factor for LV perforation. Our goal was to minimize the risk of LV rupture during transcatheter aortic valve implantation (TAVI) by omitting the interaction between the stiff guidewire and the LV apex using a modified procedure. METHODS: A TAVI protocol designed to allow minimal interaction between a stiff guidewire and the LV was developed in Linkoping University Hospital in Sweden. A total of 316 patients were treated exclusively by this approach between March 2014 and May 2018. RESULTS: All procedures were completed successfully. There were no cases (0%) of ventricular perforation. Only 1 patient (0.3%) had a pericardial effusion, and it was due to annulus rupture. There was 1 case of acute kidney injury (0.3%). Five patients (1.6%) required a new permanent pacemaker. Stroke occurred in 3 patients (0.9%). No patient had valve embolization. Vascular complications were experienced by 6 patients (1.9%). A mild paravalvular leak occurred in 27 (8.5%) patients. At 30 days post-TAVI, 6 patients (2%) had died. The mortality rate at 1 year was 8.6% (n = 20/232). CONCLUSIONS: Our series shows that TAVI without the prolonged use of a stiff guidewire in the LV apex is feasible. The risk of LV perforation is eliminated by this approach, and other procedural complications are limited.
  •  
3.
  • Rudolph, Tanja, et al. (författare)
  • Modifiable risk factors for permanent pacemaker after transcatheter aortic valve implantation: CONDUCT registry
  • 2023
  • Ingår i: Open heart. - : BMJ PUBLISHING GROUP. - 2053-3624. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective The onset of new conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is still a relevant adverse event. The main objective of this registry was to identify modifiable procedural risk factors for an improved outcome (lower rate of PPI) after TAVI in patients at high risk of PPI.Methods Patients from four European centres receiving a balloon-expandable TAVI (Edwards SAPIEN 3/3 Ultra) and considered at high risk of PPI (pre-existing conduction disturbance, heavily calcified left ventricular outflow tract or short membranous septum) were prospectively enrolled into registry.Results A total of 300 patients were included: 42 (14.0%) required PPI after TAVI and 258 (86.0%) did not. Patients with PPI had a longer intensive care unit plus intermediate care stay (65.7 vs 16.3 hours, p < 0.001), general ward care stay (6.9 vs 5.3 days, p=0.004) and later discharge (8.6 vs 5.0 days, p < 0.001). Of the baseline variables, only pre-existing right bundle branch block at baseline (OR 6.8, 95% CI 2.5 to 18.1) was significantly associated with PPI in the multivariable analysis. Among procedure-related variables, oversizing had the highest impact on the rate of PPI: higher than manufacturer-recommended sizing, mean area oversizing as well as the use of the 29 mm valve (OR 3.4, 95% CI 1.4 to 8.5, p=0.008) all were significantly associated with PPI. Rates were higher with the SAPIEN 3 (16.1%) vs SAPIEN 3 Ultra (8.5%), although not statistically significant but potentially associated with valve sizing. Implantation depth and postdelivery balloon dilatation also tended to affect PPI rates but without a statistical significance.Conclusion Valve oversizing is a strong procedure-related risk factor for PPI following TAVI. The clinical impact of the valve type (SAPIEN 3), implantation depth, and postdelivery balloon dilatation did not reach significance and may reflect already refined procedures in the participating centres, giving attention to these avoidable risk factors.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy