SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brodén Cyrus) "

Sökning: WFRF:(Brodén Cyrus)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brodén, Cyrus, et al. (författare)
  • Accuracy and precision of a CT method for assessing migration in shoulder arthroplasty : an experimental study
  • 2019
  • Ingår i: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Radiostereometric analysis (RSA) is the gold standard to measure early implant migration which is a predictive factor for implant survival. Purpose: To validate an alternative computed tomography (CT) technique to measure implant migration in shoulder arthroplasty. Material and Methods: A cadaver proximal humerus and a scapula, which had tantalum beads incorporated within them, were prepared to accept a short-stemmed humeral component and a two-pegged glenoid component of a commercial total shoulder arthroplasty (TSA) system. A five degree of freedom micrometer and goniometer equipped rig was used to translate and rotate the implant components relative to the respective bone to predetermined positions. Double CT examinations were performed for each position and CT motion analysis software (CTMA) was used to assess these movements. The accuracy and precision of the software was estimated using the rig’s micrometers and goniometers as the gold standard. The technique’s effective dose was also assessed. Results: The accuracy was in the range of 0.07–0.23 mm in translation and 0.22–0.71° in rotation. The precision was in the range of 0.08–0.15 mm in translation and 0.23–0.54° in rotation. The mean effective dose for the CT scans was calculated to be 0.27 mSv. Conclusion: In this experimental setting, accuracy, precision, and effective dose of the CTMA technique were found to be comparable to that of RSA. Therefore, we believe clinical studies are warranted to determine if CTMA is a suitable alternative to traditional RSA for migration measurements in TSA.
  •  
2.
  • Brodén, Cyrus, et al. (författare)
  • Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups : An Experimental Study
  • 2016
  • Ingår i: BioMed Research International. - : Hindawi Publishing Corporation. - 2314-6133 .- 2314-6141.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty.Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated.Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv.Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting.
  •  
3.
  • Broden, Cyrus, et al. (författare)
  • CT-based micromotion analysis method can assess early implant migration and development of radiolucent lines in cemented glenoid components : a clinical feasibility study
  • 2022
  • Ingår i: Acta Orthopaedica. - : Medical Journal Sweden AB. - 1745-3674 .- 1745-3682. ; 93, s. 277-283
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - CT micromotion analysis (CTMA) has been considered as an alternative to radiostereometry (RSA) for assessing early implant migration of orthopedic implants. We investigated the feasibility of CTMA to assess early migration and the progression of radiolucent lines in shoulder arthroplasties over 24 months using sequential low-dose CT scans. Patients and methods - 7 patients were included and underwent 9 primary total shoulder arthroplasties. We made CT scans preoperatively, within 1 week postoperatively, and after 3, 6, 12, and 24 months. At each follow-up, postoperative glenoid migration and any development of radiolucent lines were assessed. Clinical outcomes were recorded at all time points except within 1 week postoperatively. Results - For the glenoid component, the median translation and median rotation were 0.00-0.10 mm and -1.53 degrees to 1.05 degrees at 24 months. Radiolucent lines could be observed around all glenoid components. The radiolucent lines developed from the periphery to the center of the implant for 6 glenoid components during follow-up. The Constant Score improved from a mean of 30 (21-51) preoperatively to 69 (41-88) at 24 months. Interpretation - CTMA can be used to identify early migration and the development of radiolucent lines over time in glenoid components. Clinical trials with a larger sample size and longer follow-up are needed to establish the relationship between migration, radiolucent lines, loosening, and clinical outcome.
  •  
4.
  • Brodén, Cyrus, et al. (författare)
  • High risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem : an observational, prospective cohort study on 1,403 hips with 47 fractures after mean follow-up time of 4 years
  • 2015
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 86:2, s. 169-174
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Postoperative periprosthetic femoral fracture (PPF) after hip arthroplasty is associated with considerable morbidity and mortality. We assessed the incidence and characteristics of periprosthetic fractures in a consecutive cohort of elderly patients treated with a cemented, collarless, polished and tapered femoral stem (CPT). Patients and methods - In this single-center prospective cohort study, we included 1,403 hips in 1,357 patients (mean age 82 (range 52-102) years, 72% women) with primary osteoarthritis (OA) or a femoral neck fracture (FNF) as indication for surgery (367 hips and 1,036 hips, respectively). 64% of patients were ASA class 3 or 4. Hip-related complications and need for repeat surgery were assessed at a mean follow-up time of 4 (1-7) years. A Cox regression analysis was used to evaluate risk factors associated with PPF. Results - 47 hips (3.3%) sustained a periprosthetic fracture at median 7 (2-79) months postoperatively; 41 were comminute Vancouver B2 or complex C-type fractures. The fracture rate was 3.8% for FNF patients and 2.2% for OA patients (hazard ratio (HR) = 4; 95% CI: 1.3-12). Patients > 80 years of age also had a higher risk of fracture (HR = 2; 95% CI: 1.1-4.5). Interpretation - We found a high incidence of early PPF associated with the CPT stem in this old and frail patient group. A possible explanation may be that the polished tapered stem acts as a wedge, splitting the femur after a direct hip contusion. Our results should be confirmed in larger, registry-based studies, but we advise caution when using this stem for this particular patient group.
  •  
5.
  • Brodén, Cyrus, et al. (författare)
  • Low-dose CT-based implant motion analysis is a precise tool for early migration measurements of hip cups : a clinical study of 24 patients
  • 2020
  • Ingår i: Acta Orthopaedica. - : Informa UK Limited. - 1745-3674 .- 1745-3682. ; 91:3, s. 260-265
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Early implant migration is known to be a predictive factor of clinical loosening in total hip arthroplasty (THA). Radiostereometric analysis (RSA) is the gold standard used to measure early migration in patients. However, RSA requires costly, specialized imaging equipment and the image process is complex. We determined the precision of an alternative, commercially available, CT method in 3 ongoing clinical THA studies, comprising 3 different cups.Materials and methods - 24 CT double examinations of 24 hip cups were selected consecutively from 3 ongoing prospective studies: 2 primary THA (1 cemented and 1 uncemented) and 1 THA (cemented) revision study. Precision of the CT-based implant motion analysis (CTMA) system was calculated separately for each study, using both the surface anatomy of the pelvis and metal beads placed in the pelvis.Results - For the CTMA analysis using the surface anatomy of the pelvis, the precision ranged between 0.07 and 0.31 mm in translation and 0.20° and 0.39° for rotation, respectively. For the CTMA analysis using beads the precision ranged between 0.08 and 0.20 mm in translation and between 0.20° and 0.43° for rotations. The radiation dose ranged between 0.2 and 2.3 mSv.Interpretation - CTMA achieved a clinically relevant and consistent precision between the 3 different hip cups studied. The use of different hip cup types, different CT scanners, or registration method (beads or surface anatomy) had no discernible effect on precision. Therefore, CTMA without the use of bone markers could potentially be an alternative to RSA to measure early migration.
  •  
6.
  • Mellner, Carl, et al. (författare)
  • The Sernbo score predicts 1-year mortality after displaced femoral neck fractures treated with a hip arthroplasty
  • 2017
  • Ingår i: Acta Orthopaedica. - : Taylor & Francis. - 1745-3674 .- 1745-3682. ; 88:4, s. 402-406
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Displaced femoral neck fractures (FNFs) are associated with high rates of mortality during the first postoperative year. The Sernbo score (based on age, habitat, mobility, and mental state) can be used to stratify patients into groups with different 1-year mortality. We assessed this predictive ability in patients with a displaced FNF treated with a hemiarthroplasty or a total hip arthroplasty. Patients and methods - 292 patients (median age 83 (65-99) years, 68% female) with a displaced FNF were included in this prospective cohort study. To predict 1-year mortality, we used a multivariate logistic regression analysis including comorbidities and perioperative management. A receiver operating characteristic (ROC) analysis was used to evaluate the predictive ability of the Sernbo score, which was subsequently divided in a new manner into a low, intermediate, or high risk of death during the first year. Results - At 1-year follow-up, the overall mortality rate was 24%, and in Sernbo's low-, intermediate-, and high-risk groups it was 5%, 22%, and 51%, respectively. The Sernbo score was the only statistically significant predictor of 1-year mortality: odds ratio for the intermediate-risk group was 4.2 (95% Cl: 1.5-12) and for the high-risk group it was 15 (95% CI: 5-40). The ROC analysis showed a fair predictive ability of the Sernbo score, with an area under the curve (AUC) of 0.79 (95% CI: 0.73-0.83). Using a cutoff of less than 11 points on the score gave a sensitivity of 61% and a specificity of 83%. Interpretation - The Sernbo score identifies patients who are at high risk of dying in the first postoperative year. This scoring system could be used to better tailor perioperative care and treatment in patients with displaced FNF.
  •  
7.
  • Mukka, Sebastian, et al. (författare)
  • Dislocation of bipolar hip hemiarthroplasty through a postero-lateral approach for femoral neck fractures : A cohort study
  • 2015
  • Ingår i: International Orthopaedics. - : Springer Science and Business Media LLC. - 0341-2695 .- 1432-5195. ; 39:7, s. 1277-1282
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose To analyze postoperative global femoral offset (FO), leg length discrepancy (LLD) and Wiberg angle as risk factors for prosthetic dislocation after treatment with bipolar hemiarthoplasty (HA) through a postero-lateral approach for femoral neck fracture (FNF). Methods Three hundred and seventy three patients treated with a cemented bipolar HA through a postero-lateral approach between January 2006 and December 2013 were included in a cohort study with a follow-up time ranging from 6 months to 7 years. Radiographs and all surgical records were reviewed regarding Global FO, LLD and Wiberg angle. We compared stable hips without dislocation to those with either a single dislocation and those with recurrent instability. Results Three hundred and twenty eight hips fulfilled the inclusion criteria and were analyzed in the study. The incidence of prosthetic dislocation was 10.7 % (36/373). The mean time from surgery to first dislocation was 3.9 months (0-47) and 62.5 % had recurrent dislocations. Patients with dislocation had a statistically significantly decreased postoperative global FO (-6.4 mm vs. -2.8 mm, p = 0.04), LLD (-2 vs. 1.5 mm, p = 0.03) and smaller Wiberg angle (40A degrees vs. 46A degrees, p = 0.01) on the operated side compared with the rest of cohort. In comparison to age and sex-matched control groups from the cohort, the difference in the radiographic parameters were significant in patients with recurrent dislocations but not in patients with a single dislocation. Conclusion Patients with recurrent dislocations had a decreased postoperative global FO, shorter leg and shallower acetabulum on the operated side compared with their controls. These factors might decrease the soft-tissue tension around the operated hip and predispose to dislocation.
  •  
8.
  • Rosenberg, Guillermo Sanchez, et al. (författare)
  • ChatGPT-4 generates orthopedic discharge documents faster than humans maintaining comparable quality : a pilot study of 6 cases
  • 2024
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden. - 1745-3674 .- 1745-3682. ; 95, s. 152-156
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose - Large language models like ChatGPT-4 have emerged. They hold the potential to reduce the administrative burden by generating everyday clinical documents, thus allowing the physician to spend more time with the patient. We aimed to assess both the quality and efficiency of discharge documents generated by ChatGPT-4 in comparison with those produced by physicians.Patients and methods - To emulate real -world situations, the health records of 6 fictional orthopedic cases were created. Discharge documents for each case were generated by a junior attending orthopedic surgeon and an advanced orthopedic resident. ChatGPT-4 was then prompted to generate the discharge documents using the same health record information. The quality assessment was performed by an expert panel (n = 15) blinded to the source of the documents. As secondary outcome, the time required to generate the documents was compared, logging the duration of the creation of the discharge documents by the physician and by ChatGPT-4.Results - Overall, both ChatGPT-4 and physiciangenerated notes were comparable in quality. Notably, ChatGPT-4 generated discharge documents 10 times faster than the traditional method. 4 events of hallucinations were found in the ChatGPT-4-generated content, compared with 6 events in the human/physician produced notes.Conclusion - ChatGPT-4 creates orthopedic discharge notes faster than physicians, with comparable quality. This shows it has great potential for making these documents more efficient in orthopedic care. ChatGPT-4 has the potential to significantly reduce the administrative burden on healthcare professionals.
  •  
9.
  • Sandberg, Olof H., et al. (författare)
  • Computed tomography-based radiostereometric analysis in orthopedic research: practical guidelines
  • 2023
  • Ingår i: ACTA ORTHOPAEDICA. - : Medical Journals Sweden. - 1745-3674 .- 1745-3682. ; 94, s. 373-378
  • Tidskriftsartikel (refereegranskat)abstract
    • - Early implant migration is an indicator of the long-term survival/failure of implants. CT-based radio-stereometric analysis (CT-RSA) is a precise method for mea-suring and visualizing implant migration in vivo using image processing of CT scans. This makes the method widely applicable to orthopedic researcher. Since its development in the early 2000s, CT-RSA has benefited from breakthroughs in CT and computing technol-ogy. These advancements have allowed for the acquisition of images with higher resolution at a much lower radiation dose. As a result, the measurement precision of CT-RSA is now comparable to that of the current gold standard technol-ogy while still compatible with most ethical considerations regarding radiation exposure. In this review we present bests practices for the successful execution of CT-RSA research projects. These practices are based on experience from projects on the hip, knee, shoulder, lower back, cervical spine, foot, pelvis, and wrist.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy