SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Canet F. J. Egea) "

Sökning: WFRF:(Canet F. J. Egea)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Clement, E., et al. (författare)
  • Conceptual design of the AGATA 1 π array at GANIL
  • 2017
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 855, s. 1-12
  • Tidskriftsartikel (refereegranskat)abstract
    • The Advanced GAmma Tracking Array (AGATA) has been installed at the GANIL facility, Caen-France. This setup exploits the stable and radioactive heavy-ions beams delivered by the cyclotron accelerator complex of GANIL. Additionally, it benefits from a large palette of ancillary detectors and spectrometers to address in-beam γ-ray spectroscopy of exotic nuclei. The set-up has been designed to couple AGATA with a magnetic spectrometer, charged-particle and neutron detectors, scintillators for the detection of high-energy γ rays and other devices such as a plunger to measure nuclear lifetimes. In this paper, the design and the mechanical characteristics of the set-up are described. Based on simulations, expected performances of the AGATA l π array are presented.
  •  
2.
  • Siciliano, M., et al. (författare)
  • Pairing-quadrupole interplay in the neutron-deficient tin nuclei : First lifetime measurements of low-lying states in Sn-106,Sn-108
  • 2020
  • Ingår i: Physics Letters B. - : ELSEVIER. - 0370-2693 .- 1873-2445. ; 806
  • Tidskriftsartikel (refereegranskat)abstract
    • The lifetimes of the low-lying excited states 2(+) and 4(+) have been directly measured in the neutron-deficient Sn-106,Sn-108 isotopes. The nuclei were populated via a deep-inelastic reaction and the lifetime measurement was performed employing a differential plunger device. The emitted gamma rays were detected by the AGATA array, while the reaction products were uniquely identified by the VAMOS++ magnetic spectrometer. Large-Scale Shell-Model calculations with realistic forces indicate that, independently of the pairing content of the interaction, the quadrupole force is dominant in the B(E2; 2(1)(+) -> 0(g.s)(+)) values and it describes well the experimental pattern for Sn104-114 ; the B(E2;(+)(4) -> 2(1)(+)) values, measured here for the first time, depend critically on a delicate pairing-quadrupole balance, disclosed by the very precise results in Sn-108. 
  •  
3.
  • Jaworski, G., et al. (författare)
  • The New Neutron Multiplicity Filter NEDA and Its First Physics Campaign with AGATA
  • 2019
  • Ingår i: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 50:3, s. 585-590
  • Tidskriftsartikel (refereegranskat)abstract
    • A new neutron multiplicity filter NEDA, after a decade of design, R&D and construction, was employed in its first physics campaign with the AGATA spectrometer. Properties and performance of the array are discussed.
  •  
4.
  • Egea Canet, F. J., et al. (författare)
  • A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1056-1062
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
  •  
5.
  • Egea Canet, F. J., et al. (författare)
  • Digital Front-End Electronics for the Neutron Detector NEDA
  • 2015
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:3, s. 1063-1069
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the design of the NEDA (Neutron Detector Array) electronics, a first attempt to involve the use of digital electronics in large neutron detector arrays. Starting from the front-end modules attached to the PMTs (PhotoMultiplier Tubes) and ending up with the data processing workstations, a comprehensive electronic system capable of dealing with the acquisition and pre-processing of the neutron array is detailed. Among the electronic modules required, we emphasize the front-end analog processing, the digitalization, digital pre-processing and communications firmware, as well as the integration of the GTS (Global Trigger and Synchronization) system, already used successfully in AGATA (Advanced Gamma Tracking Array). The NEDA array will be available for measurements in 2016.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy