SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Chi Xiaoming) "

Sökning: WFRF:(Chi Xiaoming)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Chi, Xiaoming, et al. (författare)
  • Fractal superconducting nanowire single-photon detectors with reduced polarization sensitivity
  • 2018
  • Ingår i: Optics Letters. - : OPTICAL SOC AMER. - 0146-9592 .- 1539-4794. ; 43:20, s. 5017-5020
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate superconducting nanowire single-photon detectors (SNSPDs) based on a fractal design of the nanowires to reduce the polarization sensitivity of detection efficiency. We patterned niobium titanium nitride thin films into Peano curves with a linewidth of 100 nm and integrated the nanowires with optical microcavities to enhance their optical absorption. At a base temperature of 2.6 K, the fractal SNSPD exhibited a polarization-maximum device efficiency of 67% and a polarization-minimum device efficiency of 61% at a wavelength of 1550 nm. Therefore, the polarization sensitivity, defined as their ratio, was 1.1, lower than the polarization sensitivity of the SNSPDs in the meander design. The reduced polarization sensitivity of the detector could be maintained for higher-order spatial modes in multimode optical fibers and could tolerate misalignment between the optical mode and the detector. This fractal design is applicable to both amorphous and polycrystalline materials that are commonly used for making SNSPDs.
  •  
2.
  •  
3.
  • Hu, Xiaolong, et al. (författare)
  • Fractal superconducting nanowire single-photon detectors and their applications in polarimetric imaging
  • 2024
  • Ingår i: Advanced Photon Counting Techniques XVIII. - : SPIE-Intl Soc Optical Eng.
  • Konferensbidrag (refereegranskat)abstract
    • In this paper, we review the research and development of the fractal superconducting nanowire single-photon detectors (SNSPDs), including our demonstrations of high-performance devices and systems with over 80% system detection efficiency, negligibly low residual polarization sensitivity, and low timing jitter. Using the fractal SNSPDs, we demonstrate full-Stokes polarimetric imaging LiDAR.
  •  
4.
  • Hu, Xiaolong, et al. (författare)
  • Superconducting nanowire single-photon detectors at the infrared spectrum range : detection efficiency and timing jitter
  • 2019
  • Ingår i: TERAHERTZ, RF, MILLIMETER, AND SUBMILLIMETER-WAVE TECHNOLOGY AND APPLICATIONS XII. - : SPIE. - 9781510624771
  • Konferensbidrag (refereegranskat)abstract
    • This paper reviews some recent research progress in superconducting nanowire single-photon detectors (SNSPDs) at the infrared spectrum range, with particular emphasis on detection efficiency and timing jitter. For detection efficiency, we present fractal SNSPDs with reduced polarization sensitivity; for timing jitter, we present two mechanisms of device timing jitter - vortex-crossing-induced timing jitter and spatial-inhomogeneity-induced timing jitter.
  •  
5.
  • Hu, Xiaolong, et al. (författare)
  • Timing properties of superconducting nanowire single-photon detectors
  • 2019
  • Ingår i: Quantum Optics and Photon Counting 2019. - : SPIE - International Society for Optical Engineering. - 9781510627215
  • Konferensbidrag (refereegranskat)abstract
    • In this paper, we review theoretical and experimental research progress on timing properties of superconducting nanowire single-photon detectors, including six possible mechanisms that induce timing jitter and experiments towards ultra-low timing jitter.
  •  
6.
  • Waikar, Sushrut S, et al. (författare)
  • Relationship of proximal tubular injury to chronic kidney disease as assessed by urinary kidney injury molecule-1 in five cohort studies
  • 2016
  • Ingår i: Nephrology, Dialysis and Transplantation. - : Oxford University Press (OUP). - 0931-0509 .- 1460-2385. ; 31:9, s. 1460-1470
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The primary biomarkers used to define CKD are serum creatinine and albuminuria. These biomarkers have directed focus on the filtration and barrier functions of the kidney glomerulus even though albuminuria results from tubule dysfunction as well. Given that proximal tubules make up ∼90% of kidney cortical mass, we evaluated whether a sensitive and specific marker of proximal tubule injury, urinary kidney injury molecule-1 (KIM-1), is elevated in individuals with CKD or with risk factors for CKD.METHODS: We measured urinary KIM-1 in participants of five cohort studies from the USA and Sweden. Participants had a wide range of kidney function and were racially and ethnically diverse. Multivariable linear regression models were used to test the association of urinary KIM-1 with demographic, clinical and laboratory values.RESULTS: In pooled, multivariable-adjusted analyses, log-transformed, creatinine-normalized urinary KIM-1 levels were higher in those with lower eGFR {β = -0.03 per 10 mL/min/1.73 m(2) [95% confidence interval (CI) -0.05 to -0.02]} and greater albuminuria [β = 0.16 per unit of log albumin:creatinine ratio (95% CI 0.15-0.17)]. Urinary KIM-1 levels were higher in current smokers, lower in blacks than nonblacks and lower in users versus nonusers of angiotensin-converting enzyme inhibitors and angiotensin receptor blockers.CONCLUSION: Proximal tubule injury appears to be an integral and measurable element of multiple stages of CKD.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy