1.
  • Costa Ferreira, Brigida, 1972- (författare)
  • Biological optimization of angle of incidence and intensity modulation in breast and cervix cancer radiation therapy
  • 2004
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Biological treatment optimization aim at improving radiation therapy by accounting for the radiobiological tumour and normal tissues response properties when optimizing the dose delivery. Generally traditional methods, using only dosimetrical measures, disregard the nonlinear radiation response of different tumours and normal tissues. The accumulated knowledge on tissue response to radiation, in the form of more accurate dose response relations, cell survival models and their associated biological parameters, alongside with the tools for biological treatment plan optimization, has allowed the present investigation on the potential merits of biologically based treatment optimization in radiation therapy.With a more widespread implementation of intensity modulated radiation therapy in the clinic, there is an increasing demand for faster and safer treatment delivery techniques. In this thesis biological treatment plan optimization, using the probability to achieve complication free tumour control as the quantifier for treatment outcome, was applied to radiation therapy of early breast cancer and advanced cervix cancer. It is shown that very conformal dose distributions can generally be produced with 3 or 4 optimally orientated coplanar intensity modulated beams, without having clinically significant losses in treatment outcome from the optimal dose distribution.By using exhaustive search methods, the optimal coplanar beam directions for intensity modulated photon beams for early breast cancer and the optimal non-coplanar directions for an advanced cervix cancer were investigated. Although time consuming, exhaustive search methods have the advantage of revealing most features involving interactions between a small number of beams and how this may influence the treatment outcome. Thus phase spaces may serve as a general database for selecting an almost optimal treatment configuration for similar patients. Previous knowledge acquired with physically optimized uniform beam radiation therapy may not apply when intensity modulated biological optimization is used. Thus unconventional treatment directions were sometimes found.
  •  
2.
  •  
3.
  • Costa Ferreira, Brigida, et al. (författare)
  • The impact of different dose-response parameters on biologically optimized IMRT in breast cancer.
  • 2008
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 53:10, s. 2733-52
  • Tidskriftsartikel (refereegranskat)abstract
    • The full potential of biologically optimized radiation therapy can only be maximized with the prediction of individual patient radiosensitivity prior to treatment. Unfortunately, the available biological parameters, derived from clinical trials, reflect an average radiosensitivity of the examined populations. In the present study, a breast cancer patient of stage I-II with positive lymph nodes was chosen in order to analyse the effect of the variation of individual radiosensitivity on the optimal dose distribution. Thus, deviations from the average biological parameters, describing tumour, heart and lung response, were introduced covering the range of patient radiosensitivity reported in the literature. Two treatment configurations of three and seven biologically optimized intensity-modulated beams were employed. The different dose distributions were analysed using biological and physical parameters such as the complication-free tumour control probability (P(+)), the biologically effective uniform dose (D), dose volume histograms, mean doses, standard deviations, maximum and minimum doses. In the three-beam plan, the difference in P(+) between the optimal dose distribution (when the individual patient radiosensitivity is known) and the reference dose distribution, which is optimal for the average patient biology, ranges up to 13.9% when varying the radiosensitivity of the target volume, up to 0.9% when varying the radiosensitivity of the heart and up to 1.3% when varying the radiosensitivity of the lung. Similarly, in the seven-beam plan, the differences in P(+) are up to 13.1% for the target, up to 1.6% for the heart and up to 0.9% for the left lung. When the radiosensitivity of the most important tissues in breast cancer radiation therapy was simultaneously changed, the maximum gain in outcome was as high as 7.7%. The impact of the dose-response uncertainties on the treatment outcome was clinically insignificant for the majority of the simulated patients. However, the jump from generalized to individualized radiation therapy may significantly increase the therapeutic window for patients with extreme radio sensitivity or radioresistance, provided that these are identified. Even for radiosensitive patients a simple treatment technique is sufficient to maximize the outcome, since no significant benefits were obtained with a more complex technique using seven intensity-modulated beams portals.
  •  
4.
  •  
5.
  • dos Santos Matias, Lucilio (författare)
  • Optimization of brachytherapy for cervical cancer using inverse planning algorithms.
  • 2015
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Carcinoma of the cervix is a global problem. Brachytherapy (BT) is one of the mainradiation therapy components used in the management of cervical cancer. With theadvent of scientific and technological developments in treatment planning, inverse optimizationin BT has been imposed; however, to harness the full potential of inverseplanning in brachytherapy, its thorough comparison with manual optimization methodsis warranted.Although inverse optimization algorithms are based on different mathematical approaches,their goals are similar. The underlying principles of these algorithms willallow them to be applied with the aim of respecting normal structures absorbed doselimits while delivering high enough tumouricidal dose.In this work, the physical parameters minimum dose received by 98% and 90% ofthe target volume represented by D98 and D90, respectively, were used to evaluate thetreatment plans with respect to the target while the minimum dose received by 2cm3volume, D2cm3 , was used to investigate complications in organs at risk (OARs). Theconformity index (COIN), was used to describe the coverage of the target by the prescribeddose (PD) and the fraction of each OAR volume that receives a critical dose,which may cause complication. The treatment plan evaluation was also performedin terms of the complication-free tumour control probability, P+. The physical andradiobiological evaluation corresponding to plans obtained by the inverse planningsimulated annealing algorithm (IPSA) and the hybrid inverse planning optimization(HIPO) have been compared with corresponding ones for plans obtained using a manualgraphical optimization method.The main observations of this work are that well tuned class solutions of inverseoptimization methods are able to produce similar dose volume histograms to thoseproduced with manual graphical optimization and inverse methods have the potentialto spare organs at risk while delivering acceptable dose to the target. In addition, radiobiologicalindexes such as the P+ can be useful complements to physical parametersin treatment plan evaluation.
  •  
6.
  • Ferreira, Brigida Costa, et al. (författare)
  • Effective beam directions using radiobiologically optimized IMRT of node positive breast cancer
  • 2006
  • Ingår i: Physica medica (Testo stampato). - 1120-1797 .- 1724-191X. ; 22:1, s. 3-15
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to investigate the optimal coplanar beam directions when treating an early breast cancer with locoregional lymphatic spread with a few radiobiologically optimized intensity modulated beams. Also to determine the increase in the probability of complication-free cure with the number of beam portals and the smallest number required to perform a close to optimal treatment for this tumour site. Four test patients with stage II left-sided breast cancer were studied with heart, lung and contralateral breast as principal organs at risk. The clinical target volume consisted of the breast tissue remaining after surgery, the axillary, the internal mammary as well as the supraclavicular lymph nodes. Through an exhaustive search of all possible beam directions the most effective coplanar beams with one to four intensity modulated photon beam portals were investigated. Comparisons with uniform beam treatment techniques and up to 12 intensity modulated beams were also made. The different plans were optimized using the probability of complication-free tumour cure, P+, as biological objective function. When using two intensity modulated beam directions three major sets of suitable directions were identified denoted by A, P and T A corresponds to an anterior oblique pair of beams around 25 degrees and 325 degrees, P is a perpendicular lateral pair at around 50 and 130 whereas T is a more conventional tangential pair at around 155 degrees and 300 degrees. Interestingly, these configurations identify simply three major effective beam directions namely at 30 degrees +/- 20 degrees, 145 degrees +/- 20 degrees and 310 degrees +/- 15 degrees. For the three intensity modulated beam technique a combination of these three effective beam directions generally covered the global maximum of the probability of complication-free tumour control. The improvement in complication-free cure probability with two optimally selected intensity modulated beams is around 10% when compared to a uniform beam technique with three to four beam portals. This increase is mainly due to a reduction by almost 1% in the probability of injury to the heart and an increase of 6% in the probability of local tumour control. When three or four biologically optimized beam portals are used a further increase in the probability of complication-free cure of about 6% can often be obtained. This improvement is caused by a small decrease in the probability of injury to the heart, left lung and other surrounding normal tissue, as well as a slight further increase in the probability of tumour control. The increase in the treatment outcome is minimal when more than four intensity modulated beams are employed. A small increase in dose homogeneity in the target volume and a slight decrease in the normal tissue volume receiving high dose may be seen, but without appreciably improving the complication-free cure probability. For a stage II breast cancer, three and in more complex cases four optimally oriented beams are sufficient to reach close to the maximum probability of complication-free tumour control when biologically optimized intensity modulated dose delivery is used. Angle of incidence optimization may then be advantageous starting from the given most effective three beam directions.
  •  
7.
  • Mavroidis, Panayiotis, et al. (författare)
  • Analysis of fractionation correction methodologies for multiple phase treatment plans in radiation therapy
  • 2013
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 40:3, s. 031715-
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of performing the fractionation correction to the total dose-volume histograms, obtained by the arithmetical sum of the different plans, becomes inaccurate for more heterogeneous dose patterns. In this study, the differences between these two fractionation correction methods, named here as exact (corrected before) and approximate (after summation), respectively, are assessed for different cancer types. Methods: Prostate, breast, and head and neck (HN) tumor patients were selected to quantify the differences between two fractionation correction methods (the exact vs the approximate). For each cancer type, two different treatment plans were developed using uniform (CRT) and intensity modulated beams (IMRT), respectively. The responses of the target and normal tissue were calculated using the Poisson linear-quadratic-time model and the relative seriality model, respectively. All treatments were radiobiologically evaluated and compared using the complication-free tumor control probability (P+), the biologically effective uniform dose ((D) double under bar) together with common dosimetric criteria. Results: For the prostate cancer patient, an underestimation of around 14%-15% in P+ was obtained when the fractionation correction was applied after summation compared to the exact approach due to significant biological and dosimetric variations obtained between the two fractionation correction methods in the involved lymph nodes. For the breast cancer patient, an underestimation of around 3%-4% in the maximum dose in the heart was obtained. Despite the dosimetric differences in this organ, no significant variations were obtained in treatment outcome. For the HN tumor patient, an underestimation of about 5% in treatment outcome was obtained for the CRT plan as a result of an underestimation of the planning target volume control probability by about 10%. An underestimation of about 6% in the complication probability of the right parotid was also obtained. For all the other organs at risk, dosimetric differences of up to 4% were obtained but with no significant impact in the expected clinical outcome. However, for the IMRT plan, an overestimation in P+ of 4.3% was obtained mainly due to an underestimation of the complication probability of the left and right parotids (2.9% and 5.8%, respectively). Conclusions: The use of the exact fractionation correction method, which is applying fractionation correction on the separate dose distributions of a multiple phase treatment before their summation was found to have a significant expected clinical impact. For regions of interest that are irradiated with very heterogeneous dose distributions and significantly different doses per fraction in the different treatment phases, the exact fractionation correction method needs to be applied since a significant underestimation of the true patient outcome can be introduced otherwise.
  •  
8.
  • Mavroidis, Panayiotis, et al. (författare)
  • Comparison of the helical tomotherapy and MLC-based IMRT radiation modalities in treating brain and cranio-spinal tumors.
  • 2009
  • Ingår i: Technology in Cancer Research & Treatment. - : SAGE Publications. - 1533-0346 .- 1533-0338. ; 8:1, s. 3-14
  • Tidskriftsartikel (refereegranskat)abstract
    • The investigation of the clinical efficacy and effectiveness of Intensity Modulated Radiotherapy (IMRT) using Multileaf Collimators (MLC) and Helical Tomotherapy (HT) has been an issue of increasing interest over the past few years. In order to assess the suitability of a treatment plan, dosimetric criteria such as dose-volume histograms (DVH), maximum, minimum, mean, and standard deviation of the dose distribution are typically used. Nevertheless, the radiobiological parameters of the different tumors and normal tissues are often not taken into account. The use of the biologically effective uniform dose (D=) together with the complication-free tumor control probability (P(+)) were applied to evaluate the two radiation modalities. Two different clinical cases of brain and cranio-spinal axis cancers have been investigated by developing a linac MLC-based step-and-shoot IMRT plan and a Helical Tomotherapy plan. The treatment plans of the MLC-based IMRT were developed on the Philips treatment planning station using the Pinnacle 7.6 software release while the dedicated Tomotherapy treatment planning station was used for the HT plan. With the use of the P(+) index and the D(=) concept as the common prescription point, the different treatment plans were compared based on radiobiological measures. The tissue response probabilities were plotted against D(=) for a range of prescription doses. The applied plan evaluation method shows that in the brain cancer, the HT treatment gives slightly better results than the MLC-based IMRT in terms of optimum expected clinical outcome (P(+) of 66.1% and 63.5% for a D(=) to the PTV of 63.0 Gy and 62.0 Gy, respectively). In the cranio-spinal axis cancer, the HT plan is significantly better compared to the MLC-based IMRT plan over the clinically useful dose prescription range (P(+) of 84.1% and 28.3% for a D(=) to the PTV of 50.6 Gy and 44.0 Gy, respectively). If a higher than 5% risk for complications could be allowed, the complication-free tumor control could be increased by almost 30% compared to the initial dose prescription. In comparison to MLC based-IMRT, HT can better encompass the often large PTV while minimizing the volume of the OARs receiving high dose. A radiobiological treatment plan evaluation can provide a closer association of the delivered treatment with the clinical outcome by taking into account the dose-response relations of the irradiated tumors and normal tissues. The use of P - (D=) diagrams can complement the traditional tools of evaluation such as DVHs, in order to compare and effectively evaluate different treatment plans.
  •  
9.
  •  
10.
  • Mavroidis, Panayiotis, et al. (författare)
  • Response-probability volume histograms and iso-probability of response charts in treatment plan evaluation
  • 2011
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405. ; 38:5, s. 2382-2397
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: This study aims at demonstrating a new method for treatment plan evaluation and comparison based on the radiobiological response of individual voxels. This is performed by applying them on three different cancer types and treatment plans of different conformalities. Furthermore, their usefulness is examined in conjunction with traditionally applied radiobiological and dosimetric treatment plan evaluation criteria. Methods: Three different cancer types (head and neck, breast and prostate) were selected to quantify the benefits of the proposed treatment plan evaluation method. In each case, conventional conformal radiotherapy (CRT) and intensity modulated radiotherapy (IMRT) treatment configurations were planned. Iso-probability of response charts was produced by calculating the response probability in every voxel using the linear-quadratic-Poisson model and the dose-response parameters of the corresponding structure to which this voxel belongs. The overall probabilities of target and normal tissue responses were calculated using the Poisson and the relative seriality models, respectively. The 3D dose distribution converted to a 2 Gy fractionation, D(2GY) and iso-BED distributions are also shown and compared with the proposed methodology. Response-probability volume histograms (RVH) were derived and compared with common dose volume histograms (DVH). The different dose distributions were also compared using the complication-free tumor control probability, P(+), the biologically effective uniform dose, (sic), and common dosimetric criteria. Results: 3D Iso-probability of response distributions is very useful for plan evaluation since their visual information focuses on the doses that are likely to have a larger clinical effect in that particular organ. The graphical display becomes independent of the prescription dose highlighting the local radiation therapy effect in each voxel without the loss of important spatial information. For example, due to the exponential nature of the Poisson distribution, cold spots in the target volumes or hot spots in the normal tissues are much easier to be identified. Response-volume histograms, as DVH, can also be derived and used for plan comparison. RVH are advantageous since by incorporating the radiobiological properties of each voxel they summarize the 3D distribution into 2D without the loss of relevant information. Thus, more clinically relevant radiobiological objectives and constraints could be defined and used in treatment planning optimization. These measures become increasingly important when dose distributions need to be designed according to the microscopic biological properties of tumor and normal tissues. Conclusions: The proposed methods do not aim to replace quantifiers like the probabilities of total tissue response, which ultimately are the quantities of interest to evaluate treatment success. However, iso-probability of response charts and response-probability volume histograms illustrates more clearly the difference in effectiveness between different treatment plans than the information provided by alternative dosimetric data. The use of 3D iso-probability of response distributions could serve as a good descriptor of the effectiveness of a dose distribution indicating primarily the regions in a tissue that dominate its response.
  •  
11.
  • Mavroidis, Panayiotis, et al. (författare)
  • Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.
  • 2007
  • Ingår i: Phys Med Biol. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 52:13, s. 3817-36
  • Tidskriftsartikel (refereegranskat)abstract
    • The rapid implementation of advanced treatment planning and delivery technologies for radiation therapy has brought new challenges in evaluating the most effective treatment modality. Intensity-modulated radiotherapy (IMRT) using multi-leaf collimators (MLC) and helical tomotherapy (HT) are becoming popular modes of treatment delivery and their application and effectiveness continues to be investigated. Presently, there are several treatment planning systems (TPS) that can generate and optimize IMRT plans based on user-defined objective functions for the internal target volume (ITV) and organs at risk (OAR). However, the radiobiological parameters of the different tumours and normal tissues are typically not taken into account during dose prescription and optimization of a treatment plan or during plan evaluation. The suitability of a treatment plan is typically decided based on dosimetric criteria such as dose-volume histograms (DVH), maximum, minimum, mean and standard deviation of the dose distribution. For a more comprehensive treatment plan evaluation, the biologically effective uniform dose (D) is applied together with the complication-free tumour control probability (P(+)). Its utilization is demonstrated using three clinical cases that were planned with two different forms of IMRT. In this study, three different cancer types at different anatomical sites were investigated: head and neck, lung and prostate cancers. For each cancer type, a linac MLC-based step-and-shoot IMRT plan and a HT plan were developed. The MLC-based IMRT treatment plans were developed on the Philips treatment-planning platform, using the Pinnacle 7.6 software release. For the tomotherapy HiArt plans, the dedicated tomotherapy treatment planning station was used, running version 2.1.2. By using D as the common prescription point of the treatment plans and plotting the tissue response probabilities versus D for a range of prescription doses, a number of plan trials can be compared based on radiobiological measures. The applied plan evaluation method shows that in the head and neck cancer case the HT treatment gives better results than MLC-based IMRT in terms of expected clinical outcome P(+) of 62.2% and 46.0%, D to the ITV of 72.3 Gy and 70.7 Gy, respectively). In the lung cancer and prostate cancer cases, the MLC-based IMRT plans are better over the clinically useful dose prescription range. For the lung cancer case, the HT and MLC-based IMRT plans give a P(+) of 66.9% and 72.9%, D to the ITV of 64.0 Gy and 66.9 Gy, respectively. Similarly, for the prostate cancer case, the two radiation modalities give a P(+) of 68.7% and 72.2%, D to the ITV of 86.0 Gy and 85.9 Gy, respectively. If a higher risk of complications (higher than 5%) could be allowed, the complication-free tumour control could increase by over 40%, 2% and 30% compared to the initial dose prescription for the three cancer cases, respectively. Both MLC-based IMRT and HT can encompass the often-large ITV required while they minimize the volume of the organs at risk receiving high doses. Radiobiological evaluation of treatment plans may provide an improved correlation of the delivered treatment with the clinical outcome by taking into account the dose-response characteristics of the irradiated targets and normal tissues. There may exist clinical cases, which may look dosimetrically similar but in radiobiological terms may be quite different. In such situations, traditional dose-based evaluation tools can be complemented by the use of P(+)--D diagrams to effectively evaluate and compare treatment plans.
  •  
12.
  • Su, Fan-Chi, et al. (författare)
  • A graphic user interface toolkit for specification, report and comparison of dose-response relations and treatment plans using the biologically effective uniform dose
  • 2010
  • Ingår i: Computer Methods and Programs in Biomedicine. - : Elsevier BV. - 0169-2607 .- 1872-7565. ; 100:1, s. 69-78
  • Tidskriftsartikel (refereegranskat)abstract
    • A toolkit (BEUDcal) has been developed for evaluating the effectiveness and for predicting the outcome of treatment plans by calculating the biologically effective uniform dose (BEUD) and complication-free tumor control probability. The input for the BEUDcal is the differential dose-volume histograms of organs exported from the treatment planning system. A clinical database is built for the dose-response parameters of different tumors and normal tissues. Dose-response probabilities of all the examined organs are illustrated together with the corresponding BEUDs and the P+ values. Furthermore, BEUDcal is able to generate a report that simultaneously presents the radiobiological evaluation together with the physical dose indices, showing the complementary relation between the physical and radiobiological treatment plan analysis performed by BEUDcal. Comparisons between treatment plans for helical tomotherapy and multileaf collimator-based intensity modulated radiotherapy of a lung patient were demonstrated to show the versatility of BEUDcal in the assessment and report of dose-response relations.
  •  
13.
  • Tzikas, Athanasios, et al. (författare)
  • Radiobiological Evaluation of Breast Cancer Radiotherapy Accounting for the Effects of Patient Positioning and Breathing in Dose Delivery. A Meta Analysis
  • 2013
  • Ingår i: Technology in Cancer Research & Treatment. - : SAGE Publications. - 1533-0346 .- 1533-0338. ; 12:1, s. 31-44
  • Tidskriftsartikel (refereegranskat)abstract
    • In breast cancer radiotherapy, significant discrepancies in dose delivery can contribute to underdosage of the tumor or overdosage of normal tissue, which is potentially related to a reduction of local tumor control and an increase of side effects. To study the impact of these factors in breast cancer radiotherapy, a meta analysis of the clinical data reported by Mavroidis et al. (2002) in Acta Oncol (41:471-85), showing the patient setup and breathing uncertainties characterizing three different irradiation techniques, were employed. The uncertainties in dose delivery are simulated based on fifteen breast cancer patients (5 mastectomized, 5 resected with negative node involvement (R) and 5 resected with positive node involvement (R+)), who were treated by three different irradiation techniques, respectively. The positioning and breathing effects were taken into consideration in the determination of the real dose distributions delivered to the CTV and lung in each patient. The combined frequency distributions of the positioning and breathing distributions were obtained by convolution. For each patient the effectiveness of the dose distribution applied is calculated by the Poisson and relative seriality models and a set of parameters that describe the dose-response relations of the target and lung. The three representative radiation techniques are compared based on radiobiological measures by using the complication-free tumor control probability, P+ and the biologically effective uniform dose, E, concepts. For the Mastectomy case, the average P+ values of the planned and delivered dose distributions are 93.8% for a (sic)(CTV) of 51.8 Gy and 85.0% for a (sic)(CTV) of 50.3 Gy, respectively. The respective total control probabilities, P-B values are 94.8% and 92.5%, whereas the corresponding total complication probabilities, P-I values are 0.9% and 7.4%. For the R- case, the average P+ values are 89.4% for a (sic)(CTV) of 48.9 Gy and 88.6% for a (sic)(CTV) of 49.0 Gy, respectively. The respective PB values are 89.8% and 89.9%, whereas the corresponding PI values are 0.4% and 1.2%. For the R+ case, the average P+ values are 86.1% for a (sic)(CTV) of 49.2 Gy and 85.5% for a (sic)(CTV) of 49.1 Gy, respectively. The respective PB values are 90.2% and 90.1%, whereas the corresponding P-I values are 4.1% and 4.6%. The combined effects of positioning uncertainties and breathing can introduce a significant deviation between the planned and delivered dose distributions in lung in breast cancer radiotherapy. The positioning and breathing uncertainties do not affect much the dose distribution to the CTV. The simulated delivered dose distributions show larger lung complication probabilities than the treatment plans. This means that in clinical practice the true expected complications are underestimated. Radiation pneumonitis of Grade 1-2 is more frequent and any radiotherapy optimization should use this as a more clinically relevant endpoint.
  •  