SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Crabtree Kyle PhD) "

Sökning: WFRF:(Crabtree Kyle PhD)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hausmaninger, Thomas, 1987- (författare)
  • Mid- and near-infrared NICE-OHMS : techniques for ultra-sensitive detection of molecules in gas phase
  • 2018
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS) is a technique for ultra-sensitive detection of molecular absorption and dispersion. For highest performance, the technique combines cavity enhancement (CE) with frequency modulation (FM); while the former increases the effective interaction length between the light and the analyte by several orders of magnitudes, the latter removes the in-coupling of 1/f noise and makes the signals background free. The combination of CE and FM also gives the technique an immunity to amplitude noise caused by the jitter of the laser frequency relative to the cavity resonance frequencies. All these properties make the technique suitable for ultra sensitive trace gas detection in the sub-parts-per-trillion (ppt) range. The aim of this thesis is to improve the performance of the NICE-OHMS technique and to increase its range of applications.The work in this thesis can be divided into three areas:Firstly, a mid-infrared (MIR)-NICE-OHMS instrumentation was developed. In a first realization an unprecedented white-noise equivalent absorption limit for Doppler broadened (Db) detection in the MIR of 3×10-9 cm-1Hz-1/2was demonstrated. This was subsequently improved to 2.4×10-10 cm-1Hz-1/2allowing for detection methane and its two main isotopologues (CH3D and 13CH4) at their natural abundance.Secondly, further development of an existing near-infrared NICE-OHMS system was performed. This resulted in an improved longtime stability and the first shot-noise limited NICE-OHMS system for Db detection with a noise equivalent absorption limit of 2.3×10-14 cm-1detected over 200 s. Thirdly, models and theoretical descriptions of NICE-OHMS signals under strong absorption conditions and from methane under high laser power were developed. It was experimentally verified that the models allow for a more accurate evaluation of NICE-OHMS signals under a wide range of conditions.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
doktorsavhandling (1)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Axner, Ove, Professo ... (1)
Hausmaninger, Thomas ... (1)
Crabtree, Kyle, PhD (1)
Lärosäte
Umeå universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy