SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(DAgata Roberta) "

Sökning: WFRF:(DAgata Roberta)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Berto, Marcello, et al. (författare)
  • EGOFET Peptide Aptasensor for Label-Free Detection of Inflammatory Cytokines in Complex Fluids
  • 2018
  • Ingår i: ADVANCED BIOSYSTEMS. - : WILEY-V C H VERLAG GMBH. - 2366-7478. ; 2:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Organic electronic transistors are rapidly emerging as ultrahigh sensitive label-free biosensors suited for point-of-care or in-field deployed applications. Most organic biosensors reported to date are based on immunorecognition between the relevant biomarkers and the immobilized antibodies, whose use is hindered by large dimensions, poor control of sequence, and relative instability. Here, an electrolyte-gated organic field effect transistor (EGOFET) biosensor where the recognition units are surface immobilized peptide aptamers (Affimer proteins) instead of antibodies is reported. Peptide aptasensor for the detection of the pro-inflammatory cytokine tumor necrosis factor alpha (TNF alpha) with a 1 x 10(-12) M limit of detection is demonstrated. Ultralow sensitivity is met even in complex solutions such as cell culture media containing 10% serum, demonstrating the remarkable ligand specificity of the device. The device performances, together with the simple one-step immobilization strategy of the recognition moieties and the low operational voltages, all prompt EGOFET peptide aptasensors as candidates for early diagnostics and monitoring at the point-of-care.
  •  
2.
  • Rich, Rebecca L., et al. (författare)
  • A global benchmark study using affinity-based biosensors
  • 2009
  • Ingår i: Analytical Biochemistry. - : Elsevier BV. - 0003-2697 .- 1096-0309. ; 386:2, s. 194-216
  • Tidskriftsartikel (refereegranskat)abstract
    • To explore the variability in biosensor studies, 150 participants from 20 countries were given the same protein samples and asked to determine kinetic rate constants for the interaction. We chose a protein system that was amenable to analysis using different biosensor platforms as well as by users of different expertise levels. The two proteins (a 50-kDa Fab and a 60-kDa glutathione S-transferase [GST] antigen) form a relatively high-affinity complex, so participants needed to optimize several experimental parameters, including ligand immobilization and regeneration conditions as well as analyte concentrations and injection/dissociation times. Although most participants collected binding responses that could be fit to yield kinetic parameters, the quality of a few data sets could have been improved by optimizing the assay design. Once these outliers were removed, the average reported affinity across the remaining panel of participants was 620 pM with a standard deviation of 980 pM. These results demonstrate that when this biosensor assay was designed and executed appropriately, the reported rate constants were consistent, and independent of which protein was immobilized and which biosensor was used.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy