SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(De Fiore Luca) "

Sökning: WFRF:(De Fiore Luca)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abelev, Betty, et al. (författare)
  • Underlying Event measurements in pp collisions at root s=0.9 and 7 TeV with the ALICE experiment at the LHC
  • 2012
  • Ingår i: Journal of High Energy Physics. - 1029-8479. ; :7
  • Tidskriftsartikel (refereegranskat)abstract
    • We present measurements of Underlying Event observables in pp collisions at root s = 0 : 9 and 7 TeV. The analysis is performed as a function of the highest charged-particle transverse momentum p(T),L-T in the event. Different regions are defined with respect to the azimuthal direction of the leading (highest transverse momentum) track: Toward, Transverse and Away. The Toward and Away regions collect the fragmentation products of the hardest partonic interaction. The Transverse region is expected to be most sensitive to the Underlying Event activity. The study is performed with charged particles above three different p(T) thresholds: 0.15, 0.5 and 1.0 GeV/c. In the Transverse region we observe an increase in the multiplicity of a factor 2-3 between the lower and higher collision energies, depending on the track p(T) threshold considered. Data are compared to PYTHIA 6.4, PYTHIA 8.1 and PHOJET. On average, all models considered underestimate the multiplicity and summed p(T) in the Transverse region by about 10-30%.
  •  
2.
  • Abelev, Betty, et al. (författare)
  • Long-range angular correlations on the near and away side in p-Pb collisions at root S-NN=5.02 TeV
  • 2013
  • Ingår i: Physics Letters. Section B: Nuclear, Elementary Particle and High-Energy Physics. - : Elsevier BV. - 0370-2693. ; 719:1-3, s. 29-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Angular correlations between charged trigger and associated particles are measured by the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV for transverse momentum ranges within 0.5 < P-T,P-assoc < P-T,P-trig < 4 GeV/c. The correlations are measured over two units of pseudorapidity and full azimuthal angle in different intervals of event multiplicity, and expressed as associated yield per trigger particle. Two long-range ridge-like structures, one on the near side and one on the away side, are observed when the per-trigger yield obtained in low-multiplicity events is subtracted from the one in high-multiplicity events. The excess on the near-side is qualitatively similar to that recently reported by the CMS Collaboration, while the excess on the away-side is reported for the first time. The two-ridge structure projected onto azimuthal angle is quantified with the second and third Fourier coefficients as well as by near-side and away-side yields and widths. The yields on the near side and on the away side are equal within the uncertainties for all studied event multiplicity and p(T) bins, and the widths show no significant evolution with event multiplicity or p(T). These findings suggest that the near-side ridge is accompanied by an essentially identical away-side ridge. (c) 2013 CERN. Published by Elsevier B.V. All rights reserved.
  •  
3.
  • Abelev, Betty, et al. (författare)
  • Measurement of prompt J/psi and beauty hadron production cross sections at mid-rapidity in pp collisions at root s=7 TeV
  • 2012
  • Ingår i: Journal of High Energy Physics. - 1029-8479. ; :11
  • Tidskriftsartikel (refereegranskat)abstract
    • The ALICE experiment at the LHC has studied J/psi production at mid-rapidity in pp collisions at root s = 7 TeV through its electron pair decay on a data sample corresponding to an integrated luminosity L-int = 5.6 nb(-1). The fraction of J/psi from the decay of long-lived beauty hadrons was determined for J/psi candidates with transverse momentum p(t) > 1,3 GeV/c and rapidity vertical bar y vertical bar < 0.9. The cross section for prompt J/psi mesons, i.e. directly produced J/psi and prompt decays of heavier charmonium states such as the psi(2S) and chi(c) resonances, is sigma(prompt J/psi) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 8.3 +/- 0.8(stat.) +/- 1.1 (syst.)(-1.4)(+1.5) (syst. pol.) mu b. The cross section for the production of b-hadrons decaying to J/psi with p(t) > 1.3 GeV/c and vertical bar y vertical bar < 0.9 is a sigma(J/psi <- hB) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 1.46 +/- 0.38 (stat.)(-0.32)(+0.26) (syst.) mu b. The results are compared to QCD model predictions. The shape of the p(t) and y distributions of b-quarks predicted by perturbative QCD model calculations are used to extrapolate the measured cross section to derive the b (b) over bar pair total cross section and d sigma/dy at mid-rapidity.
  •  
4.
  •  
5.
  • 2021
  • swepub:Mat__t
  •  
6.
  • Anelli, M., et al. (författare)
  • Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 617:1-3, s. 107-108
  • Tidskriftsartikel (refereegranskat)abstract
    • We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. We show preliminary measurement carried out with a different prototype with a larger lead/fiber ratio, which proves the relevance of passive material to neutron detection efficiency in this kind of calorimeters.
  •  
7.
  • Anelli, M., et al. (författare)
  • Measurement of the neutron detection efficiency of a 80% absorber-20% scintillating fibers calorimeter
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 626, s. 67-71
  • Tidskriftsartikel (refereegranskat)abstract
    • The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.
  •  
8.
  • Cascini, Silvia, et al. (författare)
  • Case Identification and Characterization of Migrants with Dementia in the Lazio Region Using Health Administrative Data
  • 2023
  • Ingår i: Journal of Alzheimer's Disease. - 1387-2877 .- 1875-8908. ; 92:3, s. 843-852
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A crucial step for planning effective public health policies for migrants with dementia is the collection of data on the local dimensions of the phenomenon and patients’ characteristics.Objective: This study aimed to identify and characterize migrants with dementia in the Lazio region using health administrative databases.Methods: Residents with dementia aged 50 years or older, living in the Lazio region as of December 31, 2018, were identified using a validated algorithm based on hospital discharge(s), claims for antidementia drugs, and co-payment exemption for dementia. Migrants were defined as people born abroad and grouped in migrants from High Migratory Pressure Countries (HMPCs) and Highly Developed Countries (HDCs). Overall and age-specific prevalence rates were estimated in native- and foreign-born patients.Results: Dementia was ascertained in 38,460 residents. Among them, 37,280 (96.9%) were born in Italy, 337 (0.9%) were migrants from HDCs, and 843 (2.2%) from HMPCs. Dementia prevalence was higher among natives (1.15%, 95% CI 1.14–1.16) relative to migrants from HDCs (0.60%, 95% CI 0.54–0.67) and HMPCs (0.29%, 95% CI 0.27–0.31). The prevalence of comorbidities did not differ between groups. Migrants with dementia had a lower likelihood of receiving antidementia treatments compared with natives (51.6% in migrants from HDCs, 49.3% in migrants from HMPCs, and 53.5% among Italians).Conclusion: Routinely collected data in healthcare administrative databases can support the identification of migrants with dementia. Migrants exhibited a lower age-standardized prevalence of registered dementia and lower access to dedicated treatments than Italians. These findings are suggestive of underdiagnosis and undertreatment of dementia in migrants.
  •  
9.
  • Mauro, M. P.Di, et al. (författare)
  • Low-cost measurements of the 'resonant' wavelengths reflected by a compact disk under skimming rays
  • 2024
  • Ingår i: European Journal of Physics. - 1361-6404. ; 45:1
  • Tidskriftsartikel (refereegranskat)abstract
    • We demonstrate the construction and utilization of an affordable apparatus using readily available materials to accurately measure in a quantitative manner the wavelengths reflected by a compact disc (CD) under skimming light rays. In fact, only a limited number of wavelengths can be revealed when light rays from a white lamp are directed at a CD (or a DVD) in a manner that specifically selects the rays that graze the surface of the horizontally held disc. We compare the results with the ones obtained with a commercial spectrometer, finding that they are in good agreement among them and with the theoretical predictions.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy