SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Dominguez Vicent A) "

Sökning: WFRF:(Dominguez Vicent A)

  • Resultat 1-50 av 50
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Recchioni, A, et al. (författare)
  • Enhancing Clinical Decision-Making in Complex Corneal Disorders: The Role of In-Vivo Confocal Microscopy
  • 2023
  • Ingår i: Life (Basel, Switzerland). - : MDPI AG. - 2075-1729. ; 13:3
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • This study aims to describe how in-vivo confocal microscopy (ICVM) results improved diagnosis and treatment in three patients with complex corneal disorders at a single institution. Case one was a 36-year-old woman contact lens wearer referred to the hospital eye service (HES) by her community optician for a suspected corneal ulcer in her left eye. The case demonstrated that where laboratory cell culture was inconclusive, IVCM imaging improved diagnosis and more importantly adjusted the initial treatment till the complete resolution of the case. Case two was a shared-care 66-year-old keratoconus patient under a complex immunosuppression regime who had developed a recent series of post-surgical complications of fungal origin and was experiencing eye pain. IVCM was able to differentiate between an immune-mediated response and fungal keratitis and guide the clinicians towards an optimized treatment. Case three was a long-standing dry eye disease in a 64-year-old woman diagnosed with primary Sjögren’s syndrome where previous treatments failed to improve her symptomatology. IVCM was crucial for prescribing allogeneic serum eyedrops by anticipating early immune changes in the sub-basal corneal nerve plexus. In-vivo confocal microscopy can be an essential non-invasive imaging technique for improving clinicians’ diagnostic precision by adding a layer of certainty that other techniques may lack. Additionally, IVCM allows adjustment of the treatment accordingly, by instantly following any pathologic changes at the cellular level.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Tribble, James R., et al. (författare)
  • Nicotinamide provides neuroprotection in glaucoma by protecting against mitochondrial and metabolic dysfunction
  • 2021
  • Ingår i: Redox Biology. - : Elsevier. - 2213-2317. ; 43
  • Tidskriftsartikel (refereegranskat)abstract
    • Nicotinamide adenine dinucleotide (NAD) is a REDOX cofactor and metabolite essential for neuronal survival. Glaucoma is a common neurodegenerative disease in which neuronal levels of NAD decline. We assess the effects of nicotinamide (a precursor to NAD) on retinal ganglion cells (the affected neuron in glaucoma) in normal physiological conditions and across a range of glaucoma relevant insults including mitochondrial stress and axon degenerative insults. We demonstrate retinal ganglion cell somal, axonal, and dendritic neuroprotection by nicotinamide in rodent models which represent isolated ocular hypertensive, axon degenerative, and mitochondrial degenerative insults. We performed metabolomics enriched for small molecular weight metabolites for the retina, optic nerve, and superior colliculus which demonstrates that ocular hypertension induces widespread metabolic disruption, including consistent changes to α-ketoglutaric acid, creatine/creatinine, homocysteine, and glycerophosphocholine. This metabolic disruption is prevented by nicotinamide. Nicotinamide provides further neuroprotective effects by increasing oxidative phosphorylation, buffering and preventing metabolic stress, and increasing mitochondrial size and motility whilst simultaneously dampening action potential firing frequency. These data support continued determination of the utility of long-term nicotinamide treatment as a neuroprotective therapy for human glaucoma.
  •  
9.
  •  
10.
  •  
11.
  •  
12.
  •  
13.
  • Dominguez-Vicent, A, et al. (författare)
  • Agreement of different OCT scan directions for individual retinal-layer thickness measurements in multiple sclerosis subjects with prior unilateral optic neuritis
  • 2022
  • Ingår i: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 12:1, s. 566-
  • Tidskriftsartikel (refereegranskat)abstract
    • The similarities between horizontal and vertical Optical Coherence Tomography (OCT) scans for the individual retinal layer thickness measurements in the macula was evaluated. Two volumetric scans (B-scans oriented horizontally and vertically) were performed in 64 multiple sclerosis subjects with history of unilateral optic neuritis and 64 healthy controls. The agreement between the thickness measurements with horizontal and vertical OCT scans was evaluated in 3 groups of eyes: healthy controls, eyes with history of optic neuritis and the fellow eyes. The mean difference in individual layer thickness between the scans was smaller than the instrument’s axial resolution in all 3 groups. The limit of agreement (LoA) varied among the different layers and sectors analyzed and this trend was similar in all the groups. For the inner retinal layers (retinal nerve fiber layer to inner nuclear layer), the inner macular sectors had a larger LoA compared to the corresponding outer sectors. In the outer plexiform and nuclear layers, the central and inner sectors (except inner temporal) had LoA larger than the other sectors and layers. The larger LoA seen for different layers and sectors suggests that the scan direction must be same for the follow-up OCT measurements and in clinical studies.
  •  
14.
  •  
15.
  •  
16.
  •  
17.
  • Dominguez-Vicent, A, et al. (författare)
  • Effect of Instrument Design and Technique on the Precision and Accuracy of Objective Refraction Measurement
  • 2020
  • Ingår i: Journal of clinical medicine. - : MDPI AG. - 2077-0383. ; 9:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To evaluate the precision and accuracy of objective refraction measurement obtained with combinations of instrument design and technique. We also compared the performance of the instruments with subjective refraction measurements. Method and analysis: The objective refraction was measured in 71 subjects with three autorefractometers that have different designs and measurement principles (binocular with fogging, binocular without fogging, and monocular with fogging). Repeatability and reproducibility metrics were calculated for the objective refraction measurements. The agreement of the objective refraction measurements between the three instruments and the agreement with the subjective refraction measurements were evaluated. Results: All three autorefractometers had repeatability and reproducibility limits smaller than 0.70D. The smallest difference (0.10D) in the spherical equivalent was seen between the two binocular instruments. Compared with the subjective refraction, the binocular without fogging technique had the smallest mean difference in spherical equivalent (<0.20D) whereas the binocular fogging technique had the smallest limit of agreement interval (1.00D). For all comparisons, the mean difference and limit of agreement interval for the cylindrical components were lower than 0.10D and 0.75D, respectively. Conclusion: All three instruments evaluated had good repeatability and reproducibility. The binocular fogging technique provided the best agreement with subjective refraction.
  •  
18.
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  •  
25.
  •  
26.
  •  
27.
  • Dominguez-Vicent, A, et al. (författare)
  • Photopic and Mesopic Contrast Sensitivity Function in the Presence of Glare and the Effect of Filters in Young Healthy Adults
  • 2021
  • Ingår i: Frontiers in psychology. - : Frontiers Media SA. - 1664-1078. ; 12, s. 772661-
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The aim of this study was to evaluate the effect of four different filters on contrast sensitivity under photopic and mesopic conditions with and without glare.Methods: A forced choice algorithm in a Bayesian psychophysical procedure was utilized to evaluate the spatial luminance contrast sensitivity. Five different spatial frequencies were evaluated: 1.5, 3, 6, 12, and 18 cycles per degree (cpd). The measurements were performed under 4 settings: photopic and mesopic luminance with glare and no glare. Two long pass filters (LED light reduction and 511nm filter) and two selective absorption filters (ML41 and emerald filter) and a no filter condition were evaluated. The measurements were performed in 9 young subjects with healthy eyes.Results: For the no filter condition, there was no difference between glare and no glare settings for the photopic contrast sensitivity measurements whereas in the mesopic setting, glare reduced the contrast sensitivity significantly at all spatial frequencies. There was no statistically significant difference between contrast sensitivity measurements obtained with different filters under both photopic conditions and the mesopic glare condition. In the mesopic no glare condition, the contrast sensitivity at 6 cpd with 511, ML41 and emerald filters was significantly reduced compared to no filter condition (p = 0.045, 0.045, and 0.071, respectively). Similarly, with these filters the area under the contrast sensitivity function in the mesopic no glare condition was also reduced. A significant positive correlation was seen between the filter light transmission and the average AULCSF in the mesopic non-glare condition.Conclusion: The contrast sensitivity measured with the filters was not significantly different than the no filter condition in photopic glare and no glare setting as well as in mesopic glare setting. In mesopic setting with no glare, filters reduced contrast sensitivity.
  •  
28.
  • Dominguez-Vicent, A, et al. (författare)
  • Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
  • 2021
  • Ingår i: Frontiers in medicine. - : Frontiers Media SA. - 2296-858X. ; 8, s. 764236-
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate the precision of individual and combined macula and optic disc volumetric analysis, and the agreement between these two scan modes with spectral domain optical coherence tomography (OCT).Methods: Macular and optic disc volumetric measurements were performed with individual and combined scan protocols in one eye of 75 healthy subjects. Three repeated measurements were performed with each protocol. From the macular area, retinal thickness in nine different sectors and ganglion cell complex thickness in eight different sectors were analyzed from both scan modes. From the optic disc area, the peripapillary retinal nerve fiber layer (pRNFL) thickness in 12 clock sectors and the optic disc parameters were evaluated. For all the parameters, repeatability limit and agreement analysis were performed.Results: For the retinal thickness measurements in macula, the combined scan had two to three times larger repeatability limit than the individual scan for all the sectors except the central sector, where the repeatability limit was five times larger. The limits of agreement intervals were lower than 20 μm for all sectors, except the central. The ganglion cell complex measurements also had larger repeatability limits for the combined scans, and the limits of agreement intervals were &lt;10 μm for all sectors. For the pRNFL thickness, the repeatability values were distributed like a vertically elongated ellipse for both scans, but still the repeatability was better for individual scan compared to the combined scan. The shortest and widest interval are obtained for sectors 9 (9 μm) and 12 (40 μm), respectively. The repeatability limit was &lt;0.15 units for all disc parameters with both scan modes.Conclusion: The individual macula and optic disc scans had better repeatability than the combined scan mode, and the two scan modes cannot be used interchangeability due to the wide limits of agreement.
  •  
29.
  •  
30.
  •  
31.
  •  
32.
  •  
33.
  •  
34.
  •  
35.
  •  
36.
  • Esteve-Taboada, JJ, et al. (författare)
  • Reply
  • 2016
  • Ingår i: Journal of refractive surgery (Thorofare, N.J. : 1995). - 1081-597X. ; 151:5, s. 1039-1040
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
37.
  •  
38.
  •  
39.
  •  
40.
  •  
41.
  •  
42.
  •  
43.
  •  
44.
  •  
45.
  •  
46.
  •  
47.
  • Venkataraman, AP, et al. (författare)
  • Evaluation of the Performance of Algorithm-Based Methods for Subjective Refraction
  • 2020
  • Ingår i: Journal of clinical medicine. - : MDPI AG. - 2077-0383. ; 9:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To evaluate the performance of two subjective refraction measurement algorithms by comparing the refraction values, visual acuity, and the time taken by the algorithms with the standard subjective refraction (SSR). Methods: The SSR and two semi-automated algorithm-based subjective refraction (SR1 and SR2) in-built in the Vision-R 800 phoropter were performed in 68 subjects. In SR1 and SR2, the subject’s responses were recorded in the algorithm which continuously modified the spherical and cylindrical component accordingly. The main difference between SR1 and SR2 is the use of an initial fogging step in SR1. Results: The average difference and agreement limits intervals in the spherical equivalent between each refraction method were smaller than 0.25 D, and 2.00 D, respectively. For the cylindrical components, the average difference was almost zero and the agreement limits interval was less than 0.50 D. The visual acuities were not significantly different among the methods. The times taken for SR1 and SR2 were significantly shorter, and SR2 was on average was three times faster than SSR. Conclusions: The refraction values and the visual acuity obtained with the standard subjective refraction and algorithm-based methods were similar on average. The algorithm-based methods were significantly faster than the standard method.
  •  
48.
  •  
49.
  •  
50.
  • Zahavi, O, et al. (författare)
  • Evaluation of Automated Segmentation Algorithm for Macular Volumetric Measurements of Eight Individual Retinal Layer Thickness
  • 2021
  • Ingår i: APPLIED SCIENCES-BASEL. - : MDPI AG. - 2076-3417. ; 11:3
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • Background: We evaluated the performance of an automated algorithm available on a clinical OCT (Canon-HS100) for macular volumetric measurements of eight individual retinal layers. Methods and Analysis: Two consecutive three-dimensional scans were acquired on 29 subjects with healthy retinas. Thickness measurements were obtained from eight individual retinal layers in nine macular sectors based on Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. The repeatability was evaluated using the within-subject standard deviation from which the repeatability limits (Rlimit) and coefficient of variation (CoV) were calculated. Results: The repeatability metrics varied among different layers and sectors. The variation among the sectors was larger in two of the outer layers (plexiform and nuclear layer) and the retinal nerve fiber layer. For the other five layers, the repeatability limit was less than 5µm and CoV was less than 7.5% in all nine ETDRS sectors. Conclusions: The repeatability of the OCT-HS100 to measure eight individual retinal layers is good in general. Nevertheless, the repeatability is not homogeneous among different layers and sectors. This needs to be taken into account while designing clinical measurement protocols.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-50 av 50

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy