SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Endo Miyoko) "

Sökning: WFRF:(Endo Miyoko)

  • Resultat 1-13 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hatano, Masaru, et al. (författare)
  • Less frequent opening of the aortic valve and a continuous flow pump are risk factors for postoperative onset of aortic insufficiency in patients with a left ventricular assist device
  • 2011
  • Ingår i: Circulation Journal. - : Japanese Circulation Society. - 1346-9843 .- 1347-4820. ; 75:5, s. 1147-1155
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Postoperative development of aortic insufficiency (AI) after implantation of left ventricular assist devices (LVADs) has recently been recognized, but the devices in the previous reports have been limited to the HeartMate I or II. The purposes of this study were to determine whether AI develops with other types of LVADs and to elucidate the factors associated with the development of AI.METHODS AND RESULTS:Thirty-seven patients receiving LVADs without evident abnormalities in native aortic valves were enrolled (pulsatile flow LVAD [TOYOBO]: 76%, continuous flow LVAD [EVAHEART, DuraHeart, Jarvik2000, HeartMate II]: 24%). Frequency of aortic valve opening and grade of AI were evaluated by the most recent echocardiography during LVAD support. None of the patients had more than trace AI preoperatively. During LVAD support AI >- grade 2 developed in 9 patients (24%) across all 5 types of devices. More severe grade of AI correlated with higher plasma B-type natriuretic peptide concentration (r = 0.53, P < 0.01) and with less frequent of the aortic valve (r = 0.45, P < 0.01). Multivariate analysis revealed that lower preoperative left ventricular ejection fraction and a continuous flow device type were independent risk factors for higher incidence of AI.CONCLUSIONS:AI, which is hemodynamically significant, develops after implantation of various types of LVADs. Physicians need to be more alert to the development of AI particularly with continuous flow devices.
  •  
2.
  • Imamura, Teruhiko, et al. (författare)
  • Correction of hyponatremia by tolvaptan before left ventricular assist device implantation
  • 2012
  • Ingår i: International Heart Journal. - : International Heart Journal Association. - 1349-2365 .- 1349-3299. ; 53:6, s. 391-393
  • Tidskriftsartikel (refereegranskat)abstract
    • Hypervolemic hyponatremia is often complicated with advanced heart failure together with increased excretion of sodium by diuretics. Tolvaptan, an oral vasopressin-2-receptor antagonist, has been previously reported to improve congestion and correct hyponatremia through increased excretion of free water. However, there is little evidence concerning the administration of tolvaptan in patients with stage D heart failure. We experienced 2 patients with stage D heart failure who received 3.75 mg/day of tolvaptan to correct hyponatremia before ventricular assist device implantation. It may be useful, even for patients with stage D heart failure, to administer a low dose of tolvaptan to treat hyponatremia before ventricular assist device implantation to avoid a drastic alteration in serum sodium concentration perioperatively.
  •  
3.
  • Imamura, Teruhiko, et al. (författare)
  • Everolimus-incorporated immunosuppressant strategy improves renal dysfunction while maintaining low rejection rates after heart transplantation in Japanese patients
  • 2013
  • Ingår i: International Heart Journal. - : International Heart Journal Association. - 1349-2365 .- 1349-3299. ; 54:4, s. 222-227
  • Tidskriftsartikel (refereegranskat)abstract
    • The long-term survival of heart transplantation (HTx) recipients has increased significantly in recent years, however, the nephrotoxic adverse effects of calcineurin inhibitors (CNIs) are still a major concern. Recently, an inhibitor of mammalian target of rapamycin, everolimus (EVL), has emerged as an alternative immunosuppressant drug that may allow CM dosage reduction and thereby spare renal function. Data were collected from 20 HTx recipients who had received EVL (target trough level 3-8 ng/mL) along with a dose reduction of CNIs and/or mycophenolate mophetil (MMF) and had been followed for 1 year. Estimated glomerular filtration rate increased significantly with a reduction in the CM dosage in a dose-dependent manner (P less than 0.001, r = -0.807). Neutrophil count increased significantly (P less than 0.05) with a reduction in the dosage of MMF (P = 0.009, r = -0.671). Cytomegalovirus antigenemia remained negative after EVL administration among all candidates without any antiviral agents (P = 0.001). There were no significant increases in the acute rejection rates among recipients with EVL compared to those without EVL (P = 0.132). An immunosuppressant strategy incorporating EVL could reduce the CM and MMF dosages, which resulted in improvements in renal dysfunction and neutropenia while maintaining low rejection rates among HTx recipients.
  •  
4.
  • Imamura, Teruhiko, et al. (författare)
  • How to demonstrate the reversibility of end-organ function before implantation of left ventricular assist device in INTERMACS profile 2 patients?
  • 2012
  • Ingår i: Journal of Artificial Organs. - : Springer. - 1434-7229 .- 1619-0904. ; 15:4, s. 395-398
  • Tidskriftsartikel (refereegranskat)abstract
    • For the time being, in Japan, two recently approved implantable ventricular assist devices (VADs) are indicated only when a patient has been listed for heart transplantation or approved to be eligible for heart transplantation by in-hospital committee. The reversibility of end-organ dysfunction must be expected before VAD implantation, but it is often hard to prove during worsening clinical status. We report two patients whose end-organ dysfunction had been eventually demonstrated to be reversible by invasive procedures such as transluminal liver biopsy or transient insertion of intra-aortic balloon pumping.
  •  
5.
  • Imamura, Teruhiko, et al. (författare)
  • Novel risk scoring system with preoperative objective parameters gives a good prediction of 1-year mortality in patients with a left ventricular assist device.
  • 2012
  • Ingår i: Circulation Journal. - : Japanese Circulation Society. - 1346-9843 .- 1347-4820. ; 76:8, s. 1895-1903
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:As we have previously reported, the preoperative profile defined by INTERMACS is a good predictor for the prognosis after left ventricular assist device (LVAD) implantation, but is largely dependent on the physician's decision. Several other risk stratification systems including objective parameters (eg, Leitz-Miller, Columbia, Seattle Heart Failure Model, APACHE II) have been proposed to estimate patient's mortality after LVAD implantation.METHODS AND RESULTS:According to the preoperative data from 59 patients who received LVAD (10 implantable, 49 extracorporeal) since 2002 through 2010, we performed a logistic analysis and constructed a new scoring system (ie, the TODAI VAD score (TVAD score), assigning 8 points to serum albumin <3.2mg/dl (odds ratio [OR] 8.475), 7 points to serum total bilirubin >4.8mg/dl (OR 7.300), 6 points to left ventricular end-diastolic diameter <55mm (OR 5.917), 5 points to central venous pressure >11mmHg (OR 5.128)). The receiver-operating characteristic analysis showed that the area under the curve of our new scoring system (0.864) was significantly larger than any of the abovementioned 5 scoring methods (all P<0.05). With the TVAD score, low (0-8 points), intermediate (9-17 points), and high (18-26 points) risk strata had significantly different 1-year survival rates of 95%, 54%, and 14%, respectively (all P<0.001).CONCLUSIONS:The TVAD score can predict the prognosis after LVAD implantation much better than the previously known methods.
  •  
6.
  • Imamura, Teruhiko, et al. (författare)
  • Preoperative Levels of Bilirubin or Creatinine Adjusted by Age Can Predict Their Reversibility After Implantation of Left Ventricular Assist Device
  • 2013
  • Ingår i: Circulation Journal. - : Japanese Circulation Society. - 1346-9843 .- 1347-4820. ; 77:1, s. 96-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: It is often difficult to predict reversibility of liver or renal function after left ventricular assist device (LVAD) implantation in patients with stage D heart failure. Methods and Results: Data were obtained for 69 patients who had received a LVAD (18 continuous-flow, 51 pulsatile). Persistent hepatic or renal dysfunction was defined as levels of total bilirubin (TB) or creatinine (Cre) greater than1.5 mg/dl at 6 months after LVAD implantation. TB score or Cre score was calculated: 0.15 x age+ 1.1x (preoperative TB) or 0.2 x age + 3.6 x (preoperative Cre), in which coefficients were determined on the basis of odds ratios for persistent hepatic or renal dysfunction, respectively. Receiver-operating characteristics analyses showed good predictabilities for persistent end-organ dysfunction (area under curve: 0.794 for TB score and 0.839 for Cre score). High-risk strata of TB score (greater than11.0 points) or Cre score (greater than14.1 points) were associated with persistently higher levels of TB or Cre (TB, 1.32 +/- 0.51; Cre, 1.23 +/- 0.41 mg/dl; both Pless than0.001 vs. low-risk strata). Conclusions: Reversibility of end-organ function with LVAD implantation can be well predicted by our new risk scoring system that consists of the preoperative TB or Cre level adjusted by the patients age. The scoring system would be beneficial, especially in considering the indication of a bridge to candidacy.
  •  
7.
  • Imamura, Teruhiko, et al. (författare)
  • Successful conversion to everolimus after cytomegalovirus infection in a heart transplant recipient
  • 2012
  • Ingår i: International Heart Journal. - : International Heart Journal Association. - 1349-2365 .- 1349-3299. ; 53:3, s. 199-201
  • Tidskriftsartikel (refereegranskat)abstract
    • Cytomegalovirus (CMV) infection remains a major problem in recipients with heart transplantation (HTx), because it may play a significant role in the development of cardiac allograft vasculopathy, which is one of the major causes of death after HTx. Valganciclovir (VGC) is effective for the treatment of CM V infection, but is often associated with neutropenia, especially when used with mycophenolate mophetil (MMF). We experienced an HTx recipient with positive CMV antigenemia who suffered progressive neutropenia after administration of VGC. We switched MMF to everolimus (EVL) and assay for CM V antigenemia was constantly negative even after discontinuation of VGC. In all other 14 HTx recipients who received EVL for any reason, we found that assay for CMV antigenemia remained negative throughout the period of EVL administration. Considering the prophylactic effect on CMV, EVL can not only be an alternative to rescue from comorbidity, but might also be indicated earlier especially in CMV-seronegative HTx recipients. 
  •  
8.
  • Imamura, Teruhiko, et al. (författare)
  • Successful treatment of hemodynamic compromise caused by antibody-mediated and cellular rejection in a recipient 12 years after heart transplantation
  • 2013
  • Ingår i: International Heart Journal. - : International Heart Journal Association. - 1349-2365 .- 1349-3299. ; 54:5, s. 328-331
  • Tidskriftsartikel (refereegranskat)abstract
    • Heart transplantation (HTx) is an established therapy for stage D heart failure due to recent advances in immunosuppressive regimens. However, antibody-mediated rejection remains an unsolved problem because of its refractoriness to standard immunosuppressive therapy with high mortality and graft loss. We experienced a 16-year old patient with hemodynamic compromise caused by both cellular and antibody-mediated rejection 12 years after HTx. The rejection was refractory to repeated steroid pulse treatment, intravenous immunoglobulin administration, and intensifying immunosuppression including addition of everolimus. Eventually, she was successfully treated with repeated plasma exchange accompanied by a single administration of the anti-CD20 monoclonal antibody rituximab.
  •  
9.
  • Irnamura, Teruhiko, et al. (författare)
  • An elevated ratio of early to late diastolic filling velocity recovers after heart transplantation in a time-dependent manner
  • 2012
  • Ingår i: Journal of Cardiology. - : Elsevier. - 0914-5087 .- 1876-4738. ; 60:4, s. 295-300
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundSeveral groups have reported that an elevated ratio of early (E) to late (A) diastolic filling velocities is observed in patients after heart transplantation. However, the mechanism has not been fully analyzed.MethodsSerial echocardiography and hemodynamic study were performed in 16 patients who had received heart transplantation and had no evidence of rejection during 1 month after the operation.ResultsOn Day 1 after the surgery, E/A ratio was higher and peak velocity of A wave was lower than normal range among the patients after heart transplantation. E/A ratio and peak velocity of A wave gradually normalized during 1 moth after the surgery. Meanwhile, early mitral annular velocity and pulmonary capillary wedge pressure remained within normal range during the study period.ConclusionsLonger ischemic time during heart transplantation procedure may cause atrial stunning, but it appears to recover within 1 month. We have to be alert to misinterpretation of this “psuedo-psuedonormal” mitral inflow pattern early after transplantation.
  •  
10.
  • Perkiö Kato, Naoko, 1980-, et al. (författare)
  • Quality of Life and Influential Factors in Patients Implanted With a Left Ventricular Assist Device
  • 2015
  • Ingår i: Circulation Journal. - : JAPANESE CIRCULATION SOC. - 1346-9843 .- 1347-4820. ; 79:10, s. 2186-2192
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Improving quality of life (QOL) has become an important goal in left ventricular assist device (LVAD) therapy. We aimed (1) to assess the effect of an implantable LVAD on patients QOL, (2) to compare LVAD patients QOL to that of patients in different stages of heart failure (HF), and (3) to identify factors associated with patients QOL.Methods and Results: The QOL of 33 Japanese implantable LVAD patients was assessed using the Minnesota Living with Heart Failure Questionnaire (MLHFQ) and Short-form 8 (SF-8), before and at 3 and 6 months afterwards. After LVAD implantation, QOL significantly improved [MLHFQ, SF-8 physical component score (PCS), SF-8 mental component score (MCS), all Pless than0.05]. Implanted LVAD patients had a better QOL than extracorporeal LVAD patients (n=33, 32.1 +/- 21.9 vs. n=17, 47.6 +/- 18.2), and Stage D HF patients (n=32, 51.1 +/- 17.3), but the score was comparable to that of patients who had undergone a heart transplant (n=13). In multiple regression analyses, postoperative lower albumin concentration and right ventricular failure were independently associated with poorer PCS. Female sex and postoperative anxiety were 2 of the independent factors for poorer MCS (all Pless than0.05).Conclusions: Having an implantable LVAD improves patients QOL, which is better than that of patients with an extracorporeal LVAD. Both clinical and psychological factors are influence QOL after LVAD implantation.
  •  
11.
  • Perkiö Kato, Naoko, et al. (författare)
  • Quality of life of family caregivers of patients with a left ventricular assist device in Japan
  • 2018
  • Ingår i: Journal of Cardiology. - : ELSEVIER SCIENCE BV. - 0914-5087 .- 1876-4738. ; 71:1-2, s. 81-87
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The role of caregivers is important for the successful support of left ventricular assist device (LVAD) patients. We aimed to (1) evaluate quality of life (QoL) of caregivers pre-and post-LVAD implant and (2) identify factors associated with caregivers QoL. Methods: The caregivers QoL was assessed with the Short Form-8 before implant, at 3 and 6 months after LVAD implantation. The physical and mental component summary (PCS and MCS) scores were calculated. Caregiver burden was evaluated using the 8-item Zarit Caregiver Burden Interview. Results: Data were collected from LVAD patients as bridge-to-transplant and their family caregivers in Japan. No significant changes were found in caregivers PCS scores during the follow-up (before 52.7 +/- 7.1; at 3 months 49.7 +/- 6.5, and at 6 months 50.7 +/- 6.4, n = 20). Compared with the scores before implant (38.9 +/- 9.3), the caregivers MCS scores improved after LVAD implantation at 3 months (44.2 +/- 7.7; p = 0.03) and at 6 months (46.2 +/- 7.4, p = 0.003), but they were still lower than those of the Japanese general population (p amp;lt; 0.01). In multiple regression analysis at 3 months (n = 40), caregivers lower PCS scores were associated with older patient age [standard partial regression coefficients (s beta) = -0.36, p = 0.02] and caregiver unemployment (s beta = 0.30, p = 0.04), whereas being female (s beta = -0.26, p = 0.03), being the patients spouse (s beta = -0.23, p = 0.03), and having a mild to moderate caregiving burden (s beta = -0.63, p amp;lt; 0.001) were associated with lower MCS scores among caregivers. Conclusions: LVAD implantation improves caregivers mental QoL. Since caregivers MCS scores are lower than the general population, it is important to identify family caregivers at risk for low QoL and reduce their caregiving burden. (C) 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
  •  
12.
  • Shiga, Taro, et al. (författare)
  • Age and preoperative total bilirubin level can stratify prognosis after extracorporeal pulsatile left ventricular assist device implantation
  • 2011
  • Ingår i: Circulation Journal. - : Japanese Circulation Society. - 1346-9843 .- 1347-4820. ; 75:1, s. 121-128
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In Japan, the TOYOBO left ventricular assist device (LVAD) has been commercially available for heart failure patients as of 2010, but clinical risk stratification before implantation has not been widely performed. Methods and Results: In the present study data from 47 patients (age 38.6 +/- 14.6 [SD] years, male 74.5%, non-ischemic 74.5%) implanted with a TOYOBO LVAD between November 2002 and February 2010 were analyzed. Kaplan-Meier survival analysis showed significantly higher mortality in the patients who had cardiogenic shock preoperatively (P=0.031). Multivariate analysis revealed that the preoperative total bilirubin level (odds ratio [OR] 1.312, Pless than0.001) and age (OR 1.076, P=0.013) were independent risk factors for death. Perioperative necessity of a right ventricular assist device was also an independent risk factor for poor prognosis. Conclusions: LVAD implantation is preferable before the patient experiences hemodynamic collapse. The preoperative total bilirubin level can be used to predict prognosis after device implantation in end-stage heart failure patients.
  •  
13.
  • Shiga, Taro, et al. (författare)
  • Combination evaluation of preoperative risk indices predicts requirement of biventricular assist device
  • 2012
  • Ingår i: Circulation Journal. - : Japanese Circulation Society. - 1346-9843 .- 1347-4820. ; 76:12, s. 2785-2791
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Patients with biventricular assist device (BiVAD) placement have a poor prognosis, but preoperative risk factors for the necessity of BiVAD have not been fully elucidated.METHODS AND RESULTS:Data from 79 patients who received left ventricular assist device (LVAD) between November 2002 and December 2011 were retrospectively reviewed. Overall, 9 patients (11.4%) required BiVAD, and the survival rate of BiVAD patients was significantly lower than that of LVAD patients (P<0.001). Multivariate analysis for BiVAD requirement showed left ventricular diastolic diameter (LVDd) ≤62 mm (odds ratio [OR], 10.97; P=0.009) to be significantly associated with BiVAD requirement. Preoperative central venous pressure (CVP)/pulmonary capillary wedge pressure (PCWP) ratio ≥0.5 (OR, 13.09; P=0.028) was also significantly associated with BiVAD requirement. A new scoring system for predicting BiVAD requirement was created from the combination of CVP/PCWP ratio (≥0.5), body surface area (≤1.4 m(2)), preoperative continuous hemodiafiltration use, B-type natriuretic peptide (≥1,200 pg/ml) and LVDd (≤62 mm), and this had a significantly larger area under the curve (0.909; P=0.003) than right ventricular stroke work index on receiver operating characteristic analysis. A score >20 using the new scoring method indicated significantly high probability of BiVAD requirement (OR, 16.00; P=0.019).CONCLUSIONS:The new scoring method, which includes CVP/PCWP ratio, is a novel risk stratification tool for BiVAD therapy.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-13 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy