  • Fehmi, Janev, et al. (författare)
  • Contactin-1 links autoimmune neuropathy and membranous glomerulonephritis
  • 2023
  • Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 18:3 March
  • Tidskriftsartikel (refereegranskat)abstract
    • Membranous glomerulonephritis (MGN) is a common cause of nephrotic syndrome in adults, mediated by glomerular antibody deposition to an increasing number of newly recognised antigens. Previous case reports have suggested an association between patients with anti-contactin-1 (CNTN1)-mediated neuropathies and MGN. In an observational study we investigated the pathobiology and extent of this potential cause of MGN by examining the association of antibodies against CNTN1 with the clinical features of a cohort of 468 patients with suspected immune-mediated neuropathies, 295 with idiopathic MGN, and 256 controls. Neuronal and glomerular binding of patient IgG, serum CNTN1 antibody and protein levels, as well as immune-complex deposition were determined. We identified 15 patients with immune-mediated neuropathy and concurrent nephrotic syndrome (biopsy proven MGN in 12/12), and 4 patients with isolated MGN from an idiopathic MGN cohort, all seropositive for IgG4 CNTN1 antibodies. CNTN1-containing immune complexes were found in the renal glomeruli of patients with CNTN1 antibodies, but not in control kidneys. CNTN1 peptides were identified in glomeruli by mass spectroscopy. CNTN1 seropositive patients were largely resistant to first-line neuropathy treatments but achieved a good outcome with escalation therapies. Neurological and renal function improved in parallel with suppressed antibody titres. The reason for isolated MGN without clinical neuropathy is unclear. We show that CNTN1, found in peripheral nerves and kidney glomeruli, is a common target for autoantibody-mediated pathology and may account for between 1 and 2% of idiopathic MGN cases. Greater awareness of this cross-system syndrome should facilitate earlier diagnosis and more timely use of effective treatment.
  •  
2.
  • Petzold, Axel, et al. (författare)
  • Neurofilament ELISA validation
  • 2010
  • Ingår i: JOURNAL OF IMMUNOLOGICAL METHODS. - 0022-1759. ; 352:1-2, s. 23-31
  • Tidskriftsartikel (refereegranskat)
  •  
3.
  • Petzold, Axel, et al. (författare)
  • Neurofilament ELISA validation
  • 2010
  • Ingår i: JIM - Journal of Immunological Methods. - : Elsevier BV. - 0022-1759 .- 1872-7905. ; 352:1-2, s. 23-31
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Neurofilament proteins (Nf) are highly specific biomarkers for neuronal death and axonal degeneration. As these markers become more widely used, an inter-laboratory validation study is required to identify assay criteria for high quality performance. METHODS: The UmanDiagnostics NF-light (R)enzyme-linked immunoabsorbent assays (ELISA) for the neurofilament light chain (NfL, 68kDa) was used to test the intra-assay and inter-laboratory coefficient of variation (CV) between 35 laboratories worldwide on 15 cerebrospinal fluid (CSF) samples. Critical factors, such as sample transport and storage, analytical delays, reaction temperature and time, the laboratories' accuracy and preparation of standards were documented and used for the statistical analyses. RESULTS: The intra-laboratory CV averaged 3.3% and the inter-laboratory CV 59%. The results from the test laboratories correlated with those from the reference laboratory (R=0.60, p<0.0001). Correcting for critical factors improved the strength of the correlation. Differences in the accuracy of standard preparation were identified as the most critical factor. Correcting for the error introduced by variation in the protein standards improved the correlation to R=0.98, p<0.0001 with an averaged inter-laboratory CV of 14%. The corrected overall inter-rater agreement was subtantial (0.6) according to Fleiss' multi-rater kappa and Gwet's AC1 statistics. CONCLUSION: This multi-center validation study identified the lack of preparation of accurate and consistent protein standards as the main reason for a poor inter-laboratory CV. This issue is also relevant to other protein biomarkers based on this type of assay and will need to be solved in order to achieve an acceptable level of analytical accuracy. The raw data of this study is available online.
  •  