  • Eichenlaub, Manuel, et al. (författare)
  • Comparator Data Characteristics and Testing Procedures for the Clinical Performance Evaluation of Continuous Glucose Monitoring Systems
  • 2024
  • Ingår i: Diabetes Technology & Therapeutics. - : Mary Ann Liebert. - 1520-9156 .- 1557-8593. ; 26:4, s. 263-275
  • Tidskriftsartikel (refereegranskat)abstract
    • Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC), that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels is suggested that enables the collection of comparator data with these characteristics. This work is an important step towards establishing a future standard for the performance evaluation of CGM systems.
  •  
2.
  • Eichenlaub, Manuel, et al. (författare)
  • Continuous Glucose Deviation Interval and Variability Analysis (CG-DIVA) : A Novel Approach for the Statistical Accuracy Assessment of Continuous Glucose Monitoring Systems
  • 2022
  • Ingår i: Journal of Diabetes Science and Technology. - : Diabetes Technology Society. - 1932-2968.
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The accuracy of continuous glucose monitoring (CGM) systems is crucial for the management of glucose levels in individuals with diabetes mellitus. However, the discussion of CGM accuracy is challenged by an abundance of parameters and assessment methods. The aim of this article is to introduce the Continuous Glucose Deviation Interval and Variability Analysis (CG-DIVA), a new approach for a comprehensive characterization of CGM point accuracy which is based on the U.S. Food and Drug Administration requirements for "integrated" CGM systems.METHODS: The statistical concept of tolerance intervals and data from two approved CGM systems was used to illustrate the CG-DIVA.RESULTS: The CG-DIVA characterizes the expected range of deviations of the CGM system from a comparison method in different glucose concentration ranges and the variability of accuracy within and between sensors. The results of the CG-DIVA are visualized in an intuitive and straightforward graphical presentation. Compared with conventional accuracy characterizations, the CG-DIVA infers the expected accuracy of a CGM system and highlights important differences between CGM systems. Furthermore, it provides information on the incidence of large errors which are of particular clinical relevance. A software implementation of the CG-DIVA is freely available (https://github.com/IfDTUlm/CGM_Performance_Assessment).CONCLUSIONS: We argue that the CG-DIVA can simplify the discussion and comparison of CGM accuracy and could replace the high number of conventional approaches. Future adaptations of the approach could thus become a putative standard for the accuracy characterization of CGM systems and serve as the basis for the definition of future CGM performance requirements.
  •  
3.
  • Freckmann, Guido, et al. (författare)
  • Clinical Performance Evaluation of Continuous Glucose Monitoring Systems : A Scoping Review and Recommendations for Reporting
  • 2023
  • Ingår i: Journal of Diabetes Science and Technology. - : Sage Publications. - 1932-2968. ; 17:6, s. 1506-1526
  • Forskningsöversikt (refereegranskat)abstract
    • The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.
  •  