SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gallardo González I.) "

Sökning: WFRF:(Gallardo González I.)

  • Resultat 1-22 av 22
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brown, A. G. A., et al. (författare)
  • Gaia Data Release 1 Summary of the astrometric, photometric, and survey properties
  • 2016
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 595
  • Tidskriftsartikel (refereegranskat)abstract
    • Context. At about 1000 days after the launch of Gaia we present the first Gaia data release, Gaia DR1, consisting of astrometry and photometry for over 1 billion sources brighter than magnitude 20.7. Aims. A summary of Gaia DR1 is presented along with illustrations of the scientific quality of the data, followed by a discussion of the limitations due to the preliminary nature of this release. Methods. The raw data collected by Gaia during the first 14 months of the mission have been processed by the Gaia Data Processing and Analysis Consortium (DPAC) and turned into an astrometric and photometric catalogue. Results. Gaia DR1 consists of three components: a primary astrometric data set which contains the positions, parallaxes, and mean proper motions for about 2 million of the brightest stars in common with the HIPPARCOS and Tycho-2 catalogues - a realisation of the Tycho-Gaia Astrometric Solution (TGAS) - and a secondary astrometric data set containing the positions for an additional 1.1 billion sources. The second component is the photometric data set, consisting of mean G-band magnitudes for all sources. The G-band light curves and the characteristics of similar to 3000 Cepheid and RR Lyrae stars, observed at high cadence around the south ecliptic pole, form the third component. For the primary astrometric data set the typical uncertainty is about 0.3 mas for the positions and parallaxes, and about 1 mas yr(-1) for the proper motions. A systematic component of similar to 0.3 mas should be added to the parallax uncertainties. For the subset of similar to 94 000 HIPPARCOS stars in the primary data set, the proper motions are much more precise at about 0.06 mas yr(-1). For the secondary astrometric data set, the typical uncertainty of the positions is similar to 10 mas. The median uncertainties on the mean G-band magnitudes range from the mmag level to similar to 0.03 mag over the magnitude range 5 to 20.7. Conclusions. Gaia DR1 is an important milestone ahead of the next Gaia data release, which will feature five-parameter astrometry for all sources. Extensive validation shows that Gaia DR1 represents a major advance in the mapping of the heavens and the availability of basic stellar data that underpin observational astrophysics. Nevertheless, the very preliminary nature of this first Gaia data release does lead to a number of important limitations to the data quality which should be carefully considered before drawing conclusions from the data.
  •  
2.
  • Prusti, T., et al. (författare)
  • The Gaia mission
  • 2016
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 595
  • Tidskriftsartikel (refereegranskat)abstract
    • Gaia is a cornerstone mission in the science programme of the European Space Agency (ESA). The spacecraft construction was approved in 2006, following a study in which the original interferometric concept was changed to a direct-imaging approach. Both the spacecraft and the payload were built by European industry. The involvement of the scientific community focusses on data processing for which the international Gaia Data Processing and Analysis Consortium (DPAC) was selected in 2007. Gaia was launched on 19 December 2013 and arrived at its operating point, the second Lagrange point of the Sun-Earth-Moon system, a few weeks later. The commissioning of the spacecraft and payload was completed on 19 July 2014. The nominal five-year mission started with four weeks of special, ecliptic-pole scanning and subsequently transferred into full-sky scanning mode. We recall the scientific goals of Gaia and give a description of the as-built spacecraft that is currently (mid-2016) being operated to achieve these goals. We pay special attention to the payload module, the performance of which is closely related to the scientific performance of the mission. We provide a summary of the commissioning activities and findings, followed by a description of the routine operational mode. We summarise scientific performance estimates on the basis of in-orbit operations. Several intermediate Gaia data releases are planned and the data can be retrieved from the Gaia Archive, which is available through the Gaia home page.
  •  
3.
  • van Leeuwen, F., et al. (författare)
  • Gaia Data Release 1 : Open cluster astrometry: Performance, limitations, and future prospects
  • 2017
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 601
  • Tidskriftsartikel (refereegranskat)abstract
    • Context. The first Gaia Data Release contains the Tycho-Gaia Astrometric Solution (TGAS). This is a subset of about 2 million stars for which, besides the position and photometry, the proper motion and parallax are calculated using Hipparcos and Tycho-2 positions in 1991.25 as prior information. Aims. We investigate the scientific potential and limitations of the TGAS component by means of the astrometric data for open clusters. Methods. Mean cluster parallax and proper motion values are derived taking into account the error correlations within the astrometric solutions for individual stars, an estimate of the internal velocity dispersion in the cluster, and, where relevant, the effects of the depth of the cluster along the line of sight. Internal consistency of the TGAS data is assessed. Results. Values given for standard uncertainties are still inaccurate and may lead to unrealistic unit-weight standard deviations of least squares solutions for cluster parameters. Reconstructed mean cluster parallax and proper motion values are generally in very good agreement with earlier Hipparcos-based determination, although the Gaia mean parallax for the Pleiades is a significant exception. We have no current explanation for that discrepancy. Most clusters are observed to extend to nearly 15 pc from the cluster centre, and it will be up to future Gaia releases to establish whether those potential cluster-member stars are still dynamically bound to the clusters. Conclusions. The Gaia DR1 provides the means to examine open clusters far beyond their more easily visible cores, and can provide membership assessments based on proper motions and parallaxes. A combined HR diagram shows the same features as observed before using the Hipparcos data, with clearly increased luminosities for older A and F dwarfs.
  •  
4.
  • Clementini, G., et al. (författare)
  • Testing parallaxes with local Cepheids and RR Lyrae stars
  • 2017
  • Ingår i: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 605
  • Tidskriftsartikel (refereegranskat)abstract
    • Context. Parallaxes for 331 classical Cepheids, 31 Type II Cepheids, and 364 RR Lyrae stars in common between Gaia and the HIPPARCOS and Tycho-2 catalogues are published in Gaia Data Release 1 (DR1) as part of the Tycho-Gaia Astrometric Solution (TGAS). Aims. In order to test these first parallax measurements of the primary standard candles of the cosmological distance ladder, which involve astrometry collected by Gaia during the initial 14 months of science operation, we compared them with literature estimates and derived new period-luminosity (PL), period-Wesenheit (PW) relations for classical and Type II Cepheids and infrared PL, PL-metallicity (PLZ), and optical luminosity-metallicity (MV-[Fe/H]) relations for the RR Lyrae stars, with zero points based on TGAS.Methods. Classical Cepheids were carefully selected in order to discard known or suspected binary systems. The final sample comprises 102 fundamental mode pulsators with periods ranging from 1.68 to 51.66 days (of which 33 with sigma(omega)/omega < 0 : 5). The Type II Cepheids include a total of 26 W Virginis and BL Herculis stars spanning the period range from 1.16 to 30.00 days (of which only 7 with sigma(omega)/omega 0 : 5). The RR Lyrae stars include 200 sources with pulsation period ranging from 0.27 to 0.80 days (of which 112 with sigma(omega)/omega < 0 : 5). The new relations were computed using multi- band (V; I; J; K-s) photometry and spectroscopic metal abundances available in the literature, and by applying three alternative approaches: (i) linear least-squares fitting of the absolute magnitudes inferred from direct transformation of the TGAS parallaxes; (ii) adopting astrometry-based luminosities; and (iii) using a Bayesian fitting approach. The last two methods work in parallax space where parallaxes are used directly, thus maintaining symmetrical errors and allowing negative parallaxes to be used. The TGAS-based PL; PW; PLZ, and MV [Fe/H] relations are discussed by comparing the distance to the Large Magellanic Cloud provided by different types of pulsating stars and alternative fitting methods.Results. Good agreement is found from direct comparison of the parallaxes of RR Lyrae stars for which both TGAS and HST measurements are available. Similarly, very good agreement is found between the TGAS values and the parallaxes inferred from the absolute magnitudes of Cepheids and RR Lyrae stars analysed with the Baade-Wesselink method. TGAS values also compare favourably with the parallaxes inferred by theoretical model fitting of the multi-band light curves for two of the three classical Cepheids and one RR Lyrae star, which were analysed with this technique in our samples. The K-band PL relations show the significant improvement of the TGAS parallaxes for Cepheids and RR Lyrae stars with respect to the HIPPARCOS measurements. This is particularly true for the RR Lyrae stars for which improvement in quality and statistics is impressive.Conclusions. TGAS parallaxes bring a significant added value to the previous HIPPARCOS estimates. The relations presented in this paper represent the first Gaia-calibrated relations and form a work-in-progress milestone report in the wait for Gaia-only parallaxes of which a first solution will become available with Gaia Data Release 2 (DR2) in 2018.
  •  
5.
  • Morales, J. C., et al. (författare)
  • A giant exoplanet orbiting a very-low-mass star challenges planet formation models
  • 2019
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 365:6460, s. 1441-1445
  • Tidskriftsartikel (refereegranskat)abstract
    • Surveys have shown that super-Earth and Neptune-mass exoplanets are more frequent than gas giants around low-mass stars, as predicted by the core accretion theory of planet formation. We report the discovery of a giant planet around the very-low-mass star GJ 3512, as determined by optical and near-infrared radial-velocity observations. The planet has a minimum mass of 0.46 Jupiter masses, very high for such a small host star, and an eccentric 204-day orbit. Dynamical models show that the high eccentricity is most likely due to planet-planet interactions. We use simulations to demonstrate that the GJ 3512 planetary system challenges generally accepted formation theories, and that it puts constraints on the planet accretion and migration rates. Disk instabilities may be more efficient in forming planets than previously thought.
  •  
6.
  • Bouyoucef, S E, et al. (författare)
  • Poster Session 2 : Monday 4 May 2015, 08
  • 2015
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 16 Suppl 1
  • Tidskriftsartikel (refereegranskat)
  •  
7.
  •  
8.
  • Fomalont, E. B., et al. (författare)
  • THE 2014 ALMA LONG BASELINE CAMPAIGN: AN OVERVIEW
  • 2015
  • Ingår i: Astrophysical Journal Letters. - : American Astronomical Society. - 2041-8213 .- 2041-8205. ; 808:1
  • Tidskriftsartikel (refereegranskat)abstract
    • A major goal of the Atacama Large Millimeter/submillimeter Array (ALMA) is to make accurate images with resolutions of tens of milliarcseconds, which at submillimeter (submm) wavelengths requires baselines up to similar to 15 km. To develop and test this capability, a Long Baseline Campaign (LBC) was carried out from 2014 September to late November, culminating in end-to-end observations, calibrations, and imaging of selected Science Verification (SV) targets. This paper presents an overview of the campaign and its main results, including an investigation of the short-term coherence properties and systematic phase errors over the long baselines at the ALMA site, a summary of the SV targets and observations, and recommendations for science observing strategies at long baselines. Deep ALMA images of the quasar 3C 138 at 97 and 241 GHz are also compared to VLA 43 GHz results, demonstrating an agreement at a level of a few percent. As a result of the extensive program of LBC testing, the highly successful SV imaging at long baselines achieved angular resolutions as fine as 19 mas at similar to 350 GHz. Observing with ALMA on baselines of up to 15 km is now possible, and opens up new parameter space for submm astronomy.
  •  
9.
  • Cortina-Gil, D., et al. (författare)
  • CALIFA, a Dedicated Calorimeter for the R3B/FAIR
  • 2014
  • Ingår i: Nuclear Data Sheets. - : Elsevier BV. - 1095-9904 .- 0090-3752. ; 120, s. 99-101
  • Tidskriftsartikel (refereegranskat)abstract
    • The R3B experiment (Reactions with Relativistic Radioactive Beams) at FAIR (Facility for Antiproton and Ion Research) is a versatile setup dedicated to the study of reactions induced by high-energy radioactive beams. It will provide kinematically complete measurements with high efficiency, acceptance and resolution, making possible a broad physics program with rare-isotopes. CALIFA (CALorimeter for In-Flight detection of gamma-rays and high energy charged pArticles), is a complex detector based on scintillation crystals, that will surround the target of the R3B experiment. CALIFA will act as a total absorption gamma-calorimeter and spectrometer, as well as identifier of charged particles from target residues. This versatility is its most challenging requirement, demanding a huge dynamic range, to cover from low energy gamma-rays up to 300 MeV protons. This fact, along with the high-energy of the beams determine the conceptual design of the detector, presented in this paper, together with the technical solutions proposed for its construction.
  •  
10.
  • Abdollahi, S., et al. (författare)
  • A gamma-ray determination of the Universe's star formation history
  • 2018
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 362:6418, s. 1031-1034
  • Tidskriftsartikel (refereegranskat)abstract
    • The light emitted by all galaxies over the history of the Universe produces the extragalactic background light (EBL) at ultraviolet, optical, and infrared wavelengths. The EBL is a source of opacity for gamma rays via photon-photon interactions, leaving an imprint in the spectra of distant gamma-ray sources. We measured this attenuation using 739 active galaxies and one gamma-ray burst detected by the Fermi Large Area Telescope. This allowed us to reconstruct the evolution of the EBL and determine the star formation history of the Universe over 90% of cosmic time. Our star formation history is consistent with independent measurements from galaxy surveys, peaking at redshift z similar to 2. Upper limits of the EBL at the epoch of reionization suggest a turnover in the abundance of faint galaxies at z similar to 6.
  •  
11.
  • Šmíd, M., et al. (författare)
  • Highly efficient angularly resolving x-ray spectrometer optimized for absorption measurements with collimated sources
  • 2017
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 88:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Highly collimated betatron radiation from a laser wakefield accelerator is a promising tool for spectroscopic measurements. Therefore, there is a requirement to create spectrometers suited to the unique properties of such a source. We demonstrate a spectrometer which achieves an energy resolution of <5 eV at 9 keV (E/Delta;E>1800) and is angularly resolving the x-ray emission allowing the reference and spectrum to be recorded at the same time. The single photon analysis is used to significantly reduce the background noise. Theoretical performance of various configurations of the spectrometer is calculated by a ray-tracing algorithm. The properties and performance of the spectrometer including the angular and spectral resolution are demonstrated experimentally on absorption above the K-edge of a Cu foil backlit by a laser-produced betatron radiation x-ray beam.
  •  
12.
  • Audet, T. L., et al. (författare)
  • Electron injector for compact staged high energy accelerator
  • 2016
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 829, s. 304-308
  • Tidskriftsartikel (refereegranskat)abstract
    • An electron injector for multi-stage laser wakefield experiments is presented. It consists of a variable length gas cell of small longitudinal dimension (⩽10mm). The gas filling process in this cell was characterized both experimentally and with fluid simulation. Electron acceleration experiments were performed at two different laser facilities. Results show low divergence and low pointing fluctuation electron bunches suitable for transport to a second stage, and a peaked energy distribution suitable for injection into the second stage wakefield accelerator.
  •  
13.
  • Audet, T. L., et al. (författare)
  • Investigation of ionization-induced electron injection in a wakefield driven by laser inside a gas cell
  • 2016
  • Ingår i: Physics of Plasmas. - : AIP Publishing. - 1070-664X .- 1089-7674. ; 23:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Ionization-induced electron injection was investigated experimentally by focusing a driving laser pulse with a maximum normalized potential of 1.2 at different positions along the plasma density profile inside a gas cell, filled with a gas mixture composed of 99%H2+1%N2. Changing the laser focus position relative to the gas cell entrance controls the accelerated electron bunch properties, such as the spectrum width, maximum energy, and accelerated charge. Simulations performed using the 3D particle-in-cell code WARP with a realistic density profile give results that are in good agreement with the experimental ones. The interest of this regime for optimizing the bunch charge in a selected energy window is discussed.
  •  
14.
  • Cortina-Gil, D., et al. (författare)
  • CALIFA, a Dedicated Calorimeter for the (RB)-B-3/FAIR
  • 2014
  • Ingår i: Nuclear Data Sheets. - : Elsevier BV. - 0090-3752. ; 120, s. 99-101
  • Tidskriftsartikel (refereegranskat)abstract
    • The (RB)-B-3 experiment (Reactions with Relativistic Radioactive Beams) at FAIR (Facility for Antiproton and Ion Research) is a versatile setup dedicated to the study of reactions induced by high-energy radioactive beams. It will provide kinematically complete measurements with high efficiency, acceptance and resolution, making possible a broad physics program with rare-isotopes. CALIFA (CALorimeter for In-Flight detection of gamma-rays and high energy charged pArticles), is a complex detector based on scintillation crystals, that will surround the target of the (RB)-B-3 experiment. CALIFA will act as a total absorption gamma-calorimeter and spectrometer, as well as identifier of charged particles from target residues. This versatility is its most challenging requirement, demanding a huge dynamic range, to cover from low energy gamma-rays up to 300 MeV protons. This fact, along with the high-energy of the beams determine the conceptual design of the detector, presented in this paper, together with the technical solutions proposed for its construction.
  •  
15.
  • Gallardo González, I., et al. (författare)
  • Effects of the dopant concentration in laser wakefield and direct laser acceleration of electrons
  • 2018
  • Ingår i: New Journal of Physics. - : IOP Publishing. - 1367-2630. ; 20:5
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, we experimentally study the effects of the nitrogen concentration in laser wakefield acceleration of electrons in a gas mixture of hydrogen and nitrogen. A 15 TW peak power laser pulse is focused to ionize the gas, excite a plasma wave and accelerate electrons up to 230 MeV. We find that at dopant concentrations above 2% the total divergence of the electrons is increased and the high energy electrons are emitted preferentially with an angle of ±6 mrad, leading to a forked spatio-spectral distribution associated to direct laser acceleration (DLA). However, electrons can gain more energy and have a divergence lower than 4 mrad for concentrations below 0.5% and the same laser and plasma conditions. Particle-in-cell simulations show that for dopant concentrations above 2%, the amount of trapped charge is large enough to significantly perturb the plasma wave, reducing the amplitude of the longitudinal wakefield and suppressing other trapping mechanisms. At high concentrations the number of trapped electrons overlapping with the laser fields is increased, which rises the amount of charge affected by DLA. We conclude that the dopant concentration affects the quantity of electrons that experience significant DLA and the beam loading of the plasma wave driven by the laser pulse. These two mechanisms influence the electrons final energy, and thus the dopant concentration should be considered as a factor for the optimization of the electron beam parameters.
  •  
16.
  • Giuffrida, L., et al. (författare)
  • Manipulation of laser-accelerated proton beam profiles by nanostructured and microstructured targets
  • 2017
  • Ingår i: Physical Review Accelerators and Beams. - 2469-9888. ; 20:8, s. 081301-
  • Tidskriftsartikel (refereegranskat)abstract
    • Nanostructured and microstructured thin foils have been fabricated and used experimentally as targets to manipulate the spatial profile of proton bunches accelerated through the interaction with high intensity laser pulses (6 x 1019 W/cm(2)). Monolayers of polystyrene nanospheres were placed on the rear surfaces of thin plastic targets to improve the spatial homogeneity of the accelerated proton beams. Moreover, thin targets with grating structures of various configurations on their rear sides were used tomodify the proton beam divergence. Experimental results are presented, discussed, and supported by 3D particle-in-cell numerical simulations.
  •  
17.
  • Giuffrida, L., et al. (författare)
  • Nano and micro structured targets to modulate the spatial profile of laser driven proton beams
  • 2017
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 12:3, s. article no C03040 -
  • Tidskriftsartikel (refereegranskat)abstract
    • Nano and micro structured thin (μ m-scale) foils were designed, fabricated and irradiated with the high intensity laser system operating at LLC (Lund Laser Centre, Sweden) in order to systematically study and improve the main proton beam parameters. Nano-spheres deposited on the front (laser irradiated) surface of a flat Mylar foil enabled a small enhancement of the maximum energy and number of the accelerated protons. Nano-spheres on the rear side allowed to modify the proton beam spatial profile. In particular, with nanospheres deposited on the rear of the target, the proton beam spatial homogeneity was clearly enhanced. Silicon nitride thin foils having micro grating structures (with different step dimensions) on the rear surface were also used as targets to influence the divergence of the proton beam and drastically change its shape through a sort of stretching effect. The target fabrication process used for the different target types is described, and representative experimental results are shown and discussed along with supporting 3D particle-in-cell simulations. © 2017 IOP Publishing Ltd and Sissa Medialab srl.
  •  
18.
  • Hansson, M., et al. (författare)
  • Localization of ionization-induced trapping in a laser wakefield accelerator using a density down-ramp
  • 2016
  • Ingår i: Plasma Physics and Controlled Fusion. - : IOP Publishing. - 0741-3335 .- 1361-6587. ; 58:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on a study on controlled trapping of electrons, by field ionization of nitrogen ions, in laser wakefield accelerators in variable length gas cells. In addition to ionization-induced trapping in the density plateau inside the cells, which results in wide, but stable, electron energy spectra, a regime of ionization-induced trapping localized in the density down-ramp at the exit of the gas cells, is found. The resulting electron energy spectra are peaked, with 10% shot-to-shot fluctuations in peak energy. Ionization-induced trapping of electrons in the density down-ramp is a way to trap and accelerate a large number of electrons, thus improving the efficiency of the laser-driven wakefield acceleration.
  •  
19.
  • Hussein, A. E., et al. (författare)
  • Laser-wakefield accelerators for high-resolution X-ray imaging of complex microstructures
  • 2019
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 9:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Laser-wakefield accelerators (LWFAs) are high acceleration-gradient plasma-based particle accelerators capable of producing ultra-relativistic electron beams. Within the strong focusing fields of the wakefield, accelerated electrons undergo betatron oscillations, emitting a bright pulse of X-rays with a micrometer-scale source size that may be used for imaging applications. Non-destructive X-ray phase contrast imaging and tomography of heterogeneous materials can provide insight into their processing, structure, and performance. To demonstrate the imaging capability of X-rays from an LWFA we have examined an irregular eutectic in the aluminum-silicon (Al-Si) system. The lamellar spacing of the Al-Si eutectic microstructure is on the order of a few micrometers, thus requiring high spatial resolution. We present comparisons between the sharpness and spatial resolution in phase contrast images of this eutectic alloy obtained via X-ray phase contrast imaging at the Swiss Light Source (SLS) synchrotron and X-ray projection microscopy via an LWFA source. An upper bound on the resolving power of 2.7 ± 0.3 μm of the LWFA source in this experiment was measured. These results indicate that betatron X-rays from laser wakefield acceleration can provide an alternative to conventional synchrotron sources for high resolution imaging of eutectics and, more broadly, complex microstructures.
  •  
20.
  • Kettle, B., et al. (författare)
  • Single-Shot Multi-keV X-Ray Absorption Spectroscopy Using an Ultrashort Laser-Wakefield Accelerator Source
  • 2019
  • Ingår i: Physical Review Letters. - 0031-9007. ; 123:25
  • Tidskriftsartikel (refereegranskat)abstract
    • Single-shot absorption measurements have been performed using the multi-keV x rays generated by a laser-wakefield accelerator. A 200 TW laser was used to drive a laser-wakefield accelerator in a mode which produced broadband electron beams with a maximum energy above 1 GeV and a broad divergence of ≈15 mrad FWHM. Betatron oscillations of these electrons generated 1.2±0.2×106 photons/eV in the 5 keV region, with a signal-to-noise ratio of approximately 300 1. This was sufficient to allow high-resolution x-ray absorption near-edge structure measurements at the K edge of a titanium sample in a single shot. We demonstrate that this source is capable of single-shot, simultaneous measurements of both the electron and ion distributions in matter heated to eV temperatures by comparison with density functional theory simulations. The unique combination of a high-flux, large bandwidth, few femtosecond duration x-ray pulse synchronized to a high-power laser will enable key advances in the study of ultrafast energetic processes such as electron-ion equilibration.
  •  
21.
  • Macias Garcia, B, et al. (författare)
  • Toxicity of glycerol for the stallion spermatozoa: Effects on membrane integrity and cytoskeleton, lipid peroxidation and mitochondrial membrane potential
  • 2012
  • Ingår i: Theriogenology. - : Elsevier. - 0093-691X .- 1879-3231. ; 77:7, s. 1280-1289
  • Tidskriftsartikel (refereegranskat)abstract
    • Glycerol is, to date, the most widely used cryoprotectant to freeze stallion spermatozoa at concentrations between 2% and 5%. Cryoprotectant toxicity has been claimed to be the single most limiting factor for the success of cryopreservation. In order to evaluate the toxic effects of the concentrations of glycerol used in practice, stallion spermatozoa were incubated in Biggers Whitten and Whittingham (BWW) media supplemented with 0%, 0.5%, 1.5%, 2.5%, 3.5%, and 5% glycerol. In two additional experiments, a hyposmotic (75 mOsm/kg) and a hyperosmotic (900 mOsm/kg) control media were included. Sperm parameters evaluated included cell volume, membrane integrity, lipid peroxidation, caspase 3, 7, and 8 activation, mitochondrial membrane potential, and integrity of the cytoskeleton. Glycerol exerted toxicity at concentrations 3.5% and the maximal toxicity was observed at 5%. The actin cytoskeleton was especially sensitive to glycerol presence, inducing rapid F actin depolymerization at concentrations over 1.5%. The sperm membrane and the mitochondria were other structures affected. The toxicity of glycerol is apparently related to osmotic and nonosmotic effects. In view of our results the concentration of glycerol in the freezing media for stallion spermatozoa should not surpass 2.5%.
  •  
22.
  • Streeter, M. J.V., et al. (författare)
  • Characterization of laser wakefield acceleration efficiency with octave spanning near-IR spectrum measurements
  • 2022
  • Ingår i: Physical Review Accelerators and Beams. - 2469-9888. ; 25:10
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield and from the plasma to the accelerated electron beam was diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximized at 19±3% by tuning the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimization of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-22 av 22

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy