SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gleisner M.) "

Sökning: WFRF:(Gleisner M.)

  • Resultat 1-22 av 22
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Tran-Gia, Johannes, et al. (författare)
  • On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration : a European multi-centre evaluation
  • 2023
  • Ingår i: EJNMMI Physics. - 2197-7364. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. Materials and methods: Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68–107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. Results: As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12–1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. Conclusion: This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.
  •  
2.
  •  
3.
  •  
4.
  • Gleisner, M., et al. (författare)
  • Comparison of sulfide oxidation in unweathered pyretic mine tailings
  • 2003
  • Ingår i: Proc. ICARD 2003, 6th Int. Conf. on Acid Rock Drainage, Cairns, Australia, July 14 – 17, 2003. ; , s. 1027-1030
  • Konferensbidrag (refereegranskat)abstract
    • The study focuses on sulfide oxidation processes in unweathered pyrite-rich mine tailings from a soil-covered impoundment in northern Sweden. To simulate the oxygen-limited conditions in water saturated tailings two long-term column experiments were performed. Results are presented for the first 11 months of the experiments at room temperature. The tailings used in the experiments were of two different grain sizes (one coarse grained, in the range 0.02 - 0.6 mm with a grain surface area of 1.86 m2 g-1, and one fine-grained, in the range 0.0015 - 0.06 mm with a grain surface area of 10.00 m2 g-1) and with slightly different mineralogical composition. The S:Fe molar ratio in the leachates (1.0 - 1.5) indicates either that pyrrhotite is the main iron sulfide undergoing oxidation in our experiments, or, alternatively that the S:Fe molar ratio in the leachate is determined by pyrite weathering in conjunction with other processes releasing iron or immobilising sulfate. However, speciation modelling of the leachates indicates that ferrihydrite was close to saturation, suggesting that a ferric oxyhydroxide may have dissolved/ precipitated during the experimental period, thereby affecting the S:Fe molar ratio. Pyrite oxidation rates obtained from the two column experiments during ‘steady-state’ were 2.25 × 10-13 and 8.45 × 10-14 mol m-2 s-1 in the coarse and fine tailings, respectively. Pyrrhotite oxidation rates, as an alternative, were 2.31 × 10-12 and 1.24 × 10-11 mol m-2 s-1 in the coarse and fine tailings, respectively. Natural microbial activity was confirmed in both the tailings and the leachates; therefore, the obtained oxidation rates are not strictly abiotic. It is thus concluded, based on the experimental results, that tailing heterogeneity will result in zones with different oxidation rates, related to their physical and chemical properties.
  •  
5.
  • Sjögreen Gleisner, Katarina, et al. (författare)
  • EANM dosimetry committee recommendations for dosimetry of 177Lu-labelled somatostatin-receptor- and PSMA-targeting ligands
  • 2022
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 49, s. 1778-1809
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of the EANM Dosimetry Committee is to provide recommendations and guidance to scientists and clinicians on patient-specific dosimetry. Radiopharmaceuticals labelled with lutetium-177 (177Lu) are increasingly used for therapeutic applications, in particular for the treatment of metastatic neuroendocrine tumours using ligands for somatostatin receptors and prostate adenocarcinoma with small-molecule PSMA-targeting ligands. This paper provides an overview of reported dosimetry data for these therapies and summarises current knowledge about radiation-induced side effects on normal tissues and dose-effect relationships for tumours. Dosimetry methods and data are summarised for kidneys, bone marrow, salivary glands, lacrimal glands, pituitary glands, tumours, and the skin in case of radiopharmaceutical extravasation. Where applicable, taking into account the present status of the field and recent evidence in the literature, guidance is provided. The purpose of these recommendations is to encourage the practice of patient-specific dosimetry in therapy with 177Lu-labelled compounds. The proposed methods should be within the scope of centres offering therapy with 177Lu-labelled ligands for somatostatin receptors or small-molecule PSMA.
  •  
6.
  • Torres, A, et al. (författare)
  • Haptoglobin Induces a Specific Proteomic Profile and a Mature-Associated Phenotype on Primary Human Monocyte-Derived Dendritic Cells
  • 2022
  • Ingår i: International journal of molecular sciences. - : MDPI AG. - 1422-0067. ; 23:13
  • Tidskriftsartikel (refereegranskat)abstract
    • Damage-associated molecular patterns (DAMPs) play a critical role in dendritic cells (DCs) ability to trigger a specific and efficient adaptive immune response for different physiological and pathological scenarios. We have previously identified constitutive DAMPs (HMGB1 and Calreticulin) as well as new putative inducible DAMPs such as Haptoglobin (HP), from a therapeutically used heat shock-conditioned melanoma cell lysate (called TRIMEL). Remarkably, HP was shown to be the most abundant protein in the proteomic profile of heat shock-conditioned TRIMEL samples. However, its relative contribution to the observed DCs phenotype has not been fully elucidated. Human DCs were generated from monocytes isolated from PBMC of melanoma patients and healthy donors. DC lineage was induced with rhIL-4 and rhGM-CSF. After additional stimulation with HP, the proteome of these HP-stimulated cells was characterized. In addition, DCs were phenotypically characterized by flow cytometry for canonical maturation markers and cytokine production. Finally, in vitro transmigration capacity was assessed using Transwell plates. Our results showed that the stimulation with HP was associated with the presence of exclusive and higher relative abundance of specific immune-; energy production-; lipid biosynthesis-; and DAMPs-related proteins. Importantly, HP stimulation enhanced the expression of specific DC maturation markers and pro-inflammatory and Th1-associated cytokines, and an in vitro transmigration of primary human DCs. Taken together, these data suggest that HP can be considered as a new inducible DAMP with an important role in in vitro DC activation for cancer immunotherapy.
  •  
7.
  • Tran-Gia, Johannes, et al. (författare)
  • A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project
  • 2021
  • Ingår i: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time–activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative 177Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise. Methods: The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities. Results: Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla. Conclusion: This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
  •  
8.
  •  
9.
  •  
10.
  •  
11.
  • Chiesa, C., et al. (författare)
  • EANM dosimetry committee series on standard operational procedures: a unified methodology for Tc-99m-MAA pre- and Y-90 peri-therapy dosimetry in liver radioembolization with Y-90 microspheres
  • 2021
  • Ingår i: Ejnmmi Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in Y-90 microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient-relative calibration method for activity quantification.The identity of Tc-99m albumin macro-aggregates (MAA) and Y-90 microsphere biodistribution is also assumed. The large observed discrepancies in some patients between Tc-99m-MAA predictions and actual Y-90 microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected Tc-99m-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and Y-90 TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected Tc-99m-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative Y-90 bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time.
  •  
12.
  • Darudi, Ahmad, et al. (författare)
  • The Robotic Earthshine Telescope
  • 2010
  • Ingår i: Proceedings of the SPIE. - : SPIE. - 1996-756X .- 0277-786X. ; 7733, s. 8-77332
  • Konferensbidrag (refereegranskat)abstract
    • Lund Observatory is presently designing and constructing a robotic telescope dedicated to studies of the Earth's albedo by measuring the ratio between the intensity of the dark and bright sides of the Moon. The telescope will operate both in broadband and narrow-band modes over the entire visible wavelength range and will transmit observational results back to the operation team over the Internet. Design challenges, in particular related to choice of CCD and stray light suppression, are described, together with the design of the optics, control system, and enclosure. Finally we present results from laboratory tests. The telescope will go into operation in the first half of 2011.
  •  
13.
  •  
14.
  • Gleisner, M., et al. (författare)
  • Sulfide mineral oxidation in freshly processed tailings : batch experiments
  • 2002
  • Ingår i: Journal of Geochemical Exploration. - 0375-6742 .- 1879-1689. ; 76:3, s. 139-153
  • Tidskriftsartikel (refereegranskat)abstract
    • This work focuses on sulfide mineral oxidation rates under oxic conditions in freshly processed pyrite-rich tailings from the ore concentrator in Boliden, northern Sweden. Freshly processed tailings are chemically treated in the plant to kill bacteria and to obtain increased metal yields, resulting in a high pH level of 10-12 in the process water. Different oxidation experiments (abiotic oxidation in untreated tailings, acid abiotic oxidation and acid microbial oxidation), containing the Boliden tailings, were performed at room temperature with dissolved oxygen (0.21 atm O-2) for 3 months. The different pyrite oxidation rates given from the study were 2.4 x 10(-10) mol m(-2) s(-1) for the microbial, 5.9 x 10(-11) mol m(-2) s(-1) for the acidic abiotic and 3.6 x 10(-11) mol m(-2) s(-1) for the untreated experiments. Because of the potential precipitation of gypsum in the batch solutions, these oxidation rates are considered minimum values. The release rates for copper and zinc from chalcopyrite and sphalerite in the acid experiments were also investigated. These rates were normalized to the metal concentration in the tailings, and then compared to the release rate for iron from pyrite. These normalized results indicated that metal release decreased in the order Cu>Zn>Fe, demonstrating that pyrite is more resistant to oxidation than sphalerite and chalcopyrite. Pyrite was also more resistant to acidic dissolution than to microbial dissolution, while a significant fraction of sphalerite and chalcopyrite dissolved in the acid abiotic solutions.
  •  
15.
  • Hagmarker, Linn, et al. (författare)
  • Bone Marrow Absorbed Doses and Correlations with Hematologic Response During Lu-177-DOTATATE Treatments Are Influenced by Image-Based Dosimetry Method and Presence of Skeletal Metastases
  • 2019
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 2159-662X. ; 60:10, s. 1406-1413
  • Tidskriftsartikel (refereegranskat)abstract
    • This study aimed to compare different image-based methods for bone marrow dosimetry and study the dose-response relationship during treatment with Lu-177-DOTATATE in patients with and without skeletal metastases. Methods: This study included 46 patients with advanced neuroendocrine tumors treated with at least 2 fractions of Lu-177-DOTATATE at Sahlgrenska University Hospital. High- and low-uptake compartments were automatically outlined in planar images collected at 2, 24, 48, and 168 h after injection. The bone marrow absorbed doses were calculated from the cross doses of the high- and low-uptake compartments and the self-dose, using the time-activity concentration curve for the low-uptake compartment. This time-activity concentration curve was adjusted using a fixed constant of 1.8 for the planar dosimetry method and using the activity concentrations in vertebral bodies in SPECT images at 24 h after injection of Lu-177-DOTATATE in 4 hybrid methods: L4-SPECT used the activity concentration in the L4 vertebra, whereas V-SPECT, L-SPECT, and T-SPECT used the median activity concentration in all visible vertebrae, lumbar vertebrae, and thoracic vertebrae, respectively. Results: Using the planar method, L4-SPECT, V-SPECT, L-SPECT, and T-SPECT, the estimated median bone marrow absorbed doses were 0.19, 0.36, 0.40, 0.39, and 0.46 Gy/7.4 GBq, respectively, with respective ranges of 0.12-0.33, 0.15-1.44, 0.19-1.71, 0.21-1.60, and 0.18-2.12 Gy/7.4 GBq. For all methods, the bone marrow absorbed dose significantly correlated with decreased platelet counts. This correlation increased after treatment fraction 2: the Spearman correlation (r(s)) were -0.49 for the planar method, -0.61 for L4-SPECT, -0.63 for V-SPECT, -0.63 for L-SPECT, and -0.57 for T-SPECT. A separate analysis revealed an increased correlation for patients without skeletal metastases using the planar method (r(s) = -0.67). In contrast, hybrid methods had poor correlations for patients without metastases and stronger correlations for patients with skeletal metastases (r(s) = -0.61 to -0.74). The mean bone marrow absorbed doses were 3%-69% higher for patients with skeletal metastases than for patients without. Conclusion: The estimated bone marrow absorbed doses by image-based techniques and the correlation with platelets are influenced by the choice of measured vertebrae and the presence of skeletal metastases.
  •  
16.
  • Ljungberg, M., et al. (författare)
  • 3-D Image-Based Dosimetry in Radionuclide Therapy
  • 2018
  • Ingår i: IEEE Transactions on Radiation and Plasma Medical Sciences. - 2469-7311. ; 2:6, s. 527-540
  • Forskningsöversikt (refereegranskat)abstract
    • Radionuclide therapy is the use of radioactive drugs for internal radiotherapy, mainly for the treatment of metastatic disease. As opposed to systemic cancer therapies in general, the use of radioactively labeled drugs results not only in a targeted therapy but also the possibility of imaging the distribution of the drug during therapy. From such images, the absorbed doses delivered to tumors and organs at risk can be calculated. Calculation of the absorbed dose from 3-D images such as single-photon emission computed tomography (SPECT)/CT, and in some cases positron emission tomography (PET)/CT, relies on image-based activity quantification. Quantification is accomplished by modeling the physics involved in the image-formation process, and applying image-processing methods. From a time-sequence of such quantitative images, the absorbed doses are then calculated. Although individual-patient dosimetry is a standard component of other forms of radiotherapy, it is still overlooked in the majority of radionuclide therapies. In this review, we summarize the physical and technical problems that need to be addressed in image-based dosimetry. The focus is on SPECT, since most of the radionuclides used are single-photon emitters, although the use of PET is also discussed. Practical issues of relevance for the practical implementation of personalized dosimetry in radionuclide therapy are also highlighted.
  •  
17.
  • Malmström, Maria E., et al. (författare)
  • Element discharge from pyritic mine tailings at limited oxygen availability in column experiments
  • 2006
  • Ingår i: Applied Geochemistry. - : Elsevier BV. - 0883-2927 .- 1872-9134. ; 21:1, s. 184-202
  • Tidskriftsartikel (refereegranskat)abstract
    • Sulfide mineral oxidation in mine tailings deposits poses a long term threat to surrounding ground water and surface waters. Soil or water cover remediation aims at reducing the rate of sulfide mineral oxidation by decreasing the 02 ingress rate. In this study, the authors addressed the rate of sulfide oxidation and pH buffering in -33 months long, well-controlled laboratory studies of water saturated columns of sulfidic mine tailings from the Kristineberg site in Sweden at reduced O-2 availability. The element discharge rates slowly declined towards a quasi-steady state over hundreds of days. Non-reactive tracer tests showed an anomalously large dispersion, indicating strong flow heterogeneity, possibly including preferential flow and/or stagnant water zones. Congruent dissolution of pyrite and sphalerite by injected oxidants (dissolved O-2 and Fe(III)) adequately explained the discharge rate of Fe, S and Zn at quasi-steady state. Arsenic, Pb and Cu were partly retained in the tailings. Base cation discharge rates, and thus pH buffering, were apparently controlled by the rate of acidity production, with actual pH levels, available mineral surface area, and water residence times being of less importance.
  •  
18.
  •  
19.
  • Stenberg Gleisner, Anna Klara, et al. (författare)
  • Towards safety and autonomy in the home bathroom : Identifying challenges, needs and gaps
  • 2022
  • Ingår i: Applied Ergonomics. - : Elsevier. - 0003-6870 .- 1872-9126. ; 105
  • Forskningsöversikt (refereegranskat)abstract
    • This qualitative study aims to identify challenges, needs and gaps for home care bathroom tasks and gather information that will allow for user-centered, sustainable solutions for home care in the bathroom. Twenty-one interviews were carried out with participants with the perspective of client, health care worker or care orga-nization. The data were analyzed using qualitative content analysis and interpretive description. The findings identify important factors for enabling both independent living for clients and a sustainable work environment for the health care workers. They include adequate space, access to assistive devices and regular risk assessments to recognize changing needs. Enabling independent living is one strategy that can be used to manage the ongoing demographic change as well as the expected future labor shortage in the care sector. Changes can be made in the physical environment (the residential bathroom) in order to facilitate safer task performance for both the clients and the health care workers.
  •  
20.
  •  
21.
  •  
22.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-22 av 22
Typ av publikation
tidskriftsartikel (15)
konferensbidrag (3)
rapport (2)
forskningsöversikt (2)
Typ av innehåll
refereegranskat (19)
övrigt vetenskapligt/konstnärligt (2)
populärvet., debatt m.m. (1)
Författare/redaktör
Gleisner, M. (6)
Bernhardt, Peter, 19 ... (4)
Sjögreen Gleisner, K ... (4)
Strigari, L. (3)
Tittarelli, A (3)
Ljungberg, M (3)
visa fler...
Chiesa, C. (3)
Ljungberg, Michael (2)
Konijnenberg, M. (2)
Svensson, Johanna (2)
Lassmann, M (2)
Lassmann, Michael (2)
Chouin, Nicolas (2)
Bardies, M. (2)
Navarro, G. (1)
Vidal, M. (1)
Cremonesi, M. (1)
Wängberg, Bo, 1953 (1)
Rydén, Tobias (1)
Achour, A (1)
Torres, A (1)
Alsberg, T (1)
Alsberg, (1)
Visser, E. (1)
Strand, Sven-Erik (1)
Ohlsson, T. (1)
Forssell-Aronsson, E ... (1)
Darudi, Ahmad (1)
Kärsrud, (1)
Broms, S. (1)
Kärsrud, A (1)
Andersen, Torben (1)
Owner-Petersen, Mett ... (1)
Gilmozzi, Roberto (1)
Tennvall, Jan (1)
Malmström, Maria E. (1)
Zubarev, RA (1)
Sjögren, Hans Olov (1)
Gjertsson, P. (1)
Bergqvist, A (1)
Tennvall, J (1)
Chernobrovkin, A. (1)
Isaksson, M (1)
Chen, Jianing (1)
Trask, Catherine M. (1)
Chouin, N. (1)
Sundlöv, Anna (1)
Thejll, Peter (1)
Ljunggren, Kaj (1)
Garkavij, Michael (1)
visa färre...
Lärosäte
Lunds universitet (10)
Göteborgs universitet (4)
Karolinska Institutet (4)
Uppsala universitet (3)
Kungliga Tekniska Högskolan (2)
Stockholms universitet (2)
Språk
Engelska (20)
Svenska (2)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (10)
Medicin och hälsovetenskap (10)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy