SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gomez L Ana Maria 1993 ) "

Sökning: WFRF:(Gomez L Ana Maria 1993 )

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gomez L, Ana Maria, 1993-, et al. (författare)
  • Determination of the Plasma Delay Time in PIPS detectors for fission fragments at the LOHENGRIN spectrometer
  • 2023
  • Ingår i: 15<sup>th</sup> International Conference on Nuclear Data for Science and Technology (ND2022). - : EDP Sciences.
  • Konferensbidrag (refereegranskat)abstract
    • The VElocity foR Direct particle Identification spectrometer (VERDI) is a 2E-2v fission spectrometer that allows the measurement of the total mass distribution of secondary fission fragments with a resolving power of 1-2 u. It consists of two time-of-flight (ToF) arms, with one Micro Channel Plate (MCP) detector and up to 32 Silicon PIPS (Passive Implanted Planar Silicon) detectors per arm. The MCPs provide the start timing signals and the PIPS detectors provide both the energy and the stopping ToF signals. In real conditions, the PIPS signals are affected by the formation of plasma from the interaction between the heavy ions and the detector material. The plasma contributes to a reduction in signal amplitude, resulting in a Pulse Height Defect (PHD), and introduces a signal delay, known as Plasma Delay Time (PDT). An experiment to characterize the PDT and PHD was performed at the LOHENGRIN recoil separator of the Institut Laue Langevin (ILL). Characteristic fission fragments from the 239Pu(n,f) reaction were separated based on their A/Q and E/Q ratios, allowing the measurement of a wide range of energies from 21 to 110 MeV and masses between 80 and 149 u. Six PIPS detectors were characterized to study their individual responses to the PDT and PHD effects. The signals were recorded in a digital acquisition system to completely exploit the offline analysis capabilities. Achieved combined timing and energy resolutions for fission fragments varied between 72(2) ps and 100(4) ps and 1.4% - 2% (FWHM), respectively. Preliminary PHD and PDT data are presented from the masses A=85, 95, 130 and 143. The PHD trends are strongly correlated with both the ion energy and mass. The PDT, on the other hand, shows a strong variation as a function of the ion kinetic energy but a smaller dependence on the ion mass.
  •  
2.
  • Gomez L, Ana Maria, 1993- (författare)
  • Simulations And Experiments Of Plasma-Induced Effects In Silicon Detectors
  • 2023
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • When an atomic nucleus undergoes fission, two fragments with different mass and kinetic energy are emitted. The highly unstable fission fragments (FFs) evaporate prompt neutrons soon after the nucleus splits. A precise measurement of both, the mass yield distribution of the FFs and the average prompt neutron emission, $\bar{\nu}$, is important not only for current nuclear technologies but also for the development of future technologies such as Generation IV nuclear power plants. Moreover, the experimental determination of the mass yield distributions, both pre- and post-neutron emission, is valuable for testing fission models. Additionally, a precise measurement of the average neutron multiplicity as a function of the FFs mass, , is crucial in the understanding of how the excitation energy is shared between nascent FFs. The VElocity foR DIrect particle identification spectrometer (VERDI) is designed to achieve pre- and post-fission mass distributions with resolutions between 1-2 u. VERDI is a double-energy double-velocity instrument that consists of two arms. On each arm is operated one Microchannel Plate detector (MCP) for the collection of the FFs start time and up to 32 Passive Implanted Planar Silicon (PIPS) detectors for the stop time and energy detection of the FFs. However, challenges in the experimental measurements with VERDI arise due to the high degree of ionization (plasma) in the detector material from the interaction with the FFs. The plasma causes a delay in the charge carriers' migration for the signal start, known as the plasma delay time effect (PDT). Furthermore, the recombination of charge carriers in the plasma causes a shrinking in the signal's height, known as pulse height defect (PHD). This phenomenon leads to inaccuracies in the measurement of FFs mass distributions and increased systematic uncertainties. Previous studies on PDT and PHD have shown varying behaviors across different detector types, which motivated dedicated studies in the type of PIPS detectors used in VERDI. An experimental campaign to characterize the PDT and PHD in PIPS detectors was conducted in the LOHENGRIN recoil separator, which is part of the ILL nuclear facility in Grenoble, France. Measurements of FFs in a range of masses between 80 u and 149 u, with energies between 20 MeV to 110 MeV, were taken to fully characterize six PIPS detectors. The resulting PDT and PHD values were 1 ns to 4 ns and 2 MeV to 10 MeV respectively. The PDT and PHD exhibited consistent energy and mass dependencies across the detectors, which enables the possibility of an event-by-event correction of VERDI data. In this thesis, the basis for discussing the results of the studies of the PDT and PHD effects will be presented.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy