SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Halliwell David) "

Sökning: WFRF:(Halliwell David)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adcox, K, et al. (författare)
  • PHENIX detector overview
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Rubertsson, Sten, et al. (författare)
  • Mechanical chest compressions and simultanous defibrillationvs conventional cardiopulmonary resuscitationin out-of hospital cardiac arrest:the LINC randomized trial
  • 2014
  • Ingår i: Journal of the American Medical Association (JAMA). - : American Medical Association. - 0098-7484 .- 1538-3598. ; 311:1, s. 53-61
  • Tidskriftsartikel (refereegranskat)abstract
    • IMPORTANCE: A strategy using mechanical chest compressions might improve the poor outcome in out-of-hospital cardiac arrest, but such a strategy has not been tested in large clinical trials. OBJECTIVE: To determine whether administering mechanical chest compressions with defibrillation during ongoing compressions (mechanical CPR), compared with manual cardiopulmonary resuscitation (manual CPR), according to guidelines, would improve 4-hour survival. DESIGN, SETTING, AND PARTICIPANTS: Multicenter randomized clinical trial of 2589 patients with out-of-hospital cardiac arrest conducted between January 2008 and February 2013 in 4 Swedish, 1 British, and 1 Dutch ambulance services and their referring hospitals. Duration of follow-up was 6 months. INTERVENTIONS: Patients were randomized to receive either mechanical chest compressions (LUCAS Chest Compression System, Physio-Control/Jolife AB) combined with defibrillation during ongoing compressions (n = 1300) or to manual CPR according to guidelines (n = 1289). MAIN OUTCOMES AND MEASURES: Four-hour survival, with secondary end points of survival up to 6 months with good neurological outcome using the Cerebral Performance Category (CPC) score. A CPC score of 1 or 2 was classified as a good outcome. RESULTS: Four-hour survival was achieved in 307 patients (23.6%) with mechanical CPR and 305 (23.7%) with manual CPR (risk difference, -0.05%; 95% CI, -3.3% to 3.2%; P > .99). Survival with a CPC score of 1 or 2 occurred in 98 (7.5%) vs 82 (6.4%) (risk difference, 1.18%; 95% CI, -0.78% to 3.1%) at intensive care unit discharge, in 108 (8.3%) vs 100 (7.8%) (risk difference, 0.55%; 95% CI, -1.5% to 2.6%) at hospital discharge, in 105 (8.1%) vs 94 (7.3%) (risk difference, 0.78%; 95% CI, -1.3% to 2.8%) at 1 month, and in 110 (8.5%) vs 98 (7.6%) (risk difference, 0.86%; 95% CI, -1.2% to 3.0%) at 6 months with mechanical CPR and manual CPR, respectively. Among patients surviving at 6 months, 99% in the mechanical CPR group and 94% in the manual CPR group had CPC scores of 1 or 2. CONCLUSIONS AND RELEVANCE: Among adults with out-of-hospital cardiac arrest, there was no significant difference in 4-hour survival between patients treated with the mechanical CPR algorithm or those treated with guideline-adherent manual CPR. The vast majority of survivors in both groups had good neurological outcomes by 6 months. In clinical practice, mechanical CPR using the presented algorithm did not result in improved effectiveness compared with manual CPR. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00609778.
  •  
3.
  • Rubertsson, Sten, et al. (författare)
  • Per-Protocol and Pre-Defined population analysis of the LINC study
  • 2015
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 96, s. 92-99
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To perform two predefined sub-group analyses within the LINC study and evaluate if the results were supportive of the previous reported intention to treat (ITT) analysis.METHODS: Predefined subgroup analyses from the previously published LINC study were performed. The Per-Protocol population (PPP) included the randomized patients included in the ITT-population but excluding those with violated inclusion or exclusion criteria and those that did not get the actual treatment to which the patient was randomized. In the Pre-Defined population (PDP) analyses patients were also excluded if the dispatch time to ambulance arrival at the address exceeded 12min, there was a non-witnessed cardiac arrest, or if it was not possible to determine whether the arrest was witnessed or not, and those cases where LUCAS was not brought to the scene at the first instance.RESULTS: After exclusion from the 2589 patients within the ITT-population, the Per-Protocol analysis was performed in 2370 patients and the Pre-Defined analysis within 1133 patients. There was no significant difference in 4-h survival of patients between the mechanical-CPR group and the manual-CPR group in the Per-Protocol population; 279 of 1172 patients (23.8%) versus 281 of 1198 patients (23.5%) (risk difference -0.35%, 95% C.I. -3.1 to 3.8, p=0.85) or in the Pre-Defined population; 176 of 567 patients (31.0%) versus 192 of 566 patients (33.9%) (risk difference -2.88%, 95% C.I. -8.3 to 2.6, p=0.31). There was no difference in any of the second outcome variables analyzed in the Pre-Protocol or Pre-Defined populations.CONCLUSIONS: The results from these predefined sub-group analyses of the LINC study population did not show any difference in 4h survival or in secondary outcome variables between patients treated with mechanical-CPR or manual-CPR. This is consistent with the previously published ITT analysis.
  •  
4.
  • Adler, SS, et al. (författare)
  • PHENIX on-line systems
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 560-592
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each detector subsystem for the purpose of generating events for physics analysis. Processing of event data begins when the Data Collection Modules (DCM) receive data via fiber-optic links from the FEMs. The DCMs format and zero suppress the data and generate data packets. These packets go to the Event Builders (EvB) that assemble the events in final form. The Level-1 trigger (LVL1) generates a decision for each beam crossing and eliminates uninteresting events. The FEMs carry out all detector processing of the data so that it is delivered to the DCMs using a standard format. The FEMs also provide buffering for LVL1 trigger processing and DCM data collection. This is carried out using an architecture that is pipelined and deadtimeless. All of this is controlled by the Master Timing System (MTS) that distributes the RHIC clocks. A Level-2 trigger (LVL2) gives additional discrimination. A description of the components and operation of the PHENIX On-Line system is given and the solution to a number of electronic infrastructure problems are discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
5.
  • Halliwell, Ben, et al. (författare)
  • Habitat saturation promotes delayed dispersal in a social reptile
  • 2017
  • Ingår i: Behavioral Ecology. - : Oxford University Press (OUP). - 1045-2249 .- 1465-7279. ; 28:2, s. 515-522
  • Tidskriftsartikel (refereegranskat)abstract
    • When and where offspring disperse has important implications for the evolutionary emergence and maintenance of group living. In noncooperative breeders, direct benefits of delayed dispersal are relatively limited, suggesting that decisions regarding whether or not to remain in the parental territory are largely driven by the availability of suitable habitat in which to settle. Although there is ample evidence of correlations between habitat saturation and delayed dispersal, experimental tests are rare, particularly for species with facultative group formation. We manipulated the density of conspecifics in enclosed populations of a family living reptile to experimentally evaluate the influence of habitat saturation on the tendency to delay dispersal. Habitat saturation did not influence whether or not offspring explored their surroundings. However, when conspecific density was high, more offspring delayed dispersal and those that did settle in high-density enclosures had reduced survival. These patterns appear to be due to increased dispersal costs imposed by conspecific aggression; offspring that explored high-density enclosures had reduced body condition and a greater risk of mortality. We discuss these results in the context of the evolutionary origins of family living.
  •  
6.
  • Kabakova, Irina V., et al. (författare)
  • Switching and dynamic wavelength conversion in a fiber grating cavity
  • 2012
  • Ingår i: Journal of the Optical Society of America. B, Optical physics. - 0740-3224 .- 1520-8540. ; 29:1, s. 155-160
  • Tidskriftsartikel (refereegranskat)abstract
    • Switching and dynamic wavelength conversion of light are demonstrated in a fiber grating cavity detuned by high-voltage electrical pulses. The cavity dynamics is studied using a heterodyne technique in which the frequency-shifted light, trapped by the cavity, mixes with the backreflected light at the incident frequency. We find that the frequency shift scales linearly with the energy of the electric driving pulses.
  •  
7.
  • Lundgren, Johan, et al. (författare)
  • Acidosis-induced ischemic brain damage: are free radicals involved?
  • 1991
  • Ingår i: Journal of Cerebral Blood Flow and Metabolism. - 1559-7016. ; 11:4, s. 587-596
  • Tidskriftsartikel (refereegranskat)abstract
    • Substantial evidence exists that reactive oxygen species participate in the pathogenesis of brain damage following both sustained and transient cerebral ischemia, adversely affecting the vascular endothelium and contributing to the formation of edema. One likely triggering event for free radical damage is delocalization of protein-bound iron. The binding capacity for some iron-binding proteins is highly pH sensitive and, consequently, the release of iron is enhanced by acidosis. In this study, we explored whether enhanced acidosis during ischemia triggers the production of reactive oxygen species. To that end, enhanced acidosis was produced by inducing ischemia in hyperglycemic rats, with normoglycemic ones serving as controls. Production of H2O2, estimated from the decrease in catalase activity after 3-amino-1,2,4-triazole (AT) administration, was measured in the cerebral cortex, caudoputamen, hippocampus, and substantia nigra (SN) after 15 min of ischemia followed by 5, 15, and 45 min of recovery, respectively (in substantia nigra after 45 min of recovery only). Free iron in cerebrospinal fluid (CSF) was measured after ischemia and 45 min of recovery. Levels of total glutathione (GSH + GSSH) in cortex and hippocampus, and levels of alpha-tocopherol in cortex, were also measured after 15 min of ischemia followed by 5, 15, and 45 min of recovery. The results confirm previous findings that brief ischemia in normoglycemic animals does not measurably increase H2O2 production in AT-injected animals. Ischemia under hyperglycemic conditions likewise failed to induce increased H2O2 production. No difference in free iron in CSF was observed between animals subjected to ischemia under hyper- and normoglycemic conditions. The moderate decrease in total glutathione or alpha-tocopherol levels did not differ between normo- and hyperglycemic animals in any brain region or at any recovery time. Thus, the results failed to give positive evidence for free radical damage following brief periods of ischemia complicated by excessive acidosis. However, it is possible that free radical production is localized to a small subcellular compartment within the tissue, thereby escaping detection. Also, the results do not exclude the possibility that free radicals are pathogenetically important after ischemia of longer duration.
  •  
8.
  • Rubertsson, Sten, et al. (författare)
  • The Study Protocol for the LINC (LUCAS in Cardiac Arrest) Study : a study comparing conventional adult out-of-hospital cardiopulmonary resuscitation with a concept with mechanical chest compressions and simultaneous defibrillation
  • 2013
  • Ingår i: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine. - : BioMed Central Ltd.. - 1757-7241. ; 21:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The LUCAS™ device delivers mechanical chest compressions that have been shown in experimental studies to improve perfusion pressures to the brain and heart as well as augmenting cerebral blood flow and end tidal CO2, compared with results from standard manual cardiopulmonary resuscitation (CPR). Two randomised pilot studies in out-of-hospital cardiac arrest patients have not shown improved outcome when compared with manual CPR. There remains evidence from small case series that the device can be potentially beneficial compared with manual chest compressions in specific situations. This multicentre study is designed to evaluate the efficacy and safety of mechanical chest compressions with the LUCAS™ device whilst allowing defibrillation during on-going CPR, and comparing the results with those of conventional resuscitation. Methods/design This article describes the design and protocol of the LINC-study which is a randomised controlled multicentre study of 2500 out-of-hospital cardiac arrest patients. The study has been registered at ClinicalTrials.gov (http://clinicaltrials.gov/ct2/show/NCT00609778?term=LINC&rank=1 webcite). Results Primary endpoint is four-hour survival after successful restoration of spontaneous circulation. The safety aspect is being evaluated by post mortem examinations in 300 patients that may reflect injuries from CPR. Conclusion This large multicentre study will contribute to the evaluation of mechanical chest compression in CPR and specifically to the efficacy and safety of the LUCAS™ device when used in association with defibrillation during on-going CPR.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy