SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hammo Sari) "

Sökning: WFRF:(Hammo Sari)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hammo, Sari, et al. (författare)
  • Outcome After Endovascular Repair of Ruptured Descending Thoracic Aortic Aneurysm : A National Multicentre Study
  • 2019
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Saunders Elsevier. - 1078-5884 .- 1532-2165. ; 57:6, s. 788-794
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The purpose of this multicentre study was to analyse the outcome of thoracic endovascular aortic repair (TEVAR) in patients with ruptured descending thoracic aortic aneurysm (rDTAA).Methods: This is a nationwide retrospective study including all patients who underwent TEVAR for rDTAA at six major vascular university centres in Sweden between January 2000 and December 2015. Outcome measures were analysed using Kaplan-Meier estimator and multivariable Cox regression.Results: There were 140 patients (age [mean +/- SD] 74.1 +/- 8.8 years; 56% men; aneurysm size 64.8 +/- 19 mm), with rDTAA. In 53 patients (37.9%), the left subclavian artery was covered, and in 25 patients (17.9%) arch vessel revascularisation was performed. In total, 61/136 patients (45%) had a major complication within 30 days post TEVAR. Stroke (n = 20; 14.7%) was the most common complication, followed by paraplegia (n = 13; 9.6%) and major bleeding (n = 13; 9.6%). TEVAR related complications during follow up included endoleaks 22.1% (30/136; 14 type 1a, six type 1b, 10 not defined). In total, re-interventions (n = 31) were required in 27/137 (19.7%) patients. The median follow up time was 17.0 months (range 0-132 months). The Kaplan-Meier estimated survival was 80.0% at one month, 71.7% at three months, 65.3% at one year, 45.9% at three years, and 31.9% at five years. Age (HR 1.03; 95% CI 1.00-1.07; p = .046), history of stroke (HR 2.35; 95% CI 1.194.63; p = .014), previous aortic surgery (HR 2.11; 95% CI 1.15-3.87; p = .016) as well as post-operative major bleeding (HR 4.40; 95% CI 2.20-8.81; p = .001), stroke (HR 2.63; 95% CI 1.37-5.03; p = .004), and renal failure (HR 8.25; 95% CI 2.69-25.35; p = .001) were all associated with mortality.Conclusions: This nationwide multicentre study of patients with rDTAA undergoing TEVAR showed acceptable short- but poor long-term survival. Adequate proximal and distal aortic sealing zones are important for technical success. High risk patients and post-operative complications need to be further addressed in an effort to improve outcome.
  •  
2.
  • Hörer, Tal M, et al. (författare)
  • Unipuncture double-access method in emergent endovascular procedures.
  • 2013
  • Ingår i: Innovations (Philadelphia). - 1556-9845 .- 1559-0879. ; 8:3, s. 245-247
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a technique to gain an additional endovascular access in acute situations in which a large-bore introducer is already inserted or in situations in which multiple accesses are impaired because of other reasons. Using an existing percutaneous femoral artery access, a second guide wire is inserted into the introducer, which is later withdrawn and applied onto one of the two guide wires. A double-wire access is then achieved. This access can be used, for example, for angiography or embolization catheters. This method might be useful in situations in which a quick and unplanned extra access is needed. It is, for example, applicable in hemodynamically unstable patients in whom percutaneous access can be difficult to obtain or in aortic endovascular procedures when an unplanned access is needed to insert an additional catheter for angiography and embolization.
  •  
3.
  • Patel, Jayna J., et al. (författare)
  • Early outcomes associated with use of the Zenith TX2 Dissection Endovascular Graft for the treatment of Stanford type B aortic dissection
  • 2021
  • Ingår i: Journal of Vascular Surgery. - : Elsevier. - 0741-5214 .- 1097-6809. ; 74:2, s. 547-555
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To evaluate short term outcomes related to the use of the Zenith TX2 Dissection Endovascular Graft (ZDEG) and the Zenith Dissection Bare stent (ZDES) for the treatment of Stanford type B aortic dissections. Methods: This retrospective multicenter case cohort study collated data from 10 European institutions for patients with both complicated and uncomplicated type B aortic dissection treated with ZDEG and ZDES between 2011 and 2018. The primary end point was mortality at 30 and 90 days. Secondary end points included complications related to TEVAR, such as, type Ia endoleak, stroke, paraparesis, paraplegia, and retrograde type A dissection (RTAD). Statistical analysis was carried out using the t test, or one-way analysis of variance and the chi(2) or Fisher exact tests. Results: We treated 120 patients (87 male; mean age, 62.7 +/- 12.2years) either in the acute 76 (63.3%), subacute 16 (13.3%), or chronic 28 (23.3%) phase. Seven patients (5.8%) died within 30 days after the index procedure and two (1.7%) between 30 and 90 days. There was one instance of postoperative RTAD in a patient treated for rupture. Stroke and paraplegia occurred in three (2.5%) and five (4.2%), patients, respectively. Eight patients (6.7%) had a type Ia endoleak in the perioperative period. There were no instances of paraplegia, no permanent dialysis, and no requirement for adjunctive superior mesenteric or celiac artery stenting in the 33 patients (27.5%) who were treated by concurrent placement of ZDES distal to the ZDEG. The length and distal oversizing of ZDEG components used was less in this group. Conclusions: The present series demonstrates a low (<1%) RTAD rate and favorable morbidity and mortality. The lower rate of paraplegia, dialysis, and visceral artery stenting in the cohort that had adjunctive use of ZDES is compelling and merits further assessment.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy