SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hevesi M) "

Sökning: WFRF:(Hevesi M)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Divani, AA, et al. (författare)
  • Focal middle cerebral artery ischemia in rats via a transfemoral approach using a custom designed microwire
  • 2016
  • Ingår i: Journal of neurointerventional surgery. - : BMJ. - 1759-8486 .- 1759-8478. ; 8:6, s. 608-614
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to develop a reliable and repeatable method of inducing focal middle cerebral artery occlusion (MCAo) in rats without ligation of the external carotid artery (ECA), while reducing the risk of subarachnoid hemorrhage.MethodsWe prototyped microwires with different diameters (0.0120 inch, 0.0115 inch, 0.0110 inch), materials, and construction methods (coil-on-core, extruded polymer jacket-on-core). Under fluoroscopic guidance and using femoral artery access, the microwires were navigated into the internal carotid artery of male Wistar rats (n=50, weight 376±64 g) to induce MCAo for 1 or 2 h. We performed neurological assessments at baseline, and at 3, 24, 72, and 168 h after MCAo. MRI measurements were performed on a 9.4 T scanner at 1 and 7 days post-injury.ResultsThe 0.0115 inch microwire with polymer jacket-on-core provided the most successful outcome. At 1 and 7 days post-injury, we observed similar infarction volumes for 1 and 2 h MCAo in the MRI study. Infarcted lesion volumes in both MCAo groups were significantly reduced at 7 days compared with 1 day post-injury. The trend in longitudinal changes for the scores of different neurological assessments was confirmed to be significant after the injury, but both groups showed a similar trend of neurological deficits over the course of the study.ConclusionsWe have developed a reliable and repeatable MCAo method in rats, allowing for precise occlusion of the MCA under direct fluoroscopic visualization without alteration of the cerebral hemodynamics associated with ECA ligation. The custom designed microwire can also be sized for targeted focal ischemia in larger animals.
  •  
6.
  • Gyongyosi, M, et al. (författare)
  • Platelet activation and high tissue factor level predict acute stent thrombosis in pig coronary arteries: prothrombogenic response of drug-eluting or bare stent implantation within the first 24 hours
  • 2006
  • Ingår i: Thrombosis and haemostasis. - : Georg Thieme Verlag KG. - 0340-6245 .- 2567-689X. ; 96:2, s. 202-209
  • Tidskriftsartikel (refereegranskat)abstract
    • Increased thrombogenicity of drug-eluting stents (DESs) has recently been reported.The aim of the present study was to investigate the prothrombogenic effect of DESs and Bare stents, and determine factors predictive of acute stent thrombosis (AST) in preclinical experiments using new stent design or coating.Circulating preand post-stenting parameters of platelet activation (mean platelet volume, MPV; platelet distribution width, platelet large cell ratio), thrombin activation (thrombin-antithrombin complex, TAT and prothrombin fragments, F1+2), tissue factor antigen (TF-ag) and -activity (TF-act) and plasminogen activator inhibitor-1 (PAI-1) were measured in 141 consecutive pigs. Stent implantations were performed after pretreatment with aspirin and clopidogrel with unfractionated heparin anticoagulation. Nineteen pigs (groups AST-DES, n=12; and AST-Bare, n=7) died mean 6.3 ± 2.9 h after stent implantation from AST.The remaining 122 control (C) pigs (groups C-DES,n=76,and C-Bare,n=46) survived the 1-month follow-up. Non-significantly elevated levels of post-stent F1+2 and TAT were measured in AST groups. Post-stenting MPV was increased significantly in the groups ASTDES and AST-Bare as compared with the groups C-DES and C-Bare (11.73 ± 1.12 and 11.6 ± 0.68 vs. 8.85 ± 0.78 and 9.04 ± 0.81 fL; p<0.001), similarly toTF-ag (189.1± 87.5 and 127 ± 34.9 vs. 42.5 ± 24.6 and 35.3 ± 37.6 pg/ml; p<0.001, respectively),TF-act (3.23 ± 0.95 and 2.73 ± 1.68 vs. 1.43 ± 1.12 and 1.61 ± 1.31 pM; p<0.01, respectively) and PAI-1 (99.1 ± 15.8 and 99 ± 14.7 vs.53.4 ± 40.2 and 46.9 ± 42.4 ng/ml;p<0.01,respectively).Multivariate analysis revealed elevated post-stenting plasma levels of TF-ag (p=0.016) and MPV (p=0.001) as independent risk factors for developing AST within the first 24 h in a porcine coronary stent model.
  •  
7.
  •  
8.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy