SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hogue Brenda G.) "

Sökning: WFRF:(Hogue Brenda G.)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Li, Haoyuan, et al. (författare)
  • Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source
  • 2020
  • Ingår i: Scientific Data. - : NATURE RESEARCH. - 2052-4463. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 mu m x 1.7 mu m full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.
  •  
2.
  • Munke, Anna, et al. (författare)
  • Data Descriptor : Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source
  • 2016
  • Ingår i: Scientific Data. - : Nature Publishing Group. - 2052-4463. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a wellcharacterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 mu m diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 angstrom ngstrom were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.
  •  
3.
  • Assalauova, Dameli, et al. (författare)
  • An advanced workflow for single-particle imaging with the limited data at an X-ray free-electron laser
  • 2020
  • Ingår i: IUCrJ. - 2052-2525. ; 7, s. 1102-1113
  • Tidskriftsartikel (refereegranskat)abstract
    • An improved analysis for single-particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from half of the detector and a small fraction of single hits. The general SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus-structure determination step. The presented processing pipeline allowed us to determine the 3D structure of bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.
  •  
4.
  • Lee, Ho-Hsien, et al. (författare)
  • Expression, purification and crystallization of CTB-MPR, a candidate mucosal vaccine component against HIV-1
  • 2014
  • Ingår i: IUCrJ. - 2052-2525. ; 1:5, s. 305-317
  • Tidskriftsartikel (refereegranskat)abstract
    • CTB-MPR is a fusion protein between the B subunit of cholera toxin (CTB) andthe membrane-proximal region of gp41 (MPR), the transmembrane envelopeprotein ofHuman immunodeficiency virus 1(HIV-1), and has previously beenshown to induce the production of anti-HIV-1 antibodies with antiviralfunctions. To further improve the design of this candidate vaccine, X-raycrystallography experiments were performed to obtain structural informationabout this fusion protein. Several variants of CTB-MPR were designed,constructed and recombinantly expressed inEscherichia coli. The first variantcontained a flexible GPGP linker between CTB and MPR, and yielded crystalsthat diffracted to a resolution of 2.3 A ̊, but only the CTB region was detectedin the electron-density map. A second variant, in which the CTB was directlyattached to MPR, was shown to destabilize pentamer formation. A thirdconstruct containing a polyalanine linker between CTB and MPR proved tostabilize the pentameric form of the protein during purification. The purificationprocedure was shown to produce a homogeneously pure and monodispersesample for crystallization. Initial crystallization experiments led to pseudo-crystals which were ordered in only two dimensions and were disordered inthe third dimension. Nanocrystals obtained using the same precipitant showedpromising X-ray diffraction to 5 A ̊resolution in femtosecond nanocrystallo-graphy experiments at the Linac Coherent Light Source at the SLAC NationalAccelerator Laboratory. The results demonstrate the utility of femtosecondX-ray crystallography to enable structural analysis based on nano/microcrystalsof a protein for which no macroscopic crystals ordered in three dimensions havebeen observed before.
  •  
5.
  • Reddy, Hemanth K. N., et al. (författare)
  • Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source
  • 2017
  • Ingår i: Scientia Danica. Series H. Humanistica 4. - : Nature Publishing Group. - 1904-5506 .- 2052-4463. ; 4
  • Tidskriftsartikel (refereegranskat)abstract
    • Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65-70 nm, which is considerably smaller than the previously reported similar to 600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. The data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.
  •  
6.
  • Rose, Max, et al. (författare)
  • Single-particle imaging without symmetry constraints at an X-ray free-electron laser
  • 2018
  • Ingår i: IUCrJ. - : INT UNION CRYSTALLOGRAPHY. - 2052-2525. ; 5, s. 727-736
  • Tidskriftsartikel (refereegranskat)abstract
    • The analysis of a single-particle imaging (SPI) experiment performed at the AMO beamline at LCLS as part of the SPI initiative is presented here. A workflow for the three-dimensional virus reconstruction of the PR772 bacteriophage from measured single-particle data is developed. It consists of several well defined steps including single-hit diffraction data classification, refined filtering of the classified data, reconstruction of three-dimensional scattered intensity from the experimental diffraction patterns by orientation determination and a final three-dimensional reconstruction of the virus electron density without symmetry constraints. The analysis developed here revealed and quantified nanoscale features of the PR772 virus measured in this experiment, with the obtained resolution better than 10 nm, with a clear indication that the structure was compressed in one direction and, as such, deviates from ideal icosahedral symmetry.
  •  
7.
  • Sobolev, Egor, et al. (författare)
  • Megahertz single-particle imaging at the European XFEL
  • 2020
  • Ingår i: Communications Physics. - : Springer Science and Business Media LLC. - 2399-3650. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL is expected to provide 27,000 pulses per second, over two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The results obtained pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy