  • Hellevuo, Heidi, et al. (författare)
  • Deeper chest compression - More complications for cardiac arrest patients?
  • 2013
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 84:6, s. 760-765
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim of the study: Sternal and rib fractures are frequent complications caused by chest compressions during cardiopulmonary resuscitation (CPR). This study aimed to investigate the potential association of CPR-related thoracic and abdominal injuries and compression depth measured with an accelerometer. Methods: We analysed the autopsy records, CT scans or chest radiographs of 170 adult patients, suffering in-hospital cardiac arrest at the Tampere University Hospital during the period 2009-2011 to investigate possible association of chest compressions and iatrogenic injuries. The quality of manual compressions during CPR was recorded on a Philips, HeartStart MRx Q-CPR (TM)-defibrillator. Results: Patients were 110 males and 60 females. Injuries were found in 36% of male and 23% of female patients. Among male patients CPR-related injuries were associated with deeper mean - and peak compression depths (p < 0.05). No such association was observed in women. The frequency of injuries in mean compression depth categories <5, 5-6 and >6 cm, was 28%, 27% and 49% (p = 0.06). Of all patients 27% sustained rib fractures, 11% sternal fracture and eight patients had haematomas/ruptures in the myocardium. In addition, we observed one laceration of the stomach without bleeding, one ruptured spleen, one mediastinal haemorrhage and two pneumothoraxes. Conclusion: The number of iatrogenic injuries in male patients was associated with chest compressions during cardiopulmonary resuscitation increased as the measured compression depth exceeded 6 cm. While there is an increased risk of complications with deeper compressions it is important to realize that the injuries were by and large not fatal. 
  •  
6.
  • Hellevuo, H., et al. (författare)
  • Good quality of life before cardiac arrest predicts good quality of life after resuscitation
  • 2018
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : WILEY. - 0001-5172 .- 1399-6576. ; 62:4, s. 515-521
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The survival rate of cardiac arrest patients is increasing. Our aim was to compare the quality of life before and after cardiac arrest and analyse the factors associated with outcome.Methods. All adult cardiac arrest patients admitted to the Tampere University Hospital intensive care unit between 2009 and 2011 were included in a retrospective follow-up study if surviving to discharge and were asked to return a questionnaire after 6 months. Data on patient demographics and pre-arrest quality of life were retrieved from medical records. Data are given as means (SD) or medians [Q(1), Q(3)]. We used logistic regression to identify factors associated with better quality of life after cardiac arrest.Results. Six months after cardiac arrest, 36% (79/222) were alive and 70% (55/79) of those patients completed the follow-up EuroQoL (EQ-5D) quality of life questionnaire. Median values for the EQ-5D before and after cardiac arrest were 0.89 [0.63, 1] and 0.89 [0.62, 1], respectively (P = 0.75). Only the EQ-5D prior to cardiac arrest was associated with better quality of life afterwards (OR 1.2; 95% CI 1.0-1.3; P = 0.02).Conclusions. Quality of life remained good after cardiac arrest especially in those patients who had good quality of life before cardiac arrest.
  •  
7.
  • Hellevuo, H, et al. (författare)
  • The quality of manual chest compressions during transport : effect of the mattress assessed by dual accelerometers
  • 2014
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 58:3, s. 323-328
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUNDThe quality of cardiopulmonary resuscitation (CPR) has an impact on survival. The quality may be impaired if the patient needs to be transported to the hospital with ongoing CPR. The aim of this study was to analyse whether the quality of CPR can be improved during transportation by using real-time audiovisual feedback. In addition, we sought to evaluate the real compression depths taking into account the mattress and stretcher effect.METHODSParamedics (n = 24) performed standard CPR on a Resusci Anne Mannequin in a moving ambulance. Participants were instructed to perform CPR according to European Resuscitation Council Resuscitation guidelines 2010. Each pair acted as their own controls performing CPR first without and then with the feedback device. Compression depth, rate and no-flow fraction and also the mattress effect were recorded by using dual accelerometers by two Philips, HeartStart MRx Q-CPR defibrillators.RESULTSIn the feedback phase, the mean compression depth increased from 51 (10) to 56 (5) mm (P < 0.001), and the percentage of compression fractions with adequate depth was 60% vs. 89% (P < 0.001). However, taking account of the mattress effect, the real depth was only 41 (8) vs. 44 (5) mm without and with feedback, respectively (P < 0.001). The values for compression rate did not differ.CONCLUSIONSCPR quality was good during transportation in general. However, the results suggest that the feedback system improves CPR quality. Dual accelerometer measurements show, on the other hand, that the mattress effect may be a clinically relevant impediment to high quality CPR.
  •  
8.
  •  
9.
  •  
10.
  •  
11.
  •  
12.
  • Kämäräinen, Antti, et al. (författare)
  • Quality controlled manual chest compressions and cerebral oxygenation during in-hospital cardiac arrest
  • 2012
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 83:1, s. 138-142
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM:The quality of cardiopulmonary resuscitation (CPR) is associated with the rate of return of spontaneous circulation (ROSC) during human cardiac arrest. Current advances in defibrillator technology enable measurement of CPR quality during resuscitation, but it is not known whether this is directly reflected in cerebral oxygenation. In this descriptive study we aimed to evaluate whether the quality of feedback-monitored CPR during in-hospital cardiac arrest is reflected in near infrared frontal cerebral spectroscopy (NIRS).METHODS:Nine patients suffering an in-hospital cardiac arrest in a university hospital were included. All patients underwent quality-controlled CPR performed by a dedicated medical emergency team using a Philips HeartStart MRx defibrillator (Philips, Eindhoven, Netherlands) with a CPR quality (Q-CPR, Laerdal Medical, Stavanger, Norway) analysis feature. Simultaneously, bilateral frontal cerebral oximetry was measured using INVOS 5100c (Somanetics, Troy, MI, USA) NIRS.RESULTS:During quality controlled resuscitation, regional cerebral oxygenation (rSO2) as measured with NIRS was low but it improved during CPR (p = 0.043) and 8 min after ROSC (p = 0.022). After the onset of NIRS recording, there were four episodes exceeding 30 s, during which the quality of CPR was substandard. When CPR technique was corrected and maintained for 2 min, a minor non-significant increase in rSO2 was observed in two cases.CONCLUSIONS:High quality CPR was not significantly reflected in cerebral oxygenation as quantified using NIRS. Even after ROSC and subsequent significant increase in cerebral oxygenation, rSO2 readings were below previously suggested threshold of cerebral ischaemia. Improving CPR technique after an episode of low quality CPR did not significantly increase rSO2.
  •  
13.
  • NiemeläInen, Mika J., et al. (författare)
  • Different incidences of knee arthroplasty in the Nordic countries : A population-based study from the Nordic Arthroplasty Register Association
  • 2017
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 88:2, s. 173-178
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose — The annual number of total knee arthroplasties (TKAs) has increased worldwide in recent years. To make projections regarding future needs for primaries and revisions, additional knowledge is important. We analyzed and compared the incidences among 4 Nordic countries Patients and methods — Using Nordic Arthroplasty Register Association (NARA) data from 4 countries, we analyzed differences between age and sex groups. We included patients over 30 years of age who were operated with TKA or unicompartmental knee arthroplasty (UKA) during the period 1997–2012. The negative binomial regression model was used to analyze changes in general trends and in sex and age groups. Results — The average annual increase in the incidence of TKA was statistically significant in all countries. The incidence of TKA was higher in women than in men in all 4 countries. It was highest in Finland in patients aged 65 years or more. At the end of the study period in 2012, Finland’s total incidence was double that of Norway, 1.3 times that of Sweden and 1.4 times that of Denmark. The incidence was lowest in the youngest age groups (< 65 years) in all 4 countries. The proportional increase in incidence was highest in patients who were younger than 65 years. Interpretation — The incidence of knee arthroplasty steadily increased in the 4 countries over the study period. The differences between the countries were considerable, with the highest incidence in Finland. Patients aged 65 years or more contributed to most of the total incidence of knee arthroplasty.
  •  
14.
  • Sainio, Marko, et al. (författare)
  • Association of arterial blood pressure and CPR quality in a child using three different compression techniques, a case report
  • 2013
  • Ingår i: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine. - : Springer Science and Business Media LLC. - 1757-7241. ; 21, s. 51-
  • Tidskriftsartikel (refereegranskat)abstract
    • A 2-year-old boy found in cardiac arrest secondary to drowning received standard CPR for 35 minutes and was transported to a tertiary hospital for rewarming from hypothermia. Chest compressions in hospital were started using two-thumb encircling hands technique. Subsequently two-thumbs direct sternal compression technique and after sternal force/depth sensor placement, chest compression with classic one-hand technique were done. By using CPR recording/feedback defibrillator, quantitative CPR quality data and invasive arterial pressures were available for analyses for 5 hours and 35 minutes. 316 compressions with the two-thumb encircling hands technique provided a mean (SD) systolic arterial pressure (SAP) of 24 (4) mmHg, mean arterial pressure (MAP) 18 (3) and diastolic arterial pressure (DAP) of 15 (3) mmHg. similar to 6000 compressions with the two thumbs direct compression technique created a mean SAP of 45 (7) mmHg, MAP 35 (4) mmHg and DAP of 30 (3) mmHg. similar to 20,000 compressions with the sternal accelerometer in place produced SAP 50 (10) mmHg, MAP 32 (5) mmHg and DAP 24 (4) mmHg. Restoration of spontaneous circulation (ROSC) was achieved at the point when the child achieved normothermia by using peritoneal dialysis. Unfortunately, the child died ten hours after ROSC without any signs of neurological recovery. This case demonstrates improved hemodynamic parameters with classic one-handed technique with real-time quantitative quality of CPR feedback compared to either the two-thumbs encircling hands or two-thumbs direct sternal compression techniques. We speculate that the improved arterial pressures were related to improved chest compression depth when a real-time CPR recording/feedback device was deployed.
  •  
15.
  • Sainio, Marko, et al. (författare)
  • Effect of mattress and bed frame deflection on real chest compression depth measured with two CPR sensors
  • 2014
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 85:6, s. 840-843
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: Implementation of chest compression (CC) feedback devices with a single force and deflection sensor (FDS) may improve the quality of CPR. However, CC depth may be overestimated if the patient is on a compliant surface. We have measured the true CC depth during in-hospital CPR using two FDSs on different bed and mattress types. Methods: This prospective observational study was conducted at Tampere University Hospital between August 2011 and September 2012. During in-hospital CPR one FDS was placed between the rescuer's hand and the patient's chest, with the second attached to the backboard between the patient's back and the mattress. The real CC depth was calculated as the difference between the total depth from upper FDS to lower FDS. Results: Ten cardiac arrests on three different bed and mattress types yielded 10,868 CCs for data analyses. The mean (SD) mattress/bed frame effect was 12.8 (4) mm on a standard hospital bed with a gel mattress, 12.4 (4) mm on an emergency room stretcher with a thin gel mattress and 14.1 (3) mm on an ICU bed with an emptied air mattress. The proportion of CCs with an adequate depth (>= 50 mm) decreased on all mattress types after compensating for the mattress/bed frame effect from 94 to 64%, 98 to 76% and 91 to 17%, in standard hospital bed, emergency room stretcher and ICU bed, respectively (p < 0.001). Conclusion: The use of FDS without real-time correction for deflection may result in CC depth not reaching the recommended depth of 50 mm.
  •  
16.
  • Sainio, Marko, et al. (författare)
  • Real-time audiovisual feedback system in a physician-staffed helicopter emergency medical service in Finland : the quality results and barriers to implementation
  • 2013
  • Ingår i: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine. - : Springer Science and Business Media LLC. - 1757-7241. ; 21, s. 50-
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To evaluate the quality of cardiopulmonary resuscitation (CPR) in a physician staffed helicopter emergency medical service (HEMS) using a monitor-defibrillator with a quality analysis feature. As a post hoc analysis, the potential barriers to implementation were surveyed. Methods: The quality of CPR performed by the HEMS from November 2008 to April 2010 was analysed. To evaluate the implementation rate of quality analysis, the HEMS database was screened for all cardiac arrest missions during the study period. As a consequence of the observed low implementation rate, a survey was sent to physicians working in the HEMS to evaluate the possible reasons for not utilizing the automated quality analysis feature. Results: During the study period, the quality analysis was used for 52 out of 187 patients (28%). In these cases the mean compression depth was < 40 mm in 46% and < 50 mm in 96% of the 1-min analysis intervals, but otherwise CPR quality corresponded with the 2005 resuscitation guidelines. In particular, the no-flow fraction was remarkably low 0.10 (0.07, 0.16). The most common reasons for not using quality-controlled CPR were that the device itself was not taken to the scene, or not applied to the patient, because another EMS unit was already treating the patient with another defibrillator. Conclusions: When quality-controlled CPR technology was used, the indicators of good quality CPR as described in the 2005 resuscitation guidelines were mostly achieved albeit with sufficient compression depth. The use of the well-described technology in improving patient care was low. Wider implementation of the automated quality control and feedback feature in defibrillators could further improve the quality of CPR on the field.
  •  
17.
  • Sainio, Marko, et al. (författare)
  • Simultaneous beat-to-beat assessment of arterial blood pressure and quality of cardiopulmonary resuscitation in out-of-hospital and in-hospital settings
  • 2015
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 96, s. 163-169
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The current recommendation for depth and rate of chest compression (CC) during cardiopulmonary resuscitation (CPR) is based on limited hemodynamic data recorded during human CPR. We have evaluated the possible association between CC depth and rate and continuously measured arterial blood pressure during adult CPR. Methods: This prospective study included data from 104 patients resuscitated inside or outside hospital. Adequate data on continuously measured invasive arterial blood pressure (BP) and the quality of CPR from a defibrillator capable recording CPR quality parameters was successful in 39 patients. We used logistic regression and mixed effects modeling to identify CC depths and rates associated with systolic blood pressure (SBP) >= 85 mmHg and diastolic blood pressure (DBP) >= 30 mmHg. Results: We analyzed 41,575 compression-BP pairs. The values for blood pressure varied greatly between the patients. SBP varied from 25 to 225 mmHg and DBP from 2 to 59 mmHg. CC rate 100-120/min and CC depth >= 60 mm (without mattress deflection correction) was associated with DBP >= 30 mmHg in both femoral (OR 1.14; 95% CI 1.03, 1.26; p < 0.05) and radial (OR 4.70; 95% CI 3.92, 5.63; p < 0.001) recordings. For any given subject there was a weak upward trend in blood pressure as CC depth increased. Conclusion: Deeper CC does not equal higher BP in every patient. The heterogeneity of patients creates a challenge to find the optimal way to resuscitate patients individually.
  •  
18.
  •  
19.
  •  
20.
  • Tirkkonen, Joonas, et al. (författare)
  • Factors associated with delayed activation of medical emergency team and excess mortality : An Utstein-style analysis
  • 2013
  • Ingår i: Resuscitation. - : Elsevier BV. - 0300-9572 .- 1873-1570. ; 84:2, s. 173-178
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM:We used the Utstein template, with special reference to patients having automated patient monitoring, and studied the factors which are associated with delayed medical emergency team (MET) activation and increased hospital mortality.DESIGN AND SETTING:A prospective observational study in a tertiary hospital with 45 of 769 general ward beds (5.9%) equipped with automated monitoring.COHORT:569 MET reviews for 458 patients.RESULTS: Basic MET review characteristics were comparable to literature. We found that 41% of the reviews concerned monitored ward patients. These patients' vitals had been more frequently documented during the 6h period preceding MET activation compared to patients in normal ward areas (96% vs. 74%, p<0.001), but even when adjusted to the documentation frequency of vitals, afferent limb failure (ALF) occurred more often among monitored ward patients (81% vs. 53%, p<0.001). In MET population, factors associated with increased hospital mortality were non-elective hospital admission (OR 6.25, 95% CI 2.77-14.11), not-for-resuscitation order (3.34, 1.78-6.35), ICD XIV genitourinary diseases (2.42, 1.16-5.06), ICD II neoplasms (2.80, 1.59-4.91), age (1.02, 1.00-1.04), preceding length of hospital stay (1.04, 1.01-1.07), ALF (1.67, 1.02-2.72) and transfer to intensive care (1.85, 1.05-3.27).CONCLUSIONS:Documentation of vital signs before MET activation is suboptimal. Documentation frequency seems to increase if automated monitors are implemented, but our results suggest that benefits of intense monitoring are lost without appropriate and timely interventions, as afferent limb failure, delay to call MET when predefined criteria are fulfilled, was independently associated to increased hospital mortality.
  •  
21.
  • Tirkkonen, Joonas, et al. (författare)
  • Medical emergency team activation : performance of conventional dichotomised criteria versus national early warning score
  • 2014
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 58:4, s. 411-419
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundTo activate the hospital's medical emergency team (MET), either conventional dichotomised activation criteria or an early warning scoring system may be used. The relative performance of these different activation patterns to discriminate high risk patients in a heterogenic general ward population after adjustment for multiple confounding factors has not been evaluated. We aimed to evaluate the dichotomised activation criteria used at our institution and the recently published national early warning score (NEWS, United Kingdom). Materials and MethodsProspective point prevalence study at a university hospital in Finland. On two separate days, the vital signs of all adult patients without treatment limitations were measured. Data on cumulative comorbidity (Charlson comorbidity index), age, gender, admission characteristics and subsequent mortality were collected. Univariate and multivariate logistic regression models were used for unadjusted and adjusted performance testing. ResultsThe cohort consisted of 615 patients. The dichotomised activation criteria were not associated with in-hospital serious adverse events (odds ratio 1.87, 95% confidence interval 0.55-6.30) or 30-day mortality (2.13, 0.79-5.72) after adjustments. For a NEWS of seven or more (the suggested trigger level for immediate MET activation), the adjusted odds ratios for the above mentioned outcomes were 7.45 (2.39-23.3) and 11.4 (4.40-29.6), respectively. Unlike the dichotomised activation criteria, NEWS was also independently associated with a higher 60- and 180-day mortality after adjustments. ConclusionsNEWS discriminates high risk patients in a heterogenic general ward population independently of multiple confounding factors. The conventional dichotomised activation criteria were not able to detect high risk patients.
  •  
22.
  • Tirkkonen, J., et al. (författare)
  • Vital dysfunctions after intensive care discharge : prevalence and impact on patient outcome
  • 2013
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 57:1, s. 56-62
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Patients discharged from the intensive care unit (ICU) are at increased risk for serious adverse events (SAEs). Recording vital functions and comprehending the consequences of altered vitals on general wards may be suboptimal. This potentially endangers recovery after successful intensive care. We aimed to determine the prevalence of vital dysfunctions after ICU discharge and their effect on patient outcome. Methods A prospective observational study. Adult patients discharged from a tertiary referral hospital ICU to general wards without treatment limitations were visited 24?h afterwards; their vitals were measured and reported to ward staff. Attending ward nurse responsible for patient was interviewed. Results The cohort consisted of 184 patients who had survived the first 24?h on the ward without complications (age: 57 +/- 16 years; male: 68%). The prevalence of objectively measured vital dysfunctions was 15%, and the attending nurse had been unusually concerned about the patient in 19% of cases. Of the 184 patients, 9.8% subsequently suffered an SAE. In a multivariate logistic regression model, only vital dysfunctions (odds ratio 3.79; 95% confidence interval 1.18-12.2) and nurse concern (3.63; 1.17-11.3) were independently associated with an increased incidence of SAE. Medical emergency team (MET) assistance was never considered necessary by ward staff. Sensitivity of observed altered vitals on SAEs was 50% and specificity 89%. Sensitivity of nurse concern was 26%, specificity 84%. Conclusions Simple vital function measurement and attending ward nurse's subjective assessment facilitate early detection of post-ICU patients at risk. The threshold in seeking assistance through MET remains high.
  •  
23.
  • Viskari, H, et al. (författare)
  • Relationship between the incidence of type 1 diabetes and maternal enterovirus antibodies : Time trends and geographical variation
  • 2005
  • Ingår i: Diabetologia. - : Springer Science and Business Media LLC. - 0012-186X .- 1432-0428. ; 48:7, s. 1280-1287
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims/hypothesis: We have previously observed an inverse correlation between the incidence of type 1 diabetes and enterovirus infections in the background population. The aim of this study was to analyse whether maternal enterovirus antibody status, which reflects both the frequency of enterovirus infections and the protection conferred by the mother on the offspring, also correlates with the incidence of type 1 diabetes. Methods: Maternal enterovirus antibodies were analysed from serum samples taken from pregnant women between 1983 and 2001 in Finland and Sweden using enzyme immunoassay and neutralisation assays. Comparable samples were also taken between 1999 and 2001 in countries with a lower incidence of diabetes (Estonia, Germany, Hungary, Israel, Lithuania, Russia). Results: A clear decrease was observed in maternal enterovirus antibody levels over the past 20 years (p<0.0001). The frequency of enterovirus antibodies was higher in countries with a low or intermediate incidence of type 1 diabetes compared with high-incidence countries (p<0.0001). Conclusions/interpretation: These findings are in line with our previous observations supporting the hypothesis that a low frequency of enterovirus infection in the background population increases the susceptibility of young children to the diabetogenic effect of enteroviruses. © Springer-Verlag 2005.
  •  