SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Iliescu M.) "

Sökning: WFRF:(Iliescu M.)

  • Resultat 1-34 av 34
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Curceanu, C., et al. (författare)
  • Kaonic deuterium measurement with Siddharta-2 on daΦNE
  • 2020
  • Ingår i: Acta Physica Polonica B. - 0587-4254. ; 51:1, s. 251-257
  • Tidskriftsartikel (refereegranskat)abstract
    • The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms is, in this context, a unique tool to obtain precise information on this interaction. The most precise kaonic hydrogen measurement to date, together with an exploratory measurement of kaonic deuterium, were carried out by the SIDDHARTA Collaboration at the DAΦNE electron–positron collider of LNF-INFN, by combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and precise Silicon-Drift X-ray detectors. The measurement of kaonic deuterium will be realized in the near future by SIDDHARTA-2, a major upgrade of SIDDHARTA.
  •  
6.
  • Miliucci, M., et al. (författare)
  • Kaonic Deuterium Precision Measurement at DA Φ NE : The SIDDHARTA-2 Experiment
  • 2020
  • Ingår i: Recent Progress in Few-Body Physics : Proceedings of the 22nd International Conference on Few-Body Problems in Physics, FB22 2018 - Proceedings of the 22nd International Conference on Few-Body Problems in Physics, FB22 2018. - Cham : Springer International Publishing. - 0930-8989 .- 1867-4941. - 9783030323561 - 9783030323578 ; 238, s. 965-969
  • Bokkapitel (refereegranskat)abstract
    • Light kaonic atoms spectroscopy offers the unique opportunity to perform experiments equivalent to scattering at vanishing relative energies. This allows the determination of the antikaon-nucleus interaction at threshold, without the need of extrapolation to zero energy, as in the case of scattering experiments. In this framework, the SIDDHARTA-2 collaboration aims to perform the first measurement of kaonic deuterium transition to the fundamental level, which is mandatory to extract the isospin dependent antikaon—nucleon scattering lengths. The experiment will be carried out at the DA(formula presented)NE collider of LNF-INFN in 2019–2020.
  •  
7.
  • Asano, H., et al. (författare)
  • Spectroscopic study of the Λ(1405) resonance via the d (K-, n) reaction at J-PARC
  • 2019
  • Ingår i: 13th International Conference on Hypernuclear and Strange Particle Physics, HYP 2018. - : AIP Publishing. - 9780735418721 ; 2130
  • Konferensbidrag (refereegranskat)abstract
    • The structure of the Λ(1405) hyperon is an important and long-standing issue related to the K̄-nucleus interaction. The J-PARC E31 experiment has been performed to investigate the Λ(1405) spectrum shape. Because it is hard to form the Λ(1405) directly by a K̄N scattering in free space, E31 uses the d(K-, n) reaction with an incident kaon momentum of 1 GeV/c. We will identify three final states - ς-π+, ς+π-, ς0π0-so that the isospin structure of hyperon resonance states produced can be decomposed. The first physics run of the E31 experiment was performed in 2016. To enhance the statistics of the data set, we have performed the second physics run in the beginning of 2018. During the second run of E31, around 3.9×1010 kaons impacted on the deuteron target.
  •  
8.
  • De Paolis, L., et al. (författare)
  • Kaonic atoms measurement at DA Φ NE : SIDDHARTA and SIDDHARTA-2
  • 2019
  • Ingår i: Basic Concepts in Nuclear Physics : Theory, Experiments and Applications - 2018 La Rábida International Scientific Meeting on Nuclear Physics - Theory, Experiments and Applications - 2018 La Rábida International Scientific Meeting on Nuclear Physics. - Cham : Springer International Publishing. - 9783030222031 ; 225, s. 191-195
  • Konferensbidrag (refereegranskat)abstract
    • Light kaonic atoms studies provide the unique opportunity to perform experiments equivalent to scattering at threshold, being their atomic binding energies in the keV range. High precision atomic X-rays spectroscopy ensures that the energy shift and broadening of the lowest-lying states of the kaonic atoms, induced by the strong interaction between the kaon and nucleus, can be detected. Kaonic hydrogen and kaonic deuterium are the lightest atomic systems and their study deliver the isospin-dependent kaon-nucleon scattering lengths. The SIDDHARTA collaboration was able to perform the most precise kaonic hydrogen measurement to date, together with an exploratory measurement of kaonic deuterium. The measurement of the kaonic deuterium will be realized in the near future by a major upgrade of SIDDHARTA: SIDDHARTA-2. In this paper an overview of the main results obtained by SIDDHARTA together with the future plans are presented.
  •  
9.
  • Yamaga, Takumi, et al. (författare)
  • Study of the elementary (K -, n) reactions to search for the K NN bound state via the 3He (K -, n) reaction at J-PARC
  • 2016
  • Ingår i: XVIth International Conference on Hadron Spectroscopy, Hadron 2015. - : Author(s). - 9780735413894 ; 1735
  • Konferensbidrag (refereegranskat)abstract
    • We have searched for the simplest kaonic nuclear state, K̄NN, using the in-flight 3He (K-, n) reaction at the J-PARC hadron experimental facility. In the semi-inclusive neutron missing-mass spectrum at θnlab=0°, an excess of yield was observed just below the K- pp mass-threshold, which cannot be explained by any elementary reactions [PTEP 2015, 061D01]. To understand the missing-mass spectrum of 3He (K-, n) X, we investigated the elementary (K-, n) reactions using hydrogen and deuterium targets. The p (K-, n) X missing-mass spectrum was well described by the charge-exchange reaction. However, in the d (K-, n) X spectrum, we observed an excess of yield just below the K- p mass-threshold, which was similar to that in the 3He (K-, n) X spectrum.
  •  
10.
  • Curceanu, C., et al. (författare)
  • Low-energy kaon-nuclei interaction studies at DAΦNE : Siddharta-2 and amadeus
  • 2017
  • Ingår i: Acta Physica Polonica B. - 0587-4254. ; 48:10, s. 1855-1860
  • Tidskriftsartikel (refereegranskat)abstract
    • The DAΦNE electron-positron collider of the Laboratori Nazionali di Frascati of INFN has made available a unique quality low-energy negatively charged kaons "beam", which is being used to study the kaon-nucleon/nuclei interactions by the SIDDHARTA-2 experiment and the AMADEUS Collaboration. The dynamics of the strong interaction processes in the nonperturbative regime is approached by lattice calculations and effective field theories (ChPT) which are still lacking experimental results in the lowenergy regime, fundamental for their good understanding. The studies of kaonic atoms and of the kaonic nuclear processes performed by SIDDHARTA- 2 and AMADEUS play in this context a key-role.
  •  
11.
  • Curceanu, C., et al. (författare)
  • The kaonic atoms research program at DAΦNE : Overview and perspectives
  • 2018
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 1138:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms is, in this context, a unique tool to obtain precise information on this interaction. The energy shift and broadening of the lowest-lying states of such atoms, induced by the kaon-nucleus strong interaction, can be determined with high precision from atomic X-ray spectroscopy. This experimental method provides unique information to understand the low energy kaon-nucleus interaction at threshold. The lightest atomic systems, kaonic hydrogen and kaonic deuterium, deliver the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to date, together with an exploratory measurement of kaonic deuterium, were carried out by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN, by combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and precise X-ray detectors: Silicon Drift Detectors. The measurement of kaonic deuterium will be realized in the near future by SIDDHARTA-2, a major upgrade of SIDDHARTA. In this paper an overview of the main results obtained by SIDDHARTA together with the future plans, are given.
  •  
12.
  • Marton, J., et al. (författare)
  • Spectroscopy of kaonic atoms at DAFNE and J-PARC
  • 2019
  • Ingår i: Proceedings - 15th International Workshop on Meson Physics, MESON 2018. - : EDP Sciences.
  • Konferensbidrag (refereegranskat)abstract
    • The interaction of antikaons (K) with nucleons and nuclei in the low-energy regime represents a very active research field in hadron physics. A unique and rather direct experimental access to the antikaon-nucleon scattering lengths is provided by precision X-ray spectroscopy of transitions in low-lying states in the lightest kaonic atoms (i.e. kaonic hydrogen and deuterium). In the SIDDHARTA experiment at the electron-positron collider DAFNE of LNFINFN we measured the most precise values of the strong interaction observables in conic hydrogen. The strong interaction on the 1s ground state of the electromagnetically bound K-p atom causes an energy shift and broadening of the 1s state. SIDDHARTA will extend the spectroscopy to kaonic deuterium to get access to the antikaon-neutron interaction and thus the isospin dependent scattering lengths. At J-PARC a kaon beam is used in a complementary experiment with a different setup for spectroscopy of kaonic deuterium atoms. The talk will give an overview of the of the upcoming experiments SIDDHARTA and the complementary experiment at J-PARC.Furthermore, the implications of the experiments for the theory of low-energy strong interaction with strangeness will be discussed.
  •  
13.
  • Sada, Y., et al. (författare)
  • Structure near the K- + p + p threshold in the in-flight 3He(K-, Λp)n reaction
  • 2016
  • Ingår i: Progress of Theoretical and Experimental Physics. - : Oxford University Press (OUP). - 2050-3911. ; 2016:5
  • Tidskriftsartikel (refereegranskat)abstract
    • To search for an S = -1 di-baryonic state which decays toΛp, the 3He(K-,Λp)nmissing reaction was studied at 1.0 GeV/c. Unobserved neutrons were kinematically identified from the missing mass MX of the 3He (K-,Λp) X reaction in order to have a large acceptance for the Λpn final state. The observed Λpn events, distributed widely over the kinematically allowed region of the Dalitz plot, establish that the major component comes from a three-nucleon absorption process. A concentration of events at a specific neutron kinetic energy was observed in a region of low momentum transfer to the Λp. To account for the observed peak structure, the simplest S-wave polewas assumed to exist in the reaction channel, having a Breit-Wigner formin energy and with a Gaussian form factor. A minimum X2 method was applied to deduce its mass, MX = 2355+6 -8 (stat.) ±12 (syst.)MeV/c2, and decay width, γX = 110+19 -17 (stat.) ±27 (syst.)MeV/c2, respectively. The form factor parameter QX ∼ 400MeV/c implies that the range of the interaction is about 0.5 fm.
  •  
14.
  • Scordo, A., et al. (författare)
  • The kaonic atoms research program at DAΦNE : From SIDDHARTA to SIDDHARTA-2
  • 2018
  • Ingår i: EPJ Web of Conferences. - : EDP Sciences. - 2101-6275 .- 2100-014X. ; 181
  • Tidskriftsartikel (refereegranskat)abstract
    • The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms, in which one electron is replaced by a negatively charged kaon, is a unique tool to provide precise information on this interaction; the energy shift and the broadening of the low-lying states of such atoms, induced by the kaon-nucleus hadronic interaction, can be determined with high precision from the atomic X-ray spectroscopy, and this experimental method provides unique information to understand the low energy kaon-nucleus interaction at the production threshold. The lightest atomic systems, like the kaonic hydrogen and the kaonic deuterium deliver, in a model-independent way, the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to-date, together with an exploratory measurement of kaonic deuterium, were carried out in 2009 by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN, combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and very precise X-ray detectors, like the Silicon Drift Detectors. The SIDDHARTA results triggered new theoretical work, which achieved major progress in the understanding of the low-energy strong interaction with strangeness reflected by the antikaon-nucleon scattering lengths calculated with the antikaon-proton amplitudes constrained by the SIDDHARTA data. The most important open question is the experimental determination of the hadronic energy shift and width of kaonic deuterium; presently, a major upgrade of the setup, SIDDHARTA-2, is being realized to reach this goal. In this paper, the results obtained in 2009 and the proposed SIDDHARTA-2 upgrades are presented.
  •  
15.
  • Sirghi, D., et al. (författare)
  • Experiments with low-energy kaons at the DAΦNE Collider
  • 2019. - 1
  • Ingår i: XIII International Conference on Beauty, Charm and Hyperon Hadrons (BEACH 2018) 17–23 June 2018, Peniche, Portugal. - : IOP Publishing. - 1742-6588. ; 1137
  • Konferensbidrag (refereegranskat)abstract
    • The investigations of light kaonic atoms offer the unique opportunity to perform experiments equivalent to scattering at vanishing relative energies, being their atomic binding energies in the keV range. This allows the determination of the hadron-nucleus interaction at threshold without the need of an extrapolation to zero relative energy. The energy shift and broadening of the lowest-lying states of such atoms, induced by the kaon-nucleus strong interaction, can be determined with high precision from atomic X-ray spectroscopy. The lightest atomic systems, kaonic hydrogen and kaonic deuterium, deliver the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to date, together with an exploratory measurement of kaonic deuterium, were carried out by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN. The measurement of kaonic deuterium will be realized in the near future by SIDDHARTA-2, a major upgrade of SIDDHARTA. A correlated study of the kaon-nuclei interaction at momenta below 130 MeV/c is carried out by the AMADEUS collaboration, using the KLOE detector and dedicated targets inserted near the collider interaction point. In this paper an overview of the main results obtained by SIDDHARTA together with the future plans, the SIDDHARTA-2 experiment and with the preliminary results of the study of charged antikaons interacting with nuclei by the AMADEUS collaboration, are shown.
  •  
16.
  • Sirghi, D., et al. (författare)
  • Kaonic atoms measurements at the DAΦNE Collider
  • 2018
  • Ingår i: Proceedings of Science. - 1824-8039. ; 336
  • Konferensbidrag (refereegranskat)abstract
    • The DAΦNE electron-positron collider of the Laboratori Nazionali di Frascati of INFN is a worldwide unique low-energy kaon source, which is being used to produce and to study kaonic atoms by the SIDDHARTA collaboration. The X-ray measurements of kaonic atoms play an important role for understanding the low-energy QCD in the strangeness sector. Significant achievements have been obtained by the SIDDHARTA experiment, among which: the most precise kaonic hydrogen measurement of the 1s level shift and width induced by the presence of the strong interaction; an upper limit of the X-ray yield for kaonic deuterium K-series; the accurate measurement of the 2p level shift and width of kaonic helium-4 and kaonic helium-3; yields of various light kaonic atoms transitions. Using the experience gained with SIDDHARTA experiment, the first kaonic deuterium measurement is in preparation in the framework of the SIDDHARTA-2 experiment, with the goal to determine the antikaon-nucleon isospin dependent scattering lengths, which is possible only by combining the K−p and the upcoming K−d results. An overview of the experimental results of SIDDHARTA and an outlook to SIDDHARTA-2 experiments are given in this paper.
  •  
17.
  • Hashimoto, T., et al. (författare)
  • Kaonic-Atom X-ray Spectroscopy with Superconducting Microcalorimeters
  • 2017
  • Ingår i: Proceedings of the 12th International Conference on Hypernuclear and Strange Particle Physics (HYP2015). - 9784890271221 ; 17
  • Konferensbidrag (refereegranskat)abstract
    • We will measure kaonic helium X-rays using transition-edge-sensor microcalorimeters, TES, in the J-PARC hadron experimental facility. To demonstrate the feasibility of the experiment, we performed a measurement of pionic carbon X-rays at PSI, where an excellent FWHM energy resolution of 7 eV at 6.4 keV was achieved. We also evaluated the expected TES performance in the kaon beam at J-PARC. The simulation results show that the TES spectrometer would work with a good energy resolution, and clear peaks of kaonic helium X-rays would be observed on a reasonably suppressed background.
  •  
18.
  •  
19.
  •  
20.
  • Hashimoto, T., et al. (författare)
  • Beamline test of a transition-edge-sensor spectrometer in preparation for kaonic-atom measurements
  • 2017
  • Ingår i: IEEE Transactions on Applied Superconductivity. - 1051-8223. ; 27:4
  • Tidskriftsartikel (refereegranskat)abstract
    • We are developing a new technique to apply transition-edge sensors (TESs) to X-ray spectroscopy of exotic atoms, especially of kaonic atoms. To demonstrate the feasibility of this pioneering project, performance of a TES-based X-ray detector was evaluated in pion- and kaon-beam environments at particle accelerators.We successfully observed X-rays from pionic-carbon atoms with a resolution as good as 7 eV FWHM at 6 keV. Also at a kaon beamline, we confirmed that the TES spectrometer will be able to achieve our resolution goal, 6 eV, in our first scientific campaign to measure X-rays from kaonic-helium atoms.
  •  
21.
  • Tatsuno, H., et al. (författare)
  • Future projects of light kaonic atom X-ray spectroscopy
  • 2016
  • Ingår i: EPJ Web of Conferences. - : EDP Sciences. - 2101-6275 .- 2100-014X. ; 130
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray spectroscopy of light kaonic atoms is a unique tool to provide precise information on the fundamental KN interaction at the low-energy limit and the in-medium nuclear interaction of K-. The future experiments of kaonic deuterium strong-interaction shift and width (SIDDHARTA-2 and J-PARC E57) can extract the isospin dependent K-N interaction at threshold. The high-resolution X-ray spectroscopy of kaonic helium with microcalorimeters (J-PARC E62) has the possibility to solve the long-standing potential-strength problem of the attractive K--nucleus interaction. Here, the recent experimental results and the future projects of X-ray spectroscopy of light kaonic atoms are presented.
  •  
22.
  • Anelli, M., et al. (författare)
  • Measurement and simulation of neutron detection efficiency in lead-scintillating fiber calorimeters
  • 2009
  • Ingår i: Nuclear physics B, Proceedings supplements. - : Elsevier BV. - 0920-5632 .- 1873-3832. ; 197:1, s. 353-357
  • Tidskriftsartikel (refereegranskat)abstract
    • The overall detection efficiency to neutrons of a small prototype of the KLOE lead-scintillating fiber calorimeter has been measured at the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala, in the kinetic energy range [5-175] MeV. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 30% to 50%. This value largely exceeds the estimated 8-15% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beam line has been performed with the FLUKA Monte Carlo code. First data-MC comparisons are encouraging and allow to disentangle a neutron halo component in the beam.
  •  
23.
  • Anelli, M., et al. (författare)
  • Measurement and simulation of the neutron response and detection efficiency of a Pb-scintillating fiber calorimeter
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 581:1-2, s. 368-372
  • Tidskriftsartikel (refereegranskat)abstract
    • The overall detection efficiency to neutrons of a small prototype of the KLOE Pb-scintillating fiber calorimeter has been measured at the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala, in the kinetic energy range 5-175 MeV. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 40% to 50%. This value largely exceeds the estimated 8-16% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beamline has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented, as well as a first data Monte Carlo comparison. The results show an overall neutron efficiency of about 50%, when no trigger threshold is applied. The reasons of such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.
  •  
24.
  • Anelli, M., et al. (författare)
  • Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters
  • 2010
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 617:1-3, s. 107-108
  • Tidskriftsartikel (refereegranskat)abstract
    • We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. We show preliminary measurement carried out with a different prototype with a larger lead/fiber ratio, which proves the relevance of passive material to neutron detection efficiency in this kind of calorimeters.
  •  
25.
  • Anelli, M., et al. (författare)
  • Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 598:1, s. 244-247
  • Tidskriftsartikel (refereegranskat)abstract
    • A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration.
  •  
26.
  • Anelli, M., et al. (författare)
  • Measurement of the neutron detection efficiency of a 80% absorber-20% scintillating fibers calorimeter
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 626, s. 67-71
  • Tidskriftsartikel (refereegranskat)abstract
    • The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.
  •  
27.
  •  
28.
  • Okada, S., et al. (författare)
  • First application of superconducting transition-edge sensor microcalorimeters to hadronic atom X-ray spectroscopy
  • 2016
  • Ingår i: Progress of Theoretical and Experimental Physics. - : Oxford University Press (OUP). - 2050-3911. ; 2016:9
  • Tidskriftsartikel (refereegranskat)abstract
    • High-resolution pionic atom X-ray spectroscopy was performed with an X-ray spectrometer based on a 240 pixel array of superconducting transition-edge sensor (TES) microcalorimeters at the φM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f → 3d transition and the parallel 4d → 3p transition were observed with a full width at half maximum energy resolution of 6.8 eV at 6.4 keV. The measured X-ray energies are consistent with calculated electromagnetic values which considered the strong interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic atom X-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic atom X-ray spectroscopy.
  •  
29.
  •  
30.
  • Anelli, A., et al. (författare)
  • Measurement and simulation of the neutron response and detection efficiency of a Pb-scintillating fiber calorimeter
  • 2008
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 55:3, s. 1409-1412
  • Tidskriftsartikel (refereegranskat)abstract
    • We have measured the overall detection efficiency to neutrons of a small prototype of the KLOE Pb-scintillating fiber calorimeter in the kinetic energy range [5,175] MeV. using the neutron beam facility of The Svedberg Laboratory, TSL, Uppsala. The measurement of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 28% to 33%. This value largely exceeds the estimated similar to 8% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beamline has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented together with first data to Monte Carlo comparison. The results show an overall neutron efficiency of about 35%. The reasons for such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.
  •  
31.
  • Chioncel, Ovidiu, et al. (författare)
  • Epidemiology, pathophysiology and contemporary management of cardiogenic shock - a position statement from the Heart Failure Association of the European Society of Cardiology
  • 2020
  • Ingår i: European Journal of Heart Failure. - : WILEY. - 1388-9842 .- 1879-0844. ; 22:8, s. 1315-1341
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiogenic shock (CS) is a complex multifactorial clinical syndrome with extremely high mortality, developing as a continuum, and progressing from the initial insult (underlying cause) to the subsequent occurrence of organ failure and death. There is a large spectrum of CS presentations resulting from the interaction between an acute cardiac insult and a patients underlying cardiac and overall medical condition. Phenotyping patients with CS may have clinical impact on management because classification would support initiation of appropriate therapies. CS management should consider appropriate organization of the health care services, and therapies must be given to the appropriately selected patients, in a timely manner, whilst avoiding iatrogenic harm. Although several consensus-driven algorithms have been proposed, CS management remains challenging and substantial investments in research and development have not yielded proof of efficacy and safety for most of the therapies tested, and outcome in this condition remains poor. Future studies should consider the identification of the new pathophysiological targets, and high-quality translational research should facilitate incorporation of more targeted interventions in clinical research protocols, aimed to improve individual patient outcomes. Designing outcome clinical trials in CS remains particularly challenging in this critical and very costly scenario in cardiology, but information from these trials is imperiously needed to better inform the guidelines and clinical practice. The goal of this review is to summarize the current knowledge concerning the definition, epidemiology, underlying causes, pathophysiology and management of CS based on important lessons from clinical trials and registries, with a focus on improving in-hospital management.
  •  
32.
  •  
33.
  • Evers, Arne, et al. (författare)
  • Testing Practices and Attitudes Toward Tests and Testing : An International Survey
  • 2017
  • Ingår i: International Journal of Testing. - : ROUTLEDGE JOURNALS, TAYLOR & FRANCIS LTD. - 1530-5058 .- 1532-7574. ; 17:2, s. 158-190
  • Tidskriftsartikel (refereegranskat)abstract
    • On behalf of the International Test Commission and the European Federation of Psychologists' Associations a world-wide survey on the opinions of professional psychologists on testing practices was carried out. The main objective of this study was to collect data for a better understanding of the state of psychological testing worldwide. These data could guide the actions and measures taken by ITC, EFPA, and other stakeholders. A questionnaire was administered to 20,467 professional psychologists from 29 countries. Five scales were constructed relating to: concern over incorrect test use, regulations on tests and testing, internet and computerized testing, appreciation of tests, and knowledge and training relating to test use. Equivalence across countries was evaluated using the alignment method, four scales demonstrated acceptable levels of invariance. Multilevel analysis was used to determine how scores were related to age, gender, and specialization, as well as how scores varied between countries. Although the results show a high appreciation of tests in general, the appreciation of internet and computerized testing is much lower. These scales show low variability over countries, whereas differences between countries on the other reported scales are much greater. This implies the need for some overarching improvements as well as country-specific actions.
  •  
34.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-34 av 34

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy