1.
  • Eriksson, Lars-Gunnar, et al. (författare)
  • Massive Postpartum Hemorrhage Treated with Transcatheter Arterial Embolization : Technical aspects and long-term effects on fertility and menstrual cycle
  • 2007
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 48:6, s. 635-642
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Transcatheter arterial embolization (TAE) is considered a safe, life-saving procedure in postpartum hemorrhage (PPH), but its long-term effect on menstruation and fertility is unclear. Purpose: To investigate technical aspects and the evaluation of complications, focused on menstrual cycle and fertility, using TAE in patients with PPH. Material and Methods: A retrospective study including 20 patients (seven with vaginal and 13 with cesarean delivery) with severe PPH treated with bilateral TAE of the uterine artery was carried out. All patients were asked to answer a questionnaire regarding their post-embolization history. In six patients, the radiation dose was measured. Results: All 20 cases underwent bilateral TAE of the uterine artery. Gelfoam was used as the embolic agent. However, after cesarean delivery in six patients who had clear contrast medium extravasation and/or pseudoaneurysm-like lesion, metallic coils had to be used in order to achieve hemostasis. No major short- or long-term complications were registered. Normal menses resumed in all patients. Four patients had a total of five full-term and two preterm pregnancies, and all delivered healthy infants by cesarean section with no recurrence of PPH. The mean radiation dose to the ovaries was 586 mGy (range 204-729 mGy). Conclusion: TAE in patients with PPH is safe and has no major short- or long-term side effects. A patient managed with TAE can expect return of normal menses and preservation of future fertility and successful pregnancies. PPH after cesarean section might need to be embolized with metallic coils in addition to Gelfoam in order to achieve secure hemostasis.
  •  
2.
  • Borota, Ljubisa, et al. (författare)
  • Spot fluoroscopy : a novel innovative approach to reduce radiation dose in neurointerventional procedures
  • 2017
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 58:5, s. 600-608
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Increased interest in radiation dose reduction in neurointerventional procedures has led to the development of a method called "spot fluoroscopy" (SF), which enables the operator to collimate a rectangular or square region of interest anywhere within the general field of view. This has potential advantages over conventional collimation, which is limited to symmetric collimation centered over the field of view.PURPOSE: To evaluate the effect of SF on the radiation dose.MATERIAL AND METHODS: Thirty-five patients with intracranial aneurysms were treated with endovascular coiling. SF was used in 16 patients and conventional fluoroscopy in 19. The following parameters were analyzed: the total fluoroscopic time, the total air kerma, the total fluoroscopic dose-area product, and the fluoroscopic dose-area product rate. Statistical differences were determined using the Welch's t-test.RESULTS: The use of SF led to a reduction of 50% of the total fluoroscopic dose-area product (CF = 106.21 Gycm(2), SD = 99.06 Gycm(2) versus SF = 51.80 Gycm(2), SD = 21.03 Gycm(2), p = 0.003884) and significant reduction of the total fluoroscopic dose-area product rate (CF = 1.42 Gycm(2)/min, SD = 0.57 Gycm(2)/s versus SF = 0.83 Gycm(2)/min, SD = 0.37 Gycm(2)/min, p = 0.00106). The use of SF did not lead to an increase in fluoroscopy time or an increase in total fluoroscopic cumulative air kerma, regardless of collimation.CONCLUSION: The SF function is a new and promising tool for reduction of the radiation dose during neurointerventional procedures.
  •  
3.
  • Dahlman, Pär, et al. (författare)
  • Optimization of computed tomography urography protocol, 1997 to 2008 : effects on radiation dose
  • 2009
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 50:4, s. 446-454
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Since computed tomography (CT) urography began to replace excretory urography as the primary imaging technique in uroradiology, the collective radiation dose to the patients has increased. PURPOSE: To examine the changes in the CT urography protocol for investigating suspected urinary tract malignancy between the years 1997 and 2008, and how these changes have influenced the mean effective dose. MATERIAL AND METHODS: The study was based on 102 patients (mean age 66.1+/-14.8 years, range 31-89 years; 30 female, 72 male) divided into five groups (groups A-E) corresponding to the time points at which changes were made to the CT urography protocol. The mean effective doses were estimated using the ImPACT CT Patient Dosimetry Calculator. RESULTS: The number of scan phases at CT urography was reduced from four to three in 1999, resulting in a reduction of the mean effective dose from 29.9/22.5 (female [F]/male [M]) mSv (group A) to 26.1/18.9 (F/M) mSv (group B). In 2001, mAs settings were adapted to patient size, and the mean effective dose was reduced to 16.8/12.0 (F/M) mSv (group C). In 2005, scans were performed with a multidetector-row CT equipped with automatic tube current modulation in the x- and y-axis (CARE Dose). The effective mAs was also lowered in the unenhanced and excretory phase, yet the mean effective dose increased to 18.2/13.1 (F/M) mSv (group D), since the effective mAs had to be increased in the corticomedullary phase to maintain image quality. In 2008, as tube current modulation in the x-, y-, and z-axis was introduced (CARE Dose4D), the mean effective dose was reduced to 11.7/8.8 (F/M) mSv (group E). CONCLUSION: This study shows that the individual mean effective dose to patients undergoing CT urography has decreased by 60%, from 29.9/22.5 (F/M) mSv in 1997 to 11.7/8.8 (F/M) mSv in 2008.
  •  
4.
  •  