SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Jebali R) "

Sökning: WFRF:(Jebali R)

  • Resultat 1-27 av 27
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Rofors, E., et al. (författare)
  • Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
  • 2020
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 984
  • Tidskriftsartikel (refereegranskat)abstract
    • The response of a position-sensitive Li-glass based scintillation detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using focused beams of 2.5MeV protons and deuterons. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 × 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. To optimize planned detector operation at the European Spallation Source, the number of pixels above set thresholds was investigated, with the maximization of the single-hit efficiency over the largest possible area as the primary goal. For both beams, at a threshold of ∼50% of the mean of the full-deposition peak, ∼80% of the events were registered in a single pixel, resulting in an effective position resolution of ∼5 mm in X and Y. Lower thresholds resulted in higher pixel multiplicities. These events could also be localized with the same effective position resolution.
  •  
2.
  • Backis, A., et al. (författare)
  • Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors
  • 2021
  • Ingår i: Measurement science and technology. - : IOP PUBLISHING LTD. - 0957-0233 .- 1361-6501. ; 32:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The boron-10 based multi-grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron energies. The objective of this work is to investigate fine time- and energy-resolved effects of the Multi-Grid detector, down to a few mu eV, while comparing it to the performance of a typical helium-3 tube. Furthermore, it is to characterize differences between the detector technologies in terms of internal scattering, as well as the time reconstruction of similar to mu s short neutron pulses. The data were taken at the Helmholtz Zentrum Berlin, where the Multi-Grid detector and a helium-3 tube were installed at the ESS test beamline, V20. Using a Fermi-chopper, the neutron beam of the reactor was chopped into a few tens of mu s wide pulses before reaching the detector, located a few tens of cm downstream. The data of the measurements show an agreement between the derived and calculated neutron detection efficiency curve. The data also provide fine details on the effect of internal scattering, and how it can be reduced. For the first time, the chopper resolution was comparable to the timing resolution of the Multi-Grid detector. This allowed a detailed study of time- and energy resolved effects, as well as a comparison with a typical helium-3 tube.
  •  
3.
  • Rofors, E., et al. (författare)
  • Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams
  • 2021
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 999
  • Tidskriftsartikel (refereegranskat)abstract
    • The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 × 8 pixel multi-anode photomultiplier tube on an event-by-event basis. In general, several pixels registered large signals at each neutron-beam location. The number of pixels registering signal above a set threshold was investigated, with the maximization of the single-hit efficiency over the largest possible area of the detector as the primary goal. At a threshold of ∼50% of the mean of the full-deposition peak, ∼80% of the events were registered in a single pixel, resulting in an effective position resolution of ∼5 mm in X and Y. Lower thresholds generally resulted in events demonstrating higher pixel multiplicities, but these events could also be localized with ∼5 mm position resolution.
  •  
4.
  • Rofors, E., et al. (författare)
  • Response of a Li-glass/multi-anode photomultiplier detector to α-particles from 241 Am
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 929, s. 90-96
  • Tidskriftsartikel (refereegranskat)abstract
    • The response of a position-sensitive Li-glass scintillator detector to α-particles from a collimated 241 Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 × 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.
  •  
5.
  • Wang, J., et al. (författare)
  • Final report of the CCQM-K145 : Toxic and essential elements in bovine liver
  • 2020
  • Ingår i: Metrologia. - : IOP Publishing Ltd. - 0026-1394 .- 1681-7575. ; 57:1 A
  • Tidskriftsartikel (refereegranskat)abstract
    • Liver plays a major role in metabolism and acts as a source of energy for the body by storing glycogen. With the growing interest and investigation in the biological effects in recent years, it is important and necessary to develop accurate and comparable analytical methods for elements in bio-samples. It has, however, been 10 years since the tissue sample (bovine liver) of CCQM-K49 key comparison. The purpose of CCQM-K145 is to ensure the comparable and traceable measurement results for essential and toxic elements such as P, S, Zn, Mn, Ni, Mo, Sr, Cr, Co, Pb, As and Hg in bovine liver among NMIs and other designated measurement bodies worldwide. The comparison was agreed by IAWG as 6th IAWG Benchmarking Exercise with Zn and Ni as exemplary elements at the meeting in Korea in the early October 2016. The results of CCQM-K145 are expected to cover the measurement capability and support CMCs claiming for inorganic elements in the similar biological tissue materials and food samples. 30 NMIs and DIs registered in CCQM-K145. With respect to the methodology, a variety of techniques such as IDMS, ICP-OES, ICP-MS(non-ID), AAS and NAA were adopted by the participants. For Zn, Ni, Sr, Pb and Hg measurements, most participants chose ID-ICP-MS method, which showed the better performance in terms of consistency and reliability of the measurement results. In aspect of the traceability for the measurement results in CCQM-K145, most participants used their own (in house) CRMs or other NMI's CRMs to guarantee trace to SI unit. Most participants used similar matrix CRMs for quality control or method validation. Base on different statistic way to calculate the reference mass fraction values and associated uncertainties for each measurand, removal of the suspected extreme values, and discussion at the IAWG meetings, the median values are proposed as the KCRV for Zn, Ni, Mn, Mo, Cr, Pb and Hg; the arithmetic mean values are proposed as the KCRV for P, S, Sr, Co and As. In general, the performances of the majority of CCQM-K145 participants are very good, illustrating their measurement capabilities for Zn, Ni, P, S, Mn, Mo, Sr, Cr, As, Co, Pb and Hg in a complex biological tissue matrix. Bovine liver contains many kinds of nutrients and microelements, it can be regarded as a typical representative material of biological tissue and food. In CCQM-K145, the analytes involved alkali metals and transition elements, metalloids/semi-metals and non metals with a range of mass fraction from mg/g to μg/kg. CCQM-K145 also tested the ability of NMIs/DIs to determine elements that were easy to be lost and polluted, and interfered significantly. The chemical pretreatment methods of samples used in the comparison is suitable for general food and biological matrix samples. A variety of measurement methods used in the comparison represent the main instrumental technology for elemental analysis. Therefore, for supporting CMC claim, CCQM-K145 is readily applicable to measurement of more elements in a wide range of biological materials (including liquids and solids) and meat products. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
  •  
6.
  • Boyd, L., et al. (författare)
  • Simulation of the response of the Solid State Neutron Detector for the European Spallation Source
  • 2021
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 998
  • Tidskriftsartikel (refereegranskat)abstract
    • The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interactions of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, scintillation photons through the scintillator, en route to the photocathode of the attached multi-anode photomultiplier. Factors which affect the optical-photon transport, such as surface finish, pixelation of the glass sheet, provision of a front reflector and optical coupling media are compared. Predictions of the detector response are compared with measurements made with neutron and gamma-ray sources, a collimated alpha source and finely collimated beams of 2.5 MeV protons and deuterons.
  •  
7.
  • Mauritzson, N., et al. (författare)
  • Light-yield response of liquid scintillators using 2–6 MeV tagged neutrons
  • 2024
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - 0168-9002. ; 1062
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2–6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT4 model to locate the edge positions of the Compton distributions produced by gamma-ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time-of-flight. This resulted in an energy-dependent Birks parameterization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented.
  •  
8.
  • Mauritzson, N., et al. (författare)
  • Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons
  • 2022
  • Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1039
  • Tidskriftsartikel (refereegranskat)abstract
    • Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray events was analyzed by integrating selected portions of the digitized waveform to produce a figure-of-merit for neutron/gamma-ray separation. This figure-of-merit has been mapped as a function of detector threshold and also of neutron energy determined from time-of-flight. It shows clearly that the well-established pulse-shape discrimination capabilities of NE 213A are superior to those of EJ 305. The extra information provided by the neutron-tagging technique has resulted in a far more detailed assessment of the pulse-shape-discrimination capabilities of these organic scintillators.
  •  
9.
  • Rofors, E., et al. (författare)
  • Response of a Li-glass/multi-anode photomultiplier detector to alpha-particles from Am-241
  • 2019
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 929, s. 90-96
  • Tidskriftsartikel (refereegranskat)abstract
    • The response of a position-sensitive Li-glass scintillator detector to alpha-particles from a collimated Am-241 source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 x 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.
  •  
10.
  • Jebali, R., et al. (författare)
  • A first comparison of the responses of a He-4-based fast-neutron detector and a NE-213 liquid-scintillator reference detector
  • 2015
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 794, s. 102-108
  • Tidskriftsartikel (refereegranskat)abstract
    • A first comparison has been made between the pulse-shape discrimination characteristics of a novel He-4-based pressurized scintillation detector and a NE-213 liquicl-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays were investigated. The NE-213 liquicl-scintillator reference cell produced a wide range of scintillation-light yields in response to he gamma-ray field of the source. In stark contrast, clue to the size and pressure of the He-4 gas volume, the He-4-based detector registered a maximum scintillation-light yield of 750 keV(ee) to the same gamma-ray field. Pulse-shape discrimination for particles with scintillation-light yields of more than 750 keV(ee) was excellent in the case of the He-4-based detector. Above 750 keV(ee) its signal was unambiguously neutron, enabling particle identification based entirely upon the amount of scintillation light produced. (C) 2015 The Authors. Published by Elsevier B.V.
  •  
11.
  • Mauritzson, N., et al. (författare)
  • Light-yield response of liquid scintillators using 2-6 MeV tagged neutrons
  • 2024
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 1062
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge of the neutron light -yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2-6 MeV have been used to study the scintillation light -yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event -by -event waveform digitization. Energy calibration was performed using a GEANT4 model to locate the edge positions of the Compton distributions produced by gamma -ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time -of -flight. This resulted in an energy -dependent Birks parameterization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented.
  •  
12.
  • Messi, F., et al. (författare)
  • The neutron-tagging facility at Lund University
  • 2020
  • Ingår i: Modern Neutron Detection : Proceedings of a Technical Meeting - Proceedings of a Technical Meeting. - 1011-4289. - 9789201265203 - 9789201266200 ; :1935, s. 287-297
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation process is in general long and expensive. The study of detector prototypes using neutron-emitting radioactive sources is a cost-effective solution, especially for preliminary investigations. That said, neutron-emitting sources have the general disadvantage of broad, structured, emitted-neutron energy ranges. Further, the emitted neutrons often compete with unwanted backgrounds of gamma-rays, alpha-particles, and fission-fragments. By blending experimental infrastructure such as shielding to provide particle beams with neutron-detection techniques such as tagging, disadvantages may be converted into advantages. In particular, a technique known as tagging involves exploiting the mixed-field generally associated with a neutron-emitting source to determine neutron time-of-flight and thus energy on an event-by-event basis. This allows for the definition of low-cost, precision neutron beams. The Source-Testing Facility, located at Lund University in Sweden and operated by the SONNIG Group of the Division of Nuclear Physics, was developed for just such low-cost studies. Precision tagged-neutron beams derived from radioactive sources are available around-the-clock for advanced detector diagnostic studies. Neutron measurements performed at the Source Testing Facility are thus cost-effective and have a very low barrier for entry. In this paper, we present an overview of the project.
  •  
13.
  • Myers, L. S., et al. (författare)
  • Compton scattering from C-12 using tagged photons in the energy range 65-115 MeV
  • 2014
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 89:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Elastic scattering of photons from C-12 has been investigated using quasimonoenergetic tagged photons with energies in the range 65-115 MeV at laboratory angles of 60 degrees, 120 degrees, and 150 degrees. at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the C-12(gamma,gamma)C-12 cross section to the bound- nucleon polarizabilities.
  •  
14.
  • Myers, L S, et al. (författare)
  • Measurement of compton scattering from the deuteron and an improved extraction of the neutron electromagnetic polarizabilities.
  • 2014
  • Ingår i: Physical Review Letters. - 1079-7114. ; 113:26
  • Tidskriftsartikel (refereegranskat)abstract
    • The electromagnetic polarizabilities of the nucleon are fundamental properties that describe its response to external electric and magnetic fields. They can be extracted from Compton-scattering data-and have been, with good accuracy, in the case of the proton. In contradistinction, information for the neutron requires the use of Compton scattering from nuclear targets. Here, we report a new measurement of elastic photon scattering from deuterium using quasimonoenergetic tagged photons at the MAX IV Laboratory in Lund, Sweden. These first new data in more than a decade effectively double the world data set. Their energy range overlaps with previous experiments and extends it by 20 MeV to higher energies. An analysis using chiral effective field theory with dynamical Δ(1232) degrees of freedom shows the data are consistent with and within the world data set. After demonstrating that the fit is consistent with the Baldin sum rule, extracting values for the isoscalar nucleon polarizabilities, and combining them with a recent result for the proton, we obtain the neutron polarizabilities as α_{n}=[11.55±1.25(stat)±0.2(BSR)±0.8(th)]×10^{-4} fm^{3} and β_{n}=[3.65∓1.25(stat)±0.2(BSR)∓0.8(th)]×10^{-4} fm^{3}, with χ^{2}=45.2 for 44 degrees of freedom.
  •  
15.
  • Scherzinger, Julius, et al. (författare)
  • Tagging fast neutrons from an (241)Am/(9)Be source.
  • 2015
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043. ; 98, s. 74-79
  • Tidskriftsartikel (refereegranskat)abstract
    • Shielding, coincidence, and time-of-flight measurement techniques are employed to tag fast neutrons emitted from an (241)Am/(9)Be source resulting in a continuous polychromatic energy-tagged beam of neutrons with energies up to 7MeV. The measured energy structure of the beam agrees qualitatively with both previous measurements and theoretical calculations.
  •  
16.
  • Burdeinyi, D. D., et al. (författare)
  • Study of C12(γ→,p)11B reactions with polarized photons at energy 40-65 MeV
  • 2024
  • Ingår i: Nuclear Physics A. - 0375-9474. ; 1048
  • Tidskriftsartikel (refereegranskat)abstract
    • The photon beam asymmetry of the C12(γ→,p01)11B and C12(γ→,p2−6)11B reactions has been measured in the energy range 40–65 MeV, using a tagged, linearly-polarized photon beam at the MAX-lab facility in Sweden. The asymmetry of the C12(γ→,p01)11B reaction to ground and first excited state of B11 is Σ≈0.82 over the measured energy range. The main contribution to the C12(γ→,p2−6)11B reaction to higher excited states comes from processes in which the residual nucleus is in the 3/2−(5.02 MeV) or 7/2−(6.74 MeV) excited states. The asymmetry of this reaction is Σ≈0.6, close to the value for free deuteron photodisintegration.
  •  
17.
  • Myers, L. S., et al. (författare)
  • Compton scattering from the deuteron below pion-production threshold
  • 2015
  • Ingår i: Physical Review C (Nuclear Physics). - 0556-2813. ; 92:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Differential cross sections for elastic scattering of photons from the deuteron have recently been measured at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. These first new measurements in more than a decade further constrain the isoscalar electromagnetic polarizabilities of the nucleon and provide the first-ever results above 100 MeV, where the sensitivity to the polarizabilities is increased. We add 23 points between 70 and 112 MeV, at angles 60 degrees, 120 degrees, and 150 degrees. Analysis of these data using a chiral effective field theory indicates that the cross sections are both self-consistent and consistent with previous measurements. Extracted values of alpha(s) = [12.1 +/- 0.8(stat) +/- 0.2(BSR) +/- 0.8(th)] x 10(-4) fm(3) and beta(s) = [2.4 +/- 0.8(stat) +/- 0.2(BSR) +/- 0.8(th)] x 10(-4) fm(3) are obtained from a fit to these 23 new data points. This paper presents in detail the experimental conditions and the data analysis used to extract the cross sections.
  •  
18.
  • Preston, M. F., et al. (författare)
  • Tests of the Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory
  • 2014
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 744, s. 17-17
  • Tidskriftsartikel (refereegranskat)abstract
    • Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs. The agreement between results obtained from data taken using single-hit and multi-hit TDCs demonstrate a thorough understanding of the behavior of the detector system.
  •  
19.
  • Scherzinger, Julius, et al. (författare)
  • A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources
  • 2017
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 127, s. 98-102
  • Tidskriftsartikel (refereegranskat)abstract
    • Untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe mixed-field sources have been measured. Gamma-ray spectroscopy measurements from 1 to 5 MeV were performed in an open environment using a CeBr3 detector and the same experimental conditions for both sources. The shapes of the distributions are very similar and agree well with previous data. Tagged-neutron measurements from 2 to 6 MeV were performed in a shielded environment using a NE-213 liquid-scintillator detector for the neutrons and a YAP(Ce) detector to tag the 4.44 MeV gamma-rays associated with the de-excitation of the first-excited state of 12C. Again, the same experimental conditions were used for both sources. The shapes of these distributions are also very similar and agree well with previous data, each other, and the ISO recommendation. Our 238PuBe source provides approximately 2.6 times more 4.44 MeV gamma-rays and 2.4 times more neutrons over the tagged-neutron energy range, the latter in reasonable agreement with the original full-spectrum source-calibration measurements performed at the time of their acquisition.
  •  
20.
  • Scherzinger, Julius, et al. (författare)
  • Tagging fast neutrons from a Cf-252 fission-fragment source
  • 2017
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 128, s. 270-274
  • Tidskriftsartikel (refereegranskat)abstract
    • Coincidence and time-of-flight measurement techniques are employed to tag fission neutrons emitted from a Cf-252 source sealed on one side with a very thin layer of Au. The source is positioned within a gaseous He-4 scintillator detector. Together with a particles, both light and heavy fission fragments pass through the thin layer of Au and are detected. The fragments enable the corresponding fission neutrons, which are detected in a NE-213 liquid-scintillator detector, to be tagged. The resulting continuous polychromatic beam of tagged neutrons has an energy dependence that agrees qualitatively with expectations. We anticipate that this technique will provide a cost-effective means for the characterization of neutron-detector efficiency in the energy range 1-6 MeV.
  •  
21.
  • Scherzinger, J., et al. (författare)
  • Tagging fast neutrons from an 241Am/9Be source
  • 2015
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 98, s. 74-79
  • Tidskriftsartikel (refereegranskat)abstract
    • Shielding, coincidence, and time-of-flight measurement techniques are employed to tag fast neutrons emitted from an 241Am/9Be source resulting in a continuous polychromatic energy-tagged beam of neutrons with energies up to 7MeV. The measured energy structure of the beam agrees qualitatively with both previous measurements and theoretical calculations.
  •  
22.
  • Strandberg, B., et al. (författare)
  • Compton scattering from the deuteron above pion-production threshold
  • 2018
  • Ingår i: Physical Review C. - 2469-9985. ; 98:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The electromagnetic polarizabilities of the nucleon are fundamental nucleon-structure observables that characterize its response to external electromagnetic fields. The neutron polarizabilities can be accessed from Compton-scattering data on light nuclear targets. Recent measurements of the differential cross section for Compton scattering on the deuteron below the pion-production threshold have decreased the uncertainties in the neutron polarizabilities, yet the proton polarizabilities remain known substantially more accurately. As the sensitivity of the cross section to the polarizabilities increases with incident photon energy, measurements above the pion threshold may offer a way for an improved determination of the neutron polarizabilities. In this Rapid Communiciation, the first measurement of the cross section for coherent Compton scattering on the deuteron above the pion-production threshold is presented.
  •  
23.
  • Strandberg, B., et al. (författare)
  • Near-threshold π-photoproduction on the deuteron
  • 2020
  • Ingår i: Physical Review C. - 2469-9985. ; 101:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The first experimental investigation of the near-threshold cross section for incoherent π-photoproduction on the deuteron γd→π-pp is presented. The experimental technique involved detection of the ≈131 MeV γ ray resulting from the radiative capture of photoproduced π-in the target. The total cross section was measured using an unpolarized tagged-photon beam, a liquid-deuterium target, and three very large NaI(Tl) spectrometers. The data are compared to theoretical models that give insight into the elementary reaction γn→π-p and pion-nucleon and nucleon-nucleon final-state interactions.
  •  
24.
  • Al Jebali, Ramsey, et al. (författare)
  • A helium gas scintillator active target for photoreaction measurements
  • 2015
  • Ingår i: European Physical Journal A. Hadrons and Nuclei. - : Springer Science and Business Media LLC. - 1434-6001. ; 51:10
  • Tidskriftsartikel (refereegranskat)abstract
    • A multi-cell He gas scintillator active target, designed for the measurement of photoreaction cross sections, is described. The target has four main chambers, giving an overall thickness of 0.103 g/cm(3) at an operating pressure of 2MPa. Scintillations are read out by photomultiplier tubes and the addition of small amounts of N-2 to the He, to shift the scintillation emission from UV to visible, is discussed. First results of measurements at the MAX IV Laboratory tagged-photon facility show that the target has a timing resolution of around 1 ns and can cope well with a high-flux photon beam. The determination of reaction cross sections from target yields relies on a Monte Carlo simulation, which considers scintillation light transport, photodisintegration processes in He-4, background photon interactions in target windows and interactions of the reaction-product particles in the gas and target container. The predictions of this simulation are compared to the measured target response.
  •  
25.
  • Al Jebali, Ramsey, et al. (författare)
  • Recent Developments SoNDe High-Flux Detector Project
  • 2018
  • Ingår i: Recent Developments SoNDe High-Flux Detector Project.
  • Konferensbidrag (refereegranskat)abstract
    • New high-flux and high-brilliance neutron sources demand a higher count-rate capability in neutron detectors. In order to achieve that goal, the Solid-State Neutron Detector (SoNDe) project is developing a scintillation-based neutron detector. It will be capable of fully exploiting the available flux at small-angle neutron scattering (SANS) instruments at high brilliance sources, such as SKADI at the European Spallation Source (ESS). The read-out of the scintillator is based on a pixelized multi-anode PMT (MaPMT), where each pixel is treated separately. In addition to enabling higher achievable count-rates, one of the design goals was to develop a modular and scalable solution that can also be used in other instruments or even contexts, such as for laboratory setups. This has been achieved by combining the complete read-out electronics along with the MaPMT into modules that can be controlled and read-out individually via a network without additional any infrastructure. An overview of the present state of development and current test results is presented, highlighting the results of previously published project reports.
  •  
26.
  • Christensen, M. J., et al. (författare)
  • Software-based data acquisition and processing for neutron detectors at European Spallation Source-early experience from four detector designs
  • 2018
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 13:11
  • Tidskriftsartikel (refereegranskat)abstract
    • European Spallation Source (ESS) will deliver neutrons at high flux for use in diverse neutron scattering techniques. The neutron source facility and the scientific instruments will be located in Lund, and the Data Management and Software Centre (DMSC), in Copenhagen. A number of detector prototypes are being developed at ESS together with its European in-kind partners, for example: SoNDe, Multi-Grid, Multi-Blade and Gd-GEM. These are all position sensitive detectors but use different techniques for the detection of neutrons. Except for digitization of electronics readout, all neutron data is anticipated to be processed in software. This provides maximum flexibility and adaptability and allows deep inspection of the raw data for commissioning which will reduce the risk of starting up new detector technologies. But it also requires development of high performance software processing pipelines and optimized and scalable processing algorithms. This report provides a description of the ESS system architecture for the neutron data path. Special focus is on the interface between the detectors and DMSC which is based on UDP over Ethernet links. The report also describes the software architecture for detector data processing and the tools we have developed, which have proven very useful for efficient early experimentation, and can be run on a single laptop. Processing requirements for the SoNDe, Multi-Grid, Multi-Blade and Ge-GEM detectors are presented and compared to event processing rates archived so far.
  •  
27.
  • Mauritzson, Nicholai, et al. (författare)
  • GEANT4-based calibration of an organic liquid scintillator
  • 2022
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 1023
  • Tidskriftsartikel (refereegranskat)abstract
    • A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using bothmonoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultipliertube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. Theresulting Compton edges have been analyzed using a GEANT4 simulation of the detector which models boththe interactions of the ionizing radiation as well as the transport of scintillation photons. The simulation is calibrated and also compared to well-established prescriptions used to determine the Compton edges,resulting ultimately in light-yield calibration functions. In the process, the simulation-based method produced information on the gain and intrinsic pulse-height resolution of the detector. It also facilitated a previously inaccessible understanding of the systematic uncertainties associated with the calibration of the scintillation-light yield. The simulation-based method was also compared to well-established numerical prescriptions for locating the Compton edges. Ultimately, the simulation predicted as much as 17% lower light-yield calibrations than the prescriptions. These calibrations indicate that approximately 35% of the scintillation light associated with a given gamma-ray reaches the photocathode. It is remarkable how well two 50 year old prescriptions for calibrating scintillation-light yield in organic scintillators have stood the test of time.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-27 av 27

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.