SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Johnsson Åse Docent) "

Sökning: WFRF:(Johnsson Åse Docent)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • De Geer, Jakob, 1970- (författare)
  • On the use of computed tomography in cardiac imaging
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • BackgroundCardiac Computed Tomography Angiography (CCTA) is becoming increasingly useful in the work‐up of coronary artery disease (CAD). Several potential methods for increasing the diagnostic yield of cardiac CT are available.Purpose Study I: To investigate whether the use of a 2‐D, non‐linear adaptive noise reduction filter can improve CCTA image quality.Study II: To evaluate the variation in adenosine stress dynamic CT perfusion (CTP) blood flow as compared to stress 99mTc SPECT. Secondly, to compare the perfusion results from manual and automatic myocardial CTP segmentation.Study III: To evaluate the accuracy of non‐invasive, CCTA‐derived Fractional Flow Reserve (cFFR).Study IV: To evaluate the prognostic value of CCTA in terms of major adverse cardiac events (MACE).Materials and methodsStudy I: Single images from 36 consecutive CCTA exams performed with two different dose levels were used. Image quality in full dose, low‐dose and noise‐reduced low‐dose images was graded using visual grading analysis. Image noise was measured.Study II: CTP and SPECT were performed in 17 patients, and the variation in per AHA‐segment blood flow was evaluated and compared. CTP results from manual and automated image segmentation were compared.Study III: CCTA datasets from 21 patients were processed using cFFR software and the results compared to the corresponding invasively measured FFR (invFFR).Study IV: 1205 consecutive patients with chest pain of unknown origin underwent CCTA. Baseline data and data on subsequent MACE were retrieved from relevant registries. Survival, hazard ratios and the three‐year incidence of cardiac events and readmissions were calculated.Results Study I: There was significant improvement in perceived image quality for all criteria when the filter was applied, and a significant decrease in image noise.Study II: The correlation coefficients for CTP vs. SPECT were 0.38 and 0.41 (p<0.001, for manual and automated segmentation respectively. Mean per patient CTP blood flow in normal segments varied between 94‐183 ml/100 ml tissue/min for manual segmentation, and 104‐196 ml/100 ml tissue/min for automated segmentation. The Spearman rank correlation coefficient for manual vs. automated segmentation CTP was ρ = 0.88 (p<0.001) and the Intraclass Correlation Coefficient (ICC) was 0.93 (p<0.001).Study III: The Spearman rank correlation coefficient for cFFR vs. invFFR was ρ = 0.77 (p<0.001) and the ICC was 0.73 (p<0.001). Sensitivity, specificity, positive predictive value and negative predictive value for significant stenosis (FFR<0.80, per vessel) were 0.83, 0.76, 0.56 and 0.93 respectively.Study IV: The hazard ratio for non‐obstructive CAD vs. normal coronary arteries was 5.13 (95% C.I 1.03‐25.43, p<0.05), and 151.40 (95% C.I 37.03‐619.08, p<0.001) for obstructive CAD vs. normal coronary arteries. The three‐year incidence of MACE was 1.1% for patients with normal vessels on CCTA, 2.5% for patients with non‐obstructive CAD and 42.7% for patients with obstructive CAD (p<0.001).Conclusions:Study I: Image quality and noise levels of low dose images were significantly improved with the filter, even though the improvement was small compared to the image quality of the corresponding diastolic full‐dose images.Study II: Correlation between dynamic CTP and SPECT was positive but weak. There were large variations in CTP blood flow in normal segments on SPECT, rendering the definition of an absolute cut‐off value for normal vs. ischemic myocardium difficult. Manual and automatic segmentation were equally useful.Study III: The correlation between cFFR and invFFR was good, indicating that noninvasively estimated cFFR performs on a similar level as invasively measure FFR. Study IV: The long‐term risk for MACE was very low in patients without obstructive CAD on CCTA, though there seemed to be a substantial increase in the risk for MACE even in patients with non‐obstructive CAD as compared to normal coronary arteries. In addition, even patients with normal coronary arteries or non‐obstructive CAD continued to have a substantial number of readmissions for chest pain or angina pectoris.
  •  
2.
  • Kihlberg, Johan, 1970- (författare)
  • Magnetic Resonance Imaging of Myocardial Deformation and Scarring in Coronary Artery Disease.
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Although improved treatments have reduced the rates of acute complications from myocardial infarction, sequelae such as heart failure and sudden death threaten the future wellbeing of those patients. Secondary prevention after myocardial infarction is related to cardiovascular risk factors and the effect of the infarct on left ventricular function. Cardiovascular magnetic resonance imaging (CMR) is necessary to determine the size of the infarct scar and can with great precision determine left ventricular volumes, left ventricular ejection fraction, and deformation (strain and torsion). The purpose of this thesis was to improve on CMR methods to facilitate image acquisition and post processing in patients with high risk of coronary artery disease (CAD).In Paper 1, a three-dimensional phase-sensitive inversion-recovery (3D PSIR) sequence was modified to measure T1 during a single breath hold. The measured T1 values were used to extrapolate a map of T1 relaxation, which avoided the time-consuming manual determination of the inversion time. The data collection consisted of phantom experiments, Monte Carlo simulations of the effect of various heart rates, and clinical investigation of 18 patients with myocardial infarction. Scar images created with the modified sequence were compared to those created with the standard sequence. The 3D PSIR sequence was able to measure T1 relaxation with a high accuracy up to 800 ms, which is in the suitable range for scar imaging. Simulated arrhythmias showed that the method was robust and able to tolerate some variation in heart rate. The modified sequence provides measurements of inversion time that can be used to facilitate standard scar imaging or to reconstruct synthetic scar images. Images of infarct scar obtained with the 3D PSIR sequence bore striking similarity to images obtained with the standard sequence.In Paper 2, 125 patients with high risk of CAD were investigated using the displacement encoding with stimulated echoes (DENSE) sequence. Image segments with infarct scar area >50% (transmurality) could be identified with a sensitivity of 95% and a specificity of 80% based on circumferential strain calculated from the DENSE measurements. The DENSE sequence was also applied in other directions, but its sensitivity and specificity to detect scar was lower than when used for circumferential strain.In Paper 3, 90 patients with high risk of CAD were examined by DENSE, tagging with harmonic phase (HARP) imaging and cine imaging with feature tracking (FT), to detect cardiac abnormalities as manifested in end-systolic circumferential strain. Circumferential strain calculated with DENSE had higher sensitivity and specificity than the competing methods to detect infarction with transmurality >50%. Global circumferential strain measured by DENSE correlated better with global parameters such as left ventricular ejection fraction, myocardial wall mass, left ventricular end-diastolic and end-systolic volume; than strain measured by FT or HARP.In Paper 4, myocardial torsion was investigated using DENSE, HARP, and FT in 48 patients with high risk of CAD. Torsion measured by each of the three methods was correlated with other global measures such as left ventricular ejection fraction, left ventricular mass, and left ventricular end-diastolic and end-systolic volumes. The torsion measurements obtained with DENSE had a stronger relationship with left ventricular ejection fraction, left ventricular mass, and volumes than those obtained with HARP or FT.DENSE was superior to the other methods for strain and torsion measurement and can be used to describe myocardial deformation quantitatively and objectively.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy