  • Folkesson, Joakim, et al. (författare)
  • Rectal cancer survival in the Nordic countries and Scotland
  • 2009
  • Ingår i: International Journal of Cancer. - : Wiley. - 0020-7136 .- 1097-0215. ; 125:10, s. 2406-12
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to present detailed population-based survival estimates for patients with a rectal adenocarcinoma, using cancer register data supplemented with clinical data. Based on cancer register data, differences in rectal cancer survival have been reported between countries in Europe. Variation in the distribution of stage at diagnosis, initial therapy including surgical technique, and comorbidity are possible explanatory factors. Adenocarcinomas in the rectum, diagnosed in 1997 and identified in the national cancer registries in the Nordic countries and Scotland were included. Age standardized 5-year relative survival and multiplicative regression models for the relative excess mortality were calculated. 3888 patients were included in the survival study. Men in Denmark, Finland and Iceland had lower 5-year relative survival and poorer stage distribution compared to Norway, Sweden and Scotland. Danish men had the highest rate of excess deaths in the first six months after diagnosis. Stage adjusted, the elevated relative excess mortality decreased and after six months the excess mortality rates were the same in all countries. The poor 5-year relative survival in Danish men was mainly due to a high excess rate of death during the first six months after diagnosis. The low survival in Finland and Iceland was not in accordance with other periods. For both countries this may be explained by random variation due to small numbers. The study emphasizes the need for high quality and detailed data in order to understand international survival differences, and cautions comparisons between large national samples and those of smaller areas.
  •  
2.
  • Adjeiwaah, Mary, 1980-, et al. (författare)
  • Dosimetric Impact of MRI Distortions : A Study on Head and Neck Cancers
  • 2019
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier. - 0360-3016 .- 1879-355X. ; 103:4, s. 994-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To evaluate the effect of magnetic resonance (MR) imaging (MRI) geometric distortions on head and neck radiation therapy treatment planning (RTP) for an MRI-only RTP. We also assessed the potential benefits of patient-specific shimming to reduce the magnitude of MR distortions for a 3-T scanner.Methods and Materials: Using an in-house Matlab algorithm, shimming within entire imaging volumes and user-defined regions of interest were simulated. We deformed 21 patient computed tomography (CT) images with MR distortion fields (gradient nonlinearity and patient-induced susceptibility effects) to create distorted CT (dCT) images using bandwidths of 122 and 488 Hz/mm at 3 T. Field parameters from volumetric modulated arc therapy plans initially optimized on dCT data sets were transferred to CT data to compute a new plan. Both plans were compared to determine the impact of distortions on dose distributions.Results: Shimming across entire patient volumes decreased the percentage of voxels with distortions of more than 2 mm from 15.4% to 2.0%. Using the user-defined region of interest (ROI) shimming strategy, (here the Planning target volume (PTV) was the chosen ROI volume) led to increased geometric for volumes outside the PTV, as such voxels within the spinal cord with geometric shifts above 2 mm increased from 11.5% to 32.3%. The worst phantom-measured residual system distortions after 3-dimensional gradient nonlinearity correction within a radial distance of 200 mm from the isocenter was 2.17 mm. For all patients, voxels with distortion shifts of more than 2 mm resulting from patient-induced susceptibility effects were 15.4% and 0.0% using bandwidths of 122 Hz/mm and 488 Hz/mm at 3 T. Dose differences between dCT and CT treatment plans in D-50 at the planning target volume were 0.4% +/- 0.6% and 0.3% +/- 0.5% at 122 and 488 Hz/mm, respectively.Conclusions: The overall effect of MRI geometric distortions on data used for RTP was minimal. Shimming over entire imaging volumes decreased distortions, but user-defined subvolume shimming introduced significant errors in nearby organs and should probably be avoided.
  •  
3.
  • Adjeiwaah, Mary, et al. (författare)
  • Quantifying the Effect of 3T Magnetic Resonance Imaging Residual System Distortions and Patient-Induced Susceptibility Distortions on Radiation Therapy Treatment Planning for Prostate Cancer
  • 2018
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier. - 0360-3016 .- 1879-355X. ; 100:2, s. 317-324
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the effect of magnetic resonance system- and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers.Methods and Materials: Combined displacement fields from the residual system and patient-induced susceptibility distortions were used to distort 17 prostate patient CT images. VMAT dose plans were initially optimized on distorted CT images and the plan parameters transferred to the original patient CT images to calculate a new dose distribution.Results: Maximum residual mean distortions of 3.19 mm at a radial distance of 25 cm and maximum mean patient-induced susceptibility shifts of 5.8 mm were found using the lowest bandwidth of 122 Hz per pixel. There was a dose difference of <0.5% between distorted and undistorted treatment plans. The 90% confidence intervals of the mean difference between the dCT and CT treatment plans were all within an equivalence interval of (−0.5, 0.5) for all investigated plan quality measures.Conclusions: Patient-induced susceptibility distortions at high field strengths in closed bore magnetic resonance scanners are larger than residual system distortions after using vendor-supplied 3-dimensional correction for the delineated regions studied. However, errors in dose due to disturbed patient outline and shifts caused by patient-induced susceptibility effects are below 0.5%.
  •  
4.
  • Bhalerao, Rupali, et al. (författare)
  • Gene expression in autumn leaves
  • 2003
  • Ingår i: Plant Physiology. - : Oxford University Press (OUP). - 0032-0889 .- 1532-2548. ; 131:2, s. 430-442
  • Tidskriftsartikel (refereegranskat)abstract
    • Two cDNA libraries were prepared, one from leaves of a field-grown aspen (Populus tremula) tree, harvested just before any visible sign of leaf senescence in the autumn, and one from young but fully expanded leaves of greenhouse-grown aspen (Populus tremula X tremuloides). Expressed sequence tags (ESTs; 5,128 and 4,841, respectively) were obtained from the two libraries. A semiautomatic method of annotation and functional classification of the ESTs, according to a modified Munich Institute of Protein Sequences classification scheme, was developed, utilizing information from three different databases. The patterns of gene expression in the two libraries were strikingly different. In the autumn leaf library, ESTs encoding metallothionein, early light-inducible proteins, and cysteine proteases were most abundant. Clones encoding other proteases and proteins involved in respiration and breakdown of lipids and pigments, as well as stress-related genes, were also well represented. We identified homologs to many known senescence-associated genes, as well as seven different genes encoding cysteine proteases, two encoding aspartic proteases, five encoding metallothioneins, and 35 additional genes that were up-regulated in autumn leaves. We also indirectly estimated the rate of plastid protein synthesis in the autumn leaves to be less that 10% of that in young leaves.
  •  
5.
  • Engström, Joakim, et al. (författare)
  • Physiological changes associated with routine nursing procedures in critically ill are common : an observational pilot study
  • 2017
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 61:1, s. 62-72
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Nursing procedures that are routinely performed in the intensive care unit (ICU) are assumed to have minimal side effects. However, these procedures may sometimes cause physiological changes that negatively affect the patient. We hypothesized that physiological changes associated with routine nursing procedures in the ICU are common.METHODS: A clinical observational study of 16 critically ill patients in a nine-bed mixed university hospital ICU. All nursing procedures were observed, and physiological data were collected and subsequently analyzed. Minor physiological changes were defined as minimal changes in respiratory or circulatory variables, and major physiological changes were marked as hyper/hypotension, bradycardia/tachycardia, bradypnea/tachypnea, ventilatory distress, and peripheral blood oxygen desaturation.RESULTS: In the 16 patients, 668 procedures generated 158 major and 692 minor physiological changes during 187 observational hours. The most common procedure was patient position change, which also generated the majority of the physiological changes. The most common major physiological changes were blood oxygen desaturation, ventilatory distress, and hypotension, and the most common minor changes were arterial pressure alteration, coughing, and increase in respiratory rate.CONCLUSION: In this pilot study, we examined physiological changes in connection with all regular routine nursing procedures in the ICU. We found that physiological changes were common and sometimes severe.
  •  
6.
  • Jonsson, Joakim H., et al. (författare)
  • Accuracy of inverse treatment planning on substitute CT images derived from MR data for brain lesions
  • 2015
  • Ingår i: Radiation Oncology. - : Springer Science and Business Media LLC. - 1748-717X. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In this pilot study we evaluated the performance of a substitute CT (s-CT) image derived from MR data of the brain, as a basis for optimization of intensity modulated rotational therapy, final dose calculation and derivation of reference images for patient positioning. Methods: S-CT images were created using a Gaussian mixture regression model on five patients previously treated with radiotherapy. Optimizations were compared using D-max, D-min, D-median and D-mean measures for the target volume and relevant risk structures. Final dose calculations were compared using gamma index with 1%/1 mm and 3%/3 mm acceptance criteria. 3D geometric evaluation was conducted using the DICE similarity coefficient for bony structures. 2D geometric comparison of digitally reconstructed radiographs (DRRs) was performed by manual delineation of relevant structures on the s-CT DRR that were transferred to the CT DRR and compared by visual inspection. Results: Differences for the target volumes in optimization comparisons were small in general, e.g. a mean difference in both D-min and D-max within similar to 0.3%. For the final dose calculation gamma evaluations, 100% of the voxels passed the 1%/1 mm criterion within the PTV. Within the entire external volume between 99.4% and 100% of the voxels passed the 3%/3 mm criterion. In the 3D geometric comparison, the DICE index varied between approximately 0.8-0.9, depending on the position in the skull. In the 2D DRR comparisons, no appreciable visual differences were found. Conclusions: Even though the present work involves a limited number of patients, the results provide a strong indication that optimization and dose calculation based on s-CT data is accurate regarding both geometry and dosimetry.
  •  
7.
  • Jonsson, Joakim H, et al. (författare)
  • Internal fiducial markers and susceptibility effects in MRI : simulation and measurement of spatial accuracy
  • 2012
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier BV. - 0360-3016 .- 1879-355X. ; 82:5, s. 1612-1618
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: It is well-known that magnetic resonance imaging (MRI) is preferable to computed tomography (CT) in radiotherapy target delineation. To benefit from this, there are two options available: transferring the MRI delineated target volume to the planning CT or performing the treatment planning directly on the MRI study. A precondition for excluding the CT study is the possibility to define internal structures visible on both the planning MRI and on the images used to position the patient at treatment. In prostate cancer radiotherapy, internal gold markers are commonly used, and they are visible on CT, MRI, x-ray, and portal images. The depiction of the markers in MRI are, however, dependent on their shape and orientation relative the main magnetic field because of susceptibility effects. In the present work, these effects are investigated and quantified using both simulations and phantom measurements.METHODS AND MATERIALS: Software that simulated the magnetic field distortions around user defined geometries of variable susceptibilities was constructed. These magnetic field perturbation maps were then reconstructed to images that were evaluated. The simulation software was validated through phantom measurements of four commercially available gold markers of different shapes and one in-house gold marker.RESULTS: Both simulations and phantom measurements revealed small position deviations of the imaged marker positions relative the actual marker positions (<1 mm).CONCLUSION: Cylindrical gold markers can be used as internal fiducial markers in MRI.
  •  
8.
  • Jonsson, Joakim H, et al. (författare)
  • Registration accuracy for MR images of the prostate using a subvolume based registration protocol
  • 2011
  • Ingår i: Radiation Oncology. - 1748-717X. ; 6:1, s. 73-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In recent years, there has been a considerable research effort concerning the integration of magnetic resonance imaging (MRI) into the external radiotherapy workflow motivated by the superior soft tissue contrast as compared to computed tomography. Image registration is a necessary step in many applications, e.g. in patient positioning and therapy response assessment with repeated imaging. In this study, we investigate the dependence between the registration accuracy and the size of the registration volume for a subvolume based rigid registration protocol for MR images of the prostate.METHODS: Ten patients were imaged four times each over the course of radiotherapy treatment using a T2 weighted sequence. The images were registered to each other using a mean square distance metric and a step gradient optimizer for registration volumes of different sizes. The precision of the registrations was evaluated using the center of mass distance between the manually defined prostates in the registered images. The optimal size of the registration volume was determined by minimizing the standard deviation of these distances.RESULTS: We found that prostate position was most uncertain in the anterior-posterior (AP) direction using traditional full volume registration. The improvement in standard deviation of the mean center of mass distance between the prostate volumes using a registration volume optimized to the prostate was 3.9 mm (p < 0.001) in the AP direction. The optimum registration volume size was 0 mm margin added to the prostate gland as outlined in the first image series.CONCLUSIONS: Repeated MR imaging of the prostate for therapy set-up or therapy assessment will both require high precision tissue registration. With a subvolume based registration the prostate registration uncertainty can be reduced down to the order of 1 mm (1 SD) compared to several millimeters for registration based on the whole pelvis.
  •  
9.
  • Jonsson, Joakim H, et al. (författare)
  • Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions
  • 2010
  • Ingår i: Radiation Oncology. - 1748-717X. ; 5, s. 62-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Because of superior soft tissue contrast, the use of magnetic resonance imaging (MRI) as a complement to computed tomography (CT) in the target definition procedure for radiotherapy is increasing. To keep the workflow simple and cost effective and to reduce patient dose, it is natural to strive for a treatment planning procedure based entirely on MRI. In the present study, we investigate the dose calculation accuracy for different treatment regions when using bulk density assignments on MRI data and compare it to treatment planning that uses CT data.METHODS: MR and CT data were collected retrospectively for 40 patients with prostate, lung, head and neck, or brain cancers. Comparisons were made between calculations on CT data with and without inhomogeneity corrections and on MRI or CT data with bulk density assignments. The bulk densities were assigned using manual segmentation of tissue, bone, lung, and air cavities.RESULTS: The deviations between calculations on CT data with inhomogeneity correction and on bulk density assigned MR data were small. The maximum difference in the number of monitor units required to reach the prescribed dose was 1.6%. This result also includes effects of possible geometrical distortions.CONCLUSIONS: The dose calculation accuracy at the investigated treatment sites is not significantly compromised when using MRI data when adequate bulk density assignments are made. With respect to treatment planning, MRI can replace CT in all steps of the treatment workflow, reducing the radiation exposure to the patient, removing any systematic registration errors that may occur when combining MR and CT, and decreasing time and cost for the extra CT investigation.
  •  