SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kalinka G.) "

Sökning: WFRF:(Kalinka G.)

  • Resultat 1-20 av 20
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Mason, P, et al. (författare)
  • Octupole signatures in Ba-124,Ba-125
  • 2005
  • Ingår i: Journal of Physics G. - : IOP Publishing. - 0954-3899 .- 1361-6471. ; 31:10, s. S1729-S1733
  • Tidskriftsartikel (refereegranskat)abstract
    • The gamma decay of the nuclei Ba-121,Ba-125 has been investigated with the EUROBALL array, using the reaction Ni-64+Ni-64 at E-beam = 255 and 261 MeV. Six new E1 transitions have been found in the nucleus Ba-125, suggesting a significant role of octupole correlations in the origin of its parity doublets. The J(pi) = 3(-) level of the nucleus Ba-124 has been identified for the first time. Its excitation energy is in very good agreement with a prediction based on a microscopic model including octupole interactions.
  •  
2.
  • Cederwall, Bo, et al. (författare)
  • Evidence for a spin-aligned neutron-proton paired phase from the level structure of 92Pd
  • 2011
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 469:7328, s. 68-71
  • Tidskriftsartikel (refereegranskat)abstract
    • Shell structure and magic numbers in atomic nuclei were generally explained by pioneering work(1) that introduced a strong spin-orbit interaction to the nuclear shell model potential. However, knowledge of nuclear forces and the mechanisms governing the structure of nuclei, in particular far from stability, is still incomplete. In nuclei with equal neutron and proton numbers (N = Z), enhanced correlations arise between neutrons and protons (two distinct types of fermions) that occupy orbitals with the same quantum numbers. Such correlations have been predicted to favour an unusual type of nuclear superfluidity, termed isoscalar neutron-proton pairing(2-6), in addition to normal isovector pairing. Despite many experimental efforts, these predictions have not been confirmed. Here we report the experimental observation of excited states in the N = Z = 46 nucleus Pd-92. Gamma rays emitted following the Ni-58(Ar-36,2n)Pd-92 fusion-evaporation reaction were identified using a combination of state-of-the-art high-resolution c-ray, charged-particle and neutron detector systems. Our results reveal evidence for a spin-aligned, isoscalar neutron-proton coupling scheme, different from the previous prediction(2-6). We suggest that this coupling scheme replaces normal superfluidity (characterized by seniority coupling(7,8)) in the ground and low-lying excited states of the heaviest N = Z nuclei. Such strong, isoscalar neutron-proton correlations would have a considerable impact on the nuclear level structure and possibly influence the dynamics of rapid proton capture in stellar nucleosynthesis.
  •  
3.
  • Zheng, Y., et al. (författare)
  • gamma-ray linear polarization measurements and (g(9/2))(-3) neutron alignment in Ru-91
  • 2013
  • Ingår i: Physical Review C. Nuclear Physics. - : American Physical Society (APS). - 0556-2813 .- 1089-490X. ; 87:4, s. 044328-
  • Tidskriftsartikel (refereegranskat)abstract
    • Linear polarization measurements have been performed for gamma rays in Ru-91 produced with the Ni-58(Ar-36,2p1n gamma)Ru-91 reaction at a beam energy of 111 MeV. The EXOGAM Ge clover array has been used to measure the gamma-gamma coincidences, gamma-ray linear polarization, and gamma-ray angular distributions. The polarization sensitivity of the EXOGAM clover detectors acting as Compton polarimeters has been determined in the energy range 0.3-1.3 MeV. Several transitions have been observed for the first time. Measurements of linear polarization and angular distribution have led to the firm assignments of spin differences and parity of high-spin states in Ru-91. More specifically, calculations using a semiempirical shell model were performed to understand the structures of the first and second (21/2(+)) and (17/2(+)) levels. The results are in good agreement with the experimental data, supporting the interpretation of the nonyrast (21/2(+)) and (17/2(+)) states in terms of the J(max) and J(max) - 2 members of the seniority-three nu(g(9/2))(-3) multiplet.
  •  
4.
  • Ghazi Moradi, Farnaz, et al. (författare)
  • Spectroscopy of the neutron-deficient N=50 nucleus Rh-95
  • 2014
  • Ingår i: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 89:4, s. 044310-
  • Tidskriftsartikel (refereegranskat)abstract
    • The neutron-deficient semimagic (neutron number N = 50) Rh-95 nucleus has been produced at high spins using the projectile-target system Ca-40 + Ni-58 at 125 MeV beam energy. The gamma-decays of levels populated by the 3p fusion evaporation reaction channel were studied using gamma-gamma coincidences, and 20 new gamma-ray transitions involving 15 new positive-and negative-parity states were observed. Spin and parity for many of the excited states were firmly deduced for the first time using the combined directional angular correlation and direction-polarization techniques. The observed structures are discussed within the framework of large-scale shell model calculations. E1 transition strengths were deduced and used together with the results of the shell model calculations to study the contribution of different particle-hole configurations, in particular for analyzing contributions from core-excited configurations.
  •  
5.
  • Hegyesi, G., et al. (författare)
  • Development of an FPGA-based data acquisition module for small animal PET
  • 2004
  • Ingår i: 2004 IEEE Nuclear Science Symposium Conference Record. - 0780387007 ; , s. 2957-2961
  • Konferensbidrag (refereegranskat)abstract
    • We report on the design of a DAQ module for a small animal PET camera developed at our institutes. During the design an important guideline was to develop a system which is built up from strictly identical DAQ modules, and which has no built-in hardware limitation on the maximum number of modules. The developed DAQ module comprises of an LSO scintillator crystal block, a position sensitive PMT, analog signal conditioning circuits, a digitizer, an FPGA for digital signal processing and a communication module through which the collected data is sent to a cluster of computers for post processing and storage. Instead of implementing hardware coincidence detection between the modules we attach a precise time-stamp to each event in our design, and the coincidence is determined by the data collecting computers during the post processing. The digital CFD algorithm implemented in the FPGA gives a time resolution of 2 to 3 ns FWHM for real detector signals.
  •  
6.
  • Hegyesi, G., et al. (författare)
  • Ethernet based distributed data acquisition system for a small animal PET
  • 2006
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 53:4, s. 2112-2117
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the design of a small animal PET scanner being developed at our institutes. The existing setup is the first version of the miniPET machine consisting of four detector modules. Each detector module consists of an 8 x 8 LSO scintillator crystal block, a position sensitive photomultiplier, a digitizer including a digital signal processing board and an Ethernet interface board. There is no hardware coincidence detection implemented in the system and coincidence is determined based on a time stamp attached to every event by a digital CFD algorithm. The algorithm is implemented in the digital signal processing board and generates a time stamp with a coincidence resolution of less than 2 us. The data acquisition system is based on Ethernet network and is highly scalable in size and performance.
  •  
7.
  • Bismarck, A., et al. (författare)
  • Multifunctional epoxy resin for structural supercapacitors
  • 2012
  • Ingår i: 15th European Conference on Composite Materials: Composites at Venice, ECCM 2012; Venice; Italy; 24 June 2012 through 28 June 2012. - 9788888785332
  • Konferensbidrag (refereegranskat)abstract
    • Polymer-based electrolytes based on commercially available epoxy resins were prepared through the addition of a liquid electrolyte, a solution of a lithium salt in an ionic liquid. The polymer monoliths were characterized using impedance spectroscopy, 3-point bending test, scanning electron microscopy (SEM) and nitrogen adsorption (BET). The balance of ionic conductivity and flexural modulus is crucially dependent on the relative proportions of epoxy resin to electrolyte. Also the effect of the liquid electrolyte on curing kinetics and processing was assessed by complex viscosity measurements and differential scanning calorimetry (DSC). Only one out of the three resins investigated exhibited a significant acceleration effect.
  •  
8.
  • Carneiro, Ana P. B., et al. (författare)
  • A framework for mapping the distribution of seabirds by integrating tracking, demography and phenology
  • 2020
  • Ingår i: Journal of Applied Ecology. - : Wiley. - 0021-8901 .- 1365-2664. ; 57:3, s. 514-525
  • Tidskriftsartikel (refereegranskat)abstract
    • The identification of geographic areas where the densities of animals are highest across their annual cycles is a crucial step in conservation planning. In marine environments, however, it can be particularly difficult to map the distribution of species, and the methods used are usually biased towards adults, neglecting the distribution of other life-history stages even though they can represent a substantial proportion of the total population. Here we develop a methodological framework for estimating population-level density distributions of seabirds, integrating tracking data across the main life-history stages (adult breeders and non-breeders, juveniles and immatures). We incorporate demographic information (adult and juvenile/immature survival, breeding frequency and success, age at first breeding) and phenological data (average timing of breeding and migration) to weight distribution maps according to the proportion of the population represented by each life-history stage. We demonstrate the utility of this framework by applying it to 22 species of albatrosses and petrels that are of conservation concern due to interactions with fisheries. Because juveniles, immatures and non-breeding adults account for 47%-81% of all individuals of the populations analysed, ignoring the distributions of birds in these stages leads to biased estimates of overlap with threats, and may misdirect management and conservation efforts. Population-level distribution maps using only adult distributions underestimated exposure to longline fishing effort by 18%-42%, compared with overlap scores based on data from all life-history stages. Synthesis and applications. Our framework synthesizes and improves on previous approaches to estimate seabird densities at sea, is applicable for data-poor situations, and provides a standard and repeatable method that can be easily updated as new tracking and demographic data become available. We provide scripts in the R language and a Shiny app to facilitate future applications of our approach. We recommend that where sufficient tracking data are available, this framework be used to assess overlap of seabirds with at-sea threats such as overharvesting, fisheries bycatch, shipping, offshore industry and pollutants. Based on such an analysis, conservation interventions could be directed towards areas where they have the greatest impact on populations.
  •  
9.
  • Imrek, J., et al. (författare)
  • Internals and evaluation of the miniPET-II detector module
  • 2007
  • Ingår i: 2007 IEEE Nuclear Science Symposium Conference Record. - 1424409233 - 9781424409235 ; , s. 2930-2932
  • Konferensbidrag (refereegranskat)abstract
    • We report on the architecture of the System-on-Module (SoM) developed by our group for miniPET-II, the second version of our small animal PET scanner. The paper describes the hardware and software implementation details of the SoM we realized inside the miniPET-II detector module, the embedded Linux operation system, and the the initial results of bandwidth test measurements on the assembled SoM. Detailed description is given on the interfacing of the updated miniPET IP Core to the SoM, on the efficient data transfer method that implements device-to-device DMA transfer, and on the usage of User Datagram Protocol (UDP/IP) for high speed data transfer.
  •  
10.
  • Kis, S. A., et al. (författare)
  • Comparison of Monte Carlo simulated and measured performance parameters of miniPET scanner
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 571:02-jan, s. 449-452
  • Tidskriftsartikel (refereegranskat)abstract
    • In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to deter-mine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0 GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.
  •  
11.
  • Kis, S. A., et al. (författare)
  • Performance Characteristics of a miniPET Scanner Dedicated to Small Animal Imaging
  • 2005
  • Ingår i: 2005 IEEE Nuclear Science Symposium Conference Record. - 0780392213 - 9780780392212 ; , s. 1645-1648
  • Konferensbidrag (refereegranskat)abstract
    • An easy to scale up modular PET scanner was developed for imaging small animals. Energy resolution, spatial resolution and count rate performance were determined as system parameters. The configuration provided an average energy resolution of 19.6 % and the image resolution ranges was 1.5 to 2.3 mm in radial direction. The sensitivity of the miniPET was 1.08 cps/kBq as determined using a point source. In addition, results of rat brain scan performed with FDG are given to characterize imaging capability of the system. The displayed data document that the miniPET scanner supports good quality brain imaging of small animals.
  •  
12.
  •  
13.
  • Shirshova, N., et al. (författare)
  • Structural supercapacitor electrolytes based on bicontinuous ionic liquid-epoxy resin systems
  • 2013
  • Ingår i: Journal of Materials Chemistry A. - : Royal Society of Chemistry (RSC). - 2050-7488 .- 2050-7496. ; 1:48, s. 15300-15309
  • Tidskriftsartikel (refereegranskat)abstract
    • 'Structural electrolytes' retain the desirable mechanical characteristics of structural (epoxy) resins whilst introducing sufficient ionic conductivity to operate as electrolytes in electrochemical devices. Here, a series of ionic liquid-epoxy resin composites were prepared to identify the optimum system microstructure required to achieve a high level of multifunctionality. The ionic conductivity, mechanical properties, thermal stability and morphology of the cured epoxy based structural electrolytes were studied as a function of phase composition for three fully formulated high performance structural epoxy systems. At only 30 wt% of structural resin and 70 wt% of ionic liquid based electrolyte, stiff monolithic plaques with thicknesses of 2-3 mm were obtained with a room temperature ionic conductivity of 0.8 mS cm-1 and a Young's modulus of 0.2 GPa. This promising performance can be attributed to a long characteristic length scale spinodal microstructure, suggesting routes to further optimisation in the future. © 2013 The Royal Society of Chemistry.
  •  
14.
  • Valastyán, Iván, et al. (författare)
  • LSO based dual slice helical CT and PET demonstrators
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 633, s. S300-S302
  • Tidskriftsartikel (refereegranskat)abstract
    • Two demonstrators, a spiralCT and a miniPET, have been designed and constructed for educational purposes. Computed tomographs (CTs) and positron emission tomographs (PETs) are some of the most commonly used structural and functional imaging devices in medicine, respectively. There is a need for transparent demonstrators where the principles of the different modalities and their functions are presented. The aim of the developments of these systems was to present the major building blocks of CT and PET for undergraduate students. Photon detection in both systems is based on small pixelised scintillation crystals with position sensitive PMT readout. Similar analogue and digital data processing based on FPGA technique is applied for the demonstrators and common image reconstruction and presentation software components are used.
  •  
15.
  • Valastyán, Iván, et al. (författare)
  • Novel time over threshold based readout method for MRI compatible small animal PET detector
  • 2012
  • Ingår i: 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). - : IEEE. - 9781467320306 ; , s. 1295-1299
  • Konferensbidrag (refereegranskat)abstract
    • Combined PET-MRI scanners start a new era in medical imaging. However the development of MRI compatible PET detector module is a challenging task. SiPM sensors are insensitive to magnetic field and constitute a promising solution. A drawback is the high dark current. A readout concept for SiPM based small animal PET detector module is presented in this paper. The results show that the readout of the SiPM is possible using only four ADC channels and the position map is comparable to the ideal solution. The detector modules based on the method are feasible solution for MRI compatible PET scanners.
  •  
16.
  • Imrek, J., et al. (författare)
  • Development of an improved detector module for miniPET-II
  • 2007
  • Ingår i: 2006 IEEE Nuclear Science Symposium Conference Record. - : IEEE. - 1424405610 - 9781424405619 ; , s. 3037-3040
  • Konferensbidrag (refereegranskat)abstract
    • We present a new detector module developed for miniPET-II, the second generation of the miniPET small animal PET scanners. The improved module features new hardware components for better performance: LySO crystal material, increased number of crystal segments, Hamamatsu H9500 PSPMT, Xilinx Virtex-4 FPGA and Gigabit Ethernet. However, the principle of operation is the same: no hardware coincidence detection is implemented, data is acquired in list mode and transfered over an Ethernet network. The resulting new module is more suitable for full ring configurations.
  •  
17.
  • Shirshova, N., et al. (författare)
  • Composition as a Means to Control Morphology and Properties of Epoxy Based Dual-Phase Structural Electrolytes
  • 2014
  • Ingår i: Journal of Physical Chemistry C. - : American Chemical Society (ACS). - 1932-7447 .- 1932-7455. ; 118:49, s. 28377-28387
  • Tidskriftsartikel (refereegranskat)abstract
    • Structural electrolytes were prepared using a fully formulated commercially available high performance epoxy resin (MTM57) and an ionic liquid based electrolyte: lithium bis(trifluoromethylsulfonyl)imide (LiTFSI) dissolved in 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMIM-TFSI). Through a systematic study, the composition of the formulations was found to have a greater effect than the curing temperature on the morphology and properties of the resulting structural electrolytes. The presence of lithium salt is essential to form a structurally homogeneous electrolyte. Bicontinuous morphologies containing continuous (coarse) epoxy networks surrounded by connected spherical epoxy nodules were obtained with different length scales upon varying the lithium salt concentration. Increasing the LiTFSI concentration improved the miscibility of MTM57 with the electrolyte and decreased the characteristic length scale of the resulting bicontinuous microstructure. The properties of the structural electrolytes correlated with the morphology, showing increased Youngs modulus and decreased ionic conductivity with increasing lithium salt concentration. The miscibility of the epoxy system with the electrolyte was also improved by substitution of EMIM-TFSI with an equal weight of an aprotic organic solvent, propylene carbonate (PC); however, the window of PC concentrations which resulted in structural electrolytes with bicontinuous microstructures was very narrow; at PC concentrations above 1 wt %, gel-like polymers with no permanent mesoporosity were obtained.
  •  
18.
  • Simon, A., et al. (författare)
  • High spatial resolution measurement of depth-of-interaction of a PET LSO crystal
  • 2005
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 546:1-2, s. 33-36
  • Tidskriftsartikel (refereegranskat)abstract
    • A new type of experimental technique to investigate the depth- of-interaction (DOI) dependence in small scintillator elements designed for high-resolution animal PET is tested. An Oxford-type nuclear microprobe was used to irradiate a lutetium oxyorthosilicate (LSO) crystal (2 x 2 x 10 mm) with a highly focused, (few micrometers diam.), 2 MeV He+ beam. Pulse height spectra from a PMT attached to one end of the LSO crystal were collected in list mode. By scanning the beam over the crystal high-resolution 2D-images are generated and thus the DOI effect in the scintillator could be investigated. The obtained results of the overall DOI dependence confirm previous findings using gamma-rays. Since the present experimental setup allows obtaining data with several orders of magnitude better spatial resolution than with collimated gamma-beam, the method can be applied for variety of problems where high spatial resolution is required.
  •  
19.
  • Valastyán, Iván, et al. (författare)
  • Experimental scanner setup from miniPET II detector module
  • 2009
  • Ingår i: 2008 IEEE Nuclear Science SYmposium Conference Record. - 9781424427147 ; , s. 3121-3124
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • The PET technique is widely used in human clinical studies and recent developments of image resolution has made it suitable for small animal research. The second generation of our PET scanner consists of 12 detector modules and has a field of view large enough to image mice and rats. Parameters of the incoming data are extracted by Digital Signal Processing in the detector modules and a System-on-Module is used to transmit the data through an Ethernet network for storage and reconstruction. The experimental scanner setup described in this paper was constructed in order to investigate the applicability of the developed detector modules in a full ring small animal PET camera. The preliminary results of the system are also presented.
  •  
20.
  • Wienrich, M., et al. (författare)
  • Impact of ionic liquid on the mechanical performance of matrix polymer for fibre reinforced materials for energy storage
  • 2012
  • Konferensbidrag (refereegranskat)abstract
    • For the concept of using structural materials such as carbon fibre reinforced plastics as energy storage devices, new matrix polymers are required. These polymers must provide ionic conductivity as well as adequate mechanical strength. In the EU-Project StorAGE this requirements are fulfilled by adding ionic liquid to commercial polymers. The mechanical properties of these mixtures materials were characterized by using a 3-point-bending device. In addition, single fibre pull test were performed in order to get information on the interfacial shear strength. Adding of ionic liquid has an impact on the mechanical performance of the materials. A decrease of the flexural strength and modulus of less than 10% of the value of the reference materials took part. The interfacial shear strength decreased to a value of around one third compare to the reference material.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-20 av 20

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy