1.
  • Buse, Giovanna Lurati, et al. (författare)
  • ESAIC focused guideline for the use of cardiac biomarkers in perioperative risk evaluation
  • 2023
  • Ingår i: European Journal of Anaesthesiology. - : LIPPINCOTT WILLIAMS & WILKINS. - 0265-0215 .- 1365-2346. ; 40:12, s. 888-927
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUNDIn recent years, there has been increasing focus on the use of cardiac biomarkers in patients undergoing noncardiac surgery.AIMSThe aim of this focused guideline was to provide updated guidance regarding the pre-, post- and combined pre-and postoperative use of cardiac troponin and B-type natriuretic peptides in adult patients undergoing noncardiac surgery.METHODSThe guidelines were prepared using Grading of Recommendations Assessment Development and Evaluation (GRADE) methodology. This included the definition of critical outcomes, a systematic literature search, appraisal of certainty of evidence, evaluation of biomarker measurement in terms of the balance of desirable and undesirable effects including clinical outcomes, resource use, health inequality, stakeholder acceptance, and implementation. The panel differentiated between three different scopes of applications: cardiac biomarkers as prognostic factors, as tools for risk prediction, and for biomarker-enhanced management strategies.RESULTSIn a modified Delphi process, the task force defined 12 critical outcomes. The systematic literature search resulted in over 25,000 hits, of which 115 full-text articles formed the body of evidence for recommendations. The evidence appraisal indicated heterogeneity in the certainty of evidence across critical outcomes. Further, there was relevant gradient in the certainty of evidence across the three scopes of application. Recommendations were issued and if this was not possible due to limited evidence, clinical practice statements were produced.CONCLUSIONThe ESAIC focused guidelines provide guidance on the perioperative use of cardiac troponin and B-type natriuretic peptides in patients undergoing noncardiac surgery, for three different scopes of application.
  •  
2.
  • Chiang, Cho-Han, et al. (författare)
  • Performance of the European Society of Cardiology 0/1-Hour, 0/2-Hour, and 0/3-Hour Algorithms for Rapid Triage of Acute Myocardial Infarction : An International Collaborative Meta-analysis
  • 2022
  • Ingår i: Annals of Internal Medicine. - 0003-4819. ; 175:1, s. 101-113
  • Forskningsöversikt (refereegranskat)abstract
    • BACKGROUND: The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI).PURPOSE: To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms.DATA SOURCES: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479).STUDY SELECTION: Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI.DATA EXTRACTION: The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality.DATA SYNTHESIS: A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays.LIMITATION: Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies.CONCLUSION: The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI.PRIMARY FUNDING SOURCE: National Taiwan University Hospital.
  •  
3.
  •  
4.
  • Neumann, Johannes Tobias, et al. (författare)
  • Personalized diagnosis in suspected myocardial infarction
  • 2023
  • Ingår i: Clinical Research in Cardiology. - : Springer. - 1861-0684 .- 1861-0692. ; 112, s. 1288-1301
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: In suspected myocardial infarction (MI), guidelines recommend using high-sensitivity cardiac troponin (hscTn)- based approaches. These require fixed assay-specific thresholds and timepoints, without directly integrating clinical information. Using machine-learning techniques including hs-cTn and clinical routine variables, we aimed to build a digital tool to directly estimate the individual probability of MI, allowing for numerous hs-cTn assays.Methods: In 2,575 patients presenting to the emergency department with suspected MI, two ensembles of machine-learning models using single or serial concentrations of six different hs-cTn assays were derived to estimate the individual MI probability ( ARTEMIS model). Discriminative performance of the models was assessed using area under the receiver operating characteristic curve (AUC) and logLoss. Model performance was validated in an external cohort with 1688 patients and tested for global generalizability in 13 international cohorts with 23,411 patients.Results: Eleven routinely available variables including age, sex, cardiovascular risk factors, electrocardiography, and hs-cTn were included in the ARTEMIS models. In the validation and generalization cohorts, excellent discriminative performance was confirmed, superior to hs-cTn only. For the serial hs-cTn measurement model, AUC ranged from 0.92 to 0.98. Good calibration was observed. Using a single hs-cTn measurement, the ARTEMIS model allowed direct rule-out of MI with very high and similar safety but up to tripled efficiency compared to the guideline- recommended strategy.Conclusion We developed and validated diagnostic models to accurately estimate the individual probability of MI, which allow for variable hs-cTn use and flexible timing of resampling. Their digital application may provide rapid, safe and efficient personalized patient care.
  •  