SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Klonoff David C.) "

Search: WFRF:(Klonoff David C.)

  • Result 1-4 of 4
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Tian, Tiffany, et al. (author)
  • Diabetes Technology Meeting 2023
  • 2024
  • In: Journal of Diabetes Science and Technology. - : Diabetes Technology Society. - 1932-2968.
  • Journal article (other academic/artistic)abstract
    • Diabetes Technology Society hosted its annual Diabetes Technology Meeting from November 1 to November 4, 2023. Meeting topics included digital health; metrics of glycemia; the integration of glucose and insulin data into the electronic health record; technologies for insulin pumps, blood glucose monitors, and continuous glucose monitors; diabetes drugs and analytes; skin physiology; regulation of diabetes devices and drugs; and data science, artificial intelligence, and machine learning. A live demonstration of a personalized carbohydrate dispenser for people with diabetes was presented.
  •  
2.
  • Eichenlaub, Manuel, et al. (author)
  • Comparator Data Characteristics and Testing Procedures for the Clinical Performance Evaluation of Continuous Glucose Monitoring Systems
  • 2024
  • In: Diabetes Technology & Therapeutics. - : Mary Ann Liebert. - 1520-9156 .- 1557-8593. ; 26:4, s. 263-275
  • Journal article (peer-reviewed)abstract
    • Comparing the performance of different continuous glucose monitoring (CGM) systems is challenging due to the lack of comprehensive guidelines for clinical study design. In particular, the absence of concise requirements for the distribution of comparator (reference) blood glucose (BG) concentrations and their rate of change (RoC), that are used to evaluate CGM performance, impairs comparability. For this article, several experts in the field of CGM performance testing have collaborated to propose characteristics of the distribution of comparator measurements that should be collected during CGM performance testing. Specifically, it is proposed that at least 7.5% of comparator BG concentrations are <70 mg/dL (3.9 mmol/L) and >300 mg/dL (16.7 mmol/L), respectively and that at least 7.5% of BG-RoC combinations indicate fast BG changes with impending hypo- or hyperglycemia, respectively. These proposed characteristics of the comparator data can facilitate the harmonization of testing conditions across different studies and CGM systems and ensure that the most relevant scenarios representing real-life situations are established during performance testing. In addition, a study protocol and testing procedure for the manipulation of glucose levels is suggested that enables the collection of comparator data with these characteristics. This work is an important step towards establishing a future standard for the performance evaluation of CGM systems.
  •  
3.
  • Freckmann, Guido, et al. (author)
  • Clinical Performance Evaluation of Continuous Glucose Monitoring Systems : A Scoping Review and Recommendations for Reporting
  • 2023
  • In: Journal of Diabetes Science and Technology. - : Sage Publications. - 1932-2968. ; 17:6, s. 1506-1526
  • Research review (peer-reviewed)abstract
    • The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.
  •  
4.
  • Jendle, Johan, 1963-, et al. (author)
  • A narrative commentary about interoperability in medical devices and data used in diabetes therapy from an academic EU/UK/US perspective
  • 2024
  • In: Diabetologia. - : Springer. - 0012-186X .- 1432-0428. ; 67:2, s. 236-245
  • Research review (peer-reviewed)abstract
    • People living with diabetes have many medical devices available to assist with disease management. A critical aspect that must be considered is how systems for continuous glucose monitoring and insulin pumps communicate with each other and how the data generated by these devices can be downloaded, integrated, presented and used. Not only is interoperability associated with practical challenges, but also devices must adhere to all aspects of regulatory and legal frameworks. Key issues around interoperability in terms of data ownership, privacy and the limitations of interoperability include where the responsibility/liability for device and data interoperability lies and the need for standard data-sharing protocols to allow the seamless integration of data from different sources. There is a need for standardised protocols for the open and transparent handling of data and secure integration of data into electronic health records. Here, we discuss the current status of interoperability in medical devices and data used in diabetes therapy, as well as regulatory and legal issues surrounding both device and data interoperability, focusing on Europe (including the UK) and the USA. We also discuss a potential future landscape in which a clear and transparent framework for interoperability and data handling also fulfils the needs of people living with diabetes and healthcare professionals.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-4 of 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close