SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kremer Florence) "

Sökning: WFRF:(Kremer Florence)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Larsson, Matilda, et al. (författare)
  • Ultrasound-Based Radial and Longitudinal Strain Estimation of the Carotid Artery : A Feasibility Study
  • 2011
  • Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010 .- 1525-8955. ; 58:10, s. 2244-2251
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultrasound-based estimation of arterial wall elasticity is commonly used to assess arterial stiffness. However, previous elastography studies have mostly addressed radial strain measurements, and the longitudinal strain has been more or less ignored. This study shows the feasibility of a speckle-tracking-based algorithm for simultaneous estimation of radial and longitudinal strain in the carotid artery in silico. Additionally, these results were preliminarily confirmed in vivo.
  •  
2.
  • Larsson, Matilda, et al. (författare)
  • Ultrasound speckle tracking for radial, longitudinal and circumferential strain estimation of the carotid artery : An in vitro validation via sonomicrometry using clinical and high-frequency ultrasound
  • 2014
  • Ingår i: Ultrasonics. - : Elsevier BV. - 0041-624X .- 1874-9968. ; 56, s. 399-408
  • Tidskriftsartikel (refereegranskat)abstract
    • Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles. Gray-scale ultrasound long-and short-axis images of the phantoms were obtained using a standard clinical ultrasound system, Vivid 7 (GE Healthcare, Horten, Norway) and a high-frequency ultrasound system, Vevo 2100 (FUJIFILM, VisualSonics, Toronto, Canada) with linear-array transducers (12L / MS250). Radial, longitudinal and circumferential strains were estimated using an in-house speckle tracking algorithm and compared with reference strain acquired by sonomicrometry. Overall, the estimated strain corresponded well with the reference strain. The correlation between estimated peak strain in clinical ultrasound images and reference strain was 0.91 (p < 0.001) for radial strain, 0.73 (p < 0.001) for longitudinal strain and 0.90 (p < 0.001) for circumferential strain and for high-frequency ultrasound images 0.95 (p < 0.001) for radial strain, 0.93 (p < 0.001) for longitudinal strain and 0.90 (p < 0.001) for circumferential strain. A significant larger bias and root mean square error was found for circumferential strain estimation on clinical ultrasound images compared to high frequency ultrasound images, but no significant difference in bias and root mean square error was found for radial and longitudinal strain when comparing estimation on clinical and high-frequency ultrasound images. The agreement between sonomicrometry and speckle tracking demonstrates that carotid strain assessment by ultrasound speckle tracking is feasible.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy