SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Krishnan Anantha) "

Sökning: WFRF:(Krishnan Anantha)

  • Resultat 1-12 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Al-Sabri, Mohamed H., et al. (författare)
  • Statins Induce Locomotion and Muscular Phenotypes in Drosophila melanogaster That Are Reminiscent of Human Myopathy : Evidence for the Role of the Chloride Channel Inhibition in the Muscular Phenotypes
  • 2022
  • Ingår i: Cells. - : MDPI. - 2073-4409. ; 11:22
  • Tidskriftsartikel (refereegranskat)abstract
    • The underlying mechanisms for statin-induced myopathy (SIM) are still equivocal. In this study, we employ Drosophila melanogaster to dissect possible underlying mechanisms for SIM. We observe that chronic fluvastatin treatment causes reduced general locomotion activity and climbing ability. In addition, transmission microscopy of dissected skeletal muscles of fluvastatin-treated flies reveals strong myofibrillar damage, including increased sarcomere lengths and Z-line streaming, which are reminiscent of myopathy, along with fragmented mitochondria of larger sizes, most of which are round-like shapes. Furthermore, chronic fluvastatin treatment is associated with impaired lipid metabolism and insulin signalling. Mechanistically, knockdown of the statin-target Hmgcr in the skeletal muscles recapitulates fluvastatin-induced mitochondrial phenotypes and lowered general locomotion activity; however, it was not sufficient to alter sarcomere length or elicit myofibrillar damage compared to controls or fluvastatin treatment. Moreover, we found that fluvastatin treatment was associated with reduced expression of the skeletal muscle chloride channel, C1C-a (Drosophila homolog of CLCN1), while selective knockdown of skeletal muscle C1C-a also recapitulated fluvastatin-induced myofibril damage and increased sarcomere lengths. Surprisingly, exercising fluvastatin-treated flies restored C1C-a expression and normalized sarcomere lengths, suggesting that fluvastatin-induced myofibrillar phenotypes could be linked to lowered C1C-a expression. Taken together, these results may indicate the potential role of C1C-a inhibition in statinassociated muscular phenotypes. This study underlines the importance of Drosophila melanogaster as a powerful model system for elucidating the locomotion and muscular phenotypes, promoting a better understanding of the molecular mechanisms underlying SIM.
  •  
2.
  • Anantha, Krishnan Hariramabadran, et al. (författare)
  • Correlative Microstructure Analysis and In Situ Corrosion Study of AISI 420 Martensitic Stainless Steel for Plastic Molding Applications
  • 2017
  • Ingår i: Journal of the Electrochemical Society. - : Electrochemical Society. - 0013-4651 .- 1945-7111. ; 164:4, s. C85-C93
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, the corrosion behavior of tempered AISI 420 martensitic stainless steel (MSS) was studied by in-situ atomic force microscopy (AFM) in 0.1M NaCl and correlated with the microstructure. Thermocalc simulation, dilatometry, and X-ray diffraction (XRD) were performed to investigate phase transformation which showed the formation of M3C, M7C3, and M23C6 type of carbides and also retained austenite. Optical microscopy, scanning electron microscopy (SEM), and AFM characterization revealed undissolved carbides and tempering carbides in the martensitic matrix. Volta potential mapping measured by scanning Kelvin probe force microscopy (SKPFM) indicated higher electrochemical (practical) nobility of the carbides with respect to the martensitic matrix whereas regions adjacent to carbides showed lower nobilities due to chromium depletion. Open circuit potential and cyclic potentiodynamic polarization measurements showed metastable corrosion activities associated with a weak passive behavior and a risk for localized corrosion along certain carbide boundaries. In-situ AFM measurements revealed selective dissolution of certain carbide interphases and martensitic inter-lath regions indicating higher propensity to localized corrosion.
  •  
3.
  • Anantha, Krishnan Hariramabadran, et al. (författare)
  • Experimental and modelling study of the effect of tempering on the susceptibility to environment-assisted cracking of AISI 420 martensitic stainless steel
  • 2019
  • Ingår i: Corrosion Science. - : PERGAMON-ELSEVIER SCIENCE LTD. - 0010-938X .- 1879-0496. ; 148, s. 83-93
  • Tidskriftsartikel (refereegranskat)abstract
    • The resistance to environment-assisted cracking (EAC) of AISI 420 martensitic stainless steel (MSS) was investigated in 0.3 M NaCl solution (room temperature) at constant loads for 30 days. The steel tempered at 250 degrees C was superior to the 500 degrees C-temper, which showed corrosion pits favouring cracking. The fracture surface showed faceted grains, cleavage, striations, and inter- and transgranular cracks, suggesting a mixed stress corrosion cracking (SCC) and hydrogen embrittlement (HE) mechanism as the cause for EAC. Finite element modelling (FEM) indicated strain/stress localization at the mouth of deep pits and at the wall of shallow pits, displaying the favoured locations for pit-to-crack transition.
  •  
4.
  • Anantha, Krishnan Hariramabadran, et al. (författare)
  • In situ AFM study of localized corrosion processes of tempered AISI 420 martensitic stainless steel : Effect of secondary hardening
  • 2017
  • Ingår i: Journal of the Electrochemical Society. - : Electrochemical Society. - 0013-4651 .- 1945-7111. ; 164:13, s. C810-C818
  • Tidskriftsartikel (refereegranskat)abstract
    • The effect of secondary hardening of tempered AISI 420 martensitic stainless steel on the corrosion behavior in aqueous 0.01 M NaCl has been studied, in-situ, using atomic force microscopy (AFM) to monitor real-time localized corrosion processes. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy, and X-ray diffraction analyses confirmed the presence of undissolved and secondary carbides (Cr23C6, Cr7C3, Cr3C2, Cr3C, Cr2C, and CrC) as well as retained austenite, all finely dispersed in the tempered martensitic matrix. Electrochemical measurements, consisted of monitoring of the open-circuit potential vs. time and cyclic polarization in 0.01 M NaCl solution, were performed to evaluate the passivity and its breakdown, and it was seen that initiation sites for localized corrosion were predominantly peripheral sites of carbides. In-situ AFM measurements revealed that there was a sequence for localized corrosion in which the neighboring matrix next to secondary carbides dissolved first, followed by corrosive attack on regions adjacent to undissolved carbides. Tempering at 500◦C reduced the corrosion resistance and the ability to passivate in comparison to tempering at 250◦C.
  •  
5.
  • Hariramabadran Anantha, Krishnan (författare)
  • An Experimental Study to Understand the Localized Corrosion and Environment-Assisted Cracking Behavior of AISI 420-Martensitic Stainless Steel
  • 2018
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Motivation and aim: Currently steel molds are designed with cooling channels to reduce the solidification time of molten plastic within the mold to improve the productivity. As water is generally used as the cooling medium, corrosion and environment-assisted cracking (EAC) leading towards the dysfunction of mold, can increase the production downtime. This was observed in some cases. Hence the primary aim of this thesis is to study the corrosion and EAC behavior of a martensitic stainless steel (MSS) in Cl containing environment to further the current understanding thereby to optimize the existing alloy/s and to design and develop new steel grades.Methods: The MSS had been austenitised at 1020°C, and subsequently quenched in nitrogen gas at fast (3°C/s), and slow quenching rates (0.6°C/s). Then tempering was done at 250°C, and 500°C, respectively, twice for two hours. Microstructure was predicted and characterized using Thermocalc simulation, dilatometry, light optical microscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, atomic force microscopy (AFM). Localized corrosion behavior was characterized using standard salt spray test, electrochemical experiments, scanning Kelvin probe force microscopy, in-situ AFM. Stress relaxation associated with 250°C, and 500°C tempering was characterized by a new method for both fast (FQ) and slow quenched (SQ) conditions. Based on the %stress relaxation, initial loading levels were altered and the corresponding environment-assisted cracking behavior was investigated at two different loading levels. Results: Samples tempered at 250ºC exhibited higher corrosion resistance than samples tempered at 500ºC in both FQ and SQ conditions. FQ samples exhibited higher corrosion resistance with an ability to passivate than SQ samples when tempered at 250ºC. However, when tempered at 500°C, the corrosion resistance was poor for both FQ and SQ samples. These observed differences clearly indicate the strong influence of microstructure on the corrosion behavior of the material. There are preferential active sites in the microstructure, which dictate the sequence of corrosion events. Secondary Cr-rich carbides formed during 500ºC tempering apparently deteriorate the corrosion resistance in spite of their smaller sizes as compared to undissolved Cr-rich carbides.  Stress relaxation increased with increasing tempering temperature. In the FQ condition, 250°C temper exhibited superior EAC resistance than 500°C temper in both loading scenarios, indicating the dominant role of corrosion resistance in delaying the failure. Whereas in SQ condition, 500°C temper exhibited superior EAC resistance than 250°C temper in both loading scenarios, indicating the dominant role of applied stress in delaying the failure. The pitting susceptibility increased with increasing applied stress on both FQ and SQ conditions. The fractographic features suggest that the mechanism of failure was mixed mode involving both active path dissolution and hydrogen embrittlement, which could have been operative during the failure in varying magnitude in respective scenarios. Conclusions: Based on this research work, it can be concluded that, in order to have a longer service life, both the localized corrosion behavior and the residual stresses are to be considered while recommending tempering temperature to mold makers.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Javadzadeh Kalahroudi, Faezeh, et al. (författare)
  • High-Nitrogen PM Tool Steel : A Comparison Of Microstructure And Mechanical Properties Of As-HIPed And HIPed Followed By Hot Working
  • 2022
  • Ingår i: World PM 2022 Congress Proceedings. - : European Powder Metallurgy Association (EPMA). - 9781899072552
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • High-nitrogen-chromium alloyed powder metallurgy (PM) tool steels offer many attractive features including high strength and corrosion resistance. The PM route offers various advantages such as advanced alloy composition, high homogeneity, and well-defined size distribution of hard phase particles. This study presents microstructure and mechanical properties of a PM Cr-Mo-V-N alloy. The conventional manufacturing route for this alloy is hot isostatic pressing (HIP) followed by hot working. To investigate the possibility of near-net-shape manufacturing, a comprehensive comparison of the performance was made between steels produced by as-HIPed and HIPed followed by hot working. Both steel types were heat treated in the same way to obtain martensitic matrix with limited retained austenite. In the present investigation, microstructure and phase analyses were performed by X-ray diffraction and scanning electron microscopy. Mechanical tests were carried out by hardness measurements and tensile fatigue tests in the very high cycle fatigue regime using ultrasonic fatigue testing. 
  •  
10.
  • Yue, Xiaoqi, et al. (författare)
  • In depth analysis of the passive film on martensitic tool alloy: Effect of tempering temperature
  • 2024
  • Ingår i: Corrosion Science. - : Elsevier. - 0010-938X .- 1879-0496. ; 234
  • Tidskriftsartikel (refereegranskat)abstract
    • Effect of tempering temperature on the composition of the passive film of a martensitic tool alloy was studied by synchrotron-based hard/soft X-ray photoelectron spectroscopy and electrochemical analyses. The contents of Cr and Mo in the passive film are affected by precipitation of tempering carbides. Increase of tempering temperature from 200 to 525°C leads to enhanced formation of Cr/Mo-rich tempering carbides and Cr depletion. Tempering at 525°C results in a Cr content < 11 at% in the underlying metallic layer and formation of a Cr-deficient defective passive film, and thus loss of passivity for the tool alloy in corrosive conditions.
  •  
11.
  • Yue, Xiaoqi, et al. (författare)
  • Synchrotron-based near ambient-pressure X-ray photoelectron spectroscopy and electrochemical studies of passivation behavior of N- and V-containing martensitic stainless steel
  • 2023
  • Ingår i: Corrosion Science. - : Elsevier BV. - 0010-938X .- 1879-0496. ; 214, s. 111018-
  • Tidskriftsartikel (refereegranskat)abstract
    • Passivation behavior of a N-and V-containing martensite stainless steel was studied by synchrotron-based near ambient-pressure X-ray photoelectron spectroscopy, electrochemical analyses, and thermodynamic calculation. The passive film consists of Cr3+, Fe(2, 3)+, and V(2, 3, 4)+ oxides as inner layer, and Cr3+ and Fe3+ hydroxides as outer layer. Austenitization at 1080 oC (rather than 1010 oC) and anodic polarization facilitate transformation of CrN to Cr2O3 leading to further enrichment of Cr3+ oxide in the passive film. Whereas higher Cl- concentration promotes film dissolution leading to higher level of point defects and higher fraction of remaining V oxides in the passive film.
  •  
12.
  • Yue, Xiaoqi, et al. (författare)
  • Unveiling nano-scale chemical inhomogeneity in surface oxide films formed on V- and N-containing martensite stainless steel by synchrotron X-ray photoelectron emission spectroscopy/microscopy and microscopic X-ray absorption spectroscopy
  • 2025
  • Ingår i: Journal of Materials Science & Technology. - : Chinese Society of Metals. - 1005-0302. ; 205, s. 191-203
  • Tidskriftsartikel (refereegranskat)abstract
    • Nano-scale chemical inhomogeneity in surface oxide films formed on a V- and N-containing martensite stainless steel and tempering heating induced changes are investigated by a combination of synchrotron- based hard X-ray Photoelectron emission spectroscopy (HAXPES) and microscopy (HAXPEEM) as well as microscopic X-ray absorption spectroscopy (μ-XAS) techniques. The results reveal the inhomogeneity in the oxide films on the micron-sized Cr2N- and VN-type particles, while the inhomogeneity on the martensite matrix phase exists due to localised formation of nano-sized tempering nitride particles at 600 °C. The oxide film formed on Cr2N-type particles is rich in Cr2O3 compared with that on the martensite matrix and VN-type particles. With the increase of tempering temperature, Cr2O3 formation is faster for the oxidation of Cr in the martensite matrix than the oxidation of Cr nitride-rich particles.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-12 av 12
Typ av publikation
tidskriftsartikel (7)
annan publikation (2)
konferensbidrag (2)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (8)
övrigt vetenskapligt/konstnärligt (4)
Författare/redaktör
Ejnermark, Sebastian (6)
Pan, Jinshan (5)
Örnek, Cem (5)
Medvedeva, Anna (5)
Pan, Jinshan, 1962- (5)
Sjöström, Johnny (4)
visa fler...
Hariramabadran Anant ... (4)
Anantha, Krishnan Ha ... (3)
Yue, Xiaoqi (3)
Larsson, Alfred (2)
Schlueter, Christoph (2)
Scardamaglia, Mattia (2)
Thuvander, Anders (2)
Shavorskiy, Andrey (2)
Chen, Dihao (2)
Gloskovskii, Andrei (2)
Lundgren, Edvin (1)
Grespi, Andrea (1)
Schiöth, Helgi B. (1)
Mwinyi, Jessica (1)
Fredriksson, Robert (1)
Rask-Andersen, Mathi ... (1)
Al-Sabri, Mohamed H. (1)
Alsehli, Ahmed M. (1)
Williams, Michael J. (1)
Boukhatmi, Hadi (1)
Behare, Neha (1)
Berkins, Samuel (1)
Arora, Aadeya (1)
Antoniou, Eirini (1)
Moysiadou, Eleni I. (1)
Anantha-Krishnan, So ... (1)
Cosmen, Patricia D. (1)
Vikner, Johanna (1)
Moulin, Thiago C. (1)
Ammar, Nourhene (1)
Clemensson, Laura E. (1)
Medvedeva, A. (1)
Niu, Yuran (1)
Bergström, Jens, 195 ... (1)
Sjostrom, Johnny (1)
Ejnermark, S. (1)
Sjöström, J. (1)
Golias, Evangelos (1)
Grehk, Mikael (1)
Jeromin, Arno (1)
Keller, Thomas F. (1)
Chantziara, Katerina ... (1)
Javadzadeh Kalahroud ... (1)
Akid, Robert (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (10)
Lunds universitet (4)
Uppsala universitet (1)
Karlstads universitet (1)
Språk
Engelska (12)
Forskningsämne (UKÄ/SCB)
Teknik (9)
Naturvetenskap (2)
Medicin och hälsovetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy