SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kugele Malin) "

Sökning: WFRF:(Kugele Malin)

  • Resultat 1-18 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Al-Hallaq, Hania A., et al. (författare)
  • AAPM task group report 302 : Surface-guided radiotherapy
  • 2022
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405 .- 2473-4209. ; 49:4, s. 82-112
  • Tidskriftsartikel (refereegranskat)abstract
    • The clinical use of surface imaging has increased dramatically, with demonstrated utility for initial patient positioning, real-time motion monitoring, and beam gating in a variety of anatomical sites. The Therapy Physics Subcommittee and the Imaging for Treatment Verification Working Group of the American Association of Physicists in Medicine commissioned Task Group 302 to review the current clinical uses of surface imaging and emerging clinical applications. The specific charge of this task group was to provide technical guidelines for clinical indications of use for general positioning, breast deep-inspiration breath hold treatment, and frameless stereotactic radiosurgery. Additionally, the task group was charged with providing commissioning and on-going quality assurance (QA) requirements for surface-guided radiation therapy (SGRT) as part of a comprehensive QA program including risk assessment. Workflow considerations for other anatomic sites and for computed tomography simulation, including motion management, are also discussed. Finally, developing clinical applications, such as stereotactic body radiotherapy (SBRT) or proton radiotherapy, are presented. The recommendations made in this report, which are summarized at the end of the report, are applicable to all video-based SGRT systems available at the time of writing.
  •  
2.
  • Al-Hallaq, Hania, et al. (författare)
  • The role of surface-guided radiation therapy for improving patient safety
  • 2021
  • Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 1879-0887 .- 0167-8140. ; 163, s. 229-236
  • Tidskriftsartikel (refereegranskat)abstract
    • Emerging data indicates SGRT could improve safety and quality by preventing errors in its capacity as an independent system in the treatment room. The aim of this work is to investigate the utility of SGRT in the context of safety and quality. Three incident learning systems (ILS) were reviewed to categorize and quantify errors that could have been prevented with SGRT: SAFRON (International Atomic Energy Agency), UW-ILS (University of Washington) and AvIC (Skåne University Hospital). A total of 849/9737 events occurred during the pre-treatment review/verification and treatment stages. Of these, 179 (21%) events were predicted to have been preventable with SGRT. The most common preventable events were wrong isocentre (43%) and incorrect accessories (34%), which appeared at comparable rates among SAFRON and UW-ILS. The proportion of events due to wrong accessories was much smaller in the AvIC ILS, which may be attributable to the mandatory use of SGRT in Sweden. Several case scenarios are presented to demonstrate that SGRT operates as a valuable complement to other quality-improvement tools routinely used in radiotherapy. Cases are noted in which SGRT itself caused incidents. These were mostly related to workflow issues and were of low severity. Severity data indicated that events with the potential to be mitigated by SGRT were of higher severity for all categories except wrong accessories. Improved vendor integration of SGRT systems within the overall workflow could further enhance its clinical utility. SGRT is a valuable tool with the potential to increase patient safety and treatment quality in radiotherapy.
  •  
3.
  • Batista, Vania, et al. (författare)
  • Clinical paradigms and challenges in surface guided radiation therapy : Where do we go from here?
  • 2020
  • Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 0167-8140. ; 153, s. 34-42
  • Forskningsöversikt (refereegranskat)abstract
    • Surface guided radiotherapy (SGRT) is becoming a routine tool for patient positioning for specific clinical sites in many clinics. However, it has not yet gained its full potential in terms of widespread adoption. This vision paper first examines some of the difficulties in transitioning to SGRT before exploring the current and future role of SGRT alongside and in concert with other imaging techniques. Finally, future horizons and innovative ideas that may shape and impact the direction of SGRT going forward are reviewed.
  •  
4.
  • Batista, Vania, et al. (författare)
  • Surface guided radiation therapy: : An international survey on current clinical practice
  • 2022
  • Ingår i: Technical Innovations and Patient Support in Radiation Oncology. - : Elsevier BV. - 2405-6324. ; 22, s. 1-8
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Surface Guided Radiation Therapy (SGRT) is being increasingly implemented into clinical practiceacross a number of techniques and irradiation-sites. This technology, which is provided by different vendors, canbe used with most simulation- and delivery-systems. However, limited guidelines and the complexity of clinicalsettings have led to diverse patterns of operation. With the aim to understand current clinical practice a surveywas designed focusing on specifics of the clinical implementation and usage.Materials and methods: A 32-question survey covered: type and number of systems, quality assurance (QA),clinical workflows, and identification of strengths/limitations. Respondents from different professional groupsand countries were invited to participate. The survey was distributed internationally via ESTRO-membership,social media and vendors.Results: Of the 278 institutions responding, 172 had at least one SGRT-system and 136 use SGRT clinically.Implementation and QA were primarily based on the vendors’ recommendations and phantoms. SGRT wasmainly implemented in breast RT (116/136), with strong but diverse representation of other sites. Many (58/135) reported at least partial elimination of skin-marks and a third (43/126) used open-masks. The most commonimaging protocol reported included the combination of radiographic imaging with SGRT. Patient positioning(115/136), motion management (104/136) and DIBH (99/136) were the main applications.Main barriers to broader application were cost, system integration issues and lack of demonstrated clinical value.A lack of guidelines in terms of QA of the system was highlighted.Conclusions: This overview of the SGRT status has the potential to support users, vendors and organisations in thedevelopment of practices, products and guidelines.
  •  
5.
  • Ceberg, Sofie, et al. (författare)
  • Surface guided radiotherapy decreases the uncertainty in breast cancer patient setup
  • 2018
  • Konferensbidrag (refereegranskat)abstract
    • (Sunday, 7/29/2018) 3:00 PM - 6:00 PMRoom: Exhibit HallPurpose: The aim was to investigate if the setup of breast cancer patients could be improved using surface guided radiotherapy, compared to the conventional method using lasers and skin markings.Methods: Forty-seven patients, who received tangential or locoregional adjuvant radiotherapy, were positioned using a surface-based setup (SBS). Thirty-eight patients were positioned using the conventional laser-based setup (LBS). For the patient group positioned using a SBS, correction for posture was performed under guidance of a color map projected onto the patients' skin in real time. The surface tolerance for the color map was 5 mm. For both setup techniques the deviation of the breast position was measured using verification images. In total, 897 images were analysed. The frequency distributions of the deviations were analysed.Results: The result showed a significant improvement in the interfractional variation of the setup deviation for SBS compared to the LBS (pConclusion: Conventional laser-based setup can be replaced by surface-based setup, both for tangential and locoregional breast cancer treatments.
  •  
6.
  • Edvardsson, Anneli, et al. (författare)
  • Comparative treatment planning study for mediastinal Hodgkin’s lymphoma : impact on normal tissue dose using deep inspiration breath hold proton and photon therapy
  • 2019
  • Ingår i: Acta Oncologica. - 0284-186X. ; 58:1, s. 95-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Late effects induced by radiotherapy (RT) are of great concern for mediastinal Hodgkin’s lymphoma (HL) patients and it is therefore important to reduce normal tissue dose. The aim of this study was to investigate the impact on the normal tissue dose and target coverage, using various combinations of intensity modulated proton therapy (IMPT), volumetric modulated arc therapy (VMAT) and 3-dimensional conformal RT (3D-CRT), planned in both deep inspiration breath hold (DIBH) and free breathing (FB). Material and methods: Eighteen patients were enrolled in this study and planned with involved site RT. Two computed tomography images were acquired for each patient, one during DIBH and one during FB. Six treatment plans were created for each patient; 3D-CRT in FB, 3D-CRT in DIBH, VMAT in FB, VMAT in DIBH, IMPT in FB and IMPT in DIBH. Dosimetric impact on the heart, left anterior descending (LAD) coronary artery, lungs, female breasts, target coverage, and also conformity index and integral dose (ID), was compared between the different treatment techniques. Results: The use of DIBH significantly reduced the lung dose for all three treatment techniques, however, no significant difference in the dose to the female breasts was observed. Regarding the heart and LAD doses, large individual variations were observed. For VMAT, the mean heart and LAD doses were significantly reduced using DIBH, but no significant difference was observed for 3D-CRT and IMPT. Both IMPT and VMAT resulted in improved target coverage and more conform dose distributions compared to 3D-CRT. IMPT generally showed the lowest organs at risk (OAR) doses and significantly reduced the ID compared to both 3D-CRT and VMAT. Conclusions: The majority of patients benefited from treatment in DIBH, however, the impact on the normal tissue dose was highly individual and therefore comparative treatment planning is encouraged. The lowest OAR doses were generally observed for IMPT in combination with DIBH.
  •  
7.
  • Jönsson, Mattias, et al. (författare)
  • Technical evaluation of different motion-monitoring systems for respiratory gating in radiation therapy
  • 2013
  • Ingår i: Medical Physics in the Baltic States. - 1822-5721. ; , s. 38-41
  • Konferensbidrag (refereegranskat)abstract
    • The purpose of this work was to evaluate three motion-monitoring systems: Sentinel (TM), Catalyst (TM) (both C-RAD) and Real-time Position Management (RPM (TM)) system (Varian Medical Systems Inc) for respiratory gating in radiotherapy. To measure the systems. latency, an in-house built circuit with a microcontroller operating a piston was used. The trigger pulse was sent from the gating systems to the accelerator within 300 mu s. However, the response time of the accelerator could be over 300 ms
  •  
8.
  •  
9.
  • Kügele, Malin, et al. (författare)
  • Dosimetric effects of intrafractional isocenter variation during deep inspiration breath-hold for breast cancer patients using surface-guided radiotherapy
  • 2018
  • Ingår i: Journal of Applied Clinical Medical Physics. - : Wiley. - 1526-9914. ; 19:1, s. 25-38
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to investigate potential dose reductions to the heart, left anterior descending coronary artery (LAD), and ipsilateral lung for left-sided breast cancer using visually guided deep inspiration breath-hold (DIBH) with the optical surface scanning system Catalyst™, and how these potential dosimetric benefits are affected by intrafractional motion in between breath holds. For both DIBH and free breathing (FB), treatment plans were created for 20 tangential and 20 locoregional left-sided breast cancer patients. During DIBH treatment, beam-on was triggered by a region of interest on the xiphoid process using a 3 mm gating window. Using a novel nonrigid algorithm, the Catalyst™ system allows for simultaneous real-time tracking of the isocenter position, which was used to calculate the intrafractional DIBH isocenter reproducibility. The 50% and 90% cumulative probabilities and maximum values of the intrafractional DIBH isocenter reproducibility were calculated and to obtain the dosimetric effect isocenter shifts corresponding to these values were performed in the treatment planning system. For both tangential and locoregional treatment, the dose to the heart, LAD and ipsilateral lung was significantly reduced for DIBH compared to FB. The intrafractional DIBH isocenter reproducibility was very good for the majority of the treatment sessions, with median values of approximately 1 mm in all three translational directions. However, for a few treatment sessions, intrafractional DIBH isocenter reproducibility of up to 5 mm was observed, which resulted in large dosimetric effects on the target volume and organs at risk. Hence, it is of importance to set tolerance levels on the intrafractional isocenter motion and not only perform DIBH based on the xiphoid process.
  •  
10.
  • Kügele, Malin (författare)
  • Surface guided radiotherapy
  • 2021
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Modern radiotherapy aims to treat the decease while minimizing the radiation dose to the adjacent normal tissue, to minimize acute and late effects of the treatment. The foremost technological approaches have been intensity modulated radiotherapy (IMRT) and intensity modulated proton therapy (IMPT) in combination with image guided radiotherapy (IGRT). IMRT and IMPT is characterized by a more conform dose distribution, often accompanied by steep dose gradients. In turn, accurate patient localization and motion management becomes more important. Several image guidance systems are available for radiotherapy (RT), with 3-dimensional (3D) volumetric images with cone beam computed tomography (CBCT) as a gold standard. In recent years, surface imaging (SI) using an optical surface scanning system has been included in the IGRT toolbox. The SI system CatalystTM (C-rad Positioning AB, Uppsala Sweden) visualize 3D surface images of the patient topography, and direct correlate the patient localization to the initial planned position. SI offers the largest field-of-view in RT, does not contribute to radiation exposure, provides real-time feedback and sub-millimeter spatial resolution. These characteristics are suitable for both patient positioning and motion management during RT.Integration with the linac provides beam control and automatic couch shifts, which imposes rigorous attention to quality assurance (QA) of the SI systems. In order to integrate the beam control, beam latency times (beam-on and beam-off) should be characterized, which required the development PIN diode circuit as a QA tool. Of extra importance was the measurements of the beam-off latency time, since it represents the time the linac continues to irradiate after the beam hold signal was sent from the SI system. The automatic couch shift is calculated by a deformable image registration (DIR) algorithm, unique for the CatalystTM surface scanning system. Positioning accuracy is dependent on the image registration, and hence, a deformable thorax phantom was developed to investigate accuracy of the DIR with anatomical realistic deformations present as a QA tool.Compared to traditional 3-point localization for patient positioning, this thesis has shown that SI improve the positioning for both breast and prostate cancer patients. Also, the SI workflow has shown to be time efficient for positioning of prostate cancer patients. A respiratory motion management technique is deep inspiration breath hold (DIBH), where the patient is instructed to hold his/her breath during the treatment delivery. The aim using DIBH, is to create an anatomical distance between the treatment volume and surrounding organs-at-risk (OARs). Comparative treatment planning studies, within the work of this thesis, showed that DIBH can be an effective method for both left sided breast cancer and Hodgkin’s lymphoma (HL) in order to spare dose to the heart. For HL, the combination of IMPT and DIBH was found to spare dose to OARs, however, due to the spread in target localization individual deviations from this treatment technique were observed. The real-time feedback from the surface image system was used to investigate the reproducibility of the DIBH to ensure correct dose distribution during the treatment delivery. High reproducibility of the isocenter position during DIBH was observed, however, for a few breath holds larger deviations occurred which urges the need to use beam control tolerance for the isocenter. The overall conclusion is that optical imaging systems, developed within the work of this thesis, can be used as an imaging tool for accurate and faster patient setup, intrafractional motion monitoring and reduced dose to OARs during treatment in DIBH.
  •  
11.
  • Kügele, Malin, et al. (författare)
  • Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy
  • 2019
  • Ingår i: Journal of Applied Clinical Medical Physics. - : Wiley. - 1526-9914. ; , s. 61-68
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of the study was to investigate if surface guided radiotherapy (SGRT) can decrease setup deviations for tangential and locoregional breast cancer patients compared to conventional laser-based setup (LBS). Materials and Methods: Both tangential (63 patients) and locoregional (76 patients) breast cancer patients were enrolled in this study. For LBS, the patients were positioned by aligning skin markers to the room lasers. For the surface based setup (SBS), an optical surface scanning system was used for daily setup using both single and three camera systems. To compare the two setup methods, the patient position was evaluated using verification imaging (field images or orthogonal images). Results: For both tangential and locoregional treatments, SBS decreased the setup deviation significantly compared to LBS (P < 0.01). For patients receiving tangential treatment, 95% of the treatment sessions were within the clinical tolerance of ≤ 4 mm in any direction (lateral, longitudinal or vertical) using SBS, compared to 84% for LBS. Corresponding values for patients receiving locoregional treatment were 70% and 54% for SBS and LBS, respectively. No significant difference was observed comparing the setup result using a single camera system or a three camera system. Conclusions: Conventional laser-based setup can with advantage be replaced by surface based setup. Daily SGRT improves patient setup without additional imaging dose to breast cancer patients regardless if a single or three camera system was used.
  •  
12.
  • Lempart, Michael, et al. (författare)
  • Development of a novel radiotherapy motion phantom using a stepper motor driver circuit and evaluation using optical surface scanning
  • 2017
  • Ingår i: Australasian Physical and Engineering Sciences in Medicine. - : Springer Science and Business Media LLC. - 0158-9938 .- 1879-5447. ; 40:3, s. 717-727
  • Tidskriftsartikel (refereegranskat)abstract
    • Abstract: Recent developments in radiotherapy have focused on the management of patient motion during treatment. Studies have shown that significant gains in treatment quality can be made by ‘gating’ certain treatments, simultaneously keeping target coverage, and increasing separation to nearby organs at risk (OAR). Motion phantoms can be used to simulate patient breathing motion and provide the means to perform quality control (QC) and quality assurance (QA) of gating functionality as well as to assess the dosimetric impact of motion on individual patient treatments. The aim of this study was to design and build a motion phantom that accurately reproduces the breathing motion of patients to enable end-to-end gating system quality control of various gating systems as well as patient specific quality assurance. A motion phantom based on a stepper motor driver circuit was designed. The phantom can be programmed with both real patient data from an external gating system and with custom signals. The phantom was programmed and evaluated with patient data and with a square wave signal to be tracked with a Sentinel™ (C-Rad, Uppsala, Sweden) motion monitoring system. Results were compared to the original curves with respect to amplitude and phase. The comparison of patient curve data showed a mean error value of −0.09 mm with a standard deviation of 0.24 mm and a mean absolute error of 0.29 mm. The square wave signals could be reproduced with a mean error value of −0.03 mm, a standard deviation of 0.04 mm and a mean absolute error of 0.13 mm. Breathing curve data acquired from an optical scanning system can be reproduced accurately with the help of the in-house built motion phantom. The phantom can also be programmed to follow user designed curve data. This offers the potential for QC of gating systems and various dosimetric quality control applications. Graphical Abstract: [Figure not available: see fulltext.]
  •  
13.
  • Mannerberg, Annika, et al. (författare)
  • Faster and more accurate patient positioning with surface guided radiotherapy for ultra-hypofractionated prostate cancer patients
  • 2021
  • Ingår i: Technical Innovations and Patient Support in Radiation Oncology. - : Elsevier BV. - 2405-6324. ; 19, s. 41-45
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: The aim of this study was to evaluate if surface guided radiotherapy (SGRT) can decrease patient positioning time for localized prostate cancer patients compared to the conventional 3-point localization setup method. The patient setup accuracy was also compared between the two setup methods. Materials and methods: A total of 40 localized prostate cancer patients were enrolled in this study, where 20 patients were positioned with surface imaging (SI) and 20 patients were positioned with 3-point localization. The setup time was obtained from the system log files of the linear accelerator and compared between the two methods. The patient setup was verified with daily orthogonal kV images which were matched based on the implanted gold fiducial markers. Resulting setup deviations between planned and online positions were compared between SI and 3-point localization. Results: Median setup time was 2:50 min and 3:28 min for SI and 3-point localization, respectively (p < 0.001). The median vector offset was 4.7 mm (range: 0–10.4 mm) for SI and 5.2 mm for 3-point localization (range: 0.41–17.3 mm) (p = 0.01). Median setup deviation in the individual translations for SI and 3-point localization respectively was: 1.1 mm and 1.9 mm in lateral direction (p = 0.02), 1.8 and 1.6 mm in the longitudinal direction (p = 0.41) and 2.2 mm and 2.6 mm in the vertical direction (p = 0.04). Conclusions: Using SGRT for positioning of prostate cancer patients provided a faster and more accurate patient positioning compared to the conventional 3-point localization setup.
  •  
14.
  •  
15.
  •  
16.
  • Mannerberg, Annika, et al. (författare)
  • Surface guided electron FLASH radiotherapy for canine cancer patients
  • 2023
  • Ingår i: Medical Physics. - 0094-2405. ; 50:7, s. 4047-4054
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundDuring recent years FLASH radiotherapy (FLASH-RT) has shown promising results in radiation oncology, with the potential to spare normal tissue while maintaining the antitumor effects. The high speed of the FLASH-RT delivery increases the need for fast and precise motion monitoring to avoid underdosing the target. Surface guided radiotherapy (SGRT) uses surface imaging (SI) to render a 3D surface of the patient. SI provides real-time motion monitoring and has a large scanning field of view, covering off-isocentric positions. However, SI has so far only been used for human patients with conventional setup and treatment.PurposeThe aim of this study was to investigate the performance of SI as a motion management tool during electron FLASH-RT of canine cancer patients.MethodsTo evaluate the SI system's ability to render surfaces of fur, three fur-like blankets in white, grey, and black were used to imitate the surface of canine patients and the camera settings were optimized for each blanket. Phantom measurements using the fur blankets were carried out, simulating respiratory motion and sudden shift. Respiratory motion was simulated using the QUASAR Respiratory Motion Phantom with the fur blankets placed on the phantom platform, which moved 10 mm vertically with a simulated respiratory period of 4 s. Sudden motion was simulated with an in-house developed phantom, consisting of a platform which was moved vertically in a stepwise motion at a chosen frequency. For sudden measurements, 1, 2, 3, 4, 5, 6, 7, and 10 Hz were measured. All measurements were both carried out at the conventional source-to-surface distance (SSD) of 100 cm, and in the locally used FLASH-RT setup at SSD = 70 cm. The capability of the SI system to reproduce the simulated motion and the sampling time were evaluated. As an initial step towards clinical implementation, the feasibility of SI for surface guided FLASH-RT was evaluated for 11 canine cancer patients.ResultsThe SI camera was capable of rendering surfaces for all blankets. The deviation between simulated and measured mean peak-to-peak breathing amplitude was within 0.6 mm for all blankets. The sampling time was generally higher for the black fur than for the white and grey fur, for the measurement of both respiratory and sudden motion. The SI system could measure sudden motion within 62.5 ms and detect motion with a frequency of 10 Hz. The feasibility study of the canine patients showed that the SI system could be an important tool to ensure patient safety. By using this system we could ensure and document that 10 out of 11 canine patients had a total vector offset from the reference setup position ConclusionsWe have shown that SI can be used for surface guided FLASH-RT of canine patients. The SI system is currently not fast enough to interrupt a FLASH-RT beam while irradiating but with the short sampling time sudden motion can be detected. The beam can therefore be held just prior to irradiation, preventing treatment errors such as underdosing the target.
  •  
17.
  •  
18.
  • Pallotta, Stefania, et al. (författare)
  • Validation of a commercial deformable image registration for surface-guided radiotherapy using an ad hoc-developed deformable phantom
  • 2020
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405 .- 2473-4209. ; 47:12, s. 6310-6318
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The use of optical surface systems (OSSs) for patient setup verification in external radiation therapy is increasing. To manage potential deformations in a patient’s anatomy, a novel deformable image registration (DIR) tool has been applied in a commercial OSS. In this study we investigate the accuracy of the DIR as compared to rigid image registration (RR). Methods and Materials: The positioning accuracy of the DIR and RR implemented in the OSS was investigated using an ad hoc-developed anthropomorphic deformable phantom, named Mary. The phantom consists of 33 slices of expanded polystyrene slabs shaped thus to simulate part of a female body. Anatomical details, simulating the ribs and spinal cord, together with 10 inner targets at different depths are included in thorax and abdominal parts. Mary is capable of realistic body movements and deformations, such as head and arm rotations, body torsion and moderate breast/abdomen swelling. The accuracy of DIR and RR was investigated for four internal targets after deliberately deforming the phantom nine times. Breast and abdomen enlargements and torsions around x, y, and z axes were applied. For reference purposes, rigid displacements (where Mary’s anatomy was kept intact) were included. The phantom was positioned on the linac couch under the OSS guidance and for each target and displacement a CBCT was acquired. The accuracy of DIR and RR was assessed evaluating the difference in means of absolute values between CBCT and the OSS registration parameters (lateral, longitudinal, vertical, rot, pitch, and roll), using both a reference surface extracted from CT (CTr) or acquired with the OSS (OSSr). A comparison of the four different combinations, DIR + OSSr, DIR + CTr, RR + OSSr, and RR + CTr, was carried out to evaluate the position accuracy for the various combinations. Finally, the positioning accuracy of the different target positions using only OSSr was investigated for the DIR. A paired sample Wilcoxon signed-rank test (P < 0.05) and a two-tailed Mann–Whitney test (P < 0.05) were carried out. Results: The DIR in combination with OSSr showed significantly (P < 0.05) improved positioning accuracy in the lateral and longitudinal directions and in pitch, compared to RR, when deformations were applied to Mary. The positioning accuracy improved from 1.9 ± 1.5 mm, 1.1 ± 0.8 mm to 1.1 ± 1.2 mm, 0.6 ± 0.5 mm in lateral and longitudinal directions, respectively, and from 0.8 ± 0.6° to 0.4 ± 0.4° in pitch, using DIR compared to RR. Both the DIR and RR showed a similar positioning accuracy when rigid displacements of Mary were applied. For DIR, the OSSr generally showed improved calculation accuracy compared to CTr. Independent of the reference image used, the target position influenced the registration accuracy, and hence, one target could not be evaluated using RR due to its inability to calculate the correct position. Conclusions: Improved positioning accuracy was observed for DIR with respect to RR when deformations of Mary’s anatomy were applied. For both DIR and RR, improved positioning accuracy was observed using OSSr as compared to CTr. The position of the target inside the phantom influenced the positioning accuracy for DIR.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-18 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy