SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Larsson Kaiser Andréas) "

Sökning: WFRF:(Larsson Kaiser Andréas)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Andersson, Olof, et al. (författare)
  • Gradient Hydrogel Matrix for Microarray and Biosensor Applications : An Imaging SPR Study
  • 2009
  • Ingår i: Biomacromolecules. - : American Chemical Society (ACS). - 1525-7797 .- 1526-4602. ; 10:1, s. 142-148
  • Tidskriftsartikel (refereegranskat)abstract
    • A biosensor matrix based on UV-initiated graft copolymerized poly(ethylene glycol) methacrylate and 2-hydroxyethyl methacrylate has been studied using imaging surface plasmon resonance (iSPR). By using a photo mask and a programmable shutter to vary the exposure time laterally, a gradient of matrix spots with physical thicknesses ranging from a few to tens of nanometers was generated. To maximize the dynamic range, imaging SPR was employed in wavelength interrogation mode. By finding the minimum in the reflectance spectra from each pixel of an image, SPR wavelength maps were constructed. The shift in SPR wavelength upon biospecific interaction was then measured both as a function of matrix thickness and composition. The performance of the matrix was evaluated in terms of immobilization of human serum albumin, biomolecular interaction with its antibody, and nonspecific binding of human fibrinogen. In addition, a low molecular weight interaction pair based on a synthetic polypeptide and calmodulin was also studied to explore the size selectivity of the hydrogel matrix. Our results show that the gradient matrix exhibits excellent properties for quick evaluation and screening of optimal hydrogel performance. The mixed hydrogel matrices display very low levels of nonspecific binding. It is also evident that the low molecular weight calmodulin is capable of freely diffusing and interacting throughout the entire hydrogel matrix, whereas the much larger albumin and its corresponding antibody, in particular, are partly/completely hindered from penetrating the interior of the matrix. This size-selectivity is attributed to a significant UV-initiated cross-linking or branching of the matrix during fabrication and/or protein mediated multipoint attachment during immobilization.
  •  
3.
  •  
4.
  • Ekblad, Tobias, 1979-, et al. (författare)
  • Patterned Hydrogels for Controlled Platelet Adhesion from Whole Blood and Plasma
  • 2010
  • Ingår i: Advanced Functional Materials. - : John Wiley & Sons. - 1616-301X .- 1616-3028. ; 20:15, s. 2396-2403
  • Tidskriftsartikel (refereegranskat)abstract
    • This work describes the preparation and properties of hydrogel surface chemistries enabling controlled and well-defined cell adhesion. The hydrogels may be prepared directly on plastic substrates, such as polystyrene slides or dishes, using a quick and experimentally simple photopolymerization process, compatible with photolithographic and microfluidic patterning methods. The intended application for these materials is as substrates for diagnostic cell adhesion assays, particularly for the analysis of human platelet function. The adsorption of fibrinogen and other platelet promoting molecules is shown to be completely inhibited by the hydrogel, provided that the film thickness is sufficient (>5 nm). This allows the hydrogel to be used as a matrix for presenting selected bioactive ligands without risking interference from nonspecifically adsorbed platelet adhesion factors, even in undiluted whole blood and blood plasma. This concept is demonstrated by preparing patterns of proteins on hydrogel surfaces, resulting in highly controlled platelet adhesion. Further insights into the protein immobilization and platelet adhesion processes are provided by studies using imaging surface plasmon resonance. The hydrogel surfaces used in this work appear to provide an ideal platform for cell adhesion studies of platelets, and potentially also for other cell types.
  •  
5.
  • Larsson (Kaiser), Andréas, et al. (författare)
  • A novel biochip technology for detection of explosives - TNT: Synthesis, characterisation and application
  • 2006
  • Ingår i: Sensors and Actuators B: Chemical. - : Elsevier BV. - 0925-4005. ; 113:2, s. 730-748
  • Tidskriftsartikel (refereegranskat)abstract
    • This contribution describes the synthesis, characterisation and evaluation of a novel biochip technology for the detection of the explosive substance 2,4,6-trinitrotoluene (TNT). Two types of thiols are self-assembled to produce the biochip on gold, namely oligo(ethylene glycol) (OEG)-alkyl thiols terminated with a hydroxyl group and a TNT-analogue (2,4-dinitrobenzene), respectively. Three different TNT-analogues are mixed in various proportions with hydroxyl-terminated OEG-thiols to obtain highly selective and sensitive biochips with a low non-specific binding. The produced self-assembled monolayers (SAMs) are thoroughly characterised with null ellipsometry, contact angle goniometry, infrared reflection absorption spectroscopy (IRAS) and X-ray photoelectron spectroscopy (XPS) and they all meet high standards in terms of molecular conformation, packing and orientation. The biochip is designed to function as a platform for a competitive label-free immunoassay and two real-time transducers – surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) – are used to monitor the dissociation of on-line immobilised monoclonal antibodies produced against TNT. The three TNT-analogues are all potential candidates for the development of a functional biochip, though one of them displayed superior properties in terms of shorter recovery/stabilisation time after antibody immobilisation and a better response/loading capacity ratio. This is particularly evident when using low antigen (TNT-analogue) content in the mixed SAM.
  •  
6.
  • Larsson (Kaiser), Andréas, 1976- (författare)
  • Biochip design based on tailored ethylene glycols
  • 2007
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Studies of biomolecular interactions are of interest for several reasons. Beside basic research, the knowledge gained from such studies is also very valuable in for example drug target identification. Medical care is another area where biomolecules may be used as biomarkers to aid physicians in making correct diagnosis. In addition, the highly specific interactions between antibodies and almost any substance opens up the possibilities to design systems for detection of trace amounts of both biological and non-biological substances within environmental restoration, law enforcement, correctional care, customs service and national security. A biochip, which contains a biologically active material, offers a means of monitoring the molecular interactions in the above applications in a sensitive and specific manner. The biochip is a key component of a biosensor, which also includes components for transforming the interaction events into a human-readable signal.This thesis describes the use of poly(ethylene glycol) (PEG) in biochip design. Two different approaches are presented, the first based on ethylene glycol (EG)-containing alkyl thiol self-assembled monolayers (SAMs) on flat gold and the second on photo-induced graft copolymerisation of PEG-containing methacrylate monomers onto various substrates. The former is a two dimensional system where EG-terminated thiols are mixed with similar thiols presenting tail groups that mimic the explosive substance 2,4,6-trinitrotoluene (TNT). In an immunoassay, the detection limit for TNT was determined to fall in the range 1-10 µg/L. In the second approach, a branched three dimensional biosensor matrix (hydrogel) is proposed. The carboxymethylated (CM) dextran matrix, which is commonly used within the biosensing community, is not always ideal for studies of biointeractions, due to the non-specific binding frequently encountered in work with complex biological solutions and various proteins. To employ PEG, which displays a low non-specific binding of such species, is therefore an interesting option worth investigating. The use of a branched graft polymerised PEG matrix in biosensor applications is novel as compared to previous reports which have focused on linear PEG chains. The latter approach provides, at maximum, one functional group, per surface anchoring point, for immobilisation of sensor elements. Thus, it has the inherited disadvantage that it limits the number of available immobilisation sites. The present PEG matrix contains a large number of functional groups, for immobilisation of sensor elements, per grafting site and offers the potential of improved response upon binding to the analyte as demonstrated in a series of successful sensor experiments.Furthermore, the nature of the process enables easy preparation of matrix patterns and gradients. In a PEG matrix gradient, protein permeability is studied and the capabilities of immobilising proteins are demonstrated. By combining the patterning technique with different monomers in a two-step process, an inert platform, lacking chemical attachment sites, is provided with arrays of spots (with immobilisation capabilities), which are conveniently addressed via microdispensing and used for biosensor purposes. The EG-terminated thiols present another means of generating such inert platforms, a route which is also investigated. To further explore the sensor quality of these spots, the concepts of patterning and gradient formation are combined and studied.
  •  
7.
  • Larsson (Kaiser), Andréas, et al. (författare)
  • Photografted poly(ethylene glycol) matrix for affinity interaction studies
  • 2007
  • Ingår i: Biomacromolecules. - : American Chemical Society (ACS). - 1525-7797 .- 1526-4602. ; 8:1, s. 287-295
  • Tidskriftsartikel (refereegranskat)abstract
    • A poly(ethylene glycol) (PEG)-based matrix for studies of affinity interactions is developed and demonstrated. The PEG matrix, less than 0.1 μm thick, is graft copolymerized onto a cycloolefin polymer from a mixture of PEG methacrylates using a free radical reaction initiated by UV light at 254 nm. The grafting process is monitored in real time, and characteristics such as thickness, homogeneity, relative composition, photostability, and performance in terms of protein resistance in complex biofluids and sensor qualities are investigated with null ellipsometry, infrared spectroscopy, and surface plasmon resonance. The matrix is subsequently modified to contain carboxyl groups, thereby making it possible to immobilize ligands in a controlled and functional manner. Human serum albumin and fibrinogen are immobilized and successfully detected by antibody recognition using surface plasmon resonance. The results are encouraging and suggest that the PEG matrix is suitable for biochip and biosensor applications in demanding biofluids.
  •  
8.
  • Larsson (Kaiser), Andréas, et al. (författare)
  • Poly(ethylene glycol) gradient for biochip development
  • 2007
  • Ingår i: Langmuir. - : American Chemical Society (ACS). - 0743-7463 .- 1520-5827. ; 23:22, s. 11319-11325
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel method of producing a poly(ethylene glycol) (PEG)-based gradient matrix that varies gradually in thickness from 0 to 500 Å over a distance of 5−20 mm is presented. The gradient matrix is graft copolymerized from a mixture of PEG methacrylates onto organic thin films providing free radical polymerization sites initiated by UV irradiation at 254 nm. The films used as grafting platforms consist of either a spin-coated cycloolefin polymer or a self-assembled monolayer on planar gold. The thickness/irradiation gradient is realized by means of a moving shutter that slowly uncovers the modified gold substrate. The structural and functional characteristics of the gradient matrix are investigated with respect to thickness profile, degree of carboxylation, and subsequent immobilization of two model proteins of different sizes and shapes. These characteristics are studied with ellipsometry and infrared reflection−absorption microscopy using a grazing angle objective. It is revealed that the relatively small carboxylation agent used offers homogeneous activation throughout the gradient, even in the thick areas, whereas the diffusion/interpenetration and subsequent immobilization of large proteins is partially hindered. This is crucial information in biosensor design that can be easily obtained from a gradient experiment on a single sample. Moreover, the partially hindered protein interpenetration, the marginal swelling upon hydration, and the unspecific nature of the graft polymerization suggest a matrix growth mechanism that favors the formation of a bushlike polymer structure with a certain degree of cross linking.
  •  
9.
  • Larsson (Kaiser), Andréas, et al. (författare)
  • UV-patterned poly(ethylene glycol) matrix for microarray applications
  • 2007
  • Ingår i: Biomacromolecules. - : American Chemical Society (ACS). - 1525-7797 .- 1526-4602. ; 8:11, s. 3511-3518
  • Tidskriftsartikel (refereegranskat)abstract
    • A versatile method to fabricate polymeric matrixes for microarray applications is demonstrated. Several different design strategies are presented where a variety of organic films, such as plastic polymers and self-assembled monolayers (SAMs) on planar silica and gold substrates, act as supports for the graft polymerization procedure. An ensemble of poly(ethylene glycol) methacrylate monomers are combined to obtain a matrix with desired properties:  low nonspecific binding and easily accessible groups for postimmobilization of ligands. The free radical graft polymerization process occurs under irradiation with UV light in the 254−266 nm range, which offers the possibility to introduce patterns by means of a photomask. The arrays are created on inert and homogeneous coatings prepared either by graft polymerization of a methoxy-terminated PEG−methacrylate or self-assembly of a methoxy-terminated oligo(ethylene glycol) thiol. Carboxylic acid groups, introduced in the array spots either during graft polymerization or upon wet chemical conversion of hydroxyls, grant the capability to immobilize proteins and other molecules via free amine groups. Immobilization of fluorescent species as well as biotin followed by exposure to a fluorescently labeled antibody directed toward biotin display both excellent integrity of the spots and low nonspecific binding to the surrounding framework. Beside patterns of uniform height and size, an array of spots with varying thickness (a sort of gradient) is demonstrated. Such gradient samples enable us to address critical issues regarding the mechanism(s) behind spatially resolved free radical polymerization of methacrylates. It also offers a convenient route to optimize the matrix properties with respect to thickness, loading capacity, protein diffusion/penetration, and nonspecific binding.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy