SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Leone Michele) "

Sökning: WFRF:(Leone Michele)

  • Resultat 1-13 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Asciutto, Giuseppe, et al. (författare)
  • Intravascular ultrasound in the detection of bridging stent graft instability during fenestrated and branched endovascular aneurysm repair procedures : a multicentre study on 274 target vessels
  • 2024
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier. - 1078-5884 .- 1532-2165. ; 67:1, s. 99-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The use of intravascular ultrasound (IVUS) reduces contrast medium use and radiation exposure during conventional endovascular aneurysm repair (EVAR). The aim of this study was to evaluate the safety and efficacy of IVUS in detecting bridging stent graft (bSG) instability during fenestrated and branched EVAR (F/B-EVAR).Methods: This was a prospective observational multicentre study. The following outcomes were evaluated: (1) technical success of the IVUS in each bSG, (2) IVUS findings compared with intra-operative angiography, (3) incidence of post-operative computed tomography angiography (CTA) findings not detected with IVUS, and (4) absence of IVUS related adverse events. Target visceral vessel (TVV) instability was defined as any branch or fenestration issues requiring an additional manoeuvre or re-intervention. Any IVUS assessment that detected stenosis, kinking, or any geometric TVV issue was considered to be branch instability. All procedures were performed in ad hoc hybrid rooms.Results: Eighty patients (69% males; median age 72 years; interquartile range 59, 77 years) from four aortic centres treated with F/B-EVAR between January 2019 and September 2021 were included: 70 BEVAR (21 off the shelf; 49 custom made), eight FEVAR (custom made), and two F/B-EVAR (custom made), for a total of 300 potential TVVs. Two TVVs (0.7%) were left unstented and excluded from the analysis. The TVVs could not be accessed with the IVUS catheter in seven cases (2.3%). Furthermore, 17 (5.7%) TVVs could not be examined due to a malfunction of the IVUS catheter. The technical success of the IVUS assessment was 91.9% (274/298), with no IVUS related adverse events. Seven TVVs (2.5%) showed signs of bSG instability by means of IVUS, leading to immediate revisions. The first post-operative CTA at least 30 days after the index procedure was available in 268 of the 274 TVVs originally assessed by IVUS. In seven of the 268 TVVs (2.6%) a re-intervention became necessary due to bSG instability.Conclusion: This study suggests that IVUS is a safe and potentially valuable adjunctive imaging technology for intra-operative detection of TVV instability. Further long term investigations on larger cohorts are required to validate these promising results and to compare IVUS with alternative technologies in terms of efficiency, radiation exposure, procedure time, and costs.
  •  
2.
  • Cancelloni, Virginia, et al. (författare)
  • Reperfusion therapies in patients with acute ischaemic stroke and atrial fibrillation: data on safety and effectiveness from a multi-centre cohort study
  • 2024
  • Ingår i: NEUROLOGICAL SCIENCES. - 1590-1874 .- 1590-3478.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Intravenous thrombolysis (IVT) and/or endovascular therapy (EVT) are currently considered best practices in acute stroke patients. Data regarding the efficacy and safety of reperfusion therapies in patients with atrial fibrillation (AF) are conflicting as regards haemorrhagic transformation, mortality, and functional outcome. This study sought to investigate for any differences, in terms of safety and effectiveness, between AF patients with acute ischaemic stroke (AIS) treated and untreated with reperfusion therapies.Methods Data from two multicenter cohort studies (RAF and RAF-NOACs) on consecutive patients with AF and AIS were analyzed to compare patients treated and not treated with reperfusion therapies (IVT and/or EVT). Multivariable logistic regression analysis was performed to identify independent predictors for outcome events: 90-day good functional outcome and mortality. A propensity score matching (PSM) analysis compared treated and untreated patients.Results Overall, 441 (25.4%) were included in the reperfusion-treated group and 1,295 (74.6%) in the untreated group. The multivariable model suggested that reperfusion therapies were significantly associated with good functional outcome. Rates of mortality and disability were higher in patients not treated, especially in the case of higher NIHSS scores. In the PSM comparison, 173/250 patients (69.2%) who had received reperfusion therapies had good functional outcome at 90 days, compared to 146/250 (58.4%) untreated patients (p = 0.009, OR: 1.60, 95% CI:1.11-2.31).Conclusions Patients with AF and AIS treated with reperfusion therapies had a significantly higher rate of good functional outcome and lower rates of mortality compared to those patients with AF and AIS who had undergone conservative treatment.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate loading of 2 (all-on-2) flapless-placed mandibular implants supporting cross-arch fixed prostheses: interim data from a 1-year follow-up prospective single cohort study.
  • 2012
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 5:1, s. 49-58
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the clinical outcome of 2 implants placed flapless in fully edentulous mandibles and immediately restored with a metal-resin screw-retained cross-arch prosthesis 1 year after loading.Eighty consecutive patients were recruited. To be immediately loaded, implants had to be inserted with a minimum torque of 80 Ncm. Outcome measures, evaluated by two independent assessors, were prosthesis and implant failures, complications, marginal bone level changes, implant stability quotient (ISQ) values and patient satisfaction.Flaps were raised in 7 patients. Twelve implants in 7 patients did not reach the planned insertion torque. Four implants in 3 patients were immediately replaced by larger diameter implants and achieved the desired torque, whereas the remaining implants were immediately loaded anyway. Two implants failed early in 2 patients, but were successfully replaced and their prostheses remade. One month after loading, 72 (90%) patients declared to be completely satisfied with the therapy, 7 (9%) partially satisfied and 1 (1%) unsatisfied. One year after loading, all prostheses were in function, though one patient did not attend the 1-year control. Eight (10%) complications occurred, all successfully treated. After 1 year, the mean marginal bone loss was 0.3 mm and mean ISQ values decreased from 75.4 to 72.4.These short-term results at 1 year after loading suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only 2 dental implants. Longer follow-ups (around 10 years) are needed to know the prognosis of this treatment modality.
  •  
7.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate loading of 2(all-on-2) versus 4 (all-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: 1-year results from a pilot randomised controlled trial.
  • 2013
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 6:2, s. 121-31
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the outcome of 2 versus 4 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.Sixty patients from two different centres were randomised: 30 to the allon- 2 group and 30 to the all-on-4 group according to a parallel group design. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, complications, and marginal bone level changes.Flaps were raised in 18 patients. A total of 2 implants in 2 patients did not reach the planned insertion torque and were immediately replaced by larger diameter ones. One year after loading, no drop-out or implant failure occurred. Eight biomechanical complications occurred in the all-on-2 group versus 8 complications in the all-on-4 group. There were no statistically significant differences for complications between groups. There were no statistically significant differences for marginal peri-implant bone levels between the two groups (estimate of the difference = -0.16; 95%CI -0.40 to 0.08; P (ANCOVA) = 0.074), with both groups losing a statistically significant amount of marginal bone (0.74 mm for all-on-2 implants and 0.58 mm for all-on-4 implants). There were statistically significant differences between the two centres, with more bone being lost for the Bologna centre (0.26 mm versus 1.07 mm).These preliminary results, up to 1 year after loading, suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only 2 dental implants. Longer followups (approximately 10 years) are needed to properly evaluate this therapeutic option.
  •  
8.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate loading of 2 (all-on-2) versus 4 (all-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: preliminary results from a pilot randomised controlled trial.
  • 2011
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 4:3, s. 205-17
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the clinical outcome of 2 implants versus 4 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.Sixty patients from two different centres were randomised: 30 to the allon- 2 group and 30 to the all-on-4 group. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, and biological and biomechanical complications.Flaps were raised in 18 patients. Two implants in 2 patients did not reach the planned insertion torque and were immediately replaced by larger diameter ones. Four months after loading, no drop-out or implant failure occurred. One biomechanical complication occurred in the all-on-2 group versus 4 in the all-on-4 group. There were no statistically significant differences between groups for complications. There were no differences between centres.These very preliminary results, just 4 months after loading, suggest that immediately loaded mandibular cross-arch fixed dental prostheses can be supported by only 2 dental implants. Longer follow-ups (around 10 years) are needed to understand whether cross-arch mandibular prostheses can be successfully supported by only 2 dental implants.
  •  
9.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate occlusal versus non-occlusal loading of single zirconia implants. A multicentre pragmatic randomised clinical trial.
  • 2010
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 3:2, s. 111-20
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate whether immediate non-occlusal loading of single zirconia implants could reduce early failures when compared to immediate occlusal loading. MATERIALS AND METHODS: Forty partially edentulous patients who received one single zirconia implant (Z-Systems) at least 10 mm long and 3.25 mm wide inserted with a torque of at least 35 Ncm were randomised to immediate occlusal or non-occlusal loading groups. All patients received provisional acrylic crowns the same day of implant placement. Provisional crowns were replaced after 4 to 5 months by definitive full ceramic crowns. Outcome measures were implant success, any complications and peri-implant marginal bone levels. RESULTS: One year after loading, no patients had dropped out. Five implants (12.5%) failed early: three occlusally loaded and two non-occlusally loaded. Three complications occurred, all after delivery of the definitive crowns: one crown fractured (occlusal loading), one had to be remade after debridement because of hyperplastic tissues (occlusal loading), and one crown decemented (nonocclusal loading). These differences were not statistically significant. Both groups gradually lost periimplant bone in a highly statistically significant way. One year after loading, patients subjected to non-occlusal loading lost an average of 0.7 mm of peri-implant bone versus 0.9 mm in the occlusal group. This difference in bone loss between groups was not statistically significant. There was an association between immediate post-extractive implants and implant failures (P=0.01). Four of the 10 immediate post-extractive implants (40%) failed versus one out of 30 delayed implants (3%). CONCLUSIONS: The results of this study do not provide a conclusive answer to whether immediate non-occlusal loading may decrease implant failures. Immediately loaded zirconia implants placed in post-extractive sites had high failure rates.
  •  
10.
  • Esposito, Marco, 1965, et al. (författare)
  • Effectiveness of prophylactic antibiotics at placement of dental implants: a pragmatic multicentre placebo-controlled randomised clinical trial
  • 2010
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 3:2, s. 135-143
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate the efficacy of prophylactic antibiotics for dental implant placement. MATERIALS AND METHODS: Thirteen dentists working in private practices agreed to participate in this trial, each centre providing 50 patients. One hour prior to implant placement, patients were randomised to take orally 2 g amoxicillin or identical placebo tablets. Patients needing bone augmentation at implant placement were not included. Outcome measures were prosthesis and implant failures, adverse events and post-operative complications. Patients were seen 1 week, 2 weeks and 4 months post-operatively. RESULTS: Two centres did not deliver any data, two centres did not manage to include the agreed quota of patients and three patients had to be excluded. Two-hundred and fifty-two patients were evaluated in the antibiotic group and 254 in the placebo group, and none dropped out at 4 months. Four prostheses and seven implants (in five patients) failed in the antibiotics group versus 10 prostheses and 13 implants (in 12 patients) in the placebo group. Eleven complications were reported in the antibiotic group versus 13 (in 12 patients) in the placebo group. No side effects were reported. There were no statistically significant differences for prosthesis failures, implant losses and complications. Patients receiving immediate post-extractive implants had an increased failure risk compared with patients receiving delayed implants (9% versus 2%). CONCLUSIONS: No statistically significant differences were observed, although trends clearly favoured the antibiotic group. Immediate post-extractive implants were more likely to fail.
  •  
11.
  • Longo, Michele, et al. (författare)
  • Altered H3K4me3 profile at the TFAM promoter causes mitochondrial alterations in preadipocytes from first-degree relatives of type 2 diabetics
  • 2023
  • Ingår i: CLINICAL EPIGENETICS. - 1868-7075 .- 1868-7083. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background First-degree relatives of type 2 diabetics (FDR) exhibit a high risk of developing type 2 diabetes (T2D) and feature subcutaneous adipocyte hypertrophy, independent of obesity. In FDR, adipose cell abnormalities contribute to early insulin-resistance and are determined by adipocyte precursor cells (APCs) early senescence and impaired recruitment into the adipogenic pathway. Epigenetic mechanisms signal adipocyte differentiation, leading us to hypothesize that abnormal epigenetic modifications cause adipocyte dysfunction and enhance T2D risk. To test this hypothesis, we examined the genome-wide histone profile in APCs from the subcutaneous adipose tissue of healthy FDR.Results Sequencing-data analysis revealed 2644 regions differentially enriched in lysine 4 tri-methylated H3-histone (H3K4me3) in FDR compared to controls (CTRL) with significant enrichment in mitochondrial-related genes. These included TFAM, which regulates mitochondrial DNA (mtDNA) content and stability. In FDR APCs, a significant reduction in H3K4me3 abundance at the TFAM promoter was accompanied by a reduction in TFAM mRNA and protein levels. FDR APCs also exhibited reduced mtDNA content and mitochondrial-genome transcription. In parallel, FDR APCs exhibited impaired differentiation and TFAM induction during adipogenesis. In CTRL APCs, TFAM-siRNA reduced mtDNA content, mitochondrial transcription and adipocyte differentiation in parallel with upregulation of the CDKN1A and ZMAT3 senescence genes. Furthermore, TFAM-siRNA significantly expanded hydrogen peroxide (H2O2)-induced senescence, while H2O2 did not affect TFAM expression.Conclusions Histone modifications regulate APCs ability to differentiate in mature cells, at least in part by modulating TFAM expression and affecting mitochondrial function. Reduced H3K4me3 enrichment at the TFAM promoter renders human APCs senescent and dysfunctional, increasing T2D risk.
  •  
12.
  • Schreiber, Stefan, et al. (författare)
  • Defining Comprehensive Disease Control for use as a Treatment Target for Ulcerative Colitis in Clinical Practice : International Delphi Consensus Recommendations
  • 2024
  • Ingår i: Journal of Crohn's & Colitis. - : Oxford University Press. - 1873-9946 .- 1876-4479. ; 18:1, s. 91-105
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND AIMS: Treatment of ulcerative colitis (UC) requires a patient-centric, definition of comprehensive disease control that considers improvements in aspects not typically captured by classical landmark trial endpoints. In an international initiative we reviewed aspects of UC that affect patients and/or indicate mucosal inflammation, to achieve consensus on which aspects to combine in a definition of comprehensive disease control, using a modified Delphi process.METHODS: The Delphi panel comprised 12 gastroenterologists and one patient advocate. Two gastroenterologists were elected as chairs and did not vote. To inform statements, we asked 18 patients and the panel members about their experiences of remission and reviewed published literature. Panel members voted on statements anonymously in three rounds, with a live discussion before round 3. Consensus was met if ≥ 67% of the panel agreed. Statements without consensus in rounds 1 and 2 were revised or discarded after round 3.RESULTS: The panel agreed to measure individual patient benefit using a definition of comprehensive disease control that combines aspects currently measured in trials (rectal bleeding, stool frequency, disease-related quality of life, endoscopy, histological inflammatory activity, inflammatory biomarkers, and corticosteroid use), with additional patient-reported symptoms (bowel urgency, abdominal pain, extraintestinal manifestations, fatigue, and sleep disturbance). The panel agreed on scoring systems and thresholds for many aspects.CONCLUSIONS: Using a robust methodology, we defined comprehensive disease control in UC. Next, we will combine the measurement and scoring of these aspects into a multi-component tool and adopt comprehensive disease control as a treatment target in clinical practice and trials.
  •  
13.
  • Sodergren, Erica, et al. (författare)
  • The genome of the sea urchin Strongylocentrotus purpuratus.
  • 2006
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 1095-9203 .- 0036-8075. ; 314:5801, s. 941-52
  • Tidskriftsartikel (refereegranskat)abstract
    • We report the sequence and analysis of the 814-megabase genome of the sea urchin Strongylocentrotus purpuratus, a model for developmental and systems biology. The sequencing strategy combined whole-genome shotgun and bacterial artificial chromosome (BAC) sequences. This use of BAC clones, aided by a pooling strategy, overcame difficulties associated with high heterozygosity of the genome. The genome encodes about 23,300 genes, including many previously thought to be vertebrate innovations or known only outside the deuterostomes. This echinoderm genome provides an evolutionary outgroup for the chordates and yields insights into the evolution of deuterostomes.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-13 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy