SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Linder D.R.) "

Sökning: WFRF:(Linder D.R.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Carlsson, Ella, et al. (författare)
  • Mass composition of the escaping plasma at Mars
  • 2006
  • Ingår i: Icarus. - : Elsevier BV. - 0019-1035 .- 1090-2643. ; 182:2, s. 320-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Data from the Ion Mass Analyzer (IMA) sensor of the ASPERA-3 instrument suite on Mars Express have been analyzed to determine the mass composition of the escaping ion species at Mars. We have examined 77 different ion-beam events and we present the results in terms of flux ratios between the following ion species: CO2+/O+ and O-2(+)/O+. The following ratios averaged over all events and energies were identified: CO2+/O+ = 0.2 and O-2(+)/O+ = 0.9. The values measured are significantly higher, by a factor of 10 for O-2(+)/O+, than a contemporary modeled ratio for the maximum fluxes which the martian ionosphere can supply. The most abundant ion species was found to be O+, followed by O-2(+) and CO2+. We estimate the loss of CO2+ to be 4.0 x 10(24) s(-1) (0.29 kg s(-1)) by using the previous measurements of Phobos-2 in our calculations. The dependence of the ion ratios in relation to their energy ranges we studied, 0.3-3.0 keV, indicated that no clear correlation was found.
  •  
2.
  • Lewis, G. R., et al. (författare)
  • The calibration of the Cassini-Huygens CAPS Electron Spectrometer
  • 2010
  • Ingår i: Planetary and Space Science. - : Elsevier BV. - 0032-0633 .- 1873-5088. ; 58:3, s. 427-436
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the two-stage method used to calibrate the electron spectrometer (ELS), part of the plasma spectrometer (CAPS) on board the Cassini spacecraft currently in orbit around Saturn. The CAPS-ELS is a top-hat electrostatic analyser designed to measure electron fluxes between 0 5 eV and 26 keV The on-ground calibration method described here includes the production of photoelectrons, which are energised and passed into the CAPS-ELS in a purpose designed calibration facility. Knowledge of the intensity of these incident electrons and the subsequent instrument output provides an on-ground calibrated geometric factor. Comparative studies of physical quantities such as plasma density and electron differential flux calculated using on-ground calibration factor with the quantities deduced from the wave experiment and high energy electron detector provide in-flight calibration. The results of this are presented together with a comparison of the experimentally calibrated values with simulated calibration values.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy