SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lindgren PG) "

Sökning: WFRF:(Lindgren PG)

  • Resultat 1-37 av 37
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Abdsaleh, Shahin, 1957- (författare)
  • Core Biopsy of Breast and Axillary Lesions : Technical and Clinical Aspects
  • 2006
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The aims of this work were to image and analyze the needle behavior at automated core biopsy, to investigate the clinical utility of an alternative core biopsy technique using a semiautomated gun in breast and axillary lesions, and also to compare core biopsy with surgical specimens in malignant breast lesions regarding histologic features and hormone receptor expression.In two experimental studies, using butter and silicon phantoms, respectively, the needle pass was imaged and its dynamic behavior studied. It was shown that the needle took a curved course in phantoms. It deviated to the same side as where the tip lay, and the degree of the curvature increased with increasing hardness of the phantoms. Our experimental methods can be applied for imaging of needle behavior and thereby improvement of needle configuration.In two clinical studies, a semiautomated gun was used for large needle core biopsy of breast and axillary lesions in two series of 145 and 21 patients, respectively. The sensitivity of the method for diagnosis of malignancy was 87% (108/124), and in 37% (31/83) of cases the full length of the needle notch was filled with specimen. No injury to the neurovascular structures of the axillary area was observed. It was concluded that the semiautomated gun can be used as an alternative to the automated gun when the size and location of the lesion render use of the automatic device uncertain or dangerous, e.g., in small breast lesions or lesions located in the axilla.In a series of 129 cases of breast cancer, comparison of core biopsy and surgical specimens showed that core biopsy provided enough information on the histologic type and grade of the lesions. Also, there was moderate to high concordance between the two methods for assessment of progesterone receptors and estrogen receptors (Spearman`s kappa 0.67 and 0.89, respectively).
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Alcorn, J, et al. (författare)
  • Basic instrumentation for Hall A at Jefferson Lab
  • 2004
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 522:3, s. 294-346
  • Tidskriftsartikel (refereegranskat)abstract
    • The instrumentation in Hall A at the Thomas Jefferson National Accelerator Facility was designed to study electro-and photo-induced reactions at very high luminosity and good momentum and angular resolution for at least one of the reaction products. The central components of Hall A are two identical high resolution spectrometers, which allow the vertical drift chambers in the focal plane to provide a momentum resolution of better than 2 x 10(-4). A variety of Cherenkov counters, scintillators and lead-glass calorimeters provide excellent particle identification. The facility has been operated successfully at a luminosity well in excess of 10(38) CM-2 s(-1). The research program is aimed at a variety of subjects, including nucleon structure functions, nucleon form factors and properties of the nuclear medium. (C) 2003 Elsevier B.V. All rights reserved.
  •  
8.
  • Andersson, Torbjörn, et al. (författare)
  • Effects of Interferon on Tumor Tissue Content in Liver Metastases of Human Carcinoid Tumors
  • 1990
  • Ingår i: Cancer Research. - 0008-5472 .- 1538-7445. ; :50, s. 3413-3415
  • Tidskriftsartikel (refereegranskat)abstract
    • In 21 patients ultrasound-guided cutting biopsies, from carcinoid metastases of the liver, were taken before and after therapy with α-interferon. Each biopsy was examined under light microscopy and the amount of tumor tissue and connective tissue was quantified and then correlated to objective response to interferon therapy. A significant reduction of the amount of tumor tissue, in spite of unaltered metastatic size and a corresponding increase in connective tissue, was seen after interferon therapy. A more pronounced reduction of tumor tissue occurred after long-term interferon therapy. A positive correlation between objective therapy response and tumor tissue reduction was also present. Patients responding poorly, or not at all, to therapy did not show any significant decrease in tumor tissue. Since treatment with immune response modifiers is expected to increase in the near future, it is important to choose the right investigations for therapy monitoring, and since all patients in this investigation had unchanged tumor size on repeated radiological examinations, it is obvious that microscopic examination of core biopsies is a better method for evaluating effects of long-term therapy than tumor size measurement with radiological techniques. Further, the results may indicate that interferon exerts a cytotoxic effect on carcinoid tumor cells in vivo.
  •  
9.
  •  
10.
  •  
11.
  •  
12.
  •  
13.
  •  
14.
  •  
15.
  •  
16.
  • Elvin, A, et al. (författare)
  • Ultrasound guided biopsies of neuroendocrine metastases : Comparison of 0.9 and 1.2 mm biopsy-gun needle biopsies
  • 1993
  • Ingår i: Acta Radiologica. - 0284-1851 .- 1600-0455. ; 34:5, s. 474-477
  • Tidskriftsartikel (refereegranskat)abstract
    • Twenty-five patients with known neuroendocrine tumour disease were biopsied with 1.2 mm and 0.9 mm biopsy-gun needles to evaluate the respective diagnostic accuracy of the 2 needle sizes. The influence of treatment-related fibrosis on the histopathological diagnosis was also evaluated. The overall diagnostic accuracy with the 0.9 mm needle was 69% as compared to 92% with the 1.2 mm needle. This difference, however, seems more related to needle guiding difficulties with the 0.9 mm needle than to insufficient tissue yield. When the tumour was hit with both the 0.9 and the 1.2 mm needle the tissue yield was inferior with the 0.9 mm needle in only one of 16 cases. The increased amount of fibrous tissue due to interferon treatment did not seem to negatively influence the diagnostic accuracy.
  •  
17.
  •  
18.
  • Eriksson, Barbro, et al. (författare)
  • Neuroendocrine pancreatic tumours : clinical presentation, biochemical and histopathological findings in 84 patients
  • 1990
  • Ingår i: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 228:2, s. 103-113
  • Tidskriftsartikel (refereegranskat)abstract
    • A prospective study has been performed on 84 patients with endocrine pancreatic tumours evaluated at the Medical Department in Uppsala. Available information concerning the patients' presenting symptoms, age at diagnosis, clinical syndrome, tumour location, location of metastases, diagnostic radiology, biochemical and histopathological findings has been analysed. Our results indicate that most patients initially show rather vague and non-specific symptoms, with dyspepsia and pain being the most frequent presenting features. The median delay between appearance of the first symptom and diagnosis was 2 years; the delay was 3 5 months in sporadic cases and 14.5 months in familial cases. In spite of improvements in diagnostic methods, the median age at diagnosis (53 years) has not been reduced, and most patients are encountered when the tumour has reached an advanced stage. There is a need for a method of screening patients with still uncharacteristic abdominalsymptoms for a neuroendocrine tumour. The presence of elevated levels of plasma chromogranin in all patients with a proven tumour suggests that such possibilities exist, and the use of this biochemical marker in the future might reduce the age at diagnosis and thus improve the likelihood of cure and survival of patients with endocrine pancreatic tumours.
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  •  
25.
  • Nilsson, Anders, 1958- (författare)
  • Power Doppler - Principles and Potential Clinical Applications
  • 2003
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The purpose of this work was to: a) Determine whether the amount of colour in a power Doppler image is dependent on the angle between the examined vessel and the soundbeam and/or on the velocity of the flow within the vessel; b) Investigate if a dependency on flow velocity could be used for the detection of volume flow differences and c) Define clinical applications utilising the improved sensitivity to low flow of PD.In the experimental studies (study I and II) a silicon tube in a water bath was insonated, the insonation angle and the volume flow changed and the resulting images stored, transferred to a personal computer and analysed with regard to the amount of colour present in the image.In study III and IV the ability of power Doppler to depict low flow was used to produce a map of the perfusion in well perfused organs, lack of colour in all or part of an organ taken as a sign of decreased perfusion. 150 patients with a renal transplant (study III) and 15 patients with abdominal trauma (study IV) were examined; the detected areas of decreased perfusion were correlated to other imaging modalities, laboratory and clinical records in order to determine the underlying pathology.In study V the power Doppler sensitivity was used to look for and describe small portosystemic shunts in 141 patients with liver cirrhoses and suspected portal hypertension.The colour representation in a power Doppler image was found to be dependent both on the insonation angle and the flow velocity. Computer analysis of the images could detect differences in volume flow down to a change of 10 ml/min.Of the 150 renal transplants, areas of decreased perfusion were found in 12, all of which could be given a plausible explanation (2 focal infections, 4 AV fistulae, 1 kinked segmental artery and 5 with problems related to an accessory artery).Of the 20 organs (7 livers and 13 spleens) examined in the 15 trauma patients, 5 were found to have areas without colour, corresponding to localised haematomas. Using computed tomography as gold standard, ultrasound showed neither false positive nor false negative findings.Of the 141 patients with cirrhosis, 40 had Doppler ultrasound findings of a shunt, consistent with a portal hypertension. 7 of these 40 shunts showed a typical “ball ” or “corkscrew ” pattern.Conclusion: The colour in a power Doppler image is dependent not only on reflector concentration (as it should be in theory) but also on the insonation angle and the velocity of the flow. This can be used to detect relative changes in volume flow. Clinical applications of power Doppler include mapping of organ perfusion and the detection of small vessels. These applications are based on the high sensitivity of power Doppler.
  •  
26.
  •  
27.
  •  
28.
  •  
29.
  • Skogseid, Britt, et al. (författare)
  • Operative tumor yield obviates preoperative pancreatic localization in multiple endocrine neoplasia type 1
  • 1995
  • Ingår i: Journal of Internal Medicine. - 0954-6820 .- 1365-2796. ; 238:3, s. 281-288
  • Tidskriftsartikel (refereegranskat)abstract
    • The efficiency of pancreatic tumour localization was prospectively evaluated in 12 consecutive patients with multiple endocrine neoplasia type 1 (MEN1), who were subjected to extirpation of 56 islet cell neoplasms of 0.2-4 cm in diameter (mean 0.8 cm) during pancreatic resection and enucleation. Computed tomography, angiography of the coeliac trunc and superior mesenteric artery, and percutaneous ultrasound correctly localized 7-12% of the tumours and 21-37% of the 19 lesions measuring at least one centimetre in diameter. Transhepatic portal vein sampling correctly located tumour sites in the proximal or distal portions of the pancreas in four out of six patients, but demonstrated unsatisfactory specificity. Intra-operative ultrasound and bidigital palpation of the pancreas had overall sensitivities of 86 and 45%, respectively, and eight lesions below 0.3 cm in diameter remained undetected with intraoperative ultrasound. It is concluded that diagnosis of endocrine pancreatic neoplasms is biochemical in MEN1 and that broad screening of tumour markers efficiently reveals pancreatic involvement decades before the development of a clinically overt disease. Intra-operative ultrasound is a requisite for pancreatic endocrine surgery in MEN1, and it obviates the need for conventional pancreatic imaging unless a pre-operative search for metastatic disease and anatomical aberrations is considered important.
  •  
30.
  • Skogseid, Britt, et al. (författare)
  • Operative tumour yield obviates preoperative pancreatic tumour localization in multiple endocrine neoplasia type 1
  • 1995
  • Ingår i: Journal of Internal Medicine. - 0954-6820 .- 1365-2796. ; 238:3, s. 281-288
  • Tidskriftsartikel (refereegranskat)abstract
    • The efficiency of pancreatic tumour localization was prospectively evaluated in 12 consecutive patients with multiple endocrine neoplasia type 1 (MEN1), who were subjected to extirpation of 56 islet cell neoplasms of 0.2-4 cm in diameter (mean 0.8 cm) during pancreatic resection and enucleation. Computed tomography, angiography of the coeliac trunc and superior mesenteric artery, and percutaneous ultrasound correctly localized 7-12% of the tumours and 21-37% of the 19 lesions measuring at least one centimetre in diameter. Transhepatic portal vein sampling correctly located tumour sites in the proximal or distal portions of the pancreas in four out of six patients, but demonstrated unsatisfactory specificity. Intra-operative ultrasound and bidigital palpation of the pancreas had overall sensitivities of 86 and 45%, respectively, and eight lesions below 0.3 cm in diameter remained undetected with intraoperative ultrasound. It is concluded that diagnosis of endocrine pancreatic neoplasms is biochemical in MEN1 and that broad screening of tumour markers efficiently reveals pancreatic involvement decades before the development of a clinically overt disease. Intra-operative ultrasound is a requisite for pancreatic endocrine surgery in MEN1, and it obviates the need for conventional pancreatic imaging unless a pre-operative search for metastatic disease and anatomical aberrations is considered important.
  •  
31.
  •  
32.
  •  
33.
  •  
34.
  •  
35.
  •  
36.
  •  
37.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-37 av 37

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy